{"product_id":"3500-33-01-r0-bently-nevada-16-channel-relay-module-3500-system","title":"3500\/33-01-R0 Bently Nevada 16-Channel Relay Module 3500 System","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-01-R0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/33\u003c\/strong\u003e 16-Channel Relay Module, operates as a dedicated hardware component for relay output execution and voting logic control within 3500 Machinery Condition Monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33\u003c\/strong\u003e: Base model designation for the 16-channel relay output module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Output module option specifying the 16-channel standard relay output configuration with silver contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR0\u003c\/strong\u003e: Factory revision and mounting identifier associated with standard system builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/33-01-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eMain Module: 0.7 kg (1.6 lb); I\/O Module: 0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eMain: 241 mm x 24.4 mm x 242 mm; I\/O: 241 mm x 24.4 mm x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C (-4 deg F to +149 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole Double-throw (SPDT), epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e125 Vdc \/ 250 Vac (Resistive Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Protection \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Drive Logic Execution\u003c\/strong\u003e: Processes individual measured variables, alert statuses, danger statuses, and Not-OK conditions through programmable AND and OR Boolean voting logic configured via the 3500 Rack Configuration Software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling \u0026amp; Cross-Talk Suppression\u003c\/strong\u003e: Interfaces directly with monitor modules tracking rotor dynamics, ensuring that overall vibration amplitudes, gap voltage thresholds, and filtered phase parameters trigger corresponding relay states without signal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe and Operation Modes\u003c\/strong\u003e: Features switch-selectable options for Normally De-energized (ND) or Normally Energized (NE) operation across four groups of four channels to maintain strict trip logic integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3500\/33 Main Relay Module (Part Number 162096-01)\u003c\/li\u003e\n\u003cli\u003e1 x 16-Channel Relay I\/O Module with Terminal Headers\u003c\/li\u003e\n\u003cli\u003e1 x 16-Channel Relay Module User Guide (Document 162291)\u003c\/li\u003e\n\u003cli\u003e1 x Grounding Wrist Strap (Single Use)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Allocation\u003c\/strong\u003e: Install the main module in any available front slot to the right of the Transient Data Interface (TDI) module, placing the associated I\/O module in the corresponding rear slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring\u003c\/strong\u003e: Secure field wiring to the 16-position green connector headers, ensuring that applied voltages do not exceed specified limits to prevent insulation breakdown or high-voltage shock hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Verification\u003c\/strong\u003e: Verify that the rack runs 3500 Rack Configuration Software version 3.3 or later, Data Acquisition Software version 2.40 or later, and Data Display Software version 1.40 or later prior to system startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum switched load requirement for the standard relay contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard silver contacts require a minimum switched load of 100 mA at 5 Vdc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 3500\/33 module be placed in any rack slot?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module can occupy any available monitor or relay slot located to the right of the TDI module, but cannot use slots reserved exclusively for power supplies and the TDI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are relay operation modes selected on the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRelay operation is configured by four groups of four channels using hardware selection switches for Normally Energized or Normally De-energized operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software version is required to configure the 3500\/33 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration requires 3500 Rack Configuration Software version 3.3 or later.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre the relay contacts epoxy-sealed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe relays feature epoxy-sealed environmental sealing and include factory-installed 250 Vrms arc suppressors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power consumption of the module during normal operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe typical power consumption is 5.8 watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModules within the 3500 rack are designed to be inserted or removed from the rack backplane while rack power is applied, provided hazardous live terminals are isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of relay output configuration does option 01 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOption 01 provides a 16-channel standard relay output using single-pole double-throw (SPDT) contacts with silver material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46892188237997,"sku":"3500\/33-01-R0","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/350020_13_bcb71383-04e5-4a6d-9b3f-7d87891534aa.jpg?v=1784769312","url":"https:\/\/www.maxwellplc.com\/es\/products\/3500-33-01-r0-bently-nevada-16-channel-relay-module-3500-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}