{"product_id":"150-f85nbdb-allen-bradley-smart-motor-controller-smc-flex-series","title":"150-F85NBDB Allen-Bradley Smart Motor Controller SMC Flex Series","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 150-F85NBDB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e150-F85NBDB\u003c\/strong\u003e Smart Motor Controller, operates as a dedicated hardware component for solid-state soft starting, pump deceleration control, and current limiting within 3-phase AC motor systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150-F\u003c\/strong\u003e: Bulletin 150 SMC Flex solid-state soft starter base architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e85\u003c\/strong\u003e: 85 A continuous output rating handling 15 to 60 hp motors at 460 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Open enclosure construction designed for panel mounting inside industrial enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: 200...480 VAC 3-phase line input operating threshold at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: 100...240 VAC control supply voltage requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Dedicated pump control algorithm configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F85NBDB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24.0 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Internal Control Dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current\u003c\/td\u003e\n\u003ctd\u003e85 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e460 VAC (Line Input: 200...480 VAC, 3-Phase, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e60 hp (15 to 60 hp at 460 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Profile\u003c\/td\u003e\n\u003ctd\u003eSoft Start, Current Limit, Pump Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Communication \u0026amp; Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit transfers real-time operational status, fault flags, and phase currents over EtherNet\/IP deterministic networks via plug-in communication modules. Microcode structures enforce strict firmware flash compatibility across control nodes, preventing handshake mismatches and latency spikes during continuous speed ramping and pump control sequences.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 150-F85NBDB Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Technical Installation Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Assembly \u0026amp; Electrical Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePhysical Mounting\n\u003cul\u003e\n\u003cli\u003eMount the open unit vertically on a flat, grounded panel surface inside a NEMA or IP rated enclosure to permit unhindered vertical convection across internal heat sinks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMain Power Wiring\n\u003cul\u003e\n\u003cli\u003eSecure 3-phase input lines to L1, L2, L3 and load cables to T1, T2, T3 according to specified terminal torque settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eControl Circuit Isolation\n\u003cul\u003e\n\u003cli\u003eWire the 100...240 VAC control source separately from high-power distribution lines to minimize electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEarth Ground Connection\n\u003cul\u003e\n\u003cli\u003eConnect a heavy-duty copper bonding conductor directly from the main enclosure earth bus to the chassis protective earth terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous current rating of the 150-F85NBDB?\u003c\/p\u003e\n\u003cp\u003eThe controller supports a continuous output rating of 85 A across 3-phase induction motor loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control supply voltage is required for internal operation?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a single-phase AC control voltage input ranging between 100 VAC and 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan live line connections be made or altered while powered?\u003c\/p\u003e\n\u003cp\u003eNo, all main 3-phase AC input lines and control voltage feeds must be isolated prior to wiring maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat motor power capacity is supported at 460 VAC?\u003c\/p\u003e\n\u003cp\u003eThe controller manages 3-phase induction motors rated from 15 hp up to 60 hp at 460 VAC nominal line voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the pump control algorithm function during operation?\u003c\/p\u003e\n\u003cp\u003eIntegrated pump profiles control torque acceleration and deceleration ramps to eliminate fluid surging and hammer effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external protective panel required for installation?\u003c\/p\u003e\n\u003cp\u003eYes, as an open enclosure device, it must be mounted inside a protected electrical cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the controller interface with higher-level network systems?\u003c\/p\u003e\n\u003cp\u003eOptional communication cards slot internally while maintaining firmware flash compatibility across network nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input line voltage parameters can be applied to power terminals?\u003c\/p\u003e\n\u003cp\u003eThe main power circuit accepts 3-phase line voltages from 200 VAC up to 480 VAC at nominal 50\/60 Hz frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066397249709,"sku":"150-F85NBDB","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_4-1_28be553a-d645-4030-87e1-1746b1791350.jpg?v=1786074224","url":"https:\/\/www.maxwellplc.com\/ga\/products\/150-f85nbdb-allen-bradley-smart-motor-controller-smc-flex-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}