{"product_id":"150-f25nbdb-allen-bradley-smc-flex-series-smart-motor-controller","title":"150-F25NBDB Allen-Bradley SMC Flex Series Smart Motor Controller","description":"\u003cp\u003eConfigured for controlled fluid acceleration and soft stopping in 3-phase AC motor circuits, the \u003cstrong\u003eAllen-Bradley 150-F25NBDB\u003c\/strong\u003e (\u003cstrong\u003e150-F25\u003c\/strong\u003e Smart Motor Controller) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eCatalog Code Structure Analysis\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150-F\u003c\/strong\u003e: Bulletin 150 SMC Flex solid-state smart motor controller base framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25\u003c\/strong\u003e: 25 A continuous current output rating capable of driving motors up to 15 hp at 460 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Open enclosure open-frame housing designed for cabinet panel integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: 200...480 VAC 3-phase line input operating range at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: 100...240 VAC control circuit operational power input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Dedicated pump control option algorithm to reduce fluid surge and water hammer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Data Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F25NBDB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24.0 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Internal Control Dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e460 VAC (Line Input: 200...480 VAC, 3-Phase, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e15 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Profile\u003c\/td\u003e\n\u003ctd\u003eSoft Start, Current Limit, Pump Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Communication \u0026amp; Controller Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe solid-state soft starter integrates with higher-level Logix controllers, transferring operational parameters and status words across EtherNet\/IP deterministic networks via optional communication adapters. Microcode architecture preserves firmware flash compatibility, preventing control timing jitter and data frame mismatches during continuous PLC automation sweeps.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivered Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 150-F25NBDB Smart Motor Controller Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Technical Installation Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControl Cabinet Assembly \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePhysical Panel Mounting\n\u003cul\u003e\n\u003cli\u003eMount the open-style controller vertically onto an unpainted, conductive backpanel inside a protective cabinet to ensure unrestricted vertical convective cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Terminal Connections\n\u003cul\u003e\n\u003cli\u003eTerminate incoming 3-phase mains lines to L1, L2, L3 and motor leads to T1, T2, T3 according to marked screw terminal torque limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eControl Wire Routing\n\u003cul\u003e\n\u003cli\u003eKeep 100...240 VAC control supply conductors in separate wiring trunks, physically isolated from high-voltage main power leads to mitigate inductive noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding Circuit Integration\n\u003cul\u003e\n\u003cli\u003eSecure a low-impedance copper ground wire directly from the industrial enclosure earth bus to the chassis protective earth terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Technical FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous current output capacity of the 150-F25NBDB?\u003c\/p\u003e\n\u003cp\u003eThe controller delivers a continuous current output rating of 25 A for 3-phase AC induction motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control circuit supply voltage is required for internal logic operation?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a single-phase AC control voltage input ranging from 100 VAC to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan main line conductors be serviced while control voltage remains energized?\u003c\/p\u003e\n\u003cp\u003eNo, both the 3-phase AC line voltage and control circuit supply must be isolated before touching power terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat motor power capacity does this unit control at 460 VAC line input?\u003c\/p\u003e\n\u003cp\u003eThe module manages 3-phase AC motor applications rated up to 15 hp when supplied with 460 VAC nominal power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat functional benefit does the pump control algorithm deliver?\u003c\/p\u003e\n\u003cp\u003eThe pump control option manages acceleration and deceleration torque ramps to eliminate fluid pressure spikes and water hammer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external enclosure mandatory for housing this starter module?\u003c\/p\u003e\n\u003cp\u003eYes, as an open enclosure device, it must be mounted inside a NEMA or IP rated protective cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the starter maintain controller parameter synchronization?\u003c\/p\u003e\n\u003cp\u003eOption modules route diagnostic data across fieldbuses while maintaining firmware flash compatibility with host CPUs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat main line input voltage parameters apply to the power terminals?\u003c\/p\u003e\n\u003cp\u003eThe power terminals accommodate 3-phase AC input operating line voltages from 200 VAC up to 480 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066384568493,"sku":"150-F25NBDB","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_6-5_7ea5b3c1-e177-4a50-ab75-127bee568266.jpg?v=1786074487","url":"https:\/\/www.maxwellplc.com\/ga\/products\/150-f25nbdb-allen-bradley-smc-flex-series-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}