{"product_id":"3500-15-01-01-r0-bently-nevada-power-supply-module-3500-system","title":"3500\/15-01-01-R0 Bently Nevada Power Supply Module 3500 System","description":"\u003cp\u003eConfigured for power conversion and backplane voltage regulation in 3500 Machinery Condition Monitoring platforms, the \u003cstrong\u003eBently Nevada 3500\/15-01-01-R0\u003c\/strong\u003e (\u003cstrong\u003e3500\/15\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/15\u003c\/strong\u003e: Base model designation for the AC and DC power supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Power supply option designating the universal AC voltage input variant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01-R0\u003c\/strong\u003e: Factory revision and mounting identifier associated with standard system builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15-01-01-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C (-4 deg F to +149 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUniversal voltage AC 2.8 A rms maximum full rack current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 Vac rms (Non-hazardous areas), 85 to 250 Vac rms (Hazardous areas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Signal Conditioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling Protection\u003c\/strong\u003e: Provides stable DC rail voltages to monitor modules, ensuring that eddy-current displacement sensors maintain precise scaling and linear output responses across transient operational ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation\u003c\/strong\u003e: Supplies regulated power essential for maintaining -10 VDC target values on proximity probes, preventing signal drift during rotor dynamics analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Suppression\u003c\/strong\u003e: Incorporates internal line noise filtering and galvanic segregation to minimize electrical noise propagation between high-power actuator loops and sensitive vibration monitoring channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3500\/15 Power Supply Main Module\u003c\/li\u003e\n\u003cli\u003e1 x Universal AC Power Input Module (PIM)\u003c\/li\u003e\n\u003cli\u003e1 x Installation and Maintenance User Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Allocation\u003c\/strong\u003e: Install the power supply and associated PIM exclusively into the left-most slots reserved for power supplies within the 3500 instrument rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Configuration\u003c\/strong\u003e: When utilizing dual power supplies, place the primary supply in the lower slot and the backup supply in the upper slot to achieve instantaneous failover without rack disruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal and Grounding Security\u003c\/strong\u003e: Fasten all input line terminations securely to the PIM rear connectors while maintaining low-impedance chassis grounding to prevent ground loops and electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage range does the 3500\/15-01 universal AC supply support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe universal AC supply supports 85 to 264 Vac rms in non-hazardous areas and 85 to 250 Vac rms in hazardous areas, with a frequency range of 47 to 63 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle under-voltage conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn under-voltage condition causes no physical harm to the power supply or the power input module (PIM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during an over-voltage condition on the input line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn over-voltage condition causes the internal fuse on the PIM to open, protecting downstream circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan dual power supplies be operated from different voltage sources?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDual supplies can utilize separate voltage sources, such as combining a 120 Vac primary supply with an uninterruptible 24 Vdc backup source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum full rack current draw for the universal AC power supply option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum full rack current draw is 2.8 A rms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is normal operation of the power supply indicated on the hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA front-panel green Supply OK LED illuminates when the power supply is operating properly and all output voltages are within specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre 3500 power supplies hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower supply modules are designed to be inserted or removed from the rack backplane while rack power is applied, provided safety precautions for live terminals are observed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the universal AC power supply compatible with legacy high-voltage AC units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe universal AC power supply and power input module are not compatible with legacy high-voltage AC or low-voltage AC units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46892223987885,"sku":"3500\/15-01-01-R0","price":1888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/350015-13_6aea40d6-0fef-4b37-a224-7114fa1a6cf1.jpg?v=1784769725","url":"https:\/\/www.maxwellplc.com\/es\/products\/3500-15-01-01-r0-bently-nevada-power-supply-module-3500-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}