{"product_id":"150-f60nbdd-allen-bradley-smart-motor-controller-bulletin-150-smc-flex","title":"150-F60NBDD Allen-Bradley Smart Motor Controller Bulletin 150 SMC Flex","description":"\u003cp\u003eConfigured for controlled three-phase induction motor starting, acceleration profiling, and dynamic braking in power distribution networks, the \u003cstrong\u003eAllen-Bradley 150-F60NBDD\u003c\/strong\u003e (\u003cstrong\u003e150-F60\u003c\/strong\u003e Solid-State Soft Starter) provides direct physical\/electrical execution. It regulates operational continuous currents up to 60 A on main lines operating between 200 and 480 VAC at 50\/60 Hz. The solid-state power assembly utilizes silicon-controlled rectifiers (SCRs) to modulate voltage ramps during startup with a 350% starting duty capability, limiting mechanical shock and reducing peak electrical line loading during motor state transitions.\u003c\/p\u003e\n\u003ch3\u003eCatalog Nomenclature \u0026amp; Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150-F\u003c\/strong\u003e: Designates the Bulletin 150 SMC Flex solid-state soft starter platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60\u003c\/strong\u003e: Represents the 60 A nominal operational current rating for standard inline load wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Open enclosure structural frame (IP00 rated) intended for cabinet assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Operating main line voltage range specified at 200...480 VAC, 3-Phase, 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Control circuit operating power supply specification covering 100...240 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Factory-installed internal option board configured for Smart Motor Braking (SMB) control algorithms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Operating Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F60NBDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 W (Control Logic Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Continuous Current\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower Rating\u003c\/td\u003e\n\u003ctd\u003e40 HP @ 460 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Duty Cycle\u003c\/td\u003e\n\u003ctd\u003e350% for 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Line Voltage\u003c\/td\u003e\n\u003ctd\u003e200...480 VAC (480 VAC, 60 Hz typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; Deterministic Network Messaging\u003c\/h3\u003e\n\u003cp\u003eThe soft starter integrates into Logix-based control systems through DPI expansion ports connected to optional communication adapters. Communicating across EtherNet\/IP deterministic networks, the controller cyclically sends current feedback metrics, internal thermal percentages, and operational trip flags. High-speed processor firmware flash compatibility maintains microsecond SCR firing pulse synchronization, preserving low-latency data updates and maintaining system I\/O density scaling during network-triggered start, ramp, or brake routines.\u003c\/p\u003e\n\u003ch3\u003eEquipment Package Contents List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 150-F60NBDD Solid-State Starter Chassis\u003c\/li\u003e\n\u003cli\u003e1 x Factory-Integrated Braking Option Card\u003c\/li\u003e\n\u003cli\u003e1 x Set of Terminal Protective Isolation Barriers\u003c\/li\u003e\n\u003cli\u003e1 x Mechanical Installation Sheet and Wiring Diagram Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Field Cabling Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Mounting Rules\n\u003cul\u003e\n\u003cli\u003eMount the open frame chassis vertically onto an unpainted grounded metal panel within a protective enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum free space of 150 mm above and below the starter assembly to allow unimpeded natural air convection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCabling and Signal Separation\n\u003cul\u003e\n\u003cli\u003eRoute low-voltage 100...240 VAC control supply conductors in isolated wire ducts separated from 3-phase line and load power cables.\u003c\/li\u003e\n\u003cli\u003eConnect the primary protective earth lug to the main system ground bus using a short, low-impedance copper jumper.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions and Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input control voltage does the 150-F60NBDD control block require?\u003c\/p\u003e\n\u003cp\u003eThe control terminal block operates on an AC control voltage range of 100...240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat function is enabled by the double D suffix code in this model number?\u003c\/p\u003e\n\u003cp\u003eThe D suffix indicates a 100...240 VAC control voltage rating combined with an internal option board for Smart Motor Braking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat starting current capacity does the 150-F60NBDD soft starter support?\u003c\/p\u003e\n\u003cp\u003eThe unit is rated for a 350% starting duty cycle during initial acceleration sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this soft starter be operated outside of an enclosure?\u003c\/p\u003e\n\u003cp\u003eNo, the chassis uses an Open IP00 frame design and must be housed inside an IP54 or NEMA-rated enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the starter limit power dissipation during continuous full-speed operation?\u003c\/p\u003e\n\u003cp\u003eInternal bypass contactors engage automatically once motor acceleration completes, bypassing the power SCRs to lower thermal losses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the internal logic firmware be updated through diagnostic field tools?\u003c\/p\u003e\n\u003cp\u003eYes, onboard control logic features firmware flash compatibility via DPI adapters using standard automation software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit monitor thermal overload conditions on the motor?\u003c\/p\u003e\n\u003cp\u003eThe internal electronics calculate motor thermal capacity based on measured phase currents and user-configured motor trip classes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are fault trip conditions cleared after a system protection lockout?\u003c\/p\u003e\n\u003cp\u003eFaults are cleared by applying a reset pulse to the reset terminal, cycling control power, or sending a network reset command.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066391711917,"sku":"150-F60NBDD","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_2-3.jpg?v=1786074178","url":"https:\/\/www.maxwellplc.com\/ga\/products\/150-f60nbdd-allen-bradley-smart-motor-controller-bulletin-150-smc-flex","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}