{"product_id":"ge-fanuc-ic695lre001-serial-bus-transmitter-module-rx3i","title":"GE Fanuc IC695LRE001 Serial Bus Transmitter Module RX3i","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695LRE001\u003c\/strong\u003e is a Serial Bus Transmitter Module designed for the PACSystems RX3i programmable logic controller platform. It provides communication between an RX3i Universal Backplane and serial expansion or remote backplanes, converting signal levels for the expansion bus interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695LRE001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSerial Bus Transmitter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog\u003c\/td\u003e\n\u003ctd\u003eIC695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.20-0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 130 × 107 × 32 mm (L × W × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e132 mA at 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.3 VDC Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffective Data Rate\u003c\/td\u003e\n\u003ctd\u003e500 kBytes\/s when remote backplanes are included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length - Expansion\u003c\/td\u003e\n\u003ctd\u003e15 m (50 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length - Remote\u003c\/td\u003e\n\u003ctd\u003e213 m (700 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eNon-isolated differential communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Backplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eIC694 and IC693 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eEXP OK, EXPANSION ACTIVE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDedicated expansion connector on right end of Universal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Fasteners\u003c\/td\u003e\n\u003ctd\u003eTwo captive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Maximum Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm (4.4 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eWeight and dimensions are approximate supplier-reported values, not manufacturer-confirmed mechanical specifications. Verify the physical unit before finalizing shipping information.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695LRE001 operates as an expansion interface within the GE Fanuc PACSystems RX3i architecture. It connects the main Universal Backplane to compatible serial expansion and remote backplanes.\u003c\/p\u003e\n\u003cp\u003eThe module performs signal-level conversion between the RX3i Universal Backplane and downstream expansion hardware. This allows additional I\/O backplanes to communicate with the main controller system.\u003c\/p\u003e\n\u003cp\u003eUnlike standard RX3i I\/O modules, the IC695LRE001 installs in the dedicated expansion connector at the right end of the Universal Backplane. It uses two captive screws for mechanical attachment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBackplane Communication and Expansion Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695LRE001 supports serial expansion through compatible IC694 and IC693 backplane configurations.\u003c\/p\u003e\n\u003cp\u003eIts main engineering functions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-Level Conversion:\u003c\/strong\u003e Converts Universal Backplane signals into the levels required by serial expansion backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Rack Communication:\u003c\/strong\u003e Provides the communication interface for downstream remote backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e Supports an RX3i system configuration with up to seven serial expansion and remote backplanes in total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Signaling:\u003c\/strong\u003e Uses non-isolated differential communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Monitoring:\u003c\/strong\u003e Provides two front-panel LEDs for monitoring power and expansion bus activity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eExpansion Cable Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe expansion bus uses dedicated cables to connect the transmitter module with downstream backplanes.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Model\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CBL300\u003c\/td\u003e\n\u003ctd\u003eWye Expansion Cable, 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CBL301\u003c\/td\u003e\n\u003ctd\u003eWye Expansion Cable, 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CBL302\u003c\/td\u003e\n\u003ctd\u003eTwo-Connector Expansion Cable, 15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CBL312\u003c\/td\u003e\n\u003ctd\u003eWye Expansion Cable, 0.15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CBL313\u003c\/td\u003e\n\u003ctd\u003eWye Expansion Cable, 8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693ACC307\u003c\/td\u003e\n\u003ctd\u003eExpansion Bus Termination Resistor Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eMaximum total cable lengths are 15 m for expansion backplanes and 213 m for remote backplanes. The IC693CBL302 includes a built-in terminating resistor.\u003c\/p\u003e\n\u003cp\u003eCable selection, routing, and termination must follow the applicable PACSystems RX3i system configuration requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indicators and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695LRE001 incorporates two green LEDs to indicate its operating condition and expansion communication status.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXP OK:\u003c\/strong\u003e Illuminates when 5.0 VDC backplane power is applied to the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXPANSION ACTIVE:\u003c\/strong\u003e Illuminates when the expansion module communicates with connected expansion backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen EXP OK is off, inspect the backplane power supply and module connection. When EXPANSION ACTIVE is off, check expansion cables, downstream backplane power, and bus termination.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Electrical Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC695LRE001 mounts directly into the dedicated expansion connector on the right-hand side of the RX3i Universal Backplane.\u003c\/p\u003e\n\u003cp\u003eInstallation considerations:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eRemove backplane power before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the transmitter with the dedicated expansion connector.\u003c\/li\u003e\n\u003cli\u003eInsert the module straight into the connector.\u003c\/li\u003e\n\u003cli\u003eSecure it using the two captive mounting screws.\u003c\/li\u003e\n\u003cli\u003eObserve the manufacturer's maximum recommended screw torque of 4.4 in-lb.\u003c\/li\u003e\n\u003cli\u003eConnect the appropriate expansion cable and verify the bus termination configuration.\u003c\/li\u003e\n\u003cli\u003eCheck both front-panel LEDs after restoring system power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant installation restrictions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe module does not support hot insertion or removal.\u003c\/li\u003e\n\u003cli\u003eExpansion cables must not be connected or disconnected while the expansion rack is powered.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer's grounding, shielding, and cable installation requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm backplane compatibility before integrating the module into an existing RX3i system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What is the main function of the IC695LRE001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides serial expansion bus communication between a PACSystems RX3i Universal Backplane and compatible expansion or remote backplanes.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Which PLC platform supports this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC695LRE001 is designed for the GE Fanuc PACSystems RX3i programmable logic controller platform.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Where is the IC695LRE001 installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It installs in the dedicated expansion connector located at the right end of the RX3i Universal Backplane.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What is the module's current consumption?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It draws 132 mA from the 5.0 VDC backplane supply and 0 mA from the 3.3 VDC supply.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What is the maximum expansion cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The maximum total cable length is 15 m for expansion backplanes and 213 m for remote backplanes.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Does the IC695LRE001 support hot swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Backplane power must be removed before installing or removing the Serial Bus Transmitter Module.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What do the front-panel LEDs indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: EXP OK indicates backplane 5 VDC power, while EXPANSION ACTIVE indicates communication with expansion backplanes.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Which expansion cables can be used with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Documented cable options include IC693CBL300, IC693CBL301, IC693CBL302, IC693CBL312, and IC693CBL313.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":68366053048493,"sku":"IC695LRE001","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ic695lre001__3.jpg?v=1795080723","url":"https:\/\/www.maxwellplc.com\/es\/products\/ge-fanuc-ic695lre001-serial-bus-transmitter-module-rx3i","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}