{"product_id":"1734-iv8-c-allen-bradley-8-channel-source-input-module-point-i-o-series","title":"1734-IV8\/C Allen-Bradley 8-Channel Source Input Module Point I\/O Series","description":"\u003cp\u003eConfigured for 24 VDC digital signal acquisition in Allen-Bradley Point I\/O systems, the \u003cstrong\u003eAllen-Bradley 1734-IV8\/C\u003c\/strong\u003e (\u003cstrong\u003e1734-IV8\/C\u003c\/strong\u003e Digital DC Sourcing Input Module) provides direct field input execution through eight source input channels.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Details\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IV8\/C is a POINT I\/O digital DC sourcing input module designed for distributed I\/O applications. The module provides eight 24 VDC input channels with a maximum input current of 5 mA per channel.\u003c\/p\u003e\n\u003cp\u003eThe module communicates through the POINTBus backplane system and requires 75 mA POINTBus current. It is designed for integration into modular POINT I\/O assemblies where distributed digital field signals are collected and transferred to the controller system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IV8\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Sourcing Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 7.6 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Maximum\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eSource Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current\u003c\/td\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.5 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePOINTBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.5 BTU\/hour thermal dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePoint I\/O Network Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IV8\/C applies Allen-Bradley I\/O density scaling technology within the POINT I\/O modular platform. The compact module format allows multiple digital input channels to be installed in distributed control architectures while maintaining centralized controller communication.\u003c\/p\u003e\n\u003cp\u003eThe module communicates through the POINTBus network interface, allowing input data exchange between field devices and the controller system. Proper firmware flash compatibility and adapter configuration should be verified when adding the module to an existing POINT I\/O installation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard shipment configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 1734-IV8\/C POINT I\/O Digital DC Sourcing Input Module\u003c\/li\u003e\n\u003cli\u003e1 x Factory product identification label\u003c\/li\u003e\n\u003cli\u003e1 x Original hardware assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional components such as terminal bases, POINT I\/O adapters, mounting accessories, and network interface modules depend on the installed system configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModule Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on a compatible POINT I\/O terminal base assembly.\u003c\/li\u003e\n\u003cli\u003eVerify POINTBus power availability before module operation.\u003c\/li\u003e\n\u003cli\u003eConfirm module position and addressing within the I\/O adapter configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify 24 VDC input polarity before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding practices for control cabinet installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm controller communication settings before commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify input channel mapping in the PLC configuration software.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections before applying field power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 1734-IV8\/C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IV8\/C is an eight-channel digital DC sourcing input module used to collect 24 VDC field signals in Allen-Bradley POINT I\/O systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many input channels are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides eight independent digital input channels for connection to compatible 24 VDC field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage does the module support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is designed for 24 VDC digital input applications according to the provided technical specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the POINTBus current requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 75 mA POINTBus current from the POINT I\/O backplane communication system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of input signals can be connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accepts discrete DC source input signals from compatible industrial field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide analog measurement capability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-IV8\/C is a digital input module and does not measure analog voltage or current values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation factors affect input signal quality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper wiring separation, grounding, and correct device polarity help reduce electrical interference and signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be installed without a POINTBus adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires a compatible POINT I\/O assembly and communication adapter for integration into the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400002221,"sku":"1734-IV8\/C","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-IV8_13.jpg?v=1785121853","url":"https:\/\/www.maxwellplc.com\/ga\/products\/1734-iv8-c-allen-bradley-8-channel-source-input-module-point-i-o-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}