{"title":"Yokogawa Rack Chassis","description":"\u003cp\u003e\u003cspan\u003eThe structural integrity of your control system starts with the \u003c\/span\u003e\u003cstrong\u003eYokogawa Rack Chassis\u003c\/strong\u003e\u003cspan\u003e. These base units, often referred to as \"Nests\" or \"Node Units,\" provide the backplane for your I\/O and communication modules. Designed for high-density installations, our selection of \u003c\/span\u003e\u003cstrong\u003eANB10\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eANT10\u003c\/strong\u003e\u003cspan\u003e units supports the Vnet\/IP real-time control network. Each chassis is engineered for optimal thermal management and electromagnetic shielding, ensuring that your modular hardware remains secure and electrically isolated in demanding industrial cabinets.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"yokogawa-afv10d-s2-duplexed-field-control-unit","title":"Yokogawa AFV10D S2 Duplexed Field Control Unit","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa AFV10D S2 is a high-performance Field Control Unit (FCS) designed as the primary control node for the CENTUM VP Distributed Control System (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis duplexed unit provides the computational foundation for regulatory control,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esequence logic execution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand process signal management.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing a redundant hardware architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe AFV10D S2 ensures maximum system availability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for seamless failover between processor modules without interrupting active plant processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eEngineered for the Vnet\/IP high-speed control network,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe AFV10D S2 coordinates communication between I\/O nodes and supervisory stations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically built for mission-critical applications in the oil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epetrochemical,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand power generation industries,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhere hardware reliability and deterministic control timing are essential for operational safety and efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAFV10D S2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eType:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDuplexed Field Control Unit (FCS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessor:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVR5432 (133 MHz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMain Memory:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e32 MB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVnet\/IP (Dual-redundant support)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eI\/O Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFIO (Field Interface Orbus) architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBattery Backup:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 72 hours of data retention; 48-hour minimum recharge cycle\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eForm Factor:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e19-inch rack-mountable (5U height)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e44 kg (Standard configuration)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e48.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm x 22.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm x 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Control Logic:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe duplexed configuration features dual-processor modules operating in parallel with synchronized memory.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis fault-tolerant design prevents system downtime by automatically switching to the standby controller if a fault is detected in the primary unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Processing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a 133 MHz RISC processor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe unit handles high-density control loops and complex computational algorithms with minimal scan-time latency,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring stable process regulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Vnet\/IP Communication:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports the Vnet\/IP protocol,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich provides high-capacity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereal-time data transmission over standard 1-Gbps Ethernet physical layers while maintaining the deterministic performance required for DCS environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAdvanced Data Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA robust battery backup system safeguards volatile memory,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreserving control parameters and sequence states for up to three days during complete power loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eScalable FIO Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eActs as the master controller for various FIO I\/O modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for flexible expansion of analog and digital points across the control network.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCertified for operation in challenging environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe AFV10D S2 is resistant to thermal fluctuations and high humidity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring long-term hardware integrity in diverse industrial control rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45519049687213,"sku":"AFV10D S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa-afv10d-s2-field-control-unit-zwjsgybyhr0.jpg?v=1766985747"},{"product_id":"yokogawa-afv30d-s2-duplexed-field-control-unit-fcs-for-centum-vp","title":"Yokogawa AFV30D-S2 Duplexed Field Control Unit (FCS) for CENTUM VP","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa AFV30D-S2 is a high-availability Duplexed Field Control Unit (FCS) that serves as the central intelligence for the CENTUM VP Distributed Control System (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for mission-critical industrial processes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis unit features a redundant architecture to ensure continuous plant operation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy housing two synchronized processor modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe AFV30D-S2 eliminates single points of failure; if the active controller detects a fault,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe standby unit takes over control instantaneously without interrupting the process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDesigned for 19-inch rack mounting,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis unit efficiently manages I\/O communication,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econtrol logic execution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand data synchronization across the Vnet\/IP network.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is the preferred choice for large-scale facilities such as oil refineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echemical plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand power stations where downtime results in significant operational loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAFV30D-S2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDuplexed Field Control Unit (Redundant)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCENTUM VP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Protocol:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVnet\/IP (1 Gbps High-Speed Control Bus)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessor Configuration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant (Duplexed)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Supply:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant AC or DC inputs supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch Rack Mount\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 to 50°C (Standard Industrial)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Certifications:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUL\/CSA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCE,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand KC Marking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e82 mm x 262 mm x 210 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e38 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBumpless Redundancy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe duplexed configuration ensures that the standby processor remains in perfect synchronization with the active unit.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a hardware transition,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe switchover is \"bumpless,\u003c\/span\u003e\u003cspan class=\"\"\u003e\" meaning there is no loss of data or control continuity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVnet\/IP Connectivity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in support for the Vnet\/IP protocol allows for deterministic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehigh-speed communication between the control unit and Human Interface Stations (HIS),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring real-time process visibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry is protected with high-quality conformal coating,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking the hardware resistant to corrosive gases (ISA G3 compliant environments) and increasing the lifespan of the equipment in harsh chemical climates.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFlexible Expansion:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe AFV30D-S2 manages local and remote I\/O nodes via the ESB bus or Optical ESB bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for extensive plant-wide distribution of I\/O points while maintaining centralized logic execution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAdvanced Calculation Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for complex process calculations and sequence control,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the computational power necessary for modern Industry 4.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 automation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGlobal Compliance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully certified to international electrical and safety standards (CE,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUL,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCSA),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring the unit can be deployed in regulated markets worldwide with complete regulatory adherence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45519059550381,"sku":"AFV30D S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa-afv30d-s2-duplexed-field-control-unit-ouqnrftiaui.jpg?v=1766985913"},{"product_id":"yokogawa-afv10d-duplexed-field-control-unit-vnet-ip-for-centum-vp","title":"Yokogawa AFV10D Duplexed Field Control Unit (Vnet\/IP) for CENTUM VP","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Yokogawa AFV10D is a high-availability Duplexed Field Control Unit (FCU) designed as the core processing engine for the CENTUM VP Distributed Control System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis unit is specifically engineered to execute complex regulatory control,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esequence control,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand data management tasks with high-speed reliability.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing a dual-redundant processor configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe AFV10D ensures that control is maintained without interruption; in the event of a hardware fault on the primary processor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe standby unit takes over control bumplessly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eCommunicating via the high-speed Vnet\/IP control network,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe AFV10D serves as the central hub for field signals processed through I\/O modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts architecture is optimized for large-scale industrial plants requiring maximum uptime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a stable platform for mission-critical logic execution and seamless integration with Human Interface Stations (HIS).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAFV10D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eControl Unit Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDuplexed (Redundant) Field Control Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eControl Network:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eVnet\/IP (100 Mbps Full Duplex)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessor Configuration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRedundant CPU modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMemory Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-capacity RAM for extensive logic and tag storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e48 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStandard Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e482 mm x 220 mm x 50 mm (19-inch rack mountable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRack-mount or Cabinet installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Tolerance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for continuous operation in high-temperature and humid industrial zones\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eCore Functionality and System Benefits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFault-Tolerant Redundancy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe duplexed design eliminates single points of failure within the controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it essential for processes where shutdown is not an option.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVnet\/IP Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes standard Ethernet-based technology for the control bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for rapid data exchange and easier synchronization across the DCS network.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Speed Logic Execution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a powerful microprocessor capable of handling intensive computational loads,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring precise control over fast-acting process variables.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMaintenance and Scalability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports online hardware replacement and expansion.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe unit is designed for long-term lifecycle support within the CENTUM VP ecosystem,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edespite its legacy status in newer installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Grade Build:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConstructed to withstand electrical noise and vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emeeting international standards for safety and electromagnetic compatibility (EMC).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45519067021485,"sku":"AFV10D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/yokogawa-afv10d-duplexed-field-control-unit-fdnf1mcr5s2.jpg?v=1766986074"},{"product_id":"yokogawa-esb-bus-node-unit-anb10d-425-cu2t-ndel-dual-redundant-interface","title":"Yokogawa ESB Bus Node Unit ANB10D-425\/CU2T\/NDEL Dual-Redundant Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ANB10D-425\/CU2T\/NDEL is a high-availability node unit specifically designed for the CENTUM VP and CS 3000 Distributed Control Systems (DCS). This hardware serves as a critical junction within the Extended Serial Backplane (ESB) bus architecture, allowing for the seamless expansion of I\/O modules across the control network. Engineered for maximum reliability, this specific model features a dual-redundant power supply configuration to ensure the system remains operational even in the event of a single power source failure. The inclusion of the \/CU2T terminator and the \/NDEL software license allows for high-speed, long-distance communication with zero signal reflection, making it a cornerstone for large-scale industrial automation plants that require uncompromising data integrity.\u003c\/p\u003e\n\u003ch3\u003eEngineering Specifications and Hardware Layout\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-425\/CU2T\/NDEL is built to industrial standards to support mission-critical infrastructure. The technical parameters include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Dual-Redundant Power Supplies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e220 V to 240 V AC (50\/60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\/NDEL Software License included for node expansion capabilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\/CU2T Connector Units with built-in terminators (Part No. S9564FA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic type designed for non-explosion hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApproximate Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e48.3 cm x 13.2 cm x 25.0 cm (Standard 19-inch rack mounting)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBackplane or Rack Mount compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Use Cases and Industrial Environments\u003c\/h3\u003e\n\u003ch3\u003eRefinery and Petrochemical Control\u003c\/h3\u003e\n\u003cp\u003eIn large-scale processing facilities, the ANB10D facilitates the connection between the main Field Control Station (FCS) and remote I\/O racks. Its dual-redundancy is vital for maintaining continuous monitoring of temperature and pressure loops where a communication blackout could lead to costly safety shutdowns.\u003c\/p\u003e\n\u003ch3\u003ePower Generation and Grid Management\u003c\/h3\u003e\n\u003cp\u003eUtilized within thermal and hydroelectric power plants, this ESB Bus Node manages high-density data traffic from turbine sensors. The built-in \/CU2T terminators ensure that high-frequency signals are transmitted over the bus without interference, providing the clean data needed for millisecond-perfect governor control.\u003c\/p\u003e\n\u003ch3\u003eWater and Wastewater Treatment\u003c\/h3\u003e\n\u003cp\u003eFor geographically dispersed infrastructure, the \/NDEL license allows engineers to expand the number of nodes in the system easily. This makes it an ideal solution for water treatment facilities that need to add more filtration or pumping I\/O modules as the plant capacity grows over time.\u003c\/p\u003e\n\u003ch3\u003ePharmaceutical Manufacturing\u003c\/h3\u003e\n\u003cp\u003eIn environments where batch integrity is paramount, the ANB10D-425 provides a stable communication backbone. The redundant AC power supply ensures that the automation sequence is never interrupted by electrical surges or local power faults, protecting expensive chemical batches from spoilage.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the \/CU2T option code on this node?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/CU2T designates that the unit comes equipped with Connector Units that include built-in Terminators. These are essential for the physical ends of an ESB bus segment to prevent signal reflections that could cause data corruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this unit be used in systems running on 110V AC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the \"2\" in the suffix code (425) specifies that this unit is hardware-coded for 220 - 240 V AC. For 110V systems, a different suffix code (e.g., -415) would be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \/NDEL software license a physical component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/NDEL represents a software license entitlement for Node Expansion. While it is associated with the hardware order, it grants the system the logical permission to recognize and communicate with additional nodes within the CENTUM VP environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the dual-redundancy in the power supply work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit contains two independent power modules. If one fails or loses its input source, the other immediately carries the full electrical load without any interruption to the ESB bus communication or the attached I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of I\/O modules this node can support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Typically, an ANB10D node unit can house up to 8 I\/O modules. However, the total system capacity depends on the specific Field Control Station (FCS) model you are using in your Yokogawa DCS setup.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45875016990893,"sku":"ANB10D-425\/CU2T\/NDEL","price":1250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ANB10D-425S22_e620b5e5-0009-42fe-b6c3-32b8665ee90e.jpg?v=1774950143"},{"product_id":"yokogawa-anb10d-420-cu2n-ndel-esb-bus-node-unit-interface","title":"Yokogawa ANB10D-420\/CU2N\/NDEL ESB Bus Node Unit Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-420\/CU2N\/NDEL functions as a high-reliability expansion node for Yokogawa’s proprietary ESB (Extended Serial Backplane) bus system. This unit is specifically engineered to provide a robust physical and electrical interface for I\/O modules, facilitating seamless communication between field instruments and the central control station. Designed for mission-critical Distributed Control System (DCS) architectures, this node unit supports dual-redundant power configurations to prevent system-wide outages in the event of a single power supply failure. It serves as a direct successor and replacement for the ANB10D\/CU2N series, offering refined electrical stability and enhanced support for node expansion through integrated software licensing.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters and Mechanical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following technical profile details the physical and electrical constraints of the ANB10D architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-Resistant ESB Bus interface for high-availability networking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant modules supporting 220 - 240 V AC input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 VA (AC) \/ 5.5 A (DC) typical draw.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kg (unpacked).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch rack mounting width; approximately 132.5 mm height (3U).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRack mount (M5 x 4 screws) featuring insulation bushings for electrical isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\/CU2N ESB Bus connector unit pre-installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncluded \/NDEL software license for immediate node expansion capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic type (non-explosion proof) intended for controlled industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking Size\u003c\/strong\u003e: \u003cspan\u003e482 mm Width x 132 mm Height x 300 mm Depth\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Utilization and Deployment\u003c\/h3\u003e\n\u003ch3\u003eDistributed Control System Expansion\u003c\/h3\u003e\n\u003cp\u003eThe primary application of the ANB10D-420 is the expansion of I\/O capacity within a Yokogawa CENTUM VP or CS 3000 environment. By linking this node to the ESB bus, plant engineers can distribute I\/O modules across multiple racks while maintaining the low-latency communication required for real-time process loops.\u003c\/p\u003e\n\u003ch3\u003eFault-Tolerant Power Infrastructure\u003c\/h3\u003e\n\u003cp\u003eIn sectors such as petrochemical refining and power generation, power failure is not an option. The dual-redundant power suffix on this unit allows for two independent power feeds, ensuring that even if one circuit breakers trips, the field data flow remains uninterrupted.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Data Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe \/CU2N connector interface provides the high-fidelity signal path necessary for high-speed data acquisition. This is critical in applications like turbine monitoring or fast-cycle batch processing, where signal integrity directly impacts safety and product quality.\u003c\/p\u003e\n\u003ch3\u003eRemote I\/O Interfacing\u003c\/h3\u003e\n\u003cp\u003eThanks to the rack-mountable design and insulation protection, this unit is frequently deployed in localized control rooms or satellite instrument houses. It allows for the centralization of process data from remote plant areas back to the main control logic solver via the ESB bus.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ANB10D-420\/CU2N\/NDEL be used as a direct replacement for older ANB10D\/CU2N units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, this model is designed as a functional replacement for the standard ANB10D\/CU2N, offering improved reliability and the inclusion of the NDEL expansion license for modern system configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the \/NDEL suffix in this specific package?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/NDEL code signifies that the unit includes the Software License for Node Expansion. This allows the DCS to recognize and integrate the new node into the existing network without requiring separate software procurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit suitable for use in hazardous areas where explosion protection is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the suffix \"0\" in the model code indicates that this is a basic type with no explosion protection. It should only be installed in safe areas or within purged and pressurized enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of mounting hardware is required for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit is designed for standard 19-inch rack mounting. It requires four M5 screws and the included insulation bushings to ensure the unit is properly isolated from the rack frame to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the dual-redundant power supply handle a failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit utilizes an internal load-sharing mechanism. If one power module fails, the second module immediately assumes the full load without any dip in voltage or interruption to the ESB bus communication.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45876164952237,"sku":"ANB10D-420\/CU2N\/NDEL","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ANB10D-410.jpg?v=1775010156"},{"product_id":"afv10d-s41101-yokogawa-duplexed-field-control-unit-vnet-ip-interface","title":"AFV10D-S41101 Yokogawa Duplexed Field Control Unit Vnet\/IP Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa AFV10D-S41101 represents the core processing intelligence of the CENTUM VP control architecture. This Duplexed Field Control Unit (FCU) is specifically engineered to host the LFS1500 control functions, managing complex automation tasks through the high-speed Vnet\/IP communication protocol. Designed for 19-inch rack mounting, the unit provides a robust platform for FIO (Field network I\/O) integration. Its primary purpose is to ensure zero-downtime operations by utilizing a fully redundant internal hardware structure, including dual-redundant power supplies and processors, which allows for seamless failover in the event of a hardware fault.\u003c\/p\u003e\n\u003ch3\u003eHardware Infrastructure \u0026amp; Core Parameters\u003c\/h3\u003e\n\u003cp\u003eThe following specifications detail the electrical and physical profile of the AFV10D-S41101 controller assembly.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Configuration\u003c\/strong\u003e: Fully Duplexed (CPU, Vnet\/IP, and Power Supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e: Vnet\/IP (1 Gbps Ethernet-based)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Functionality\u003c\/strong\u003e: LFS1500 Field Control Station logic integrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 100 V to 120 V AC (Single Phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Tolerance\u003c\/strong\u003e: 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 200 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Standard\u003c\/strong\u003e: 19-inch Rack Mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Thermal Range\u003c\/strong\u003e: 0 to 55 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Unit Mass\u003c\/strong\u003e: 0.9 kg (900g)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e: 203 mm x 146 mm x 51 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Connectivity\u003c\/strong\u003e: Supports direct connection to local and remote FIO nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cp\u003eThis Field Control Unit is the preferred choice for large-scale industrial projects requiring the highest levels of functional safety and availability.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Process Control\u003c\/strong\u003e: Ideal for refineries and petrochemical plants where a controller failure could lead to significant financial loss or safety hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComplex Logic Execution\u003c\/strong\u003e: Utilized in power generation facilities to manage high-speed PID loops and sophisticated interlocking sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Management\u003c\/strong\u003e: Acts as a central brain for managing hundreds of digital and analog points distributed across various plant sections via Vnet\/IP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Modernization\u003c\/strong\u003e: Often used as a drop-in upgrade for older CENTUM systems to transition toward modern Ethernet-based plant networking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"S41101\" suffix specifically indicate for this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The suffix code defines the hardware build: \"S\" for standard type, \"4\" for dual-redundant Vnet\/IP and power, \"1\" for 100-120V AC input, and the final \"1\" confirms the inclusion of the LFS1500 control software license.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this unit handle both analog and digital I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the AFV10D is designed to interface with the complete range of Yokogawa FIO modules, facilitating the processing of 4-20mA, thermocouple, and discrete 24V DC signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to perform maintenance on the power supply while the unit is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Because this model is configured for dual-redundant power, it is possible to replace a faulty power module while the system remains energized and the process continues to run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does Vnet\/IP improve performance over older control networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Vnet\/IP provides a 1 Gbps backbone, significantly increasing data throughput and reducing latency compared to traditional proprietary control buses, which is essential for large-scale DCS deployments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the unit come with the mounting hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This specific model is designed for a standard 19-inch rack. While integrated into the chassis design, additional side rails or specialized cabinets may be required depending on your facility's installation standard.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45878907207853,"sku":"AFV10D-S41101","price":1250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/AFV10D-S41101_3.jpg?v=1775099112"},{"product_id":"anb10d-421-yokogawa-vnet-ip-node-interface-unit-communication-module","title":"ANB10D-421 Yokogawa Vnet\/IP Node Interface Unit Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ANB10D-421 serves as a high-integrity Node Interface Unit (NIU) for the CENTUM VP and CENTUM CS 3000 control environments. This module functions as the primary communication gateway between the Field Control Station (FCS) and remote I\/O nests. By coordinating high-speed data traffic over Vnet and Vnet\/IP networks, the ANB10D-421 ensures that process variables from analog and digital modules are synchronized with the controller's scan cycles in real-time. This unit is essential for distributed architectures, allowing for centralized control over geographically dispersed field equipment while maintaining the deterministic performance required for safety-critical and high-availability industrial processes.\u003c\/p\u003e\n\u003ch3\u003eHardware Infrastructure and Interface Parameters\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-421 is engineered for continuous 24\/7 operation in industrial cabinets, featuring a robust physical build and advanced diagnostic capabilities.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Role\u003c\/strong\u003e: Remote I\/O Node Communication and Synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e: Vnet and Vnet\/IP (Configuration Dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e: Fully compatible with dual-redundant NIU configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Layouts\u003c\/strong\u003e: Star, Ring, and Redundant bus topologies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Scanning\u003c\/strong\u003e: Deterministic polling of local and remote module slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Tolerance\u003c\/strong\u003e: 0 °C to +50 °C during active operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Mass\u003c\/strong\u003e: 5.0 kg (Full assembly weight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e: 130 mm x 130 mm x 450 mm (Approximate unit size)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Standard Yokogawa I\/O backplane\/baseplate mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Conformal coating on PCB for enhanced moisture and dust resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e: Supported for modules in redundant configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStrategic Industrial Deployment\u003c\/h3\u003e\n\u003cp\u003eThis Node Interface Unit is utilized in large-scale automation projects where reliability and scalability are primary requirements.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge-Scale Refining\u003c\/strong\u003e: Facilitating communication between distant satellite instrument houses and the main control center in petrochemical facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation\u003c\/strong\u003e: Managing high-density I\/O configurations for turbine and boiler control systems where zero-latency synchronization is mandatory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing\u003c\/strong\u003e: Providing a fail-safe communication link for distributed safety loops and complex batch processing sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInfrastructure Expansion\u003c\/strong\u003e: Allowing for the seamless addition of new I\/O nodes to existing CENTUM systems without significant re-wiring of the main control station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ANB10D-421 support Vnet\/IP networks specifically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, this unit is designed to integrate seamlessly with both traditional Vnet and the modern Ethernet-based Vnet\/IP high-speed control networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to replace an ANB10D-421 module while the plant is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: In a dual-redundant configuration, the ANB10D-421 supports hot-swapping, allowing maintenance personnel to replace a module without interrupting the process control or communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of diagnostics does the module provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The NIU performs continuous health monitoring, including I\/O module presence detection, communication error reporting, and node status isolation to ensure rapid troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which specific I\/O modules can be managed by this interface unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is compatible with the full range of Yokogawa FIO (Field network I\/O) modules, including standard analog, digital, pulse, and various specialty communication modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does this module ensure deterministic control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ANB10D-421 utilizes a highly synchronized polling mechanism that aligns the data capture from field modules exactly with the Field Control Unit's internal scan cycles.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45879225352365,"sku":"ANB10D-421","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ANB10D-421.jpg?v=1775120458"}],"url":"https:\/\/www.maxwellplc.com\/collections\/yokogawa-rack-chassis.oembed","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}