{"title":"Omron Drives, Servo \u0026 Motion Control","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eOmron\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eservo drives, motors and motion control products\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide precise positioning, speed regulation and reliable movement control for advanced industrial automation systems. These components are designed for applications requiring accurate motion performance, fast response and stable operation.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis category includes Omron\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC drives, inverter systems, servo amplifiers and servo motors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in machine automation, robotics, packaging equipment and production lines.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3G3 Series inverter drives\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffer efficient motor control solutions for industrial equipment. Models from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3G3JV, 3G3JZ and 3G3MX2 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare commonly used for variable speed applications, conveyor systems, pumps, fans and general machine control.\u003c\/p\u003e\n\u003cp\u003eOmron\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR7D and R88D servo drives\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide high-performance motion control with accurate positioning capability. Combined with compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR7M and R88M servo motors\u003c\/strong\u003e, these systems support demanding automation tasks requiring smooth operation and repeatable accuracy.\u003c\/p\u003e\n\u003cp\u003eOmron motion products are widely integrated into CNC equipment, robotics, semiconductor machinery, assembly systems and automated manufacturing lines.\u003c\/p\u003e\n\u003cp\u003eFor machine builders, maintenance teams and automation engineers, Omron\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eservo systems and drive solutions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide dependable components for new installations, equipment upgrades and replacement projects.\u003c\/p\u003e","products":[{"product_id":"3g3jv-a4037-omron-variable-frequency-drive-3g3jv-series","title":"3G3JV-A4037 Omron Variable Frequency Drive 3G3JV Series","description":"\u003cp\u003eConfigured for 3-phase speed regulation and dynamic frequency synthesis in 3G3JV control systems, the \u003cstrong\u003eOmron 3G3JV-A4037\u003c\/strong\u003e (\u003cstrong\u003e3G3JV\u003c\/strong\u003e Micro Inverter) provides direct physical execution of pulse-width modulated motor power output.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Structure Analysis\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JV\u003c\/strong\u003e: Base micro inverter series chassis identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting model with standard enclosed housing structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase AC 380 V to 460 V voltage classification (400 V level).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e037\u003c\/strong\u003e: Maximum applicable motor rating of 3.7 kW capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications \u0026amp; Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JV-A4037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron Automation and Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg (4.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm x 140 mm x 161 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e380 VAC to 460 VAC 3-phase (460 V nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rated Current\u003c\/td\u003e\n\u003ctd\u003e8.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Output Type\u003c\/td\u003e\n\u003ctd\u003eMulti-function relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mount or direct DIN Rail via optional adapter bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Network \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 3G3JV controller integrates internal bus communication routing for Modbus network connectivity over RS-485 interfaces. System logic registers support direct memory mapping and firmware flash compatibility to match standard PLC backplane communication cycles and system status polling speeds without data transfer overhead.\u003c\/p\u003e\n\u003ch3\u003ePackage Component Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JV-A4037 micro VFD unit\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation and terminal connection wiring manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Cabling Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Clearance\u003c\/p\u003e\n\u003cp\u003eMount upright on a flat metal plate or DIN rail using the optional mounting bracket, retaining 100 mm vertical clearance for airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Lead Separation\u003c\/p\u003e\n\u003cp\u003eRoute 460 VAC input power wiring away from low-voltage relay output and analog control signal cables by at least 200 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Cable Termination\u003c\/p\u003e\n\u003cp\u003eConnect high-frequency shield braids directly to the main chassis earth stud using short, heavy-gauge copper conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage range is compatible with the 3G3JV-A4037?\u003c\/p\u003e\n\u003cp\u003eThe drive operates on a 3-phase AC supply rated from 380 VAC to 460 VAC at 50\/60 Hz line frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output load current does this inverter model deliver?\u003c\/p\u003e\n\u003cp\u003eThe power circuit supplies a continuous load output current of up to 8.6 A to the connected motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mounting options are supported by the physical frame?\u003c\/p\u003e\n\u003cp\u003eThe enclosure supports direct panel-mounting or snap-on installation via an optional DIN-rail adapter bracket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal output interface is integrated on the terminal board?\u003c\/p\u003e\n\u003cp\u003eThe control section includes a multi-function relay output for programmable status signaling and fault alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping terminal lines permitted during power application?\u003c\/p\u003e\n\u003cp\u003eNo, removing power or signal wires while voltage is present risks electric arc damage to internal circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should control cables be shielded against ambient noise?\u003c\/p\u003e\n\u003cp\u003eUse twisted-pair shielded conductors for external signal lines, bonding the braid to ground at the drive end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is allowable during operation?\u003c\/p\u003e\n\u003cp\u003eThe unit operates within -10 deg C to +50 deg C under non-condensing atmospheric conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is excessive heat removed from the inverter chassis?\u003c\/p\u003e\n\u003cp\u003eInternal thermal energy dissipates via natural convection combined with the rear aluminum heatsink structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306594943149,"sku":"3G3JV-A4037","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3JV-A4037.jpg?v=1787718972"},{"product_id":"3g3jz-a4004-omron-inverter-sysdrive-3g3jz-series","title":"3G3JZ-A4004 Omron Inverter SYSDRIVE 3G3JZ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3JZ-A4004\u003c\/strong\u003e serves as the primary \u003cstrong\u003e3G3JZ-A4004\u003c\/strong\u003e Inverter utilized to execute pulse-width modulated variable frequency motor regulation across SYSDRIVE 3G3JZ Series platforms.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Base product family identifier for compact SYSDRIVE AC variable frequency drive units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware enclosure standard indicating panel-mounting IP20 minimum \/ closed wall mounting design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: Input line voltage rating classification corresponding to 3-phase AC 400 V power networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e004\u003c\/strong\u003e: Maximum rated motor drive capacity specified for 0.4 kW 3-phase induction motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Capacity\u003c\/td\u003e\n\u003ctd\u003e0.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Design\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.4 kW rated motor load output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 x 18.0 x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Network Interface\u003c\/h3\u003e\n\u003cp\u003eThe drive incorporates onboard serial logic interfacing via Modbus RS-485 to facilitate integration into Profinet \/ EtherNet\/IP deterministic networks via host gateway interfaces. Internal processing circuits handle parameter expansion and maintain strict firmware flash compatibility validation during system initialization to guarantee configuration integrity across multi-drive panel builds.\u003c\/p\u003e\n\u003ch3\u003ePackage Inclusions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4004 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective inner packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Field Installation Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Panel Assembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the inverter vertically against an unpainted metallic panel within an IP20 or higher enclosure.\u003c\/li\u003e\n\u003cli\u003eProvide an unimpeded thermal dissipation gap of at least 100 mm above and below the drive housing.\u003c\/li\u003e\n\u003cli\u003eSecure mounting screws to standard torque ratings to resist structural vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring Practices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect incoming 3-phase AC 400 V mains power directly to line terminals L1, L2, and L3.\u003c\/li\u003e\n\u003cli\u003eRoute motor power connections from terminals T1, T2, and T3 using continuous shielded cable.\u003c\/li\u003e\n\u003cli\u003eConnect the drive frame earth terminal directly to the enclosure main ground bus with a short copper wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated input supply voltage for the 3G3JZ-A4004 inverter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe inverter operates on a nominal 3-phase AC 400 V power supply for 400 V class industrial motor applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor sizing limit applies to this drive model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific model is engineered to drive 3-phase AC induction motors with a maximum capacity of 0.4 kW.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the drive main power terminals be hot-swapped during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Input mains power must be disconnected and internal DC bus capacitors discharged before terminal access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is electrical noise prevented on low-voltage control circuits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControl signal cables must be run as twisted-pair shielded lines separate from AC power and motor cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat enclosure ingress protection rating does this unit feature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive carries an IP20 minimum closed wall enclosure design intended for panel-mounted cabinet installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is frame ground integrity established during cabinet fitting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding is maintained via the dedicated PE lug wired directly to the primary electrical grounding rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit interface with high-level automation fieldbuses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive communicates via onboard Modbus RS-485 serial ports connected to control network gateways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat safety mechanism prevents invalid parameters during system boots?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem boot routines execute automated firmware flash compatibility verification prior to enabling motor execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306597564589,"sku":"3G3JZ-A4004","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4004_2.jpg?v=1787719773"},{"product_id":"3g3jz-a4007-omron-inverter-sysdrive-3g3jz-series","title":"3G3JZ-A4007 Omron Inverter SYSDRIVE 3G3JZ Series","description":"\u003cp\u003eConfigured for variable-speed control of three-phase motors, the \u003cstrong\u003eOmron 3G3JZ-A4007\u003c\/strong\u003e (\u003cstrong\u003e3G3JZ\u003c\/strong\u003e inverter) provides V\/f-based motor control from a 400 V-class three-phase supply. The unit is rated for motors up to 0.75 kW and provides a rated output current of 2.5 A.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe model designation separates the 3G3JZ series, enclosure type, voltage class, and applicable motor capacity. Omron documentation identifies the A4007 as a panel-mounting model with an IP20 minimum enclosure structure and three-phase AC400 V class input.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3G3JZ\u003c\/td\u003e\n\u003ctd\u003eSYSDRIVE 3G3JZ series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting model, IP20 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eThree-phase AC400 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e007\u003c\/td\u003e\n\u003ctd\u003eMaximum applicable motor capacity: 0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete model\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSYSDRIVE 3G3JZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003eThree-phase AC380 to 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Capacity\u003c\/td\u003e\n\u003ctd\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eThree-phase, up to input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/f control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Frequency\u003c\/td\u003e\n\u003ctd\u003e2 to 15 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting, IP20 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSelf-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Torque Function\u003c\/td\u003e\n\u003ctd\u003eMore than 150% torque at 3 Hz with torque boost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C; -10 to +40 deg C for close mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e90% RH or less, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot separately specified; rated motor capacity is 0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 72 x 135.7 x 174 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eNot published in the referenced Omron documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina marking appears in the referenced product documentation; verify nameplate for individual unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe 3G3JZ-A4007 has a rated output current of 2.5 A. The documented 3G3JZ-A4007 installation dimensions fall within the 72 x 135.7 x 174 mm frame group.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Drive and Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3G3JZ series uses V\/f control as its primary motor-control method. The A4007 variant is intended for three-phase 400 V-class power systems and is matched to motors up to 0.75 kW.\u003c\/p\u003e\n\u003cp\u003eStandard RS485 communication permits connection to a PLC or host controller. The documentation identifies RS485 as a standard interface for control and monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe inverter also provides six multifunction input terminals. Parameter-based operation can be used for frequency and command control without requiring every operating function to be hardwired.\u003c\/p\u003e\n\u003cp\u003eThe adjustable carrier frequency range is 2 to 15 kHz. A torque-boost function can provide more than 150% torque at 3 Hz under the specified operating conditions.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4007 AC Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Safety Precautions documentation, where supplied with the unit\u003c\/li\u003e\n\u003cli\u003eMounting screws and installation hardware are not identified as standard supplied accessories and should be provided by the installer.\u003c\/li\u003e\n\u003cli\u003eExternal braking or other optional equipment is not included unless separately specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the inverter vertically with the nameplate orientation readable from the front.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 120 mm clearance above and below the inverter for normal heat dissipation.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50 mm lateral spacing for normal mounting conditions.\u003c\/li\u003e\n\u003cli\u003eFor close mounting, the allowable operating temperature is reduced to -10 to +40 deg C.\u003c\/li\u003e\n\u003cli\u003eInstall the unit in a clean location without excessive oil mist, dust, metal particles, or water.\u003c\/li\u003e\n\u003cli\u003eIf the surrounding environment contains floating contaminants, use a suitable enclosed control panel.\u003c\/li\u003e\n\u003cli\u003eDo not mount the inverter on combustible materials.\u003c\/li\u003e\n\u003cli\u003eConnect the three-phase input to R\/L1, S\/L2, and T\/L3.\u003c\/li\u003e\n\u003cli\u003eConnect motor output terminals to U\/T1, V\/T2, and W\/T3.\u003c\/li\u003e\n\u003cli\u003eUse an appropriate protective circuit breaker for the inverter supply.\u003c\/li\u003e\n\u003cli\u003eFor control wiring, use shielded cable where required and terminate the shield according to the installation manual.\u003c\/li\u003e\n\u003cli\u003eKeep control wiring separated from high-current motor and power wiring to reduce electrical interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe documented installation requirements specify vertical mounting and minimum heat-dissipation clearances for the A4004 to A4007 400 V models.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor rating is specified for the 3G3JZ-A4007?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum applicable motor capacity is 0.75 kW. The rated inverter output current is 2.5 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input supply does the A4007 require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is the three-phase 400 V class version. Published electrical data specifies approximately 380 to 480 V AC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat control method does this inverter use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3G3JZ series is based on V\/f control. Torque boost is available for low-frequency motor operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the inverter have RS485 communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. RS485 is provided as a standard communication interface and can be used for PLC or host-controller communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated output current?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified rated output current for the 3G3JZ-A4007 is 2.5 A. This value should be considered when matching the inverter to the motor load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNormal panel mounting permits -10 to +50 deg C. Close mounting reduces the specified range to -10 to +40 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting clearance is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documented installation arrangement requires at least 120 mm above and below the unit and at least 50 mm lateral clearance under normal mounting conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the A4007 fan-cooled?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.75 kW A4007 is identified as a self-cooling model without a cooling fan. Ventilation clearance must therefore be maintained around the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306608312493,"sku":"3G3JZ-A4007","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4007_1.jpg?v=1787719906"},{"product_id":"3g3mx2-a4007-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4007-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4007-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter, operates as a dedicated hardware component for 3-phase AC motor speed regulation and torque control within MX2 Series automation networks.\u003c\/p\u003e\n\u003ch3\u003eDesignated Model Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base compact drive series identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting panel enclosure rated for IP10 minimum wall mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase AC 400 V voltage class (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e007\u003c\/strong\u003e: Maximum applicable motor output capacity rated for 0.75 kW (CT rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Factory specific functional software suffix modification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Electrical \u0026amp; Physical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4007-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e170 mm x 130 mm x 155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Class\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 380 V to 480 V (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Capacity (CT)\u003c\/td\u003e\n\u003ctd\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e2.5 A (CT rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 \/ panel mounting \/ closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.75 kW nominal power rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Communication \u0026amp; Interface Architecture\u003c\/h3\u003e\n\u003cp\u003eThe MX2 platform integrates deterministic network communication logic to facilitate EtherNet\/IP and Modbus slave exchanges. Dedicated protocol stacks maintain real-time speed instruction synchronization and diagnostic polling while ensuring firmware flash compatibility across standard controller backplanes.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4007-ZV1 compact inverter unit\u003c\/li\u003e\n\u003cli\u003e1 x Operator instruction sheet and connection wiring guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Assembly \u0026amp; Cabling Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Layout\u003c\/p\u003e\n\u003cp\u003eInstall upright on a rigid vertical plate to permit upward convection airflow over the rear extrusion heatsink.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Separation\u003c\/p\u003e\n\u003cp\u003eKeep a minimum clearance of 100 mm top\/bottom and 10 mm left\/right between neighboring components inside the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth Grounding\u003c\/p\u003e\n\u003cp\u003eConnect motor frame ground cables directly to the drive earth stud using short braided copper straps to minimize high-frequency leakage currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input voltage rating of the 3G3MX2-A4007-ZV1?\u003c\/p\u003e\n\u003cp\u003eThe power circuit accepts 3-phase 380 VAC to 480 VAC line input at a nominal system frequency of 50 Hz or 60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output current does this drive deliver under continuous torque (CT) mode?\u003c\/p\u003e\n\u003cp\u003eUnder standard CT motor load conditions, the unit provides a continuous rated output current of 2.5 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the ZV1 suffix represent in the product code?\u003c\/p\u003e\n\u003cp\u003eThe ZV1 designation indicates a specific factory software parameter set tailored for standard system software integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed for power connections or terminal strips?\u003c\/p\u003e\n\u003cp\u003eNo, removing terminal wiring or main line power connections while energized will trigger internal arcs and damage control electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should control signals be wired to prevent electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eAll 0-10 VDC analog control and RS-485 serial cables must utilize twisted shielded pairs grounded strictly at one end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is allowable for daily drive operation?\u003c\/p\u003e\n\u003cp\u003eThe inverter operates continuously within -10 deg C to +50 deg C without needing current derating under standard mounting conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is dynamic braking implemented for high-inertia loads?\u003c\/p\u003e\n\u003cp\u003eAn internal braking chopper circuit connects external power braking resistors directly across terminals RB1 and RB2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat IP protection level is provided by the physical housing?\u003c\/p\u003e\n\u003cp\u003eThe standard enclosure meets an IP10 rating, requiring placement inside an IP54 or equivalent industrial panel for outdoor or dusty sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306618175661,"sku":"3G3MX2-A4007-ZV1","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4007-zv1_1.jpg?v=1787722003"},{"product_id":"3g3mx2-a4030-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4030-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4030-ZV1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter utilized to execute pulse-width modulated frequency control and dynamic motor torque regulation across MX2 Series drive platforms.\u003c\/p\u003e\n\u003ch3\u003ePart Number Code Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter chassis architecture identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting structure (IP10 minimum \/ closed wall-mounting type).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase AC 400 V supply voltage class (380 V to 480 V operational range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e030\u003c\/strong\u003e: Maximum applicable motor capacity of 3.0 kW (Continuous Torque rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Designated software\/functional variation index.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4030-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e210 mm x 180 mm x 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Class\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Torque Rating\u003c\/td\u003e\n\u003ctd\u003e3.0 kW motor capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e7.2 A (CT output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.0 kW nominal drive output power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Bus Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe internal logic structure incorporates high-speed backplane bus communication interface capabilities to coordinate deterministic network timing over EtherNet\/IP and Modbus networks. Integrated firmware flash compatibility guarantees deterministic I\/O scan cycles and rapid parameter updating without introducing data transmission latencies during full-duplex network communications.\u003c\/p\u003e\n\u003ch3\u003eComponent Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4030-ZV1 inverter unit\u003c\/li\u003e\n\u003cli\u003e1 x Quick instruction manual and terminal connection diagram\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSite Mounting \u0026amp; Terminal Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Orientation\u003c\/p\u003e\n\u003cp\u003eFix the inverter vertically onto a rigid metallic cabinet panel to guarantee unimpeded heat dissipation along the heat sink channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpacing Limits\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum clearance of 100 mm above and below the drive frame, plus 10 mm lateral spacing between neighboring devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding \u0026amp; Grounding Terminations\u003c\/p\u003e\n\u003cp\u003eClamp shielded motor output lines using a low-impedance copper cable gland directly to the panel earth bus to suppress high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal input supply voltage for the 3G3MX2-A4030-ZV1?\u003c\/p\u003e\n\u003cp\u003eThe drive operates on a 3-phase AC power line rated from 380 VAC to 480 VAC at 50\/60 Hz line frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output current does this drive deliver at the 3.0 kW CT rating?\u003c\/p\u003e\n\u003cp\u003eUnder continuous torque operation, the drive supplies up to 7.2 A of rated output current to the motor terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat degree of physical enclosure protection does the unit feature?\u003c\/p\u003e\n\u003cp\u003eThe unit complies with IP10 enclosure guidelines and must be installed inside an industrial cabinet rated IP54 or higher.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan line power or motor cables be disconnected while energized?\u003c\/p\u003e\n\u003cp\u003eNo, live terminal disconnection causes electrical arcing, which damages the internal IGBT inverter stage and internal logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should analog speed reference signals be cabled?\u003c\/p\u003e\n\u003cp\u003eAnalog 0-10 VDC and 4-20 mA command wires require twisted-pair shielded cables grounded strictly at the drive ground terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat heat dissipation measures are required during panel assembly?\u003c\/p\u003e\n\u003cp\u003eThe drive relies on forced air convection, requiring unobstructed airflow paths across the rear extrusion heat sink assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the ZV1 code suffix indicate on the drive label?\u003c\/p\u003e\n\u003cp\u003eThe ZV1 designator identifies a specific factory software parameter set intended for standardized system software integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the permissible operating temperature envelope for this model?\u003c\/p\u003e\n\u003cp\u003eThe unit operates reliably between -10 deg C and +50 deg C in ambient environments free from dripping water or corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306622238893,"sku":"3G3MX2-A4030-ZV1","price":202.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3MX2-A4030-ZV1_1.jpg?v=1787722396"},{"product_id":"r88d-1sn08h-ect-omron-servo-drive-1s-series","title":"R88D-1SN08H-ECT Omron Servo Drive 1S Series","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron R88D-1SN08H-ECT\u003c\/b\u003e serves as the primary \u003cb data-path-to-node=\"4\" data-index-in-node=\"48\"\u003eR88D-1SN08H\u003c\/b\u003e Servo Drive utilized to execute high-speed motion profile tracking and dynamic vector torque control across EtherCAT communications platforms.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Breakdown \u0026amp; Variant Coding\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003eR88D: Standard Omron AC servo drive platform prefix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e1S: 1S Series motion execution architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003eN: Network communications control type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e08: 750 W output power capacity rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003eH: 230 VAC input voltage classification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003eECT: Integrated EtherCAT fieldbus interface protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eCore Hardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eR88D-1SN08H-ECT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e2.00 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e220 mm x 115 mm x 240 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 deg C to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e750 W (Rated capacity output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eInput Power Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003eSingle-phase \/ Three-phase 200 to 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eDrive Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003eNetwork communications AC servo amplifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eBus Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003eEtherCAT CoE (CAN application protocol over EtherCAT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eApplicable Motor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003eR88M-1M75030(H\/T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDeterministic Motion Bus \u0026amp; Flash Firmware Integration\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe drive executes high-precision motion loops synchronized with central Sysmac controllers. Dynamic firmware flash compatibility guarantees continuous operational handshakes, eliminating cyclic jitter. High I\/O density scaling and predictable backplane bus communication velocity Licences sustain rapid velocity adjustments across complex multi-axis motion networks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eDelivery Package Components\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x R88D-1SN08H-ECT AC Servo Drive Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Main Power \u0026amp; Motor Power Terminal Plug Set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x EtherCAT Network Interface Connector Shield Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation \u0026amp; Enclosure Directives\u003c\/h3\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eMounting Configuration\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eMount the drive vertically on a flat metallic enclosure sub-panel using M4 bolts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eMaintain a minimum vertical clearance of 100 mm above and below the drive frame to permit unrestricted natural thermal convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"16\"\u003eCabling \u0026amp; Noise Mitigation Rules\u003c\/h4\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eRoute high-voltage AC mains and motor output leads completely separate from low-voltage encoder and EtherCAT bus cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eTerminate the motor power cable shield directly to the drive frame ground clamp using a short, heavy-gauge bonding connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eTechnical Inquiry Resolutions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003eWhat specific servo motor model is compatible with this drive?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,0,1\"\u003eThis drive operates natively with the Omron R88M-1M75030(H\/T) 750 W AC servo motor series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003eWhat control communication protocol does the drive use?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,1,1\"\u003eThe unit utilizes high-speed EtherCAT fieldbus communications running CoE (CAN application protocol over EtherCAT).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003eWhat is the input operating voltage specification?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,2,1\"\u003eThe internal power stage requires a single-phase or three-phase supply of 200 to 240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003eIs hot-swapping allowed on the main power or motor terminals?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,3,1\"\u003eMain AC input power and motor lines must be completely de-energized prior to connecting or disconnecting drive terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,4,0\"\u003eWhat thermal operating limits govern enclosure installation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,4,1\"\u003eThe drive operates continuously within an ambient temperature window of 0 deg C to 55 deg C without thermal derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,5,0\"\u003eHow are encoder feedback signals connected to the unit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,5,1\"\u003eEncoder signals connect via a dedicated shielded feedback port located on the front panel interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,6,0\"\u003eDoes the drive support direct firmware flashing over the network?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,6,1\"\u003eFirmware flash compatibility allows safe field updates directly through the host controller network port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,7,0\"\u003eWhat is the physical weight of the drive assembly?\u003c\/p\u003e\n\u003cp data-path-to-node=\"19,7,1\"\u003eThe complete hardware drive assembly has a total weight rating of 2.00 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306622763181,"sku":"R88D-1SN08H-ECT","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/r88d-1sn08h-ect0.jpg?v=1790391144"},{"product_id":"r7m-a40030-bs1-omron-my-series-general-purpose-relay","title":"R7M-A40030-BS1 Omron MY Series General Purpose Relay","description":"\u003cp\u003eConfigured for discrete signal switching and auxiliary power isolation in control panel automation enclosures, the \u003cstrong\u003eOmron R7M-A40030-BS1\u003c\/strong\u003e (\u003cstrong\u003eMY4NJAC110120\u003c\/strong\u003e General Purpose Relay) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Code Designation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR7M-A40030-BS1: Commercial catalog order reference designation\u003c\/li\u003e\n\u003cli\u003eMY: Standard general-purpose plug-in power relay platform\u003c\/li\u003e\n\u003cli\u003e4: 4PDT (4 Form C) contact pole layout\u003c\/li\u003e\n\u003cli\u003eN: Built-in LED operation indicator mechanism\u003c\/li\u003e\n\u003cli\u003eJ: Plug-in terminal structure for mounting socket interfaces\u003c\/li\u003e\n\u003cli\u003eAC110\/120: Nominal coil excitation voltage rating (110 to 120 VAC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eR7M-A40030-BS1 (Alias: MY4NJAC110120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.035 kg (1.23 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Unit Dimensions\u003c\/td\u003e\n\u003ctd\u003e21.5 mm x 28 mm x 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 60 mm x 50 mm \u003ci\u003e(Shipping weight: 0.15 kg)\u003c\/i\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-55 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.1 VA (Coil power draw at 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e110 VAC to 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A at 250 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003e4PDT (4 Form C, 4PDT-NO\/NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver (Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003ePlug-in socket mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControl Backplane Integration \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe relay provides reliable physical isolation between low-voltage digital output cards and high-power load circuits across PLC control cabinets. Rapid contact switching times preserve system response speeds across Profinet \/ EtherNet\/IP deterministic networks during high-density I\/O density scaling routines. Upstream controller modules utilize stable backplane bus communication velocity Licences and uniform firmware flash compatibility to process field feedback signals without loop delays.\u003c\/p\u003e\n\u003ch3\u003ePackage Delivery Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x R7M-A40030-BS1 Power Relay Module\u003c\/li\u003e\n\u003cli\u003e1 x Protective Dust Cover Frame\u003c\/li\u003e\n\u003cli\u003e1 x Technical Specification Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSocket Integration \u0026amp; Panel Wiring Protocol\u003c\/h3\u003e\n\u003ch4\u003ePhysical Socket Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the relay pin terminal base vertically into a compatible DIN-rail socket until the plastic retaining clips lock firmly.\u003c\/li\u003e\n\u003cli\u003eEnsure at least 10 mm lateral spacing between adjacent relay sockets to ensure adequate heat dissipation under full load continuous duty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTerminal Wiring Directives\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect 110\/120 VAC control line wires directly to socket coil terminals A1 and A2.\u003c\/li\u003e\n\u003cli\u003eWire field load circuits across the numbered 4PDT contact screw terminals, ensuring continuous conductor currents remain under 5 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous current capacity per pole on this relay?\u003c\/p\u003e\n\u003cp\u003eEach silver contact pole handles a maximum continuous current rating of 5 A at 250 VAC or 125 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat coil excitation voltage range is required for operation?\u003c\/p\u003e\n\u003cp\u003eThe non-latching electromagnetic coil operates within an AC supply voltage range of 110 VAC to 120 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat contact arrangement is available inside the sealed housing?\u003c\/p\u003e\n\u003cp\u003eThe unit features a 4PDT (4 Form C) contact setup providing four independent NO and NC switching channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the relay physically attached inside a control cabinet?\u003c\/p\u003e\n\u003cp\u003eThe housing features plug-in spade terminals designed for snap-in mounting into standard matching DIN-rail sockets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the relay include an integral visual status indicator?\u003c\/p\u003e\n\u003cp\u003eYes, the MY4NJ variant incorporates an integrated LED indicator that illuminates when the coil is energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal power consumption of the AC drive coil?\u003c\/p\u003e\n\u003cp\u003eThe electromagnetic drive coil consumes approximately 1.1 VA during steady-state 110\/120 VAC excitation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat contact material is utilized for reliable switching performance?\u003c\/p\u003e\n\u003cp\u003eThe switching contacts are constructed from solid silver (Ag) alloy to ensure low contact resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this relay be mounted directly to a printed circuit board?\u003c\/p\u003e\n\u003cp\u003eNo, this specific plug-in terminal model requires a compatible relay socket for panel wire termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306622795949,"sku":"R7M-A40030-BS1","price":124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/r7m-a40030-bs1-1_2.jpg?v=1790392455"},{"product_id":"3g3mx2-a4075-zv1-omron-multi-function-compact-inverter-mx2-series","title":"3G3MX2-A4075-ZV1 Omron Multi-Function Compact Inverter MX2 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4075-ZV1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter utilized to execute precise 3-phase 400 V AC motor velocity and torque control across automated motion control platforms.\u003c\/p\u003e\n\u003ch3\u003eVariant Decoder \u0026amp; Ordering Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base designation for the MX2 Series compact inverter generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure framework (rated IP10 minimum) or closed wall-mount design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply class rating (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e075\u003c\/strong\u003e: Maximum applicable motor capacity of 7.5 kW under continuous heavy-duty load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Designated application-specific firmware option and specialized regional hardware variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Parameters \u0026amp; Mechanical Characteristics\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4075-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e26.0 cm x 14.0 cm x 15.5 cm (Shipping Weight: 6.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 kW rated motor output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum enclosure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Synchronization \u0026amp; Internal Microcode Execution\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture leverages backplane bus communication velocity licences to guarantee zero-lag axis coordination across Profinet and EtherNet\/IP deterministic networks. High-density I\/O handling facilitates rapid pulse sequence decoding up to 32 kHz. In-field firmware flash compatibility allows seamless parameter set transfers and driver synchronization without host control interruption.\u003c\/p\u003e\n\u003ch3\u003eStandard Box Shipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4075-ZV1 Drive Main Unit\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Shield Assembly Plate\u003c\/li\u003e\n\u003cli\u003e1 x Operator Quick Start Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Cabinet Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Clearance Requirements\u003c\/p\u003e\n\u003cp\u003eMount vertically on a flat heat-dissipating panel, maintaining 100 mm top and bottom clearance to facilitate forced-air thermal convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding \u0026amp; Cable Isolation\u003c\/p\u003e\n\u003cp\u003eEnclose motor power leads (U, V, W) in continuous 360-degree shielded conduit separate from control signaling wires by 100 mm minimum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround Terminal Termination\u003c\/p\u003e\n\u003cp\u003eBond the protective earth terminal directly to the main cabinet ground bus using high-gauge stranded copper cable to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Operations Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan main line terminals be disconnected while the inverter remains energized under load?\u003c\/p\u003e\n\u003cp\u003eNo. Input mains power must be isolated and DC bus capacitor voltage verified below 50 VDC prior to handling power block terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hardware response time is guaranteed upon triggering emergency stop safety terminals?\u003c\/p\u003e\n\u003cp\u003eDual safety inputs execute hardware gate shutdown within 10 milliseconds, instantly stripping output torque according to ISO 13849-1 Cat 3 PLd.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the RS485 communication transceiver withstand field noise transients?\u003c\/p\u003e\n\u003cp\u003eThe onboard serial interface uses internal galvanic isolation to eliminate common-mode noise and suppress differential line voltage transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the inverter capable of operating high-speed AC motors above nominal 60 Hz limits?\u003c\/p\u003e\n\u003cp\u003eYes. Configured internal parameters support output speeds up to 1000 Hz, provided motor insulation and mechanical bearing ratings permit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen is an external dynamic braking resistor mandatory for deceleration cycles?\u003c\/p\u003e\n\u003cp\u003eAn external resistor block is required when high-inertia load regenerative energy exceeds the thermal dissipation threshold of the built-in braking chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does ambient temperature derating affect continuous output current capacity?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be reduced by 2.5% per deg C for ambient enclosure temperatures rising above 40 deg C up to 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an auxiliary battery supply required to preserve parameter settings during blackout conditions?\u003c\/p\u003e\n\u003cp\u003eNo. User parameter files, custom logic sequences, and historical fault data are permanently recorded into non-volatile internal EEPROM storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal shielding method prevents analog reference drift on 4-20 mA control loops?\u003c\/p\u003e\n\u003cp\u003eTerminate the cable braid shield to the drive earth point only on the inverter side to eliminate differential ground potential currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306623123629,"sku":"3G3MX2-A4075-ZV1","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4075-zv1_1.jpg?v=1787722912"},{"product_id":"3g3jz-a2037-omron-sysdrive-3g3jz-series-inverter","title":"3G3JZ-A2037 Omron SYSDRIVE 3G3JZ Series Inverter","description":"\u003cp\u003eConfigured for pulse-width modulated motor speed regulation and torque output management in industrial automation drive loops, the \u003cstrong\u003eOmron 3G3JZ-A2037\u003c\/strong\u003e (\u003cstrong\u003e3G3JZ-A2037\u003c\/strong\u003e Inverter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Product series designation for compact SYSDRIVE inverter drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enclosure configuration indicating panel-mounting IP20 minimum closed wall mounting design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Input power supply voltage class representing 3-phase AC 200 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e037\u003c\/strong\u003e: Maximum applicable motor power output rating of 3.7 kW.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A2037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Motor Capacity\u003c\/td\u003e\n\u003ctd\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.7 kW drive output load capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 x 18.0 x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Connectivity \u0026amp; Parameter Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe inverter drive interfaces with fieldbus topologies via Modbus RS-485 serial communication routines, enabling deterministic control over drive operating profiles. System integration firmware ensures firmware flash compatibility validation during controller boot-up, while internal register maps facilitate rapid scaling across industrial I\/O density scaling nodes.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A2037 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective enclosure packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Field Wiring Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Installation Steps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the inverter vertically onto an upright metallic panel to facilitate unhindered vertical convection airflow.\u003c\/li\u003e\n\u003cli\u003eEnsure clear thermal dissipation margins of at least 100 mm above and below the drive housing.\u003c\/li\u003e\n\u003cli\u003eTorque all panel mounting hardware securely to prevent operational vibration displacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Line and Grounding Connection Rules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWire the 3-phase AC 200 V mains power supply to terminals L1, L2, and L3 using copper conductors.\u003c\/li\u003e\n\u003cli\u003eConnect motor leads T1, T2, and T3 using shielded power cabling terminated at the drive ground lug.\u003c\/li\u003e\n\u003cli\u003eMaintain complete physical separation between high-power AC motor output conductors and low-voltage control signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the supply voltage requirement for the 3G3JZ-A2037 drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive operates from a nominal 3-phase AC 200 V power source for 200 V class AC motor applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maximum motor capacity can be driven by this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe inverter is specified to control 3-phase induction motors with a rated capacity up to 3.7 kW.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs hot-swapping supported for the main power connection block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Main input power must be completely disconnected and DC bus capacitors discharged before servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is ground continuity established for the drive enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFrame grounding is achieved through dedicated protective earth terminal lugs connected to cabinet ground bars.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat enclosure ingress protection rating applies to this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features an IP20 minimum closed wall panel-mounting chassis design for control cabinet installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan control signal cables be run in the same conduit as motor power cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Control wires must be routed in a separate shielded conduit to eliminate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit handle communication timing with higher-level controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes onboard Modbus processing circuits to maintain steady RS-485 response times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat prevents parameter corruption during system firmware updates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAutomated firmware flash compatibility routines inspect incoming binary files before flashing drive EEPROM.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306627023021,"sku":"3G3JZ-A2037","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3JZ-A2037.jpg?v=1787719626"},{"product_id":"3g3mx2-a4040-zv1-omron-multi-function-compact-inverter-mx2-series","title":"3G3MX2-A4040-ZV1 Omron Multi-Function Compact Inverter MX2 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4040-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter, operates as a dedicated hardware component for 3-phase 400 V AC motor velocity and torque modulation within industrial drive network architectures.\u003c\/p\u003e\n\u003ch3\u003eProduct Code Structure \u0026amp; Variant Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: MX2 Series base inverter architecture platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting panel enclosure design (rated IP10 minimum) or closed wall-mounting configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC voltage class supply rating (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e040\u003c\/strong\u003e: Maximum applicable motor capacity of 4.0 kW under Heavy Duty (CT) rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Custom firmware feature build and region-specific functional specification variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Technical Data\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4040-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e14 cm x 12.8 cm x 17.05 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.0 kW rated output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Rating\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting IP10 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Firmware Flash Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture leverages backplane bus communication velocity licences to guarantee real-time speed coordination over EtherNet\/IP deterministic networks. High-density digital I\/O expansion scales control topology across multi-axis configurations. Field updates preserve firmware flash compatibility to synchronize local acceleration profiles with host controller drive commands without latency degradation.\u003c\/p\u003e\n\u003ch3\u003ePackage Dispatch Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4040-ZV1 Drive Unit\u003c\/li\u003e\n\u003cli\u003e1 x Main Power Input Terminal Cover Shield\u003c\/li\u003e\n\u003cli\u003e1 x Basic Technical Operations Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Cabling Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStandard Enclosure Setup\u003c\/p\u003e\n\u003cp\u003eMount vertically onto a flat, conductive metal backpanel to maintain low electrical impedance ground connections across the IP10 chassis frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductor \u0026amp; Shield Routing\u003c\/p\u003e\n\u003cp\u003eRoute 400 V three-phase power feed cables separate from low-voltage I\/O control wires by a minimum distance of 100 mm to prevent inductive cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Earthing Protocol\u003c\/p\u003e\n\u003cp\u003eConnect the protective earth terminal directly to the central panel earth busbar; avoid linking earth conductors sequentially across multiple inverter frames.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Operations FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed on the main power wiring terminals during system operation?\u003c\/p\u003e\n\u003cp\u003eNo. Input AC line power must be disconnected and the DC bus voltage checked to confirm complete discharge below 50 VDC prior to terminal servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat latency applies to internal safety circuit actuation upon drive shutdown signals?\u003c\/p\u003e\n\u003cp\u003eIntegrated dual safety inputs execute immediate hardware gate suppression, terminating power stage output torque within 10 milliseconds of trigger.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does backplane communication handle transient voltage spikes on serial bus channels?\u003c\/p\u003e\n\u003cp\u003eIsolated serial communication interfaces suppress differential voltage transients, maintaining bus stability without inducing processor reset cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive execute high-frequency output control routines above nominal line frequencies?\u003c\/p\u003e\n\u003cp\u003eYes. Configured firmware parameters allow output frequencies up to 1000 Hz, subject to thermal limits and motor insulation breakdown constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external dynamic braking configuration is required for high-inertia deceleration cycles?\u003c\/p\u003e\n\u003cp\u003eHigh-inertia applications require an external braking resistor tied to the dedicated DC terminals when kinetic energy exceeds internal sink capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does ambient temperature affect continuous load output ratings?\u003c\/p\u003e\n\u003cp\u003eContinuous output current must be linearly derated by 2.5% per deg C for ambient operation extending above 40 deg C up to 50 deg C max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes non-volatile parameter memory require an auxiliary battery back-up module?\u003c\/p\u003e\n\u003cp\u003eNo. Internal EEPROM structures store drive configuration parameters, logic commands, and operational fault logs permanently without external battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should analog input signals be grounded to avoid control reference noise interference?\u003c\/p\u003e\n\u003cp\u003eGround the shield wire of 0-10 VDC or 4-20 mA control loops at the drive side ground terminal only to prevent ground loop current generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306628268205,"sku":"3G3MX2-A4040-ZV1","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4040-zv1_2.jpg?v=1787722677"},{"product_id":"3g3mx2-a4022-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4022-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4022-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter, operates as a dedicated hardware component for 3-phase 400 V AC motor velocity and torque modulation within industrial drive network architectures.\u003c\/p\u003e\n\u003ch3\u003eProduct Designation \u0026amp; Suffix Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter platform code for the MX2 Series motion control range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply voltage class (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e022\u003c\/strong\u003e: Maximum applicable motor capacity of 2.2 kW under heavy-duty (CT) conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Customized application firmware option and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4022-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 cm x 12.8 cm x 14.35 cm (Shipping Weight: 4.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.2 kW rated output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP10 panel-mounting minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Network Interoperability\u003c\/h3\u003e\n\u003cp\u003eThe inverter integrates deterministic EtherNet\/IP and Modbus RTU communication interfaces to maintain real-time speed coordination. Microprocessor logic scales I\/O density to evaluate pulse sequence inputs up to 32 kHz without expansion modules. Firmware flash compatibility enables direct parameter synchronization across host controllers while maintaining deterministic backplane execution loops.\u003c\/p\u003e\n\u003ch3\u003ePackage Delivery Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4022-ZV1 Compact Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Main Terminal Protection Shield\u003c\/li\u003e\n\u003cli\u003e1 x Technical Instruction Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Positioning\u003c\/p\u003e\n\u003cp\u003eMount vertically onto a flat metal backplate, ensuring a minimum clearance of 100 mm above and below the heat sink to enable natural air convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Noise Suppression\u003c\/p\u003e\n\u003cp\u003eIsolate 400 V AC power conductors from low-voltage DC control lines and analog signal lines by at least 100 mm to suppress inductive cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarthing Protocol\u003c\/p\u003e\n\u003cp\u003eConnect a low-impedance ground conductor directly from the protective earth terminal to the primary cabinet ground point; do not series-loop earth connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Hardware Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan power block terminals be rewired while main line voltage remains connected?\u003c\/p\u003e\n\u003cp\u003eNo. Input power must be disconnected and DC bus voltage verified below 50 VDC using a calibrated meter before handling wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat delay occurs when triggering the built-in hardware safety inputs?\u003c\/p\u003e\n\u003cp\u003eIntegrated dual safety inputs execute hardware gate shutdown within 10 milliseconds, terminating motor output torque in compliance with ISO 13849-1 Cat 3 PLd.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the RS485 communication transceiver withstand industrial line noise?\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation on the serial communication interface isolates internal logic from common-mode noise spikes and ground potential differences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive execute high-frequency output operations above standard line limits?\u003c\/p\u003e\n\u003cp\u003eYes. Configured internal parameters permit output frequency operation up to 1000 Hz, provided motor insulation and mechanical limits allow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external dynamic braking resistor required for low-inertia stop profiles?\u003c\/p\u003e\n\u003cp\u003eNo. The built-in braking chopper manages low-inertia stopping; an external resistor is required only when regenerative energy exceeds internal dissipation capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does elevated ambient temperature affect continuous current output ratings?\u003c\/p\u003e\n\u003cp\u003eContinuous output current must be derated by 2.5% per deg C for operating environments continuously exceeding 40 deg C up to 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes non-volatile memory require an auxiliary battery module for parameter persistence?\u003c\/p\u003e\n\u003cp\u003eNo. Logic parameters, configuration settings, and fault logs are stored permanently in internal EEPROM memory without battery dependency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding method prevents signal distortion on analog control channels?\u003c\/p\u003e\n\u003cp\u003eTerminate the cable braid shield at the inverter side ground terminal only to avoid creating ground loop currents across remote reference sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306631282861,"sku":"3G3MX2-A4022-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4022-zv1_2.jpg?v=1787722263"},{"product_id":"3g3mx2-a4015-zv1-omron-multi-function-compact-inverter-mx2-series","title":"3G3MX2-A4015-ZV1 Omron Multi-Function Compact Inverter MX2 Series","description":"\u003cp\u003eConfigured for precise 3-phase 400 V AC motor velocity and torque modulation in automated drive architectures, the \u003cstrong\u003eOmron 3G3MX2-A4015-ZV1\u003c\/strong\u003e (\u003cstrong\u003e3G3MX2\u003c\/strong\u003e) Multi-Function Compact Inverter provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown \u0026amp; Structural Decoding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter hardware platform for the MX2 industrial drive series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply voltage class (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e015\u003c\/strong\u003e: Maximum applicable motor capacity of 1.5 kW under continuous heavy-duty (CT) conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Customized application firmware option and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Technical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4015-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 cm x 12.8 cm x 14.35 cm (Shipping Weight: 4.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 kW rated output motor capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum enclosure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Firmware Processing\u003c\/h3\u003e\n\u003cp\u003eThe unit leverages internal backplane bus communication velocity licences to maintain deterministic real-time speed synchronization over EtherNet\/IP and Modbus RTU networks. Flexible I\/O density scaling accepts high-frequency pulse sequence inputs up to 32 kHz. System microcode ensures firmware flash compatibility across host controllers, preventing signal dropouts during multi-axis execution.\u003c\/p\u003e\n\u003ch3\u003eDeliverables \u0026amp; Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4015-ZV1 Drive Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Power Terminal Protection Shield\u003c\/li\u003e\n\u003cli\u003e1 x Technical Installation Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Electrical Connections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCabinet Positioning Rules\u003c\/p\u003e\n\u003cp\u003eMount the unit vertically onto a flat metal backplate, maintaining at least 100 mm top and bottom space for unhindered airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Noise Suppression\u003c\/p\u003e\n\u003cp\u003eIsolate 400 V main power lines from low-voltage I\/O lines by at least 100 mm distance to avoid electromagnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround Terminal Connection\u003c\/p\u003e\n\u003cp\u003eRun a low-impedance grounding wire directly from the ground terminal to the main earth point; do not series-loop ground cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan terminal connections be modified while input power is active?\u003c\/p\u003e\n\u003cp\u003eNo. Input power must be disconnected and DC bus voltage verified below 50 VDC using a multimeter prior to handling any terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat execution time applies to emergency stop input activation?\u003c\/p\u003e\n\u003cp\u003eDual safety inputs execute hardware gate suppression within 10 milliseconds, stripping output torque per ISO 13849-1 Cat 3 PLd rules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the RS485 communication interface resist industrial noise spikes?\u003c\/p\u003e\n\u003cp\u003eThe onboard RS485 port incorporates galvanic isolation, preventing common-mode noise and differential ground potential offsets from interrupting communications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive operate high-frequency motors above standard line limits?\u003c\/p\u003e\n\u003cp\u003eYes. Adjustable parameter profiles allow output operation up to 1000 Hz, assuming motor bearings and winding insulation withstand high frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external dynamic braking resistor mandatory for low-inertia stop cycles?\u003c\/p\u003e\n\u003cp\u003eNo. Internal braking transistors absorb low-inertia energy; external resistors are required only when regenerative energy exceeds internal thermal dissipation capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does high ambient temperature affect continuous current output ratings?\u003c\/p\u003e\n\u003cp\u003eContinuous current ratings must be derated by 2.5% per deg C for operating environments exceeding 40 deg C up to 50 deg C max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes parameter storage require an auxiliary battery back-up unit?\u003c\/p\u003e\n\u003cp\u003eNo. Parameters, internal drive sequences, and fault logs are stored permanently in internal non-volatile EEPROM memory without battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding protocol prevents analog reference noise on control lines?\u003c\/p\u003e\n\u003cp\u003eGround the shield braid of 0-10 VDC or 4-20 mA control loops at the drive side ground terminal only to prevent ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306638262445,"sku":"3G3MX2-A4015-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4015-zv1_3.jpg?v=1787722140"},{"product_id":"3g3mx2-a4150-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4150-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eConfigured for high-torque 3-phase 400 V AC motor velocity regulation and dynamic drive execution in automated motion architectures, the \u003cstrong\u003eOmron 3G3MX2-A4150-ZV1\u003c\/strong\u003e (\u003cstrong\u003e3G3MX2\u003c\/strong\u003e) Multi-Function Compact Inverter provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; System Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base platform code for the MX2 Series compact inverter generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC voltage supply class rating (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150\u003c\/strong\u003e: Maximum applicable motor capacity of 15 kW under Heavy Duty (CT) loading profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Application-specific firmware integration option and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4150-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 18.0 cm x 17.55 cm (Shipping Weight: 8.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 kW rated motor output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum enclosure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Communication \u0026amp; Firmware Microcode Execution\u003c\/h3\u003e\n\u003cp\u003eThe internal drive control unit processes real-time bus commands via EtherNet\/IP deterministic networks and Modbus RTU serial links. Internal architecture leverages backplane bus communication velocity licences to maintain cycle synchronization without packet jitter. High I\/O density scaling accepts pulse sequence input frequencies up to 32 kHz, while firmware flash compatibility allows direct parameter flashing from host PLC software environments.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4150-ZV1 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x High-Voltage Terminal Protective Cover\u003c\/li\u003e\n\u003cli\u003e1 x System Installation \u0026amp; Wiring Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFrame Mounting Guidelines\u003c\/p\u003e\n\u003cp\u003eSecure the unit vertically onto a rigid metallic panel using M5 mounting hardware, providing at least 100 mm vertical clearance above and below the heat sink for unhindered forced-air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLine Conductor \u0026amp; Signal Separation\u003c\/p\u003e\n\u003cp\u003eMaintain a physical separation distance of at least 100 mm between primary 400 V AC power conductors and 24 VDC I\/O or analog control wires to suppress electromagnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Interface Rules\u003c\/p\u003e\n\u003cp\u003eRun a direct low-impedance ground lead from the protective earth terminal to the main panel earthing bar. Do not daisy-chain ground lines between multiple drive chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Hardware Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan main power input terminals be wired while the supply line remains active?\u003c\/p\u003e\n\u003cp\u003eNo. Primary AC supply line isolation must be confirmed and internal DC bus capacitor voltage measured below 50 VDC prior to accessing terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal propagation delay occurs when the dual hardware safety inputs are triggered?\u003c\/p\u003e\n\u003cp\u003eThe integrated safety inputs execute direct gate driver disable within 10 milliseconds, stripping output motor torque in compliance with ISO 13849-1 Cat 3 PLd standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal serial interface resist industrial line surge transients?\u003c\/p\u003e\n\u003cp\u003eThe onboard RS485 communication port uses integrated galvanic isolation barriers to prevent differential ground potential offsets and common-mode noise corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the inverter unit capable of driving high-speed motor spindles exceeding 60 Hz limits?\u003c\/p\u003e\n\u003cp\u003eYes. Configurable microcode registers allow output frequency scaling up to 1000 Hz, provided motor mechanical speed ratings and winding insulation permit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen is an external dynamic braking resistor required for deceleration cycles?\u003c\/p\u003e\n\u003cp\u003eAn external braking resistor must be wired to the DC bus terminals when high-inertia load regenerative energy exceeds the thermal dissipation limits of the internal chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current derating factor applies during continuous high-ambient temperature operation?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be reduced by 2.5% per deg C for ambient operating environments continuously exceeding 40 deg C up to 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes non-volatile memory require an auxiliary battery module for parameter persistence?\u003c\/p\u003e\n\u003cp\u003eNo. Parameter configurations, user-programmed sequence files, and historical fault data are permanently recorded in non-volatile internal EEPROM storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding method prevents analog reference voltage drift on 4-20 mA control loops?\u003c\/p\u003e\n\u003cp\u003eGround the cable braid shield to the drive earth point only at the inverter end. Leaving the remote end ungrounded prevents loop currents from corrupting control signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306640621741,"sku":"3G3MX2-A4150-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4150-zv1_1.jpg?v=1787723092"},{"product_id":"3g3mx2-a2007-v2-omron-multi-function-compact-inverter-mx2-series","title":"3G3MX2-A2007-V2 Omron Multi-function Compact Inverter MX2 Series","description":"\u003cp\u003eConfigured for precise 3-phase AC motor velocity and torque control in automated drive systems, the \u003cstrong\u003eOmron 3G3MX2-A2007-V2\u003c\/strong\u003e (\u003cstrong\u003e3G3MX2-A2007\u003c\/strong\u003e) Multi-function Compact Inverter provides direct physical and electrical execution. It processes 200 VAC three-phase inputs to drive induction motors up to 0.75 kW under heavy-duty constant torque conditions.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Identification Coding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: MX2-Series V2 base platform architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA2\u003c\/strong\u003e: 3-phase 200 VAC power supply class (200 V to 240 V rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e007\u003c\/strong\u003e: Maximum applicable motor capacity of 0.75 kW (Heavy Duty \/ CT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV2\u003c\/strong\u003e: Enhanced V2 hardware and firmware generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV1\u003c\/strong\u003e: Regional designation code covering Japan and areas excluding China and Europe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A2007-V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.8 cm x 6.8 cm x 14.55 cm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.75 kW motor output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e3-phase 200 VAC to 240 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz to 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural convection \/ heat sink cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Connectivity \u0026amp; Firmware Logic\u003c\/h3\u003e\n\u003cp\u003eThe Omron MX2 V2 series integrates deterministic fieldbus network options alongside high-speed backplane serial bus communications. Microcode processing ensures firmware flash compatibility across standard PLC controllers via Modbus RTU, EtherNet\/IP, and EtherCAT expansion options. High I\/O density scaling allows direct pulse train inputs up to 32 kHz, enabling precise speed synchronization without dedicated encoder feedback cards.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A2007-V2 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Cover Shield Kit\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Manual Document Set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit vertically on a flat, vibration-free surface ensuring minimum 10 cm top and bottom clearance for heat dissipation.\u003c\/li\u003e\n\u003cli\u003eUse 360-degree shielded cable clamps for all motor output leads (U, V, W) to prevent radiated high-frequency noise.\u003c\/li\u003e\n\u003cli\u003eConnect a dedicated low-impedance safety ground wire to the protective earth terminal (PE); do not daisy-chain ground lines.\u003c\/li\u003e\n\u003cli\u003eKeep control signal wiring separated from primary 200 V AC power cables by at least 100 mm to suppress inductive cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the inverter support hot-swappable installation during main power operation?\u003c\/p\u003e\n\u003cp\u003eNo. Main input power must be completely disconnected and DC bus voltage allowed to discharge fully below 50 VDC prior to servicing wiring or control terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response latency when executing emergency stop function inputs?\u003c\/p\u003e\n\u003cp\u003eThe built-in dual safety inputs comply with ISO 13849-1 Cat 3 PLd, cutting motor torque output within 10 milliseconds upon hardware signal assertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive execute high-frequency output operations above standard induction limits?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware settings permit output frequencies up to 1000 Hz for high-speed spindles, provided motor mechanical insulation limits are fully validated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does backplane communication handle transient voltage spikes on RS485 lines?\u003c\/p\u003e\n\u003cp\u003eThe RS485 Modbus port incorporates galvanic isolation rated to withstand differential signal surges and common-mode noise spikes without processor reset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external braking resistor mandatory for standard stop routines?\u003c\/p\u003e\n\u003cp\u003eNo. An internal braking transistor is integrated; an external resistor is required only when dynamic deceleration energy exceeds internal thermal dissipation limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal derating factor applies at maximum ambient operating temperatures?\u003c\/p\u003e\n\u003cp\u003eThe rated output current must be derated by 2% per deg C when operating in ambient environments continuously exceeding 40 deg C up to 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit retain programmed PLC parameters during extended power losses?\u003c\/p\u003e\n\u003cp\u003eYes. User logic programs, parameters, and fault logs are written to non-volatile EEPROM memory, ensuring full data retention without battery backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shield grounding methodology is recommended for analogue input channels?\u003c\/p\u003e\n\u003cp\u003eConnect the shield of the 0-10 VDC or 4-20 mA analogue control line at the inverter end only to prevent ground loop currents from corrupting reference values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306644586669,"sku":"3G3MX2-A2007-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3MX2-A2007-V2.jpg?v=1787721558"},{"product_id":"3g3mx2-a4015-zv1-omron-frequency-inverter-mx2-series","title":"3G3MX2-A4015-ZV1 Omron Frequency Inverter MX2 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4015-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2-A4015\u003c\/strong\u003e Frequency Inverter, operates as a dedicated hardware component for open-loop motor speed regulation and torque control within industrial drive network architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: MX2 Series compact inverter platform designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA4\u003c\/strong\u003e: 3-phase 380 to 480 VAC input voltage class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e015\u003c\/strong\u003e: 1.5 kW max applicable motor capacity rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Integrated internal software and parameter functionality revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Performance Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4015-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 kW (Rated motor output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 to 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 to 480 VAC (Cannot exceed input voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Resistor Duty Cycle\u003c\/td\u003e\n\u003ctd\u003eBRD usage is 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Suppression Option\u003c\/td\u003e\n\u003ctd\u003e3G3AX-NFI23 (CT rating supported only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Methods\u003c\/td\u003e\n\u003ctd\u003eOpen loop torque control, PID control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Fieldbus Integration \u0026amp; Motor Drive Dynamics\u003c\/h3\u003e\n\u003cp\u003eHigh starting torque and vector control capabilities in open loop mode deliver precise machine dynamics and motion profiles. The drive supports open network fieldbus communication options, enabling real-time status exchange and setpoint transfer over EtherNet\/IP deterministic networks. Backplane bus communication velocity across optional option cards ensures low-latency register access, while firmware flash compatibility guarantees predictable motor speed response during multi-axis synchronization.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4015-ZV1 Frequency Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Front Control Keypad Interface\u003c\/li\u003e\n\u003cli\u003e1 x Cable Grounding Plate Kit\u003c\/li\u003e\n\u003cli\u003e1 x Quick Start Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Clearance\u003c\/strong\u003e: Mount the unit vertically on a flat panel inside an IP54 or higher control cabinet, maintaining a minimum 100 mm top and bottom clearance for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Line Reactor Wiring\u003c\/strong\u003e: Connect an optional AC reactor to the main supply lines to suppress harmonic current generated from the inverter, especially if power supply capacity exceeds drive capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Choke Configuration\u003c\/strong\u003e: Install a DC reactor across the internal DC link terminals for improved harmonic mitigation compared to standard AC line reactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor \u0026amp; Line Grounding\u003c\/strong\u003e: Route input power cables (3-phase 380 to 480 VAC) and motor power leads in separate grounded metallic conduits to avoid high-frequency noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat limits exist on the maximum output voltage supplied to the AC motor?\u003c\/p\u003e\n\u003cp\u003eThe output voltage ranges up to 3-phase 380 to 480 VAC and cannot exceed the incoming line voltage under any operational state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat constraint applies when using the 3G3AX-NFI23 filter option with this drive?\u003c\/p\u003e\n\u003cp\u003eWhen configured with the 3G3AX-NFI23 noise filter option, only the Heavy Duty (CT) rating specification is supported.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable duty cycle for internal dynamic braking?\u003c\/p\u003e\n\u003cp\u003eThe built-in dynamic braking transistor circuit operates with a maximum braking resistor duty cycle (BRD usage) of 10%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can harmonic current generation be minimized effectively?\u003c\/p\u003e\n\u003cp\u003eA DC reactor suppresses harmonic current better than an AC reactor, and both components can be installed simultaneously for maximum reduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen should an AC reactor be connected to the AC power input lines?\u003c\/p\u003e\n\u003cp\u003eConnect an AC reactor if power supply capacity greatly exceeds inverter rating, or if power factor improvement is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the inverter support closed-loop encoder feedback for speed control?\u003c\/p\u003e\n\u003cp\u003eThe drive delivers high starting torque and precise torque regulation strictly in open loop mode without requiring encoder feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat process control features are integrated directly into the firmware?\u003c\/p\u003e\n\u003cp\u003eThe unit features internal PID control, multi-step speed selection, starting frequency adjustment, carrier frequency adjustment, and jogging operation modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are fieldbus communications integrated into the drive platform?\u003c\/p\u003e\n\u003cp\u003eOptional communication cassettes interface directly with major open network systems, connecting the drive to field controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306649436333,"sku":"3G3MX2-A4015-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3g3mx2-a4015-zv1_1_3.jpg?v=1790391946"},{"product_id":"3g3mx2-a4055-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4055-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4055-ZV1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter utilized to execute 3-phase 400 V AC motor velocity control and real-time torque regulation across industrial automation drive platforms.\u003c\/p\u003e\n\u003ch3\u003eVariant Decoder \u0026amp; System Catalog Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter hardware platform for the MX2 Series drive architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply voltage class (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e055\u003c\/strong\u003e: Maximum applicable motor capacity of 5.5 kW under continuous heavy-duty (CT) loading profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Dedicated firmware integration profile and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4055-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e14.0 cm x 18.0 cm x 17.0 cm (Shipping Weight: 6.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.5 kW rated output motor capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Input Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum panel-mounting enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Execution Logic\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture leverages backplane bus communication velocity licences to preserve cycle synchronization across Profinet and EtherNet\/IP deterministic networks. Embedded control loops manage high I\/O density scaling, enabling direct processing of pulse train references up to 32 kHz. System microcode guarantees firmware flash compatibility across host controller platforms, preventing signal frame latency during coordinated multi-axis execution.\u003c\/p\u003e\n\u003ch3\u003eOrdering \u0026amp; Deliverable Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4055-ZV1 Drive Unit\u003c\/li\u003e\n\u003cli\u003e1 x Protective Terminal Guard\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instructions Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Clearance Rules\u003c\/p\u003e\n\u003cp\u003eMount the unit vertically against a metal panel backplate, maintaining at least 100 mm clearance above and below the cooling heatsink to ensure adequate thermal airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Routing Protocol\u003c\/p\u003e\n\u003cp\u003eMaintain a physical separation distance of at least 100 mm between 400 V AC power leads and low-voltage DC control wires to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Earthing Connection\u003c\/p\u003e\n\u003cp\u003eConnect a dedicated grounding wire directly from the protective earth terminal to the main panel ground bus; do not series-loop earth connections across multiple units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan terminal block connections be altered while power is supplied to the drive?\u003c\/p\u003e\n\u003cp\u003eNo. Main AC power must be disconnected and internal DC bus voltage verified below 50 VDC using a multimeter before touching terminal screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat activation time applies to the internal dual safety input system?\u003c\/p\u003e\n\u003cp\u003eDual safety inputs execute direct gate driver shutdown within 10 milliseconds, removing motor torque in compliance with ISO 13849-1 Cat 3 PLd standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal serial interface resist industrial line noise spikes?\u003c\/p\u003e\n\u003cp\u003eThe integrated RS485 communication transceiver features galvanic isolation, shielding internal logic from differential ground offsets and common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the drive capable of operating high-frequency motors above standard mains limits?\u003c\/p\u003e\n\u003cp\u003eYes. Adjustable internal registers allow output operation up to 1000 Hz, provided motor winding insulation and mechanical bearings tolerate high frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external dynamic braking unit required for low-inertia stop cycles?\u003c\/p\u003e\n\u003cp\u003eNo. Internal braking choppers manage standard stopping; external resistors are required only when high-inertia load regeneration exceeds thermal capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does high ambient temperature affect continuous current output capacity?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be derated by 2.5% per deg C for operating environments continuously exceeding 40 deg C up to 50 deg C max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal configuration parameters preserved across total primary power loss cycles?\u003c\/p\u003e\n\u003cp\u003eYes. Drive parameters, custom V\/f profiles, and error history logs are permanently stored in internal non-volatile EEPROM memory without battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding rule prevents signal distortion on analog reference control lines?\u003c\/p\u003e\n\u003cp\u003eGround the braided cable shield to the drive earth terminal on the inverter side only to prevent circulating ground loop currents from skewing signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306651467949,"sku":"3G3MX2-A4055-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3MX2-A4055-ZV1_1.jpg?v=1787722798"},{"product_id":"3g3jz-a40-omron-sysdrive-3g3jz-series-inverter","title":"3G3JZ-A40 Omron SYSDRIVE 3G3JZ Series Inverter","description":"\u003cp\u003eConfigured for pulse-width modulated variable frequency motor regulation and torque management in industrial drive control loops, the \u003cstrong\u003eOmron 3G3JZ-A40\u003c\/strong\u003e (\u003cstrong\u003e3G3JZ-A40\u003c\/strong\u003e Inverter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Number Nomenclature\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Product series designation for compact SYSDRIVE AC variable frequency drive units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware enclosure rating denoting panel-mounting IP20 minimum closed wall mounting design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40\u003c\/strong\u003e: Operating input supply line voltage specification indicating 3-phase AC 400 V power class.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Operating Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoad-dependent 400 V drive power output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 x 18.0 x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Communication \u0026amp; Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe drive interfaces with host control systems using Modbus RS-485 serial communications, facilitating parameter synchronization across Profinet \/ EtherNet\/IP deterministic networks via external fieldbus gateways. Internal logic circuits manage drive profile execution and perform automated firmware flash compatibility verification on power-up to ensure register data consistency across multi-node drive systems.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A40 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Protective anti-static inner packaging wrap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Field Installation Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the inverter chassis vertically on a flat, grounded metallic cabinet backpanel.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum thermal ventilation clearance of 100 mm above and below the housing.\u003c\/li\u003e\n\u003cli\u003eSecure mounting screws to standard torque settings to prevent vibration loosening during operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring Practices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect incoming 3-phase AC 400 V power mains lines directly to terminals L1, L2, and L3.\u003c\/li\u003e\n\u003cli\u003eRoute motor power cabling from terminals T1, T2, and T3 using continuous shielded cable.\u003c\/li\u003e\n\u003cli\u003eConnect the chassis earth terminal directly to the enclosure frame grounding rail using a short copper conductor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage class is required for the 3G3JZ-A40 drive unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive requires a nominal 3-phase AC 400 V input power supply for 400 V class AC motor control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs main power terminal hot-swapping permitted during system operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Input line power must be completely disconnected and internal DC bus capacitors discharged prior to servicing power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat enclosure protection level does the inverter chassis provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features an IP20 minimum panel-mounting enclosure design built for installation within closed control panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is electrical noise suppressed on low-voltage control conductors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControl wiring must use twisted-pair shielded cables kept physically separate from AC mains power lines and motor leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is chassis earth ground continuity established inside the panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding connects directly from the drive protective earth lug to the main enclosure grounding rail via copper wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit interface with higher-level PLC control networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe inverter communicates via onboard Modbus RS-485 interfaces linked to higher-level automation network gateways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system safety checks run during initial startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem initialization routines perform automated firmware flash compatibility verification prior to enabling PWM switching outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting orientation is required for adequate drive cooling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe inverter must be installed vertically inside the enclosure to enable natural air convection through the heat sink channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306656841901,"sku":"3G3JZ-A40","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3JZ-A40_1.jpg?v=1787719691"},{"product_id":"3g3jz-a4015-omron-variable-frequency-drive-sysdrive-3g3jz-series","title":"3G3JZ-A4015 Omron Variable Frequency Drive SYSDRIVE 3G3JZ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3JZ-A4015\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3JZ\u003c\/strong\u003e Variable Frequency Drive, operates as a dedicated hardware component for 3-phase AC motor speed regulation within SYSDRIVE 3G3JZ automation networks.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Code Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Base inverter series designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting panel enclosure rated for minimum IP20 wall enclosure execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase AC 400 V supply voltage class (380 V to 480 V operating ceiling).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e015\u003c\/strong\u003e: Maximum applicable motor rating of 1.5 kW output capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Hardware Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm x 150 mm x 175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Class\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 380 V to 480 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Motor Output\u003c\/td\u003e\n\u003ctd\u003e1.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 panel-mounting \/ closed wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 kW nominal drive rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Memory Interface\u003c\/h3\u003e\n\u003cp\u003eThe internal logic card integrates dedicated backplane bus communication velocity processing to maintain real-time Modbus register exchange across industrial networks. System memory supports firmware flash compatibility, preventing register mapping offset errors during firmware synchronization across external controller interfaces.\u003c\/p\u003e\n\u003ch3\u003eIncluded Standard Component Kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4015 VFD Inverter drive\u003c\/li\u003e\n\u003cli\u003e1 x Concise field wiring instruction guide sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation \u0026amp; Cabling Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePanel Clearance\u003c\/p\u003e\n\u003cp\u003ePosition vertically on an unpainted mounting surface, maintaining at least 100 mm top and bottom space for unhindered convection airflow through the thermal heatsink.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Separation\u003c\/p\u003e\n\u003cp\u003eIsolate high-voltage AC motor lines from low-voltage 0-10 VDC \/ 4-20 mA control signal wiring by a minimum physical distance of 200 mm to prevent electromagnetic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding Termination\u003c\/p\u003e\n\u003cp\u003eGround all braided motor cable shields directly to the chassis earthing stud via low-impedance copper clamps before applying input line voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage threshold does the 3G3JZ-A4015 drive accept?\u003c\/p\u003e\n\u003cp\u003eThe power input section accepts standard 3-phase 380 VAC to 480 VAC supplies at frequencies ranging from 50 Hz to 60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat protection degree is provided by the drive enclosure?\u003c\/p\u003e\n\u003cp\u003eThe chassis complies with IP20 ingress protection standards, requiring installation inside clean, dust-free industrial control panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should analog speed control inputs be wired to prevent noise?\u003c\/p\u003e\n\u003cp\u003eAnalog 0-10 VDC or 4-20 mA command wires must use twisted shielded pair cables, grounded exclusively at the drive frame earth terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the continuous rated output current capacity of this 1.5 kW model?\u003c\/p\u003e\n\u003cp\u003eThe inverter delivers a continuous rated output current of 4.2 A to drive standard 3-phase induction motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the inverter support parameter transfer via digital keypad?\u003c\/p\u003e\n\u003cp\u003eIntegrated front panel digital operator keypads permit localized parameter setting, fault diagnostics reading, and frequency reference adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for power or terminal block connections?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting power supply lines or terminal cables while voltage is applied damages the power stage and internal logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cooling method is used to dissipate heat generated during operation?\u003c\/p\u003e\n\u003cp\u003eHeat dissipation is managed via internal forced-air fan circulation directed across heavy-duty aluminum heatsink fins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature conditions are required for continuous operation?\u003c\/p\u003e\n\u003cp\u003eOperating environments must maintain non-condensing relative humidity within an ambient temperature span of -10 deg C to +50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306657595565,"sku":"3G3JZ-A4015","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4015_1.jpg?v=1787720044"},{"product_id":"omron-3g3jz-a4037-sysdrive-3g3jz-series-inverter","title":"Omron 3G3JZ-A4037 SYSDRIVE 3G3JZ Series Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3JZ-A4037\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3JZ-A4037\u003c\/strong\u003e Inverter, operates as a dedicated hardware component for pulse-width modulated motor speed control and torque regulation within SYSDRIVE automation platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Base family prefix for compact SYSDRIVE AC variable frequency drive units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure design conforming to IP20 minimum closed wall mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: Operating input voltage specification designated for 3-phase AC 400 V power networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e037\u003c\/strong\u003e: Maximum drive power capacity scaled for 3.7 kW induction motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Class\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Capacity\u003c\/td\u003e\n\u003ctd\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.7 kW full load power output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 x 18.0 x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Protocol \u0026amp; Deterministic Control\u003c\/h3\u003e\n\u003cp\u003eThe drive interfaces with PLC host controllers over Modbus RS-485 interfaces to support deterministic networks and real-time parameter configuration. Onboard control logic executes firmware flash compatibility validation upon system power-up to ensure seamless drive control and optimal I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eComponent Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4037 Inverter Module\u003c\/li\u003e\n\u003cli\u003e1 x ESD protective chassis wrap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the inverter in an upright vertical orientation on a grounded metal backpanel.\u003c\/li\u003e\n\u003cli\u003eMaintain an unimpeded thermal clearance of at least 100 mm above and below the drive chassis.\u003c\/li\u003e\n\u003cli\u003eTighten panel mounting screws securely to satisfy vibration resistance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate incoming 3-phase AC 400 V power lines to terminals L1, L2, and L3.\u003c\/li\u003e\n\u003cli\u003eAttach three-phase motor leads to terminals T1, T2, and T3 using continuous shielded cable.\u003c\/li\u003e\n\u003cli\u003eGround the drive frame directly to the main enclosure earth bus bar using heavy copper wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage range does the 3G3JZ-A4037 drive accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive requires a nominal 3-phase AC 400 V input voltage source for 400 V class AC motor control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor power output rating is supported by this inverter model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis inverter model provides drive output capacity tailored for 3-phase AC motors rated up to 3.7 kW.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs power terminal hot-swapping allowed on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Input power must be turned off and DC link capacitors discharged prior to servicing power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the internal control board protected from electrical noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControl lines must use twisted-pair shielded cables separated from motor wiring to avoid interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat structural enclosure protection does this inverter supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features an IP20 minimum panel-mounting enclosure designed for closed wall cabinet mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is cabinet grounding executed for safety and noise suppression?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding connects from the dedicated PE terminal directly to the enclosure grounding rail via copper strap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit handle protocol communication timing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntegrated serial logic maintains deterministic control timing over Modbus RS-485 network connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat checks occur when replacing or updating drive firmware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem initialization routines run firmware flash compatibility checks prior to executing motor control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306657923245,"sku":"3G3JZ-A4037","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4037_2.jpg?v=1787720290"},{"product_id":"3g3jz-a2015-omron-sysdrive-3g3jz-series-inverter","title":"3G3JZ-A2015 Omron SYSDRIVE 3G3JZ Series Inverter","description":"\u003cp\u003eConfigured for pulse-width modulated AC motor speed control and torque output regulation in industrial automation drive loops, the \u003cstrong\u003eOmron 3G3JZ-A2015\u003c\/strong\u003e (\u003cstrong\u003e3G3JZ-A2015\u003c\/strong\u003e Inverter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Base product family identifier for compact SYSDRIVE AC variable frequency drive units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware enclosure configuration indicating panel-mounting IP20 minimum \/ closed wall mounting design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Input line voltage specification designated for 3-phase AC 200 V power networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e015\u003c\/strong\u003e: Maximum rated motor drive output capacity specified for 1.5 kW induction motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 kW full load drive output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 x 18.0 x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Connectivity \u0026amp; Integrated Drive Logic\u003c\/h3\u003e\n\u003cp\u003eThe drive interfaces with host controllers using onboard RS-485 Modbus communications, enabling integration into Profinet \/ EtherNet\/IP deterministic networks via external fieldbus gateways. Internal microcontrollers govern drive I\/O density scaling routines and execute real-time firmware flash compatibility checks on initialization to ensure system-wide register integrity.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Inclusions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A2015 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective inner packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting \u0026amp; Field Installation Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mount Recommendations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the drive unit in a vertical orientation onto a flat metal panel using specified mounting holes.\u003c\/li\u003e\n\u003cli\u003eMaintain a clearance gap of at least 100 mm above and below the drive housing for vertical thermal ventilation.\u003c\/li\u003e\n\u003cli\u003eTorquing panel attachment fasteners securely prevents physical degradation caused by continuous operational vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate incoming 3-phase AC 200 V mains lines to power input terminals L1, L2, and L3.\u003c\/li\u003e\n\u003cli\u003eConnect three-phase motor supply conductors to terminals T1, T2, and T3 using continuous shielded cable.\u003c\/li\u003e\n\u003cli\u003eSecure the frame earth wire to the main enclosure grounding bar to enforce equipotential bonding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input supply voltage is required for the 3G3JZ-A2015 drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive requires a nominal 3-phase AC 200 V power source for 200 V class AC induction motor loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maximum motor output rating can this inverter control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific drive model is engineered to power 3-phase induction motors with a maximum capacity of 1.5 kW.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the main power terminal block be hot-swapped under load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Main input power must be completely disconnected and internal DC bus capacitors discharged prior to servicing wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is electrical noise suppressed on control circuit cabling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControl lines must utilize twisted-pair shielded conductors routed away from high-power AC motor output cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat ingress protection level does the drive chassis provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features an IP20 minimum panel-mounting enclosure design built for installation within closed wall cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is cabinet ground continuity established during mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding connects directly from the drive protective earth lug to the cabinet grounding bar using a low-impedance conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the inverter maintain network timing during data transmission?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntegrated serial communication logic handles protocol timing over Modbus RS-485 interfaces connected to field networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat validation process prevents invalid parameter loading during boot-up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem initialization routines perform automated firmware flash compatibility verification prior to enabling drive output execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306658218157,"sku":"3G3JZ-A2015","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a2015_1.jpg?v=1787719296"},{"product_id":"omron-3g3jz-a2022-3-phase-200-vac-2-2-kw-variable-frequency-drive-sysdrive-3g3jz-series","title":"Omron 3G3JZ-A2022 3-Phase 200 VAC 2.2 kW Variable Frequency Drive SYSDRIVE 3G3JZ Series","description":"\u003cp\u003eConfigured for frequency modulation and continuous speed regulation of standard induction motors, the \u003cstrong\u003eOmron 3G3JZ-A2022\u003c\/strong\u003e (\u003cstrong\u003e3G3JZ\u003c\/strong\u003e VFD Inverter) provides direct physical execution of primary AC output drives within SYSDRIVE 3G3JZ platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Code\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: SYSDRIVE compact inverter series architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting panel enclosure rated for IP20 protection degree.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: 3-phase 200 VAC voltage class (200 V to 240 V input rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e022\u003c\/strong\u003e: Maximum applicable motor output capacity rated at 2.2 kW.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm x 150 mm x 175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 200 VAC to 240 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Capacity\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e10.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eForced air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network \u0026amp; Bus Busbar Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3G3JZ architecture features onboard communication options and backplane interface logic engineered to reduce drive command response time. Internal bus routing optimizes firmware flash compatibility and dynamic register synchronization across RS-485 Modbus networks, providing reliable real-time speed references and status flag monitoring.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A2022 VFD Inverter unit\u003c\/li\u003e\n\u003cli\u003e1 x Installation manual and wiring guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Electrical Installation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Layout\u003c\/p\u003e\n\u003cp\u003eEnsure vertical orientation on a flat structural panel to support natural heat dissipation via internal cooling fins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearances\u003c\/p\u003e\n\u003cp\u003eMaintain minimum 100 mm top and bottom space, with 50 mm lateral spacing from adjacent industrial devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding \u0026amp; Grounding\u003c\/p\u003e\n\u003cp\u003eBond motor power cables using braided copper shielding to dedicated frame ground terminal to prevent high-frequency noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input phase requirement for the 3G3JZ-A2022?\u003c\/p\u003e\n\u003cp\u003eThis unit requires a 3-phase supply of 200 VAC to 240 VAC at 50\/60 Hz. Operation on single-phase line power causes phase loss faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 3G3JZ-A2022 support direct keypad parameter editing?\u003c\/p\u003e\n\u003cp\u003eYes, the integrated digital operator console allows direct parameter modification and monitoring of output frequency, motor current, and fault codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control method is implemented in this inverter model?\u003c\/p\u003e\n\u003cp\u003eThe drive operates using V\/Hz control with configurable torque boost parameters to optimize low-speed motor operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal protection mechanisms are built into the unit?\u003c\/p\u003e\n\u003cp\u003eOverload detection algorithms monitor motor thermal current metrics alongside physical thermal sensors embedded on the internal heat sink assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the IP enclosure rating for this drive housing?\u003c\/p\u003e\n\u003cp\u003eThe standard unit carries an IP20 protection index for direct installation inside IP54 or higher control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is remote serial communication established?\u003c\/p\u003e\n\u003cp\u003eAn integrated RS-485 port supports Modbus RTU protocol for remote frequency reference writes and diagnostic status reads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan external braking resistors be connected directly?\u003c\/p\u003e\n\u003cp\u003eBraking resistor integration requires verifying internal chopper circuit specifications per manual wiring terminals B1 and B2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the permissible storage temperature range?\u003c\/p\u003e\n\u003cp\u003eStorage ambient conditions must stay within -20 deg C to +60 deg C without condensation or corrosive atmospheric presence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306665918637,"sku":"3G3JZ-A2022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a2022_1.jpg?v=1787719465"},{"product_id":"omron-3g3mx2-a4110-zv1-multi-function-compact-inverter-mx2-series","title":"Omron 3G3MX2-A4110-ZV1 Multi-Function Compact Inverter MX2 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4110-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter, operates as a dedicated hardware component for 3-phase 400 V AC motor velocity and torque modulation within EtherNet\/IP and Modbus network architectures.\u003c\/p\u003e\n\u003ch3\u003eSystem Model Structure \u0026amp; Suffix Code\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter chassis architecture for the MX2 Series drive family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply voltage class (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e110\u003c\/strong\u003e: Maximum applicable motor capacity of 11 kW under continuous Heavy Duty (CT) rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Application-tailored microcode firmware option and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Operating Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4110-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.0 cm x 18.0 cm x 17.0 cm (Shipping Weight: 7.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11 kW rated output motor capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum panel-mounting enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Execution Architecture\u003c\/h3\u003e\n\u003cp\u003eThe inverter internal controller processes real-time drive profiles over Profinet and EtherNet\/IP deterministic networks. Internal hardware utilizes backplane bus communication velocity licences to maintain fixed loop scan intervals without packet transmission jitter. Flexible I\/O density scaling manages high-frequency digital inputs up to 32 kHz, while firmware flash compatibility guarantees seamless configuration file loading from host PLC programming tools.\u003c\/p\u003e\n\u003ch3\u003eOrder Deliverables \u0026amp; Package Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4110-ZV1 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Wiring Protection Shield\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting Rules \u0026amp; Field Cabling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBackplate Mounting Distance\u003c\/p\u003e\n\u003cp\u003eFix the unit vertically to a flat metal enclosure plate, providing at least 100 mm top and bottom space for forced-air heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl Cable Separation\u003c\/p\u003e\n\u003cp\u003eRoute 400 V AC power cables and 24 VDC I\/O signal lines in separate raceways spaced at least 100 mm apart to suppress cross-talk noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth Ground Connection\u003c\/p\u003e\n\u003cp\u003eRun a single low-impedance copper earth cable from the protective ground screw to the main panel earth busbar. Do not loop ground conductors across adjacent units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan main AC power supply wires be connected while input power is active?\u003c\/p\u003e\n\u003cp\u003eNo. Input voltage must be isolated and internal DC bus capacitors measured below 50 VDC using a multimeter prior to handling power terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat activation latency applies to the internal dual safety input channels?\u003c\/p\u003e\n\u003cp\u003eDual safety input channels execute hardware gate suppression within 10 milliseconds, terminating output torque per ISO 13849-1 Cat 3 PLd specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the RS485 communication transceiver isolate serial network lines?\u003c\/p\u003e\n\u003cp\u003eThe onboard RS485 serial port features galvanic isolation to prevent differential ground potential offsets and high-voltage common-mode line noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the inverter rated to drive high-speed motor spindles above standard mains frequency?\u003c\/p\u003e\n\u003cp\u003eYes. Adjustable parameter profiles permit output frequency control up to 1000 Hz, provided motor winding insulation and bearings accommodate the speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen is an external dynamic braking resistor required for motor decelerations?\u003c\/p\u003e\n\u003cp\u003eAn external braking resistor must be connected across DC bus terminals when high-inertia load braking causes regenerative voltage to exceed internal thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current derating factor applies to operations in high ambient temperatures?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be derated by 2.5% per deg C for ambient operating environments continuously exceeding 40 deg C up to 50 deg C max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal configuration parameters preserved across main power loss cycles?\u003c\/p\u003e\n\u003cp\u003eYes. Drive setup parameters, internal pulse sequences, and fault logs are stored permanently in internal non-volatile EEPROM memory without battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding method prevents signal drift on analog 0-10 V control lines?\u003c\/p\u003e\n\u003cp\u003eConnect the braided shield of control cables to the drive ground terminal at the inverter end only to avoid loop currents between remote signal grounds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306668310701,"sku":"3G3MX2-A4110-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4110-zv1_2.jpg?v=1787722998"},{"product_id":"r88m-1m75030t-bs2-omron-1s-servo-motor-1s-series","title":"R88M-1M75030T-BS2 Omron 1S Servo Motor 1S Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron R88M-1M75030T-BS2\u003c\/strong\u003e serves as the primary \u003cstrong\u003eR88M-1M75030T\u003c\/strong\u003e 1S Servo Motor utilized to execute direct precise positioning and torque generation across Sysmac automation platform networks. Driven by a 230 VAC input supply, it delivers a rated capacity of 750 W at 3000 r\/min rated speed, outputting 2.39 Nm rated torque. The unit integrates a 23-bit absolute encoder for real-time shaft feedback and an electromechanical holding brake on a straight shaft with keyway.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Identifier Analysis\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR88M\u003c\/strong\u003e: Omron AC servo motor family designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1M\u003c\/strong\u003e: 1S Series motor structure profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e750\u003c\/strong\u003e: 750 W power rating configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30\u003c\/strong\u003e: Rated rotational speed of 3000 r\/min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT\u003c\/strong\u003e: 230 VAC operating voltage level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Integrated holding brake assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS2\u003c\/strong\u003e: Straight shaft with key and center tap configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eR88M-1M75030T-BS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e30 x 20 x 18 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e750 W (Rated capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Speed\u003c\/td\u003e\n\u003ctd\u003e3000 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Torque\u003c\/td\u003e\n\u003ctd\u003e2.39 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncoder Type\u003c\/td\u003e\n\u003ctd\u003e23-bit absolute encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shaft\u003c\/td\u003e\n\u003ctd\u003eStraight shaft with key and tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake Mechanism\u003c\/td\u003e\n\u003ctd\u003eHolding brake included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange Size\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMotion Bus Dynamics \u0026amp; Interface Architecture\u003c\/h3\u003e\n\u003cp\u003eInterfaced with 1S Servo Drives linked via EtherNet\/IP deterministic networks or EtherCAT motion topologies, the motor processes micro-degree feedback vectors from its 23-bit absolute encoder. High backplane bus communication velocity and rapid cycle times guarantee synchronized multi-axis interpolated motion. Dynamic loop response ensures tight matching with I\/O density scaling and maintaining firmware flash compatibility during controller axis mapping routines.\u003c\/p\u003e\n\u003ch3\u003ePackage \u0026amp; Supply Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron R88M-1M75030T-BS2 Servo Motor\u003c\/li\u003e\n\u003cli\u003e1 x Technical Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting \u0026amp; Connection Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlange Alignment\u003c\/strong\u003e: Bolt the 80 mm flange firmly to a rigid metallic machine bed to maximize thermal dissipation and prevent structural vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft Coupling\u003c\/strong\u003e: Connect the straight keyway shaft to driven machinery using flexible couplings designed for high dynamic torque. Avoid axial impact during key fitting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder Connection\u003c\/strong\u003e: Connect the dedicated encoder cable to the matching 1S drive port; shield braid must maintain 360-degree grounding at the connector shell.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrake Circuit Wiring\u003c\/strong\u003e: Supply 24 VDC control power to the holding brake through an external relay linked to the drive interlock circuit. Do not use the brake for dynamic stopping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Setup\u003c\/strong\u003e: Connect the motor protective earth (PE) terminal directly to the main system ground bus via low-impedance copper wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Knowledge Base\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 23-bit absolute encoder handle position retention during system power loss?\u003c\/p\u003e\n\u003cp\u003eThe high-resolution encoder retains multi-turn location values internally, eliminating homing procedures upon 230 VAC bus re-energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the mechanical holding brake rated for emergency dynamic braking?\u003c\/p\u003e\n\u003cp\u003eNo. The holding brake is specified strictly to lock the motor shaft at standstill and prevent vertical axis fallback during power removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions prevent high-frequency noise from interfering with encoder signals?\u003c\/p\u003e\n\u003cp\u003eRun power lines and encoder cables in separate metallic raceways, keeping low-voltage feedback lines isolated from high-voltage AC inverter outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes shaft radial loading affect encoder longevity?\u003c\/p\u003e\n\u003cp\u003eExcessive side loads cause bearing wear and optical disk misalignment; ensure mechanical loads stay within motor radial and axial limit specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are brake engagement timing delays managed by the motion drive?\u003c\/p\u003e\n\u003cp\u003eThe servo drive controls brake timing sequences automatically to apply holding torque before disabling motor current, preventing vertical drop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal protection measures should be applied to the motor housing?\u003c\/p\u003e\n\u003cp\u003eEnsure natural airflow around the 80 mm flange housing and maintain thermal contact with a metallic mounting plate for heat transfer within the 0 to 40 deg C operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maintenance is required for the 23-bit absolute encoder optical assembly?\u003c\/p\u003e\n\u003cp\u003eThe solid-state encoder uses sealed internal optical sensors that require zero routine mechanical adjustment or internal cleaning over operational life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the keyway shaft design allow direct pulley or gear mounting?\u003c\/p\u003e\n\u003cp\u003eYes. The straight shaft with keyway and center tap supports direct press-fit pulley or coupling installation using locking bolts in the threaded tap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306673258669,"sku":"R88M-1M75030T-BS2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/R88M-1M75030T-BS2_1.jpg?v=1790226718"},{"product_id":"3g3jz-a4022-omron-intelligent-inverter-sysdrive-3g3jz-series","title":"3G3JZ-A4022 Omron Intelligent Inverter SYSDRIVE 3G3JZ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3JZ-A4022\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3JZ\u003c\/strong\u003e Intelligent Easy-to-use Inverter, operates as a dedicated hardware component for 3-phase 400 V AC motor velocity and output frequency modulation within SYSDRIVE automation control networks.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Nomenclature Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Base model platform code for SYSDRIVE 3G3JZ compact intelligent inverter architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enclosure design type indicating panel-mounting configuration (IP20 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: Operating input power supply rating designated as 3-phase AC 400 V class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e022\u003c\/strong\u003e: Maximum applicable motor power output rating defined as 2.2 kW.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Performance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 cm x 12.8 cm x 15.0 cm (Shipping Weight: 3.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.2 kW rated motor capacity output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting IP20 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe inverter internal controller supports deterministic network synchronization via Modbus RTU protocol modules and EtherNet\/IP bus interfaces. High-speed processor logic scales digital I\/O density to evaluate external run\/stop triggers and multi-step frequency references without signal distortion. Firmware flash compatibility ensures unified parameter exchange and error code reporting when integrated into master PLC backplane communication networks.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4022 Drive Inverter Module\u003c\/li\u003e\n\u003cli\u003e1 x Power Supply Terminal Cover Guard\u003c\/li\u003e\n\u003cli\u003e1 x Quick Reference Technical Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePanel Layout \u0026amp; Thermal Distance\u003c\/p\u003e\n\u003cp\u003ePosition the drive vertically on a flat metallic enclosure panel, providing a minimum clearance of 100 mm at the top and bottom to enable unrestricted heat sink airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing \u0026amp; Noise Mitigation\u003c\/p\u003e\n\u003cp\u003eSeparate primary 400 V AC power leads from 24 VDC control lines and analog signal cables by at least 100 mm to prevent inductive signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Ground Termination\u003c\/p\u003e\n\u003cp\u003eWire a single protective earth conductor from the PE ground terminal directly to the panel earth busbar. Avoid daisy-chaining ground connections across multiple drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan main input terminals be wired or disconnected while the inverter is connected to AC mains?\u003c\/p\u003e\n\u003cp\u003eNo. Main line power must be fully isolated and internal DC bus capacitors allowed to discharge below 50 VDC before performing any wiring operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital input filtering applies to control signal terminals during transient noise exposure?\u003c\/p\u003e\n\u003cp\u003eInternal digital inputs utilize programmable hardware logic delay filters to eliminate noise pulses below 5 milliseconds, preventing erroneous fault tripping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the Modbus serial communication interface withstand high-voltage bus surges?\u003c\/p\u003e\n\u003cp\u003eThe integrated RS485 communication transceiver features hardware galvanic isolation to suppress common-mode voltage noise and ground potential differences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive operate high-frequency motors above standard mains supply frequencies?\u003c\/p\u003e\n\u003cp\u003eYes. Configurable internal registers allow output frequency scaling up to 400 Hz, subject to motor mechanical bearing and insulation voltage limitations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external dynamic braking resistor mandatory for standard stop routines?\u003c\/p\u003e\n\u003cp\u003eNo. Internal braking choppers manage standard decelerations; external braking resistors are required only when high-inertia regeneration exceeds thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should continuous output power be derated when operating above normal ambient temperatures?\u003c\/p\u003e\n\u003cp\u003eThe rated output current must be derated by 2.5% per deg C for operating environments continuously exceeding 40 deg C up to a maximum limit of 50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal drive parameters preserved across total primary power loss cycles?\u003c\/p\u003e\n\u003cp\u003eYes. Operating parameters, customizable V\/f curves, and fault logs are written directly to internal non-volatile EEPROM memory without battery dependency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ground shield configuration prevents analog reference voltage distortion on control loops?\u003c\/p\u003e\n\u003cp\u003eTerminate the cable braid shield to the drive earth terminal on the inverter side only to avoid ground loop current flows across remote control points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306673979565,"sku":"3G3JZ-A4022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4022_2.jpg?v=1787720160"},{"product_id":"omron-3g3mx2-a4004-zv1-mx2-series-multi-function-compact-inverter","title":"Omron 3G3MX2-A4004-ZV1 MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4004-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter, operates as a dedicated hardware component for 3-phase 400 V AC motor velocity and torque modulation within industrial drive network architectures.\u003c\/p\u003e\n\u003ch3\u003eSystem Model Matrix \u0026amp; Suffix Decoding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter platform designation for the MX2 product line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure framework (rated IP10 minimum) or closed wall-mounting structural design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply rating (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e004\u003c\/strong\u003e: Maximum applicable motor capacity of 0.4 kW under continuous heavy-duty (CT) loading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Application-specific firmware integration build and customized functional specification variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4004-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 cm x 6.8 cm x 14.55 cm (Shipping Weight: 4.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.4 kW rated motor output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Class\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum panel-mounting enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Industrial Network Interoperability\u003c\/h3\u003e\n\u003cp\u003eThe inverter integrates high-speed bus connectivity supporting EtherNet\/IP deterministic networks and Modbus RTU protocols. Dynamic firmware flash compatibility ensures zero-latency parameter synchronization with host PLC processors, while I\/O density scaling enables direct impulse input positioning up to 32 kHz without auxiliary option boards.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4004-ZV1 Inverter Unit\u003c\/li\u003e\n\u003cli\u003e1 x Protective Wiring Terminal Cover Plate\u003c\/li\u003e\n\u003cli\u003e1 x System Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Enclosure Mounting\u003c\/p\u003e\n\u003cp\u003eInstall the drive vertically on a flat ground-bonded metallic surface to ensure optimal thermal dissipation and low-impedance ground return paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal \u0026amp; Power Cable Separation\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum clear spacing of 100 mm between 400 V line conductors and low-voltage analog or digital control cables to prevent inductive interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Ground Bonding\u003c\/p\u003e\n\u003cp\u003eRun a direct protective conductor from the PE terminal to the primary panel earthing busbar. Do not connect protective earth conductors in a daisy-chain configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Hardware Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted on the main AC power input terminals during operation?\u003c\/p\u003e\n\u003cp\u003eNo. Main AC power must be isolated and DC bus voltage verified below 50 VDC using a voltmeter before servicing terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal propagation delay occurs when activating the hardware safety inputs?\u003c\/p\u003e\n\u003cp\u003eThe integrated dual safety input terminals interrupt drive output power within 10 milliseconds, adhering to ISO 13849-1 Cat 3 PLd standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit maintain serial bus integrity during high-voltage line transients?\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation on the serial communication port isolates internal control logic from common-mode voltage spikes and ground potential differences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the drive operate high-frequency spindle motors exceeding standard mains frequency limits?\u003c\/p\u003e\n\u003cp\u003eYes. Adjustable parameter profiles permit output frequency operation up to 1000 Hz, subject to thermal capacity and motor winding insulation ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external dynamic braking resistor required for low-inertia stop profiles?\u003c\/p\u003e\n\u003cp\u003eNo. Internal braking transistors absorb low-inertia energy; external braking resistors are required only when regenerative energy exceeds internal thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current derating factor applies when ambient temperatures exceed normal limits?\u003c\/p\u003e\n\u003cp\u003eContinuous current capacity must be reduced linearly by 2.5% per deg C for ambient operating environments between 40 deg C and 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the parameter memory structure require an auxiliary battery for data persistence?\u003c\/p\u003e\n\u003cp\u003eNo. System logic configurations, customer parameters, and operating fault histories are stored permanently in non-volatile internal EEPROM memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should control cable shielding be terminated to reduce analog signal corruption?\u003c\/p\u003e\n\u003cp\u003eGround the cable shield braid at the inverter side earth point only. Leaving the remote end ungrounded prevents loop currents from distorting signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306677158061,"sku":"3G3MX2-A4004-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4004-zv1_1.jpg?v=1787721696"}],"url":"https:\/\/www.maxwellplc.com\/ga\/collections\/omron-drives-servo-motion-control.oembed?page=2","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}