{"product_id":"145988-01-bently-nevada-3500-94-vga-visual-display-monitoring-module-3500-series","title":"145988-01 Bently Nevada 3500\/94 VGA Visual Display Monitoring Module 3500 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 145988-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/94\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVGA Visual Display Monitor Module, operates as a dedicated hardware component for localized HMI data visualization and process parameter monitoring within the 3500 Machinery Protection System network.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 145988-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Series: 3500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunctional Class: Visual Display Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/94 145988-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.78 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 cm x 25.2 cm x 24 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 W (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-485 \/ VGA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSI (Turbomachinery Information)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/94 module facilitates the integration of rotor dynamics data into the rack-mounted display architecture. It performs internal processing of transducer inputs, specifically scaling eddy-current probe inputs relative to established gap voltage targets. The module ensures precise cross-talk suppression by isolating the display data stream from the primary protection logic path. It supports the visualization of orbit plots, time-base waveforms, and bar graphs derived from the rack backplane bus, ensuring the gap voltage validation stays within the required -10 VDC operational window for standard proximity probe configurations.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e145988-01 VGA Display Monitor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard 3500 backplane connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirmware configuration guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting and Field Implementation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: The module must be inserted into the designated slot within the 3500 rack. Ensure the backplane interface pins are aligned to prevent mechanical damage during seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Use shielded twisted-pair cabling for all RS-485 communication links to prevent electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the rack chassis is connected to a low-impedance earth ground to satisfy electrical safety protocols and prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-Swap Limitation: Although the 3500 backplane supports hot-swapping, verify that the module's removal does not trigger false status alarms on the primary monitoring configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry and System Diagnostics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 145988-01 module?\u003c\/p\u003e\n\u003cp\u003eThe module serves as an interface for presenting real-time machinery protection system data on an external VGA display device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module perform protection logic?\u003c\/p\u003e\n\u003cp\u003eNo, this is a display monitoring module. It provides data for visualization and does not execute independent machine trip logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is data retrieved from the 3500 rack?\u003c\/p\u003e\n\u003cp\u003eThe module communicates via the 3500 rack backplane bus to aggregate data from other installed modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the module field-configurable?\u003c\/p\u003e\n\u003cp\u003eYes, configuration is managed through the 3500 Rack Configuration Software via the interface module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the voltage requirements?\u003c\/p\u003e\n\u003cp\u003eThe module operates on the standard 3500 system backplane power supply (typically +24 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module function without a primary rack interface?\u003c\/p\u003e\n\u003cp\u003eNo, the module requires a configured rack interface module to manage data polling and system-wide synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle signal scaling?\u003c\/p\u003e\n\u003cp\u003eIt uses the programmed transducer scale factor within the configuration software to ensure accurate units of measurement on the display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the RS-485 interface for user communication?\u003c\/p\u003e\n\u003cp\u003eNo, the RS-485 interface is generally reserved for communication with auxiliary industrial modules or dedicated serial display peripherals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378091090093,"sku":"145988-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-3500-94-145988-01-vga-display-monitor-ijpyu2p25hi.jpg?v=1764225514","url":"https:\/\/www.maxwellplc.com\/ga\/products\/145988-01-bently-nevada-3500-94-vga-visual-display-monitoring-module-3500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}