{"title":"Omron PLC I\/O \u0026 Communication Modules","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eOmron\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLC I\/O Modules and Communication Units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide flexible expansion solutions for industrial automation systems. Designed for reliable signal processing and efficient data exchange, these modules extend PLC functionality across various manufacturing applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis category includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital input modules, digital output modules, analog I\/O units, temperature modules and communication interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Omron CJ and NX automation platforms.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCJ1W series I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport traditional PLC architectures with stable performance and easy integration, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNX Series I\/O units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide advanced modular automation solutions with high-speed communication and compact installation designs.\u003c\/p\u003e\n\u003cp\u003eAvailable modules include\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCJ1W-ID input units, CJ1W-OD output units, CJ1W-AD analog input modules, CJ1W-DA analog output modules and NX series I\/O units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommonly used in automated production equipment.\u003c\/p\u003e\n\u003cp\u003eOmron communication modules such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP, Serial Communication and Network Interface Units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenable seamless connection between PLC systems, HMIs, remote I\/O devices and industrial networks.\u003c\/p\u003e\n\u003cp\u003eThese products are widely applied in machine building, process automation, packaging systems, material handling and factory control projects.\u003c\/p\u003e","products":[{"product_id":"nx-ecc202-omron-ethercat-coupler-unit-nx-series","title":"NX-ECC202 Omron EtherCAT Coupler Unit NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-ECC202\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-ECC\u003c\/strong\u003e EtherCAT Coupler Unit, operates as a dedicated hardware component for fieldbus packet processing and local I\/O module slice bridging within EtherCAT real-time deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Architecture platform designator for slice-type remote I\/O and PLC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC\u003c\/strong\u003e: EtherCAT Bus Coupler unit classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e202\u003c\/strong\u003e: High-capacity execution revision supporting up to 63 connected NX I\/O slice modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-ECC202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 170 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.1 cm x 4.6 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.25 W max. (Unit power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable NX Units\u003c\/td\u003e\n\u003ctd\u003e63 Units max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherCAT protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Layer\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX (IEEE 802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps baseband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eDepends on EtherCAT master specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Method\u003c\/td\u003e\n\u003ctd\u003eGround to 100 Ohm or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Bus Execution and Firmware Management\u003c\/h3\u003e\n\u003cp\u003eThe internal NX bus controller handles data serialization between local I\/O slices and the main fieldbus trunk. High backplane bus communication velocity Licences enable sub-millisecond refresh rates across all connected I\/O channels. High-density I\/O density scaling operates under strict firmware flash compatibility routines, preventing cyclic mapping errors when expanding node configurations.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-ECC202 EtherCAT Coupler Unit\u003c\/li\u003e\n\u003cli\u003e1 x End Cover Slice (NX-END01)\u003c\/li\u003e\n\u003cli\u003e1 x Power Supply Connector Terminal Block\u003c\/li\u003e\n\u003cli\u003e1 x Functional Grounding Plate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting and Wiring Standards\u003c\/h3\u003e\n\u003ch4\u003eRail Installation and Layout\u003c\/h4\u003e\n\u003cp\u003eSnap the coupler unit onto a standard 35 mm DIN rail inside an IP54 control cabinet. Attach up to 63 NX I\/O modules to the right side of the unit, terminating the bus assembly with the included end cover.\u003c\/p\u003e\n\u003ch4\u003eEthernet Cable Termination\u003c\/h4\u003e\n\u003cp\u003eConnect industrial Category 5e shielded twisted-pair cables (STP) using RJ45 connectors to the IN and OUT EtherCAT ports. Maintain cable separation from high-voltage motor leads.\u003c\/p\u003e\n\u003ch4\u003eSystem Power and Grounding\u003c\/h4\u003e\n\u003cp\u003eSupply 24 VDC to the unit power terminals. Connect the dedicated Functional Ground (FG) terminal directly to the main cabinet earth bar with a resistance of 100 Ohm or less to suppress high-frequency noise.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan individual NX I\/O slices be hot-swapped while the EtherCAT coupler is powered?\u003c\/p\u003e\n\u003cp\u003eHot-swapping individual I\/O modules on the NX backplane bus during active operation is not supported and will trip a bus communication fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to connected I\/O output states if the main EtherCAT link disconnects?\u003c\/p\u003e\n\u003cp\u003eLoss of network frames causes output channels to immediately execute pre-programmed fail-safe fallback states, holding last value or clearing to zero.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many total I\/O slice modules can be driven by a single NX-ECC202 unit?\u003c\/p\u003e\n\u003cp\u003eThe NX-ECC202 supports a maximum stack expansion of 63 individual NX I\/O units on its right-side local bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical wiring requirements apply to the 100BASE-TX EtherCAT ports?\u003c\/p\u003e\n\u003cp\u003eUse Category 5e or higher double-shielded aluminum tape and braided STP cables with RJ45 connectors, keeping segment lengths under 100 m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the coupler unit require a dedicated end termination block on the NX bus?\u003c\/p\u003e\n\u003cp\u003eAn NX-END01 end cover must be locked onto the rightmost side of the last I\/O unit to complete the internal bus loop and seal contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the ground terminal connected to ensure proper EMC performance?\u003c\/p\u003e\n\u003cp\u003eWire the Functional Ground terminal to an earth ground bar using a dedicated wire with an impedance of 100 Ohm or less.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does firmware mismatch between the coupler and I\/O modules affect boot sequence?\u003c\/p\u003e\n\u003cp\u003eIncompatible firmware revisions prevent initialization, flashing the MS\/NS error LEDs and blocking EtherCAT process data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply sizing considerations apply to the internal NX bus power drive?\u003c\/p\u003e\n\u003cp\u003eCalculate the total current consumption of all 63 connected slices; if it exceeds the internal bus supply limit, insert additional power supply units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306593173677,"sku":"NX-ECC202","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-ECC202_3.jpg?v=1790174032"},{"product_id":"nx-od2258-omron-digital-output-unit-nx-i-o-bus","title":"NX-OD2258 Omron Digital Output Unit NX I\/O Bus","description":"\u003cp\u003eConfigured for high-speed digital switching execution in NX I\/O Bus architectures, the \u003cstrong\u003eOmron NX-OD2258\u003c\/strong\u003e (\u003cstrong\u003eNX-OD2258\u003c\/strong\u003e Digital Output Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Designation \u0026amp; Cataloging\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModule Classification: Digital Output Unit\u003c\/li\u003e\n\u003cli\u003eBase Catalog Code: NX-OD2258\u003c\/li\u003e\n\u003cli\u003eBus Integration: NX I\/O Bus\u003c\/li\u003e\n\u003cli\u003eManufacturer Identity: Omron Corporation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-OD2258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e65 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e104.5 mm x 12 mm x 80.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via NX I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Digital Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Type\u003c\/td\u003e\n\u003ctd\u003ePNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point, 1 A per NX Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Voltage at Output\u003c\/td\u003e\n\u003ctd\u003e15.0-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF\/ON Delay\u003c\/td\u003e\n\u003ctd\u003e0-0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eHigh speed, Timestamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Controller Platform Integration\u003c\/h3\u003e\n\u003cp\u003eIntegrated within modular automation networks, the unit interfaces directly through the proprietary high-speed backplane architecture of the Omron machine control ecosystem. The deterministic bus execution guarantees millisecond-level reaction times across distributed node topologies. Signal processing protocols manage internal synchronization frames to align actuation cycles with local controller timebases, reducing phase errors during multi-axis coordinate execution or high-rate sorting tasks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x NX-OD2258 Digital Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Integrated Push-In Connector\u003c\/li\u003e\n\u003cli\u003e1 x Safety and Technical Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Deployment Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module exclusively onto a DIN rail conforming to IEC 60715 dimensions using the integrated side-locking mechanism until an audible click confirms physical engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure minimum vertical and horizontal clearances of 30 mm above and below the chassis enclosure to maintain convective thermal dissipation across operational limits.\u003c\/li\u003e\n\u003cli\u003eStrip field conductors to a length of 9 mm and insert directly into the push-in spring clamp terminals without ferrules to preserve low-resistance electrical contact.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage output signal wiring through dedicated metallic cable trays separated from high-voltage AC power trunk lines by at least 100 mm to suppress electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Resolutions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum switching frequency supported by the transistor outputs?\u003c\/p\u003e\n\u003cp\u003eThe module handles discrete update loops up to the hardware switching threshold defined by the 0-0.3 ms delay parameter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the outputs protected against external inductive load kickback?\u003c\/p\u003e\n\u003cp\u003eInternal freewheeling diode protection circuits absorb reverse electromotive force transients generated by inductive actuators connected to the PNP channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of wire gauge is compatible with the push-in terminal block?\u003c\/p\u003e\n\u003cp\u003eThe connector accepts solid conductors and stranded wires ranging from 0.14 mm square to 1.5 mm square without specialized crimping tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit support hot-swapping during active controller operation?\u003c\/p\u003e\n\u003cp\u003eSystem power must be isolated prior to physical insertion or extraction of the module from the NX bus backplane to prevent bus communication corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is module power supplied across the backplane?\u003c\/p\u003e\n\u003cp\u003eInternal logic power and field supply potentials are routed via the built-in power-supply paths of the modular DIN rail bus connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the high-speed timestamp feature?\u003c\/p\u003e\n\u003cp\u003eThe hardware logs exact microsecond transition epochs for event sequence analysis and deterministic motion synchronization across the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs external fusing required for the transistor output channels?\u003c\/p\u003e\n\u003cp\u003eAlthough internal short-circuit protection exists, external fast-blow fuses rated below the 0.5 A channel limit are recommended to protect field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the enclosure ingress protection rating of the assembly?\u003c\/p\u003e\n\u003cp\u003eThe mounted hardware maintains an IP20 rating, requiring installation inside a sealed electrical control cabinet to prevent particulate and moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306593829037,"sku":"NX-OD2258","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-OD2258.jpg?v=1790174206"},{"product_id":"cj1w-id212-omron-dc-input-module-cj-series","title":"CJ1W-ID212 Omron DC Input Module CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-ID212\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-ID212\u003c\/strong\u003e DC Input Unit, operates as a dedicated hardware component for high-speed 24 VDC discrete signal sensing within CJ Series PLC backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eInput Channel Breakdown \u0026amp; Allocation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Density\u003c\/strong\u003e: Accommodates 16 high-speed DC input channels sharing 1 common electrical line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Memory Mapping\u003c\/strong\u003e: Occupies exactly 1 word (16 bits) in the CPU memory allocation map for direct digital I\/O processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Termination\u003c\/strong\u003e: Equipped with a standard front-facing removable terminal block for field conductor terminations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDC Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 points (High speed, 1 circuit, 16 points\/common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage \u0026amp; Current\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 7 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Allocation\u003c\/td\u003e\n\u003ctd\u003e1 word (16 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.13 A max. at 5 VDC (Internal backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.110 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 x 130 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Backplane Synchronization \u0026amp; Execution\u003c\/h3\u003e\n\u003cp\u003eThe module architecture interfaces directly with the system backplane to achieve deterministic signal acquisition. High-speed optocouplers isolate external field inputs while leveraging backplane bus communication velocity Licences to transfer digital states to the main processor within a single CPU scan cycle. Firmware flash compatibility across CJ Series controllers ensures predictable execution timings and seamless hardware swap behavior.\u003c\/p\u003e\n\u003ch3\u003ePackage \u0026amp; Order Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-ID212 High-Speed DC Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Product Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Wiring Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion\u003c\/strong\u003e: Align the unit guides with the CJ Series backplane slot and press firmly until both the upper and lower locking tabs lock into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring\u003c\/strong\u003e: Terminate 24 VDC field signal wires onto the removable terminal block using isolated crimp ferrules to maintain tight terminal spacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Attachment\u003c\/strong\u003e: Torque terminal screws evenly to prevent loose connections or resistance hot spots during continuous high-speed switching operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Isolation\u003c\/strong\u003e: Separate 24 VDC signal lines from high-voltage AC motor wires inside panel ducts to prevent induced electrical noise on input channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the rated operating voltage and current draw per input channel?\u003c\/p\u003e\n\u003cp\u003eEach input channel operates at a nominal input rating of 24 VDC with a typical current draw of 7 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many memory words does this 16-point input module consume in the CPU?\u003c\/p\u003e\n\u003cp\u003eThe module allocates exactly 1 word (16 bits) in the I\/O memory map of the host CPU controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal connection style is utilized for field signal wiring?\u003c\/p\u003e\n\u003cp\u003eField signals terminate via a removable terminal block, allowing unit replacement without disconnecting individual field wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much current does the unit draw from the internal 5 VDC power rail?\u003c\/p\u003e\n\u003cp\u003eThe hardware draws 0.13 A (130 mA) from the internal 5 VDC backplane bus for logic circuit operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the terminal block be safely detached while field power is applied?\u003c\/p\u003e\n\u003cp\u003eNo, field supply voltage and controller rack power must be turned off before detaching the terminal block to prevent electrical arc damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre input points divided into multiple isolated commons on this hardware?\u003c\/p\u003e\n\u003cp\u003eNo, all 16 high-speed input points share 1 single common connection point across the module terminal array.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require an external 5 VDC supply for internal operations?\u003c\/p\u003e\n\u003cp\u003eNo, internal processing power is derived directly from the system backplane's 5 VDC power supply line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are input status changes conveyed to the CPU during execution?\u003c\/p\u003e\n\u003cp\u003eInput state transitions pass through fast optical isolators directly into the CPU backplane memory buffer during each scan phase.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306595434669,"sku":"CJ1W-ID212","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-ID212.jpg?v=1788102155"},{"product_id":"cj1w-id261-omron-digital-input-module-cj-series","title":"CJ1W-ID261 Omron Digital Input Module CJ-Series","description":"\u003cp\u003eConfigured for 64-channel DC24 V discrete acquisition on the CJ I\/O Bus, the \u003cstrong\u003eOmron CJ1W-ID261\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-ID261\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution via two 40-pin FCN interfaces.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCJ1W-ID261: Base catalog number, 64-point DC24 V input, Fujitsu\/OTAX-compatible FCN connector, basic I\/O class.\u003c\/li\u003e\n\u003cli\u003eCJ1W: CJ-series 35 mm wide I\/O family prefix.\u003c\/li\u003e\n\u003cli\u003eID: Digital input function code.\u003c\/li\u003e\n\u003cli\u003e261: 64-point high-density variant with 16-point\/common grouping (4 commons).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and Mechanical Data\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eCJ I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Class\u003c\/td\u003e\n\u003ctd\u003eBasic I\/O Unit, Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e64 (16 points per common, 4 commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDC24 V, PNP\/NPN selectable by wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Input Voltage\u003c\/td\u003e\n\u003ctd\u003e20.4 - 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA typ. at 24 VDC (5.6 kOhm impedance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Threshold\u003c\/td\u003e\n\u003ctd\u003e19 VDC \/ 3 mA min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Threshold\u003c\/td\u003e\n\u003ctd\u003e5 VDC \/ 1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF\/ON Delay\u003c\/td\u003e\n\u003ctd\u003e0 - 32 ms (default 8 ms, software filter settable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connector\u003c\/td\u003e\n\u003ctd\u003e2 x 40-pin FCN (Fujitsu\/OTAX compatible), plug not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM Terminals\u003c\/td\u003e\n\u003ctd\u003e8 (A9\/A18, B9\/B18 per connector paired)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Backplane Current\u003c\/td\u003e\n\u003ctd\u003e90 mA max from 5 VDC CJ bus (0.09 A per Omron lineup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min (DC100 V, external to GR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003eAC1000 V 1 min, 10 mA max leak (external to GR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 - 55 deg C (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 - 75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 - 90 %RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.45 W max (90 mA x 5 VDC bus side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (user data) \/ 110 g max per Omron manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e90 mm (H) x 31 mm (W) x 66.5 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, CJ rack slot, occupies 2 basic I\/O unit addresses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCJ Bus I\/O Density and Connector Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-ID261 executes I\/O density scaling on the CJ I\/O Bus by mapping 64 inputs into 4 allocated words (16 points\/common). Backplane communication follows the CJ dedicated I\/O bus velocity license, not Profinet or EtherNet\/IP; word refresh is driven by CPU cyclic scan. Firmware flash compatibility is fixed to CJ1M\/CJ2M\/CJ2H CPU units running unit information table V3.x or later. Connector pinout conforms to Fujitsu FCN-40R-TV and OTAX equivalents; no MIL or removable screw terminal block is fitted. Simultaneous ON loading is restricted to 50 % per common (8 of 16 points) at DC24 V without derating external supply current.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x CJ1W-ID261 module (factory sealed, label barcode intact)\u003c\/li\u003e\n\u003cli\u003e0 x FCN connector plugs (must order separately, e.g. GPN-CJ25 or equivalent 40-pin Fujitsu\/OTAX hood)\u003c\/li\u003e\n\u003cli\u003e0 x termination cables (Omron GPP-CJ25L pre-wired cable optional)\u003c\/li\u003e\n\u003cli\u003e0 x mounting hardware (DIN clip integrated into module body)\u003c\/li\u003e\n\u003cli\u003e1 x printed warning slip (omron static handling, not full manual)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSite Wiring and Mounting Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupply the CJ rack 5 VDC backplane before inserting the module; do not hot-swap while CPU in RUN unless rack supports live insertion.\u003c\/li\u003e\n\u003cli\u003eWire COM0-COM3 pairs (A9+A18, B9+B18 on each FCN) to identical polarity; mixing source\/sink on one common forces undefined ON state.\u003c\/li\u003e\n\u003cli\u003eFor PNP sensors, tie COM to 24 VDC positive; for NPN, tie COM to 0 VDC. Sensor leakage must stay below 1 mA in OFF band.\u003c\/li\u003e\n\u003cli\u003eKeep FCN cable bundles away from 200 VAC feeder trays by minimum 100 mm or use grounded separator plate.\u003c\/li\u003e\n\u003cli\u003eDrain shield of multi-core sensor cable to cabinet ground, not to COM terminal.\u003c\/li\u003e\n\u003cli\u003eSet input filter (0\/1\/2\/4\/8\/16\/32 ms) in CX-Programmer unit setup; default 8 ms masks contact bounce but rejects sub-ms pulses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes CJ1W-ID261 support hot-swapping on a live CJ2M rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module is not rated for live insertion. Remove 5 VDC backplane power or place CPU to STOP before extracting or seating the unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the same common terminal mix PNP and NPN sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Each 16-point common (COM0 to COM3) must be uniformly wired either to 24 VDC (PNP) or 0 VDC (NPN). Mixed polarity on one common causes false ON.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the actual backplane load drawn from the CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaximum 90 mA from the 5 VDC CJ I\/O Bus rail. It draws 0 A from 24 VDC field supply; field power is fully external per common.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy are there 8 COM terminals for 64 inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e64 inputs are grouped 16 per common across 4 groups. Each group has two physical COM pins (A9\/A18 etc.) that must be paralleled to the same potential, not used as separate commons.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FCN plug shipped with the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Per Omron lineup note, \"connector model does not include connector\". Order Fujitsu FCN-40R-TV hood plus crimp contacts or Omron GPN-CJ25 separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if input filter is set to 0 ms?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e0 ms disables digital debounce; ON\/OFF reflect raw bus sampling limited by hardware propagation (~sub-ms to 1 ms). Use only with electronic sensors, never mechanical contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many CJ1W-ID261 can one CJ2M-CPU mount?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLimited by basic I\/O unit count (max 10 expansion units on CJ1M, 40 on CJ2H via expansion racks) and 5 VDC backplane budget. 90 mA each: 10 pcs = 900 mA, within typical CPU 5 VDC capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require firmware download for CJ2H compatibility?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo firmware flash on the module itself. Compatibility is controlled by CPU unit information table; older CPUs may need CX-Programmer V9+ to allocate 4 input words correctly.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306596253869,"sku":"CJ1W-ID261CW","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-ID261_4.jpg?v=1787614187"},{"product_id":"omron-cj1w-ia111-cj1-series-ac-input-unit","title":"Omron CJ1W-IA111 CJ1 Series AC Input Unit","description":"\u003cp\u003eConfigured for 100 to 120 VAC digital signal acquisition in CJ1 PLC systems, the \u003cstrong\u003eOmron CJ1W-IA111\u003c\/strong\u003e (\u003cstrong\u003eCJ1W\u003c\/strong\u003e AC Input Unit) provides direct physical execution of field-level AC state sensing and internal logic memory mapping.\u003c\/p\u003e\n\u003ch3\u003eHardware Nomenclature \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJ1W\u003c\/strong\u003e: CJ Series I\/O module system platform designator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIA\u003c\/strong\u003e: Alternating Current (AC) digital input circuit interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e111\u003c\/strong\u003e: 16-point input density configuration with 100 to 120 VAC operational rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-IA111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (Shipping Weight 2.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 120 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 inputs (16 points, 1 common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage \u0026amp; Current\u003c\/td\u003e\n\u003ctd\u003e100 to 120 VAC (+10%\/-15%), 7 mA (100 V, 50 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.09 A at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block (18-point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWord Allocation\u003c\/td\u003e\n\u003ctd\u003e1 word in CPU I\/O memory area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Synchronization \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module communicates across the internal CJ-series system backplane bus to transfer digital status bits directly to the CPU unit memory. High-speed backplane interface logic maintains deterministic scan timing while ensuring cross-generation firmware flash compatibility for seamless system expansion without timing jitter.\u003c\/p\u003e\n\u003ch3\u003eKit Packaging Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-IA111 AC input module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable 18-point wiring terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring \u0026amp; Physical Cabinet Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Installation\u003c\/p\u003e\n\u003cp\u003eSecure field cables to the removable terminal block before attaching it to the front connector frame to avoid applying mechanical strain to internal PCB traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLine Isolation\u003c\/p\u003e\n\u003cp\u003eSeparate 100 VAC input signal wiring from low-voltage DC communication cables inside panel wire ducts to mitigate inductive noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrame Grounding\u003c\/p\u003e\n\u003cp\u003eEnsure the CJ-series CPU and backplane base units bond directly to a copper functional earth bus bar via low-impedance grounding conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input voltage rating for the CJ1W-IA111 module?\u003c\/p\u003e\n\u003cp\u003eThe module accepts 100 to 120 VAC operating input levels at 50\/60 Hz frequency ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many CPU memory words does this input unit occupy?\u003c\/p\u003e\n\u003cp\u003eThe module allocates exactly 1 word (16 bits) within the primary CPU I\/O memory table.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-IA111 on a running backplane?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting the module while the PLC backplane is energized damages internal backplane bus drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many commons are shared across the 16 input points?\u003c\/p\u003e\n\u003cp\u003eAll 16 digital input points connect to a single shared common terminal on the front block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the current draw from the internal 5 VDC logic bus?\u003c\/p\u003e\n\u003cp\u003eThe internal circuit draws a maximum current of 0.09 A (90 mA) from the 5 VDC system power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan AC input signals be mixed with DC voltage sources on this unit?\u003c\/p\u003e\n\u003cp\u003eNo, input circuitry is designed strictly for 100 to 120 VAC signals; applying DC voltage will prevent correct state detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of field wiring connector is integrated onto the housing?\u003c\/p\u003e\n\u003cp\u003eThe front interface utilizes a removable 18-point screw terminal block for field wiring connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature conditions are required for normal operation?\u003c\/p\u003e\n\u003cp\u003eOperating environments must maintain non-condensing relative humidity within an ambient range of 0 deg C to 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306596745389,"sku":"CJ1W-IA111","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_cj1w-ia111_5.jpg?v=1787613451"},{"product_id":"nx-od5256-5-omron-digital-output-unit-nx-series","title":"NX-OD5256-5 Omron Digital Output Unit NX Series","description":"\u003cp\u003eThe \u003cb\u003eOmron NX-OD5256-5\u003c\/b\u003e, also cataloged as the \u003cb\u003eNX-OD5256-5\u003c\/b\u003e Digital Output Unit, operates as a dedicated hardware component for high-density discrete signal execution within NX I\/O Bus platforms.\u003c\/p\u003e\n\u003ch3\u003eVariant Architecture \u0026amp; Designation Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBase Platform\u003c\/b\u003e: NX Series Remote I\/O System.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eModule Code\u003c\/b\u003e: OD5256 designation specifies 16-channel PNP switching configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSuffix -5\u003c\/b\u003e: Indicates synchronous I\/O refreshing support with high-speed response behavior on the EtherCAT network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNX-OD5256-5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBus System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNX I\/O Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePNP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4 to 28.8 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per point (4.0 A per unit maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOFF\/ON Delay Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 to 1.0 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-wire screwless push-in terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRefresh Processing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSynchronous, Standard speed, Free running\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.085 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.95 cm x 3.00 cm x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Shipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.000 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling \u0026amp; Deterministic Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe NX-OD5256-5 scales I\/O density within compact DIN-rail footprints while leveraging the internal NX backplane bus communication velocity. Channel switching synchronized to the EtherCAT master clock minimizes output jitter across distributed control nodes. Integrated PNP switching circuits incorporate internal thermal shutdown and short-circuit protection features to maintain deterministic outputs under inductive load transients.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Omron NX-OD5256-5 Digital Output Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Integrated Screwless Terminal Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Module Side Connector Cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Orientation\u003c\/p\u003e\n\u003cp\u003eEnsure vertical DIN-rail mounting with adequate clearance (minimum 30 mm top\/bottom) for airflow and convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Rules\u003c\/p\u003e\n\u003cp\u003eStrip solid or ferruled conductors to 8 mm. Insert directly into 1-wire push-in terminals without tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding and Shielding\u003c\/p\u003e\n\u003cp\u003eConnect the DIN rail directly to protective earth (PE). Keep 24 VDC load wiring isolated from high-voltage motor cables to reduce EMI coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed on the NX I\/O bus for this module?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting the unit while the backplane power supply is active can cause hardware damage or communication loss on the bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the current capacity per channel?\u003c\/p\u003e\n\u003cp\u003eEach output channel handles up to 0.5 A continuous current at 24 VDC, provided total unit current does not exceed rated limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require external output power?\u003c\/p\u003e\n\u003cp\u003eYes, an external 24 VDC power supply must be wired to the terminal block to energize the PNP output switching circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does synchronous output processing function?\u003c\/p\u003e\n\u003cp\u003eOutput updating synchronizes directly with the EtherCAT communications cycle time, eliminating cycle-to-cycle signal latency variability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan inductive loads be wired directly to the output terminals?\u003c\/p\u003e\n\u003cp\u003eYes, though adding external flyback diodes across heavy inductive relay coils is recommended to suppress back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire gauges are compatible with the push-in terminal block?\u003c\/p\u003e\n\u003cp\u003eThe push-in terminal accepts solid or ferruled copper wires ranging from AWG 24 to AWG 16 (0.2 to 1.5 mm2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response delay time for state changes?\u003c\/p\u003e\n\u003cp\u003eTurn-on and turn-off propagation delays range between 0.5 ms and 1.0 ms under standard operational loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are channel states visually indicated on the unit?\u003c\/p\u003e\n\u003cp\u003eIndividual green LED indicators on the front panel illuminate when specific output points transition to the active ON state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306597335213,"sku":"NX-OD5256-5","price":124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_nx-od5256-5_2.jpg?v=1787612423"},{"product_id":"cj1w-od263-omron-cj-series-transistor-output-module","title":"CJ1W-OD263 Omron CJ Series Transistor Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-OD263\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-OD263\u003c\/strong\u003e Transistor Output Unit, operates as a dedicated hardware component for high-density sinking DC switching within CJ Series PLC backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eOutput Configuration \u0026amp; Interface Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Architecture\u003c\/strong\u003e: Features 64 discrete transistor outputs configured for sinking operation (NPN open collector).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e: Operates across a voltage range of 12 to 24 VDC with a maximum switching current of 0.3 A per point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Arrangement\u003c\/strong\u003e: Organized into 4 shared groups (16 points per common) terminating through dual MIL connector interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-OD263\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTransistor Output Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e64 points (Sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC, 0.3 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommons\u003c\/td\u003e\n\u003ctd\u003e16 points per common (4 commons total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eMIL connector (40-pin x 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e170 mA max. at 5 VDC (Internal backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.110 kg (Approx. 110 g net)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e180 x 130 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe high-density output logic interfaces across internal bus circuits utilizing deterministic backplane bus communication velocity Licences. Fast signal execution ensures rapid updates during sequential logic scanning. Integrated channel-to-channel group isolation protects processing components against external switching noise, while firmware flash compatibility maintains seamless operation across various CJ Series CPU base plates and expansion racks.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-OD263 Transistor Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Connector Protective Cover Set\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring \u0026amp; Physical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting\u003c\/strong\u003e: Slide the module into the CPU rack or expansion rack slot until the top and bottom lock levers click firmly into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMIL Wiring Connection\u003c\/strong\u003e: Secure compatible 40-pin MIL connector cables (such as OMRON XW2Z series) to the front dual connectors, ensuring latches lock completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Verification\u003c\/strong\u003e: Verify external DC power polarity (12 to 24 VDC) across the common supply terminals before applying load current to prevent transistor damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Mitigation\u003c\/strong\u003e: Route high-density DC output cables away from high-voltage AC lines and VFD power conduits to prevent inductive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the output circuit type utilized by this 64-point module?\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes sinking (NPN) transistor outputs where the module switches the negative side of the connected load to ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat interface connector is required to wire this high-density unit?\u003c\/p\u003e\n\u003cp\u003eField wiring requires standard 40-pin MIL connectors or dedicated pre-wired terminal block cables connecting to the dual front sockets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum switching current allowable per output channel?\u003c\/p\u003e\n\u003cp\u003eEach individual output point supports a maximum switching current load of 0.3 A across an operating range of 12 to 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the 64 output points divided across the common terminals?\u003c\/p\u003e\n\u003cp\u003eThe 64 points are split into 4 independent common groups, with each common line handling 16 individual output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much continuous current does the module draw from the 5 VDC backplane?\u003c\/p\u003e\n\u003cp\u003eInternal logic and drive circuits draw a maximum current of 170 mA directly from the 5 VDC system backplane power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported when disconnecting the MIL connectors?\u003c\/p\u003e\n\u003cp\u003eNo, external 24 VDC field power and system rack power must be turned off before disconnecting MIL cables or removing the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat surge protection is recommended for inductive loads attached to outputs?\u003c\/p\u003e\n\u003cp\u003eInductive loads such as solenoid valves or relays should have freewheeling diodes installed directly across the load terminals to suppress back-EMF.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan outputs operate with voltages lower than 12 VDC?\u003c\/p\u003e\n\u003cp\u003eThe internal switching circuits are optimized for 12 to 24 VDC nominal operation; running below 10.2 VDC may result in incomplete load switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306597925037,"sku":"CJ1W-OD263","price":268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-OD263_1.jpg?v=1788101980"},{"product_id":"nx-ecc201-omron-ethercat-coupler-unit-nx-series","title":"NX-ECC201 Omron EtherCAT Coupler Unit NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-ECC201\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-ECC201\u003c\/strong\u003e EtherCAT Coupler Unit, operates as a dedicated hardware component for fieldbus data bridging and internal bus communication within EtherCAT network platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Designation Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular slice I\/O system platform identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEC\u003c\/strong\u003e: Communication unit classification (EtherCAT interface).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC\u003c\/strong\u003e: Bus coupler functional type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e201\u003c\/strong\u003e: Standard performance revision with 10 W internal bus power capacity and 34-byte I\/O data mapping size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance \u0026amp; Module Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable style=\"width: 99.9906%; height: 313.125px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003cth style=\"width: 66.2199%; height: 19.5703px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 28.5215%; height: 19.5703px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003eNX-ECC201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e10.0 cm x 4.6 cm x 7.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eUnit Power Supply Rated Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eNX Unit Power Supply Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e10 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eNX Unit Power Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e1.45 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eI\/O Power Supply Rated Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e5 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eMax Current of I\/O Power Supply\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eCurrent Consumption (I\/O Power)\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eI\/O Data Size\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e34 \/ 0 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eNumber of I\/O Entry Mappings\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e2 \/ 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 66.2199%; height: 19.5703px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 28.5215%; height: 19.5703px;\"\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Synchronization \u0026amp; Deterministic Backplane Execution\u003c\/h3\u003e\n\u003cp\u003eThe bus coupler processes incoming EtherCAT frames to drive connected slice I\/O modules with deterministic synchronization. High backplane bus communication velocity guarantees real-time cycle times across attached local I\/O nodes. Flash firmware compatibility inside the coupler maintains consistent protocol execution, allowing flexible I\/O density scaling without introducing backplane latency or data mapping mismatches.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-ECC201 EtherCAT Coupler Unit\u003c\/li\u003e\n\u003cli\u003e2 x EtherCAT RJ45 Connector Covers\u003c\/li\u003e\n\u003cli\u003e1 x End Cover Unit\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Power Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Assembly\u003c\/strong\u003e: Hook the upper latch of the coupler onto a standard 35 mm DIN rail, press the module backward until the locking mechanism engages, and slide the end cover against the rightmost slice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Power Connection\u003c\/strong\u003e: Connect a 24 VDC external power supply to the unit power terminals using AWG 24 to AWG 16 conductors to drive the internal NX bus power rail up to 10 W max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Power Connection\u003c\/strong\u003e: Wire a separate 5 to 24 VDC power feed to the I\/O supply terminals, verifying total connected field current does not exceed the maximum 4 A rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherCAT Cabling\u003c\/strong\u003e: Insert Category 5e or higher shielded twisted-pair (STP) Ethernet cables into the RJ45 IN and OUT ports, securing the shield through functional earth connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational \u0026amp; Diagnostic FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if total slice module power exceeds the 10 W internal bus limit?\u003c\/p\u003e\n\u003cp\u003eAn additional NX-PF power feed unit must be inserted into the slice rack to extend backplane logic power capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the coupler support module hot-swapping on an active EtherCAT network?\u003c\/p\u003e\n\u003cp\u003eNo, replacing or disconnecting slice units requires shutting off power to the bus coupler segment to prevent internal backplane communication errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum field current can be passed through the I\/O power supply terminals?\u003c\/p\u003e\n\u003cp\u003eThe integrated I\/O power bus terminals handle a maximum continuous current load of 4 A across all downstream modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are network speed and node addresses configured on the unit?\u003c\/p\u003e\n\u003cp\u003eNode addresses are assigned via hardware rotary switches on the front panel, while communication speed is fixed at 100 Mbps full duplex per EtherCAT specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the coupler indicate EtherCAT communication status?\u003c\/p\u003e\n\u003cp\u003eFront panel LED indicators (L\/A IN, L\/A OUT, RUN, and ERR) signal physical link state, network operational status, and packet transmission errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input\/output data memory size allocated by the coupler?\u003c\/p\u003e\n\u003cp\u003eThe unit allocates an I\/O data size of 34 bytes for input data and 0 bytes for output data, supporting up to 2 input mapping entries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire conductor size is recommended for the terminal block connections?\u003c\/p\u003e\n\u003cp\u003eSolid or stranded copper conductors ranging from AWG 24 to AWG 16 with crimped ferrules should be used for push-in terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs galvanic isolation provided between the EtherCAT network and internal logic circuits?\u003c\/p\u003e\n\u003cp\u003eYes, internal optical isolation isolates the fieldbus RJ45 communication ports from the internal NX backplane power and logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306598908077,"sku":"NX-ECC201","price":221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ecc201-1_3.jpg?v=1790392334"},{"product_id":"cj1w-ia201-omron-cj-series-ac-input-module","title":"CJ1W-IA201 Omron CJ Series AC Input Module","description":"\u003cp\u003eConfigured for 200 VAC discretely switched field signal detection within CJ Series PLC backplane architectures, the \u003cstrong\u003eOmron CJ1W-IA201\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-IA201\u003c\/strong\u003e AC Input Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eFunctional Configuration \u0026amp; Signal Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Configuration\u003c\/strong\u003e: Features 8 high-voltage AC input points operating on a single shared common line across 1 discrete circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: Standard operational voltage ranges from 200 to 240 VAC at 50\/60 Hz, accommodating operating variations between 170 and 264 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Load\u003c\/strong\u003e: Draws a nominal input current of 9 mA typical at 200 VAC (50 Hz) and 11 mA typical at 200 VAC (60 Hz), with input impedance set to 21 kOhm at 50 Hz and 18 kOhm at 60 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-IA201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAC Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 points (1 circuit, 8 points\/common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e170 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e120 VAC min. \/ 4 mA min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e40 VAC max. \/ 2 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Response Time\u003c\/td\u003e\n\u003ctd\u003e18.0 ms max. (Default setting: 8 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Response Time\u003c\/td\u003e\n\u003ctd\u003e48.0 ms max. (Default setting: 8 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2,000 VAC between external terminals and GR terminal for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA max. at 5 VDC (Internal backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.130 kg (130 g max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e149 x 115 x 63 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eScalable I\/O Density \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal logic circuitry interface scales signal acquisition speed across the backplane bus communication velocity Licences without degrading system response times. High-density I\/O density scaling allows full simultaneous 100% point activation (8 points ON simultaneously) without exceeding system thermal limits. Integrated isolation circuits protect internal CPU architecture, while hardware flash compatibility ensures predictable execution cycles across varying controller chassis configurations.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-IA201 AC Input Module\u003c\/li\u003e\n\u003cli\u003e1 x Removable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring \u0026amp; Mounting Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Installation\u003c\/strong\u003e: Insert the module firmly into the CJ Series CPU rack or Expansion rack slot until the upper and lower locking levers snap securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Connection\u003c\/strong\u003e: Wire 200 to 240 VAC signal lines directly to the removable terminal block using proper crimp terminals. Ensure line voltage is verified prior to energizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Terminal Setup\u003c\/strong\u003e: Ensure the GR ground terminal is linked to a heavy-gauge protective earth bus with ground resistance under 100 ohm to guarantee insulation isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Keep 200 VAC input field cables isolated from low-voltage DC lines and communication cables in control panels to reduce crosstalk interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response delay when an input signal transitions from OFF to ON?\u003c\/p\u003e\n\u003cp\u003eThe hardware maximum ON response time is 18.0 ms, though internal filtering defaults to an 8 ms response configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan all 8 AC input channels be energized simultaneously during operation?\u003c\/p\u003e\n\u003cp\u003eYes, the module supports a 100% simultaneous ON factor, allowing all 8 points on the common line to operate at 240 VAC concurrently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage threshold guarantees an ON state signal detection?\u003c\/p\u003e\n\u003cp\u003eAn input signal requires a minimum threshold of 120 VAC and 4 mA current to reliably drive the channel into a recognized ON state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat level of electrical isolation is provided between terminals and ground?\u003c\/p\u003e\n\u003cp\u003eThe module withstands 2,000 VAC at 50\/60 Hz for 1 minute between external field terminals and the GR terminal with under 10 mA leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much current does the unit draw from the internal 5 VDC backplane?\u003c\/p\u003e\n\u003cp\u003eInternal logic circuitry consumes a maximum current load of 80 mA from the 5 VDC system backplane power rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping allowed for this AC input terminal block during operation?\u003c\/p\u003e\n\u003cp\u003eNo, field voltage must be powered down and backplane power disconnected before removing the unit or terminal block to avoid component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the applied voltage drops below 40 VAC?\u003c\/p\u003e\n\u003cp\u003eAny voltage level of 40 VAC or below with current under 2 mA guarantees the channel registers a clear OFF state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require an external power supply for internal logic?\u003c\/p\u003e\n\u003cp\u003eNo, internal processing circuitry runs directly off the 5 VDC backplane bus, while inputs operate on the external 200 VAC signal source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306605330605,"sku":"CJ1W-IA201","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-IA201.jpg?v=1788101867"},{"product_id":"omron-cj1w-od213-transistor-output-unit-cj-series","title":"Omron CJ1W-OD213 Transistor Output Unit CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-OD213\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-OD213\u003c\/strong\u003e Transistor Output Unit, operates as a dedicated hardware component for high-speed sinking discrete load switching within CJ Series backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Circuitry \u0026amp; Interface Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Density\u003c\/strong\u003e: Contains 16 discrete output channels wired across a single common circuit (16 points\/common).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Logic\u003c\/strong\u003e: Configured for sinking (NPN) switching operations rated at 24 VDC load voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Characteristics\u003c\/strong\u003e: Delivers rapid switching performance with a maximum ON response time of 15 us and OFF response time of 80 us.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-OD213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTransistor Output Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 sinking outputs (1 circuit, 16 points\/common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Load Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\/point, 5.0 A\/Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current Limit\u003c\/td\u003e\n\u003ctd\u003e4.0 A\/point max. (10 ms max. pulse duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 V max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Draw\u003c\/td\u003e\n\u003ctd\u003e150 mA max. at 5 VDC (Backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC, 55 mA min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. between terminals and GR terminal at 100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC between terminals and GR terminal for 1 min (10 mA max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg (110 g max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Shipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg (Including outer protective packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 x 130 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus Sync\u003c\/h3\u003e\n\u003cp\u003eDiscrete output bit transitions synchronize directly to the CPU backplane via optimized backplane bus communication velocity Licences. High-speed output switching operates without added processing overhead, supporting rapid physical actuation cycles. Hardware flash compatibility and stable backplane mapping maintain consistent signal updates across expanded CJ Series rack layouts.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-OD213 Transistor Output Module\u003c\/li\u003e\n\u003cli\u003e1 x Detachable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Installation\u003c\/strong\u003e: Align module slots with the CJ Series backplane standard rack rail and press firmly until locking clips engage fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Power Supply\u003c\/strong\u003e: Wire an external 24 VDC (20.4 to 26.4 VDC) power supply providing at least 55 mA to the dedicated external power terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Connections\u003c\/strong\u003e: Wire NPN field loads to output terminals; ensure total load current does not exceed 0.5 A per point or 5.0 A total across the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding\u003c\/strong\u003e: Secure a low-impedance ground wire from the GR terminal to protective earth (100 ohm max resistance) to satisfy insulation testing parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat switching type is implemented on the output channels of this module?\u003c\/p\u003e\n\u003cp\u003eThe module utilizes NPN sinking transistor outputs where connected loads switch to the negative supply rail when active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the individual point and total module load current limits?\u003c\/p\u003e\n\u003cp\u003eEach output point carries a maximum load of 0.5 A, while total simultaneous current across the entire 16-point module must not exceed 5.0 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs internal fuse protection built into the output circuits?\u003c\/p\u003e\n\u003cp\u003eNo internal fuses are integrated into the output circuits; external current-limiting protection or inline fusing should be installed per circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the ON and OFF switching speeds of the output transistors?\u003c\/p\u003e\n\u003cp\u003eThe NPN output transistors feature an ON response time of 15 us max. and an OFF response time of 80 us max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power source is necessary for proper module operation?\u003c\/p\u003e\n\u003cp\u003eAn external 24 VDC power supply operating between 20.4 and 26.4 VDC with a minimum current capacity of 55 mA is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much current does this card draw from the internal 5 VDC backplane?\u003c\/p\u003e\n\u003cp\u003eThe internal logic circuitry draws a maximum current of 150 mA from the internal 5 VDC backplane bus rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum peak inrush current capability per output point?\u003c\/p\u003e\n\u003cp\u003eEach output channel can tolerate a maximum surge inrush current of 4.0 A for a duration up to 10 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be hot-swapped while backplane power is active?\u003c\/p\u003e\n\u003cp\u003eNo, active rack power and external 24 VDC power must be isolated before removing or inserting the unit to prevent hardware faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306607984813,"sku":"CJ1W-OD213","price":255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-OD213_1.jpg?v=1788102547"},{"product_id":"cj1w-da021-omron-cj-series-analog-output-module","title":"CJ1W-DA021 Omron CJ Series Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-DA021\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-DA021\u003c\/strong\u003e Special I\/O Unit, operates as a dedicated hardware component for converting 16-bit binary digital values into precise analog output signals within CJ Series backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Configuration \u0026amp; Signal Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e: Features 2 independent analog output channels with a conversion resolution of 1\/40,000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Ranges\u003c\/strong\u003e: Configurable per channel for 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Isolation\u003c\/strong\u003e: Photocoupler isolation separates internal controller signals from field I\/O terminals, with no isolation between individual analog output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-DA021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e1\/40,000 (16-bit binary set data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eMax. current: 12 mA per point, Output impedance: 0.5 Ohm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Characteristics\u003c\/td\u003e\n\u003ctd\u003eMax. permissible load resistance: 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Scheme\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler between I\/O and controller (non-isolated between channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Terminals\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 120 mA max. (Internal backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+10% \/ -15%), 140 mA max. (Inrush: 20 A max., 1 ms min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 x 130 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Backplane Synchronization \u0026amp; Execution\u003c\/h3\u003e\n\u003cp\u003eInternal digital-to-analog conversion logic maps directly to system memory across optimized backplane bus communication velocity Licences. High-density scaling algorithms ensure rapid output updates during active PLC execution scans. Photocoupler signal separation preserves internal logic processing circuits, while hardware flash compatibility guarantees uniform conversion timing across varying controller baseplate setups.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-DA021 Analog Output Module\u003c\/li\u003e\n\u003cli\u003e1 x 18-point Detachable Terminal Block (M3 Screws)\u003c\/li\u003e\n\u003cli\u003e1 x Product Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting\u003c\/strong\u003e: Insert the module into the CJ Series backplane slot until top and bottom mounting clips securely latch into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Connection\u003c\/strong\u003e: Supply external 24 VDC (+10% \/ -15%) auxiliary power to dedicated terminal block points to power output drive circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cabling\u003c\/strong\u003e: Use twisted-pair shielded cables for all analog voltage and current loops to suppress electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Termination\u003c\/strong\u003e: Ground signal wire shielding at the module ground terminal using a short wire stub, keeping ground resistance below 100 ohm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal ranges can be configured on the analog output channels?\u003c\/p\u003e\n\u003cp\u003eOutputs can be set independently for 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA across both channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the conversion resolution capability of this module?\u003c\/p\u003e\n\u003cp\u003eThe unit delivers a high-precision digital-to-analog conversion resolution of 1\/40,000 using 16-bit binary set data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power source is required to drive the output channels?\u003c\/p\u003e\n\u003cp\u003eAn external supply of 24 VDC (+10% \/ -15%) drawing up to 140 mA is required for field circuit operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much current does the unit draw from the internal 5 VDC backplane?\u003c\/p\u003e\n\u003cp\u003eThe module consumes a maximum current load of 120 mA from the internal 5 VDC backplane power supply rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs there channel-to-channel electrical isolation between the 2 outputs?\u003c\/p\u003e\n\u003cp\u003eNo, photocoupler isolation is provided between field I\/O and the backplane controller logic, but not between individual output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal connection format is used for external signal wiring?\u003c\/p\u003e\n\u003cp\u003eField wiring attaches to an 18-point detachable terminal block secured with standard M3 screw connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable load resistance for current output mode?\u003c\/p\u003e\n\u003cp\u003eWhen configured for 4 to 20 mA current output, the maximum permissible load resistance is strictly 600 Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported when detaching the terminal block?\u003c\/p\u003e\n\u003cp\u003eNo, external 24 VDC power and backplane supply must be de-energized before removing the module or terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306608967853,"sku":"?CJ1W-DA021","price":151.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-DA021_3.jpg?v=1788102436"},{"product_id":"nx-ad3203-omron-analog-input-module-nx-series","title":"NX-AD3203 Omron Analog Input Module NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-AD3203\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-AD3203\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for 4-20 mA analog signal acquisition within Sysmac Machine Automation Controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-AD3203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg (70 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.1 cm x 1.2 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 0.65 W (NX bus power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eSingle-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 us\/point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Refreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Terminals\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (12 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic PLC Integration and Bus Velocity\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with the primary controller via the high-speed NX bus backplane, transmitting digitized current values over EtherNet\/IP deterministic networks or EtherCAT bus couplers. Direct firmware flash compatibility enables seamless module identification and online parameter configuration through Sysmac Studio. High density I\/O scaling allows up to 63 expansion slices to be stacked per bus coupler without sacrificing conversion performance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDIN-Rail Assembly and Mechanical Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the module onto a standard 35 mm DIN rail and engage the side bus connector latch securely with adjacent NX units.\u003c\/li\u003e\n\u003cli\u003eEnsure clear vertical air circulation space of at least 30 mm above and below the module housing inside the enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Wiring and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStrip field current loop conductors to 8-10 mm and insert directly into the screwless push-in clamping terminal block.\u003c\/li\u003e\n\u003cli\u003eConnect 4-20 mA signal shields to the functional ground bar on the cabinet backplate to minimize high-frequency electrical noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivery time: 3-5 days when payment finish\u003c\/li\u003e\n\u003cli\u003eGlobal dispatch via DHL, FEDEX, or UPS courier services\u003c\/li\u003e\n\u003cli\u003ePackaged in anti-static industrial packaging with high-density shock-absorbing foam\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Query Resolution\u003c\/h3\u003e\n\u003cp\u003eQ: Can the NX-AD3203 be hot-swapped while the NX bus power supply is active?\u003c\/p\u003e\n\u003cp\u003eA: No, power to the NX bus power supply segment must be disconnected prior to removing or inserting the module to prevent backplane damage.\u003c\/p\u003e\n\u003cp\u003eQ: What is the internal input resistance across the current terminal pair?\u003c\/p\u003e\n\u003cp\u003eA: The module has an internal input impedance of 250 ohm across each of its 4 single-ended current input channels.\u003c\/p\u003e\n\u003cp\u003eQ: How is broken wire detection handled on 4-20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eA: The module detects input currents falling below the valid threshold (less than 3.2 mA) and reports an analog input disconnect fault flag to the system controller.\u003c\/p\u003e\n\u003cp\u003eQ: What is the overall conversion time for all 4 channels?\u003c\/p\u003e\n\u003cp\u003eA: Processing occurs sequentially at 250 us per point, resulting in a complete 4-channel conversion loop time of 1 ms during Free-Run refreshing.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306611490989,"sku":"NX-AD3203","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ad3203_1.jpg?v=1790392264"},{"product_id":"nx-ad3208-omron-analog-input-unit-nx-series","title":"NX-AD3208 Omron Analog Input Unit NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-AD3208\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-AD3208\u003c\/strong\u003e Analog Input Unit, operates as a dedicated hardware component for high-speed current signal acquisition within EtherCAT and EtherNet\/IP control networks.\u003c\/p\u003e\n\u003ch3\u003eInternal Model Structure \u0026amp; Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Slice I\/O modular system family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAD\u003c\/strong\u003e: Analog input unit category.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: 4 input points configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: 4 to 20 mA analog input current range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e08\u003c\/strong\u003e: High-resolution (1\/30000) performance tier with 10 us\/point conversion speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-AD3208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.2 cm x 10.0 cm x 7.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.30 W max (CPU unit), 0.95 W max (Coupler unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Conversion Range\u003c\/td\u003e\n\u003ctd\u003e-5 to 105% (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/30000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e10 us\/point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e+\/-30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eDifferential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% FS (at 25 deg C), +\/-0.2% FS (0 to 55 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePower = Transformer, Signal = Digital isolator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm min between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e510 VAC for 1 min at 5 mA max leakage current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (12 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSynchronous Backplane Communication \u0026amp; High-Density Processing\u003c\/h3\u003e\n\u003cp\u003eThe module synchronizes current conversions directly with the host controller or network coupler via the internal backplane bus. High backplane bus communication velocity supports deterministic data updates operating in switching synchronous I\/O refreshing or Free-Run refreshing modes. Firmware flash compatibility maintains reliable analog sampling parameters across system expansion updates, facilitating scalable I\/O density scaling while isolating field signals from internal backplane logic.\u003c\/p\u003e\n\u003ch3\u003eShipping Box Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-AD3208 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x Screwless Clamping Terminal Block (12 Terminals)\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Identification Marker\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting Protocols \u0026amp; Field Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlice Alignment\u003c\/strong\u003e: Align the side guide rails of the NX-AD3208 with the adjacent module or coupler, sliding until the backplane bus latch clicks firmly into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Loop Connections\u003c\/strong\u003e: Wire 4 to 20 mA transmitter loops to differential input terminals (+I and -I) using twisted-pair shielded cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Connect the cable shield directly to the functional earth terminal block to mitigate high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring\u003c\/strong\u003e: Insert solid wires or ferruled conductors (AWG 24 to AWG 16) directly into the screwless spring-cage terminals without applying excess tool pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Diagnostic FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat isolation exists between individual analog input channels on this module?\u003c\/p\u003e\n\u003cp\u003eIsolation is provided between the input circuits and the internal NX backplane bus, but no electrical isolation exists between individual channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does switching synchronous I\/O refreshing operate on an EtherCAT network?\u003c\/p\u003e\n\u003cp\u003eInput conversions lock directly to the EtherCAT distributed clock (DC) cycle, allowing cycle-accurate signal sampling at 10 us\/point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if an input signal exceeds the nominal 20 mA limit?\u003c\/p\u003e\n\u003cp\u003eThe channel processes overrange signals within an extended conversion range of -5 to 105% (full scale) before reaching the +\/-30 mA absolute maximum limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module provide power for 2-wire loop transmitters?\u003c\/p\u003e\n\u003cp\u003eNo, the unit operates without internal I\/O power supply terminals; field transmitters require an external 24 VDC loop power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan modules be pulled or inserted while the backplane bus is energized?\u003c\/p\u003e\n\u003cp\u003eNo, removing or hot-swapping the unit under power disrupts the local backplane bus cycle and can trigger controller fault routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire strip length is recommended for the screwless terminal block?\u003c\/p\u003e\n\u003cp\u003eStrip solid copper conductors or stranded wire ferrules to a length of 10 mm prior to insertion into the push-in terminal slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is an analog input open-circuit condition detected?\u003c\/p\u003e\n\u003cp\u003eCurrent values falling below 3.2 mA (-5% FS) trigger an under-range warning flag accessible via controller I\/O mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat status indications are displayed on the front panel?\u003c\/p\u003e\n\u003cp\u003eThe TS (Terminal Status) LED provides status feedback, illuminating green during normal operation and flashing or lighting red during faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306612342957,"sku":"NX-AD3208?","price":154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ad3208_1_2.jpg?v=1790392214"},{"product_id":"omron-cj1w-ad041-v1-analog-input-module-sysmac-cj-series","title":"Omron CJ1W-AD041-V1 Analog Input Module SYSMAC CJ Series","description":"\u003cp\u003eConfigured for high-speed analog signal sampling and process data acquisition in SYSMAC CJ Series systems, the \u003cstrong\u003eOmron CJ1W-AD041-V1\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-AD041-V1\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution across 4 configurable voltage and current input channels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Hardware Model:\u003c\/strong\u003e CJ1W-AD041-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-AD041-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e High-Speed Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Family:\u003c\/strong\u003e Omron SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Classification:\u003c\/strong\u003e Special I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Count:\u003c\/strong\u003e 4 analog inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e 18-point detachable terminal block (M3 screws)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-AD041-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e11.0 cm x 7.0 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e420 mA max at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to +10 V, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Input\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-15 V, Current: +\/-30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage: 1 MOhm min, Current: 250 Ohm (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e4,000 \/ 8,000 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverted Output Data\u003c\/td\u003e\n\u003ctd\u003e16-bit binary data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Period\u003c\/td\u003e\n\u003ctd\u003e1 ms \/ 250 us per point (selectable based on resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation between I\/O and Controller signals (no channel-to-channel isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Real-Time Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-AD041-V1 module interfaced with the CJ Series CPU backplane processes analog signals into 16-bit binary representations within a minimum conversion period of 250 us per point. High backplane transmission rates support dynamic sampling for high-density I\/O configurations while maintaining low cycle overhead. Built-in processing options—including mean value buffer averaging (n = 2 to 64), peak value holding, input disconnection detection, and digital offset\/gain adjustment—run locally on hardware, freeing the host controller for high-speed ladder logic execution. Firmware flash initialization provides automatic hardware register allocation on bus startup.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-AD041-V1 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1x 18-point detachable terminal block with M3 terminal screws\u003c\/li\u003e\n\u003cli\u003e1x Hardware installation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Slide the module onto the guide rails of the CJ Series CPU or expansion rack until the backplane bus connection firmly seats into the backplane socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Wire field instrument signals to the 18-point detachable terminal block using M3 screw connections, ensuring correct polarity for voltage or 4-20 mA current loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Route analog signal cables inside twisted-pair conductors enclosed by continuous 360-deg braid shields bonded to the control panel earth ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding:\u003c\/strong\u003e Connect the CJ Series rack functional earth terminal directly to a single-point copper grounding bar with an impedance measurement under 100 Ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-AD041-V1 on a CJ Series backplane bus?\u003c\/p\u003e\n\u003cp\u003eNo. Main system power must be isolated before removing or installing the module on the backplane to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum current draw on the 5 VDC internal rack bus?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-AD041-V1 draws a maximum current of 420 mA at 5 VDC directly from the internal backplane power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module provide electrical channel-to-channel isolation between inputs?\u003c\/p\u003e\n\u003cp\u003eNo. The module provides photocoupler isolation between the I\/O signals and controller backplane logic, but input channels share a common ground circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat A\/D conversion speeds are supported by the input processing hardware?\u003c\/p\u003e\n\u003cp\u003eThe module features a user-selectable A\/D conversion period of either 1 ms per point or 250 us per point depending on resolution settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the disconnection detection function operate on 4 to 20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eThe module monitors the input level and sets the Disconnection Detection Flag when a signal drops below the threshold (e.g., 1 to 5 V or 4 to 20 mA range loss).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input impedance for current and voltage inputs?\u003c\/p\u003e\n\u003cp\u003eVoltage inputs provide an input impedance of 1 MOhm minimum, while current inputs present a rated input impedance of 250 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding requirement applies to field analog signal lines?\u003c\/p\u003e\n\u003cp\u003eAnalog lines must utilize twisted-pair cabling enclosed in a continuous 360-deg braid shield connected directly to panel earth ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat functional earth ground specification is required for system commissioning?\u003c\/p\u003e\n\u003cp\u003eThe functional earth terminal on the CPU or expansion rack must connect directly to ground bus with resistance under 100 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306613031085,"sku":"CJ1W-AD041-V1","price":281.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-AD041-V1_1.jpg?v=1788102977"},{"product_id":"omron-cj1w-od202-transistor-output-module-sysmac-cj-series","title":"Omron CJ1W-OD202 Transistor Output Module SYSMAC CJ Series","description":"\u003cp\u003eConfigured for high-current discrete switching and field load control in SYSMAC CJ Series systems, the \u003cstrong\u003eOmron CJ1W-OD202\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-OD202\u003c\/strong\u003e Transistor Output Unit) provides direct physical\/electrical execution across 8 sourcing transistor output points.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Hardware Model:\u003c\/strong\u003e CJ1W-OD202\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-OD202\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Transistor Output Module (Sourcing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Family:\u003c\/strong\u003e Omron SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Classification:\u003c\/strong\u003e Basic I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e 8 sourcing outputs (4 points\/common, 2 circuits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-OD202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e11.0 cm x 7.0 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA max at 5 VDC (Internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Load Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e2 A\/point, 8 A\/Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Response Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Response Time\u003c\/td\u003e\n\u003ctd\u003e1.0 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Short-circuit Protection\u003c\/td\u003e\n\u003ctd\u003eDetection current: 6 A min, automatic restart after error clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Disconnection Detection\u003c\/td\u003e\n\u003ctd\u003eDetection current: 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min between external terminals and GR terminal (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC between external terminals and GR terminal for 1 min (10 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 50 mA min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Real-Time Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-OD202 interfaced with the CJ Series CPU backplane maps output bit states directly across the high-speed internal bus, updating physical transistor outputs with maximum execution speeds of 0.5 ms ON and 1.0 ms OFF. Hardware-level short-circuit protection trips at 6 A minimum, automatically restarting output execution following error recovery to maintain high I\/O density scaling and scan determinism. The internal logic circuit draws a low backplane current of 110 mA at 5 VDC, while firmware compatibility allows hardware register assignment across the backplane upon power-up without adding scan delay.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-OD202 Transistor Output Module\u003c\/li\u003e\n\u003cli\u003e1x Terminal block connector kit\u003c\/li\u003e\n\u003cli\u003e1x Hardware specification instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Slide the CJ1W-OD202 unit into the CPU or expansion rack slot until the backplane bus connectors align and latch into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Wire field loads to the sourcing terminals using solid or stranded conductors, ensuring correct 24 VDC external power connection to terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Enclose field wiring in grounded metallic conduits or continuous 360-deg braid shields to isolate 24 VDC load switching from high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Connect the rack Ground (GR) terminal directly to panel earth using copper conductor lines with ground loop resistance under 100 Ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-OD202 on a live SYSMAC CJ backplane?\u003c\/p\u003e\n\u003cp\u003eNo. Main power to the CPU rack assembly must be turned off before inserting or removing the module to avoid hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat internal backplane current is required by the CJ1W-OD202?\u003c\/p\u003e\n\u003cp\u003eThe module consumes a maximum of 110 mA at 5 VDC directly from the internal backplane logic power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power source must be connected to drive the output circuitry?\u003c\/p\u003e\n\u003cp\u003eAn external 24 VDC power supply capable of supplying at least 50 mA at 20.4 to 26.4 VDC is required for output execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the load short-circuit protection function operate?\u003c\/p\u003e\n\u003cp\u003eWhen load current exceeds 6 A minimum, short-circuit protection trips the circuit and automatically restarts operation after the error clears.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the threshold for the line disconnection detection feature?\u003c\/p\u003e\n\u003cp\u003eThe module detects field circuit disconnections when the output load current drops below the 200 mA detection limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat dielectric strength rating is established for the terminal connections?\u003c\/p\u003e\n\u003cp\u003eInsulation withstands 1,000 VAC for 1 minute between external field terminals and the GR terminal at 10 mA maximum leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable load current per individual point and unit?\u003c\/p\u003e\n\u003cp\u003eEach output channel handles up to 2 A maximum, with a total maximum current capacity of 8 A for the entire module unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding resistance standard applies to the GR terminal ground path?\u003c\/p\u003e\n\u003cp\u003eThe GR terminal must be bonded to the central panel earth ground bar maintaining an electrical resistance under 100 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306615980205,"sku":"CJ1W-OD202","price":124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-OD202_1.jpg?v=1788103514"},{"product_id":"nx-da2203-omron-analog-output-unit-nx-series","title":"NX-DA2203 Omron Analog Output Unit NX Series","description":"\u003cp\u003eConfigured for precise analog current loop signal generation in EtherNet\/IP deterministic networks, the \u003cstrong\u003eOmron NX-DA2203\u003c\/strong\u003e (\u003cstrong\u003eNX-DA2203\u003c\/strong\u003e Analog Output Unit) provides direct physical\/electrical execution across NX Series backplane systems.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature \u0026amp; Designators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Slice-type modular remote I\/O platform identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDA\u003c\/strong\u003e: Analog output function category.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Two-channel analog output density configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e203\u003c\/strong\u003e: Current output functional specification variant (4 to 20 mA range).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-DA2203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.1 cm x 1.2 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.85 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent output (4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e600 ohm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 us\/point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Power Supply Method\u003c\/td\u003e\n\u003ctd\u003eSupply from the NX bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm min between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eOptical digital isolation between backplane bus and field circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; I\/O Scaling Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module receives cyclic output data updates across the local NX bus interface. High backplane bus communication velocity enables rapid output updates synchronized with host PLC execution cycles. Firmware flash compatibility ensures seamless integration during system expansions, maintaining uniform output timing during high-density I\/O density scaling across extended fieldbus topologies.\u003c\/p\u003e\n\u003ch3\u003eItems Supplied in Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-DA2203 Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1 x Screwless Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Side Connector Shield Cap\u003c\/li\u003e\n\u003cli\u003e1 x Standard Technical Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring \u0026amp; Mechanical Mounting Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Assembly\u003c\/strong\u003e: Hook the upper latch of the NX-DA2203 onto the 35 mm DIN rail, then swing the lower unit body downward until the backplane locking mechanism clicks securely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring Setup\u003c\/strong\u003e: Connect field actuators to the screwless terminal block using ferruled stranded copper wire (AWG 24 to AWG 16) pressed directly into the clamping terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shield Grounding\u003c\/strong\u003e: Connect two-wire current loop shielded cables to the designated ground bus to prevent electromagnetic noise interference on field signal lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Power Distribution\u003c\/strong\u003e: Verify total current draw on the internal NX power bus does not exceed system power unit limits when feeding I\/O power directly through the backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum external load resistance supported by each analog current output channel?\u003c\/p\u003e\n\u003cp\u003eEach channel supports an allowable load resistance up to 600 ohm max under standard operating voltage conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is internal logic and field output power supplied to the NX-DA2203 module?\u003c\/p\u003e\n\u003cp\u003eAll internal operating and output field power is derived directly via supply from the NX bus backplane rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support hot-swapping while the NX bus remains powered?\u003c\/p\u003e\n\u003cp\u003eNo, replacing the unit under live power disrupts backplane bus communication and requires de-energizing the local segment power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital conversion rate does the module achieve for each output point?\u003c\/p\u003e\n\u003cp\u003eThe conversion time is 250 us\/point for processing internal digital register data into continuous field currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat insulation resistance level is maintained across isolated circuit boundaries?\u003c\/p\u003e\n\u003cp\u003eThe module provides an insulation resistance rating of 20 Mohm min measured between isolated circuits at 100 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan voltage output signals be generated directly from the terminal block of this unit?\u003c\/p\u003e\n\u003cp\u003eNo, the unit is engineered strictly as a current output type module operating within standard milliamp ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat steps prevent backplane communication errors during module insertion?\u003c\/p\u003e\n\u003cp\u003eEnsure side guide pins line up precisely with adjacent modules to avoid bending backplane bus pin contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit react when controller output data updates cease during a network disconnect?\u003c\/p\u003e\n\u003cp\u003eChannels transition to configured fallback states, holding last valid current output or clearing to zero based on software settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306616176813,"sku":"NX-DA2203","price":279.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-da2203-1_3.jpg?v=1790392011"},{"product_id":"omron-cj1w-ad042-analog-input-unit-sysmac-cj-series","title":"Omron CJ1W-AD042 Analog Input Unit SYSMAC CJ Series","description":"\u003cp\u003eConfigured for high-speed multi-range analog signal acquisition in SYSMAC CJ Series platforms, the \u003cstrong\u003eOmron CJ1W-AD042\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-AD042\u003c\/strong\u003e Analog Input Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-AD042\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-AD042\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Unit (4 Channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Classification:\u003c\/strong\u003e CJ-series Special I\/O Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-AD042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 cm x 11.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.60 W (520 mA max. at 5 VDC from PLC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 0 to 10 V, -5 to +5 V, -10 to +10 V, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Input\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-15 V, Current: +\/-30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage: 1 MOhm min., Current: 250 Ohm (rated value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverted Data Format\u003c\/td\u003e\n\u003ctd\u003e16-bit binary data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (25 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-0.2% of F.S., Current: +\/-0.4% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (0 deg C to 55 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-0.4% of F.S., Current: +\/-0.6% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion Period\u003c\/td\u003e\n\u003ctd\u003e20 us\/1 point, 25 us\/2 points, 30 us\/3 points, 35 us\/4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eDigital isolator between I\/O and Controller signals (No channel-to-channel isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Terminals\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Functions\u003c\/td\u003e\n\u003ctd\u003eMean value (n = 2 to 512), Peak value holding, Scaling (+\/-32,000), Input disconnection detection, Direct conversion (AIDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-AD042 delivers high-speed analog signal digitization across the internal backplane bus velocity interface, executing conversions as fast as 20 us for 1 point to 35 us across all 4 points. High-density I\/O density scaling allows rapid register updates directly to the CPU memory mapping. A digital isolator provides galvanic isolation between field inputs and internal controller logic without sacrificing data throughput. Direct conversion using the AIDC instruction is supported on compatible CJ2H-CPU[] (version 1.1 or later) and CJ2M-CPU[][] units, optimizing determinism and maintaining full firmware flash compatibility across CJ-series system architectures.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-AD042 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1x 18-Point Detachable Terminal Block (M3 Screws)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the module into the assigned CJ-series rack position, aligning backplane bus connectors, and secure top\/bottom locking latches to the DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect voltage or current analog input conductors to the 18-point detachable terminal block using standard M3 screw terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Encase analog input lines in twisted-pair cables with 360-deg braid shielding connected to the local panel earth terminal bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a low-impedance copper strap from the host PLC rack functional earth (FE) terminal directly to the enclosure grounding bar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input signal options are available on the CJ1W-AD042 module?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-AD042 supports 1 to 5 V, 0 to 10 V, -5 to +5 V, -10 to +10 V, and 4 to 20 mA analog input ranges across 4 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat conversion speeds does the CJ1W-AD042 achieve per point?\u003c\/p\u003e\n\u003cp\u003eThe A\/D conversion period executes at 20 us for 1 point, 25 us for 2 points, 30 us for 3 points, and 35 us for 4 points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs channel-to-channel isolation available between input loops?\u003c\/p\u003e\n\u003cp\u003eA digital isolator isolates field I\/O from controller signals, but no electrical isolation exists between individual input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum overload values are tolerated on the input terminals?\u003c\/p\u003e\n\u003cp\u003eThe maximum rated continuous input is +\/-15 V for voltage input configurations and +\/-30 mA for current input configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions apply to the CJ1W-AD042 hardware housing?\u003c\/p\u003e\n\u003cp\u003eThe module physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with an overall unit weight of 0.15 kg max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich PLC controllers support the direct conversion AIDC instruction with this unit?\u003c\/p\u003e\n\u003cp\u003eDirect conversion (AIDC) is supported by CJ2H-CPU[] (unit version 1.1+) and CJ2M-CPU[][] CPU Units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat buffer sizes are available for mean value processing calculations?\u003c\/p\u003e\n\u003cp\u003eMean value processing supports buffer sizes (n) of 2, 4, 8, 16, 32, 64, 128, 256, and 512 sample conversions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the current draw of the CJ1W-AD042 from the 5 VDC backplane bus?\u003c\/p\u003e\n\u003cp\u003eThe module consumes up to 520 mA max. at 5 VDC (2.60 W total power consumption) from the system rack backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306616668333,"sku":"CJ1W-AD042","price":249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-AD042_3.jpg?v=1788103432"},{"product_id":"omron-cj1w-scu32-serial-high-speed-communication-unit-sysmac-cj-series","title":"Omron CJ1W-SCU32 Serial High-Speed Communication Unit SYSMAC CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-SCU32\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-SCU32\u003c\/strong\u003e Serial High-Speed Communication Unit, operates as a dedicated hardware component for multi-protocol serial communication execution within SYSMAC CJ Series platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Hardware Model:\u003c\/strong\u003e CJ1W-SCU32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-SCU32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Serial High-Speed Communication Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Family:\u003c\/strong\u003e Omron SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Classification:\u003c\/strong\u003e CPU Bus Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Bus Architecture:\u003c\/strong\u003e CJ I\/O Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Port Count:\u003c\/strong\u003e 2 independent serial ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-SCU32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.19 cm x 3.10 cm x 9.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.00 cm x 7.50 cm x 13.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e280 mA max at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2 ports (MODBUS Master, MODBUS Slave, RS-422\/485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Baud Rate\u003c\/td\u003e\n\u003ctd\u003e230 kBit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Protocols\u003c\/td\u003e\n\u003ctd\u003eProtocol Macro, Modbus-RTU, Serial Gateway, No-protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Real-Time Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-SCU32 operates as a CJ CPU Bus Unit, routing high-speed serial data blocks across the internal CJ I\/O Bus interface directly into CPU memory. The dual serial channels execute Modbus Master\/Slave commands and custom protocol macros independently of CPU cyclic ladder scans. Data throughput reaches speeds up to 230 kBit\/s per port, maintaining communication determinism during heavy data exchange phases. Onboard flash memory maintains protocol execution tables and unit parameters across power cycles without requiring external backup battery power.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-SCU32 Serial High-Speed Communication Unit\u003c\/li\u003e\n\u003cli\u003e2x Serial port connector hardware shells\u003c\/li\u003e\n\u003cli\u003e1x Technical instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Assembly:\u003c\/strong\u003e Slide the CJ1W-SCU32 onto the CJ Series CPU or expansion base rack until the backplane bus pins fully engage into the adjacent backplane socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Wiring:\u003c\/strong\u003e Terminate RS-422\/485 communication lines using twisted-pair cables, ensuring correct signal line polarities (A\/B) across all networked nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Terminate the outer braided cable shield 360 degrees to the metallic connector housing and connect it to panel earth ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding:\u003c\/strong\u003e Connect the CPU power supply functional earth terminal to the main panel grounding bus with an electrical resistance under 100 Ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for the CJ1W-SCU32 on the CJ I\/O bus?\u003c\/p\u003e\n\u003cp\u003eNo. Internal system power must be isolated before inserting or removing the unit from the backplane rack assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum current does the unit draw from the 5 VDC internal power rail?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-SCU32 draws a maximum current consumption of 280 mA at 5 VDC from the backplane supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum baud rate is supported across the serial communication ports?\u003c\/p\u003e\n\u003cp\u003eBoth communication channels support data transmission rates up to a maximum limit of 230 kBit\/s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat serial protocols can be executed natively on the CJ1W-SCU32?\u003c\/p\u003e\n\u003cp\u003eThe module natively executes Modbus-RTU Master\/Slave, Protocol Macro, Serial Gateway, and No-protocol ASCII formats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat interface standard is utilized for physical port wiring?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates 2 serial ports utilizing the RS-422\/485 differential physical signal standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit preserve protocol configuration settings during power loss?\u003c\/p\u003e\n\u003cp\u003eConfiguration tables and user protocol macros are stored in non-volatile onboard flash memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding procedure must be implemented for RS-422 signal lines?\u003c\/p\u003e\n\u003cp\u003eSignal lines require continuous 360-deg braid shielding bonded directly to the enclosure protective earth ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat functional earth ground resistance boundary applies to the rack installation?\u003c\/p\u003e\n\u003cp\u003eThe central earth ground connection must maintain a ground loop resistance strictly under 100 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306617192621,"sku":"CJ1W-SCU32","price":127.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-SCU32_1.jpg?v=1788103339"},{"product_id":"omron-cj1w-ad081-v1-analog-input-unit-sysmac-cj-series","title":"Omron CJ1W-AD081-V1 Analog Input Unit SYSMAC CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-AD081-V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-AD081-V1\u003c\/strong\u003e Analog Input Unit, operates as a dedicated hardware component for multi-channel analog signal acquisition within SYSMAC CJ Series platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-AD081-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-AD081-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Input Unit (8 Inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Classification:\u003c\/strong\u003e CJ-series Special I\/O Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-AD081-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 cm x 11.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.10 W (0.42 A at 5 VDC from PLC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range Selection\u003c\/td\u003e\n\u003ctd\u003eSet separately for each input channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/4,000 (Settable to 1\/8,000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Period\u003c\/td\u003e\n\u003ctd\u003e1 ms\/point (250 us\/point option depending on resolution setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\/Speed Dependency\u003c\/td\u003e\n\u003ctd\u003eLinked mode (1\/4,000 mode defaults to 1 ms\/point conversion speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (25 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +\/-0.2% of F.S., Current: +\/-0.4% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Number Allocation\u003c\/td\u003e\n\u003ctd\u003e1 unit number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-AD081-V1 converts incoming physical signals into digital registers transferred across the internal backplane bus velocity pipeline to the CPU memory mapping. High-density I\/O density scaling integrates 8 discrete analog channels into a single-slot footprint while allocating 1 Special I\/O Unit number. Resolution modes of 1\/4,000 and 1\/8,000 correlate directly with conversion periods of 1 ms\/point and 250 us\/point, maintaining Profinet\/EtherNet\/IP determinism across wider network architectures and preserving firmware flash compatibility across all SYSMAC CJ PLC racks.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-AD081-V1 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable Terminal Block Assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module onto the CJ-series backplane rack, aligning the bus connector pins, and secure top and bottom DIN-rail locking tabs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field sensor lines directly to the removable terminal block terminals, configuring jumper wiring per channel for current vs. voltage operational modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Enclose low-level signal lines inside twisted-pair conductors using 360-deg braid shielding anchored to the local enclosure grounding bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect a direct copper grounding braid from the PLC rack functional earth (FE) terminal to the central enclosure earth grid.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input signal ranges can be configured on the CJ1W-AD081-V1?\u003c\/p\u003e\n\u003cp\u003eThe module supports 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA ranges, which can be selected separately per input channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are resolution settings tied to conversion speed on this module?\u003c\/p\u003e\n\u003cp\u003eResolution and speed cannot be set independently; selecting a 1\/4,000 resolution configuration locks the conversion period to 1 ms\/point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current consumption is drawn from the 5 VDC system backplane?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-AD081-V1 draws 0.42 A at 5 VDC (2.10 W total power consumption) directly from the PLC backplane power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many Unit Numbers are consumed by the CJ1W-AD081-V1 on the CPU rack?\u003c\/p\u003e\n\u003cp\u003eThe module allocates exactly 1 Special I\/O Unit number within the PLC CPU memory allocation map.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions apply to the CJ1W-AD081-V1 hardware casing?\u003c\/p\u003e\n\u003cp\u003eThe physical dimensions of the module housing measure 3.1 cm x 9.0 cm x 6.5 cm with a net weight of 0.14 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-AD081-V1 module?\u003c\/p\u003e\n\u003cp\u003eNo, power to the CJ-series rack must be switched OFF prior to removing or inserting the module into the backplane bus slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the conversion speed when configured for 250 us per point?\u003c\/p\u003e\n\u003cp\u003eSetting the module to high-speed mode yields a 250 us\/point conversion period corresponding to the high-resolution setting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat field connection hardware is integrated into the front interface?\u003c\/p\u003e\n\u003cp\u003eThe module utilizes a removable terminal block to allow pre-wiring and rapid field unit replacement without disconnecting individual conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306617847981,"sku":"CJ1W-AD081-V1","price":217.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-AD081-V1_3.jpg?v=1788103239"},{"product_id":"omron-cj1w-da08c-analog-output-module-sysmac-cj-series","title":"Omron CJ1W-DA08C Analog Output Module SYSMAC CJ Series","description":"\u003cp\u003eConfigured for multi-channel analog signal generation in SYSMAC CJ Series platforms, the \u003cstrong\u003eOmron CJ1W-DA08C\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-DA08C\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-DA08C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-DA08C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Output Module (8 Channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Classification:\u003c\/strong\u003e CJ-series Special I\/O Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-DA08C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 cm x 11.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.70 W (140 mA max. at 5 VDC from PLC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 170 mA max. (Inrush: 20 A max., pulse width: 1 ms min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e8 current output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Resistance\u003c\/td\u003e\n\u003ctd\u003e350 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e4,000 \/ 8,000 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Conversion Period\u003c\/td\u003e\n\u003ctd\u003e1.0 ms or 250 us per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% of F.S. at 25 deg C, +\/-0.6% of F.S. at 0 deg C ... 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation between I\/O and Controller (No channel-to-channel isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Terminals\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Functions\u003c\/td\u003e\n\u003ctd\u003eOutput hold (CLR\/HOLD\/MAX), scaling, offset\/gain adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-DA08C converts 16-bit binary register data sent via the internal backplane bus velocity framework into 8 channels of 4 to 20 mA analog output current loops. Utilizing photocoupler galvanic isolation between field terminal loops and internal CPU backplane logic, the module prevents noise transfer to the PLC processor without compromising transfer determinism. High-density I\/O density scaling allows 8 independent current loops per slot, executing D\/A conversions at selectable rates of 1.0 ms or 250 us per channel while updating registers directly in CPU Special I\/O Unit memory allocations.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-DA08C Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1x 18-Point Detachable Terminal Block (M3 Screws)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap the module into an assigned slot on the CJ1 CPU or expansion rack and lock the top and bottom slider latches securely to the DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect 4 to 20 mA field loop conductors to the 18-point removable terminal block, tightening M3 terminal screws to specified torque ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Wire analog current signals using twisted-pair cables with 360-deg braid shielding bonded to the enclosure functional earth bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the main PLC rack functional earth (FE) terminal to the panel central ground bar using a low-impedance copper grounding strap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal ranges are supported by the CJ1W-DA08C?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-DA08C supports an analog output signal current range of 4 to 20 mA across all 8 output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs channel-to-channel isolation provided on the CJ1W-DA08C module?\u003c\/p\u003e\n\u003cp\u003ePhotocoupler isolation is provided between I\/O signals and the controller, but there is no channel-to-channel isolation between individual I\/O loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power supply source is required to drive the output loops?\u003c\/p\u003e\n\u003cp\u003eThe module requires an external 24 VDC power supply rated at 170 mA max. with an inrush current capacity of 20 A max. (1 ms min. pulse).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions apply to the CJ1W-DA08C hardware?\u003c\/p\u003e\n\u003cp\u003eThe module physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with a net unit weight of 0.15 kg max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum load resistance can be driven on each current loop channel?\u003c\/p\u003e\n\u003cp\u003eEach 4 to 20 mA analog output channel supports a maximum permissible load resistance of 350 Ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the selectable D\/A conversion speeds per channel on this unit?\u003c\/p\u003e\n\u003cp\u003eThe D\/A conversion period can be set to either 1.0 ms or 250 us per point depending on system configuration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the output hold function behave during CPU controller stop errors?\u003c\/p\u003e\n\u003cp\u003eThe output hold function maintains analog channels at a designated output status (CLR, HOLD, or MAX) when controller execution stops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal block connection type is integrated on the module front panel?\u003c\/p\u003e\n\u003cp\u003eField wiring connects via an 18-point detachable terminal block secured with standard M3 screw terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306620043437,"sku":"CJ1W-DA08C","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-DA08C_2.jpg?v=1788154789"},{"product_id":"omron-cj1w-id233-dc-input-module-sysmac-cj-series","title":"Omron CJ1W-ID233 DC Input Module SYSMAC CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-ID233\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-ID233\u003c\/strong\u003e DC Input Unit, operates as a dedicated hardware component for 24 VDC discrete signal acquiring and field status evaluation within SYSMAC CJ Series platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Hardware Model:\u003c\/strong\u003e CJ1W-ID233\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-ID233\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC Input Module (32 Points)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Family:\u003c\/strong\u003e Omron SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Classification:\u003c\/strong\u003e Basic I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Interface:\u003c\/strong\u003e MIL Connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Circuitry:\u003c\/strong\u003e 32 points (16 points\/common, 2 circuits)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.10 cm x 6.50 cm x 9.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e11.00 cm x 7.00 cm x 13.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA max at 5 VDC (Internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e5.6 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA typical (at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage \/ ON Current\u003c\/td\u003e\n\u003ctd\u003e19.0 VDC min \/ 3 mA min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Voltage \/ OFF Current\u003c\/td\u003e\n\u003ctd\u003e5 VDC max \/ 1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (ON \/ OFF)\u003c\/td\u003e\n\u003ctd\u003e8.0 ms max (configurable 0 to 32 ms in Setup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneous ON Ratio\u003c\/td\u003e\n\u003ctd\u003e75% (12 points\/common) simultaneously ON at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min between external terminals and GR terminal (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC between external terminals and GR terminal for 1 minute (10 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Real-Time Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-ID233 interfaces directly with the CJ Series CPU backplane to process high-density 32-point input data matrices across the high-speed internal bus structure. Hardware-level input filtering allows customizable response delays adjustable from 0 to 32 ms via system parameters, optimizing backplane bus velocity and logic scan determinism. Memory assignment and firmware synchronization occur automatically upon backplane initialization, ensuring stable register updates to the CPU rack without introducing logic timing jitter.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-ID233 DC Input Module\u003c\/li\u003e\n\u003cli\u003e1x Hardware specification instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Align the unit's backplane pins with the adjacent CPU or expansion rack slot, pressing firmly until the top and bottom locking levers click into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Wiring:\u003c\/strong\u003e Attach pre-assembled MIL connector cables to the dual 16-point interface headers, securing physical latching arms to prevent loose contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Terminate outer braid shielding of input signal cabling 360 degrees to the enclosure grounding bar near the cable entry point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Connect the rack Ground (GR) terminal to the primary panel earth ground bus using heavy-gauge copper wire with a loop resistance under 100 Ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-ID233 module on a live CJ backplane?\u003c\/p\u003e\n\u003cp\u003eNo. Internal system supply power must be isolated prior to removing or installing the module to avoid hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the internal backplane current draw of the CJ1W-ID233?\u003c\/p\u003e\n\u003cp\u003eThe module consumes a maximum current of 200 mA at 5 VDC directly from the internal backplane logic bus rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the threshold parameters for detecting an ON state?\u003c\/p\u003e\n\u003cp\u003eAn input channel evaluates as ON when field voltage reaches a minimum of 19.0 VDC and current reaches at least 3 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan input response times be modified from the factory default setting?\u003c\/p\u003e\n\u003cp\u003eYes. The ON and OFF response delays can be configured between 0 and 32 ms using system software settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the limit for simultaneously ON inputs per common circuit?\u003c\/p\u003e\n\u003cp\u003eUp to 75% of channels (12 points out of 16 per common) can be ON simultaneously at 24 VDC operating voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are field input wires physically connected to the CJ1W-ID233?\u003c\/p\u003e\n\u003cp\u003eField signal conductors connect through integrated dual MIL connector headers on the front interface panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat dielectric strength rating applies between the field terminals and ground?\u003c\/p\u003e\n\u003cp\u003eThe channel isolation withstands 1,000 VAC applied between external terminals and the GR terminal for 1 minute.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding resistance requirement must be maintained for the rack GR terminal?\u003c\/p\u003e\n\u003cp\u003eThe GR terminal connection path to the protective panel earth bar must maintain an electrical resistance under 100 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306624893101,"sku":"CJ1W-ID233","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-ID233_3.jpg?v=1788103806"},{"product_id":"cj1w-nc433-omron-cj1-series-position-control-unit","title":"CJ1W-NC433 Omron CJ1 Series Position Control Unit","description":"\u003cp\u003eConfigured for multi-axis motion profile generation and line-driver pulse outputs in Omron automation racks, the \u003cstrong\u003eOmron CJ1W-NC433\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-NC433\u003c\/strong\u003e Position Control Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Number Decoding \u0026amp; Structure\u003c\/h3\u003e\n\u003cp\u003eThe functional designation identifies key motion control capabilities within the CJ1 platform:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJ1W\u003c\/strong\u003e: Dedicated expansion module classification for CJ-series controller backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNC\u003c\/strong\u003e: Specialized position control module group supporting pulse-train output command generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: System control capacity configured for 4 independent motion axes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e33\u003c\/strong\u003e: High-speed line-driver output interface for noise-immune pulse command transmission.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Performance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-NC433\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.8 cm x 11.0 cm x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.80 W (0.36 A at 5 VDC backplane supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eOpen-loop control by pulse train output \/ Line-driver output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Control Axes\u003c\/td\u003e\n\u003ctd\u003e4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Number Allocation\u003c\/td\u003e\n\u003ctd\u003eOccupies 2 unit numbers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectives \/ Standards\u003c\/td\u003e\n\u003ctd\u003eUC1, CE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Type\u003c\/td\u003e\n\u003ctd\u003eCJ1 Special I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communications \u0026amp; Motion Bus Acceleration\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes dedicated internal logic pipelines to maintain high backplane bus communication velocity during multi-axis path generation. Direct dual-port memory mapping allows high-speed transfer of target positions, acceleration\/deceleration profiles, and status flags to the CPU backplane without scan jitter. Native firmware flash compatibility across standard CJ-series processing units ensures reliable memory synchronization across all 4 control axes.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery \u0026amp; Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-NC433 Position Control Unit\u003c\/li\u003e\n\u003cli\u003e2 x Connector protective dust caps\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Assembly \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion\u003c\/strong\u003e: Slide the module into the CJ rack until upper and lower locking levers click firmly to verify complete backplane connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Driver Shielding\u003c\/strong\u003e: Connect twisted-pair line-driver cables to the drive interface using shielded lines to prevent pulse signal corruption from high-voltage EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Number Addressing\u003c\/strong\u003e: Set the front-panel rotary switches to an unused pair of unit numbers before applying system power to avoid bus address conflicts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Standards\u003c\/strong\u003e: Bond the rack mounting rail to panel ground using a braided copper wire (minimum 2 mm sq cross-section) to maintain common-mode noise suppression.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat current level does the module draw from the internal 5 VDC backplane bus?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-NC433 draws 0.36 A at 5 VDC from the rack backplane power supply, requiring appropriate total rack load calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many unit numbers are allocated to this motion controller?\u003c\/p\u003e\n\u003cp\u003eThe unit allocates 2 sequential unit numbers in the Special I\/O Unit memory map to handle control data for all 4 axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal format does the CJ1W-NC433 use for drive commands?\u003c\/p\u003e\n\u003cp\u003eThe module generates open-loop pulse train command signals utilizing differential line-driver outputs for high noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for this special I\/O unit during rack operation?\u003c\/p\u003e\n\u003cp\u003eNo, power to the rack assembly must be completely de-energized prior to inserting or extracting the unit from the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power source is required for line-driver circuit operation?\u003c\/p\u003e\n\u003cp\u003eExternal 24 VDC power must be wired to the module interface terminals to power internal optocoupler and line-driver output stages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat standards compliance ratings does this unit carry?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-NC433 complies with standard CE marking directives and UC1 (UL Class 1 Division 2) safety standards for industrial installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit isolate pulse output channels from backplane logic?\u003c\/p\u003e\n\u003cp\u003eInternal optical isolators provide full galvanic isolation between the core 5 VDC backplane bus and the external line-driver field terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the position control unit execute independent axis movements simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware onboard processor manages independent positioning, speed control, and interrupt feeding across all 4 axes concurrently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306628726957,"sku":"CJ1W-NC433","price":102.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-NC433_1.jpg?v=1788159580"},{"product_id":"omron-cj1w-scu31-v1-serial-communications-unit-cj-series","title":"Omron CJ1W-SCU31-V1 Serial Communications Unit CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-SCU31-V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-SCU31-V1\u003c\/strong\u003e Serial Communications Unit, operates as a dedicated hardware component for multi-protocol serial communication execution within Omron CJ-series PLC networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Part Number:\u003c\/strong\u003e CJ1W-SCU31-V1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClassification:\u003c\/strong\u003e CPU Bus Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision Identifier:\u003c\/strong\u003e Unit Ver. 1.2 \/ Unit Ver. 1.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e Port 1 (RS-422A\/485), Port 2 (RS-422A\/485)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-SCU31-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg Max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 6.5 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 10.0 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.90 W (380 mA at 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e380 mA Max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 1 Interface\u003c\/td\u003e\n\u003ctd\u003eRS-422A\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 2 Interface\u003c\/td\u003e\n\u003ctd\u003eRS-422A\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 1 Protocols\u003c\/td\u003e\n\u003ctd\u003eHost Link, Protocol Macro, NT Link, Loopback Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort 2 Protocols\u003c\/td\u003e\n\u003ctd\u003eHost Link, Protocol Macro, NT Link, Loopback Test, Serial Gateway, No-protocol, 1:1 Host Link, Modbus-RTU Slave (Ver. 1.3+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMountable Units Count\u003c\/td\u003e\n\u003ctd\u003eUp to 16 Units per CPU Rack \/ Expansion Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIO Area Allocation\u003c\/td\u003e\n\u003ctd\u003e25 words (software switches and status refresh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDM Area Allocation\u003c\/td\u003e\n\u003ctd\u003e20 words total (10 words per serial port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimple Backup Function\u003c\/td\u003e\n\u003ctd\u003eCompatible with CJ1-H and CJ1M CPU Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-SCU31-V1\u003c\/strong\u003e interfaces directly with the CJ-series high-speed backplane bus, operating as a CPU Bus Unit to achieve cyclic data exchange across 25 allocated CIO words and 20 DM words. CPU refresh timing transfers status flags and software switches constantly without interrupting ladder execution cycles. Runtime configuration shifts are executed via the ladder instruction STUP (237) or by triggering the Port Settings Changing Flag in the Auxiliary Area.\u003c\/p\u003e\n\u003cp\u003eFirmware revisions expand interface routing capability without hardware retrofits. Unit Version 1.2 introduces the integrated Serial Gateway engine, which automatically converts incoming FINS commands over the backplane bus into serial protocol frames (including protocol macro execution). Unit Version 1.3 adds native Modbus-RTU slave mode to Port 2, enabling direct connectivity to standard industrial master devices without custom ladder frame parsing.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-SCU31-V1 Serial Communications Unit\u003c\/li\u003e\n\u003cli\u003e2x Terminal Block Connectors (RS-422A\/485)\u003c\/li\u003e\n\u003cli\u003e1x Hardware Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Secure the module onto the CJ-series CPU Rack or Expansion Rack DIN rail until the upper and lower locking mechanisms engage. No slot location restrictions apply within the 16-unit total CPU Bus Unit allocation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-422A\/485 Wiring:\u003c\/strong\u003e Utilize twisted-pair shielded cable for differential signaling on Port 1 and Port 2. Maintain uniform polarity across all network nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect cable shielding to the functional ground (FG) terminal using a 360-deg braid clamp at a single grounding node to suppress high-frequency electro-magnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Enable the built-in terminating resistance via the DIP switch on the front panel for units positioned at the physical ends of an RS-422A\/485 transmission line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum backplane current draw for the CJ1W-SCU31-V1?\u003c\/p\u003e\n\u003cp\u003eThe unit draws a maximum current of 380 mA at 5 VDC directly from the CJ-series CPU backplane bus power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many CJ1W-SCU31-V1 units can be installed on a single CPU Rack?\u003c\/p\u003e\n\u003cp\u003eUp to 16 CPU Bus Units, including all CJ1W-SCU31-V1 modules, can be mounted on a single CPU Rack or Expansion Rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich instruction forces a reload of the serial port setting words from the DM area?\u003c\/p\u003e\n\u003cp\u003eExecuting the ladder instruction STUP (237) forces an immediate reload of the 10 DM configuration words allocated to each serial port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-SCU31-V1 module on a CJ-series rack?\u003c\/p\u003e\n\u003cp\u003eNo, power to the CPU Rack and Expansion Racks must be completely turned OFF before inserting or removing the CJ1W-SCU31-V1 unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-SCU31-V1 support Modbus-RTU slave mode on both ports?\u003c\/p\u003e\n\u003cp\u003eModbus-RTU slave mode is supported on Port 2 only, requiring Unit Version 1.3 or later firmware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the Simple Backup Function interact with the CJ1W-SCU31-V1 protocol macro data?\u003c\/p\u003e\n\u003cp\u003eThe Simple Backup Function backs up internal Protocol Macro data to a Memory Card installed in CJ1-H or CJ1M CPU Units for restoration or comparison.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat memory areas are allocated to the CJ1W-SCU31-V1 in the CPU Unit?\u003c\/p\u003e\n\u003cp\u003eThe module receives 25 words in the CPU Bus Unit CIO Area and 20 words in the CPU Bus Unit DM Area (10 words per port).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding practice is required for long-distance RS-485 serial runs?\u003c\/p\u003e\n\u003cp\u003eField cabling requires 360-deg braid shielding connected to a low-impedance protective earth terminal to eliminate ground potential loops and signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306629808301,"sku":"CJ1W-SCU31-V1","price":173.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-SCU31-V1_2.jpg?v=1788157066"},{"product_id":"omron-cj1w-da08v-analog-output-unit-cj-series","title":"Omron CJ1W-DA08V Analog Output Unit CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-DA08V\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-DA08V\u003c\/strong\u003e Analog Output Unit, operates as a dedicated hardware component for multi-channel digital-to-analog voltage conversion within Omron CJ-series PLC systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Part Number:\u003c\/strong\u003e CJ1W-DA08V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClassification:\u003c\/strong\u003e Special I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllocated Unit Numbers:\u003c\/strong\u003e 1 unit number allocated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channel Count:\u003c\/strong\u003e 8 High-Density Voltage Outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-DA08V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 10.0 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.06 W (0.14 A at 5 VDC + 0.14 A at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 0.14 A (internal backplane), 24 VDC: 0.14 A max (external power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC +10% -15%, 140 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e8 voltage outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range Selection\u003c\/td\u003e\n\u003ctd\u003eSet separately for each output channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u0026amp; Speed Modes\u003c\/td\u003e\n\u003ctd\u003eStandard Mode: 1\/4,000 resolution at 1 ms\/point; High-Resolution Mode: 1\/8,000 resolution at 250 us\/point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% of Full Scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Velocity \u0026amp; High-Density Signal Scaling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-DA08V\u003c\/strong\u003e interfaces directly with the high-speed CJ-series backplane bus, driving 8 independent analog voltage output channels within a single slot footprint. Operating as a Special I\/O Unit, the module routes internal digital register words to high-precision D\/A converters, maintaining strict timing execution across all assigned output points.\u003c\/p\u003e\n\u003cp\u003eChannel resolution and conversion timing operate under a coupled dependency architecture: standard 1\/4,000 resolution updates at 1 ms per point, while high-resolution mode provides 1\/8,000 resolution at 250 us per point. Signal ranges (1 to 5 V, 0 to 5 V, 0 to 10 V, and -10 to 10 V) are configured independently per channel via CPU Special I\/O Unit memory allocations. Internal firmware flash compatibility ensures zero backplane bus latency during high-density cyclic data refreshes.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-DA08V Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1x Hardware Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Slide the CJ1W-DA08V onto the CJ-series CPU Rack or Expansion Rack DIN rail until top and bottom locking levers click firmly into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Number Allocation:\u003c\/strong\u003e Set the front-panel rotary unit number switch (0 to 95) prior to system energization to assign dedicated memory addresses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Field Wiring:\u003c\/strong\u003e Connect an external 24 VDC (+10% -15%) auxiliary power source to the designated terminal block pins. Route individual voltage output signals using twisted-pair shielded cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Terminate cable braid shields to the functional earth (FE) terminal block connection. Secure a dedicated 2.0 mm sq or larger copper ground wire from the PLC rack ground terminal to protective earth using a 360-deg braid clamp.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the 5 VDC backplane current consumption of the CJ1W-DA08V?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-DA08V draws 0.14 A at 5 VDC directly from the internal CJ-series CPU backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the external power supply requirements for the module?\u003c\/p\u003e\n\u003cp\u003eThe unit requires an external auxiliary supply of 24 VDC (+10% -15%) rated at 140 mA maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan output resolution and conversion speed be configured independently?\u003c\/p\u003e\n\u003cp\u003eNo, setting 1\/4,000 resolution forces a 1 ms\/point speed, while 1\/8,000 resolution forces a 250 us\/point conversion speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre individual output signal ranges configurable per channel?\u003c\/p\u003e\n\u003cp\u003eYes, each of the 8 output channels can be assigned separate voltage ranges (1-5 V, 0-5 V, 0-10 V, -10 to 10 V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-DA08V support hot-swapping while the rack is powered?\u003c\/p\u003e\n\u003cp\u003eNo, input power to the CPU Rack or Expansion Rack must be disconnected before installing or removing the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many Special I\/O Unit numbers does the CJ1W-DA08V occupy?\u003c\/p\u003e\n\u003cp\u003eThe module allocates exactly 1 Special I\/O Unit number in the CPU memory map.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat field termination hardware is supplied with the unit?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-DA08V features an 18-point removable terminal block for all field output signals and external 24 VDC power connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the overall signal conversion accuracy at room temperature?\u003c\/p\u003e\n\u003cp\u003eThe conversion accuracy is +\/-0.3% of Full Scale (F.S.) at an ambient temperature of 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306634657965,"sku":"CJ1W-DA08V","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-DA08V_2.jpg?v=1788155713"},{"product_id":"nx-cif105-omron-communications-interface-units-nx-series","title":"NX-CIF105 Omron Communications Interface Units NX-series","description":"\u003cp\u003eConfigured for serial data transmission over RS-422A and RS-485 physical loops, the \u003cstrong\u003eOmron NX-CIF105\u003c\/strong\u003e (\u003cstrong\u003eNX-CIF105\u003c\/strong\u003e Communications Interface Units) provides direct physical and electrical execution across distributed industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature \u0026amp; Architecture Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model designation defines structural channel capacity, serial physical layers, and communication protocol handling within the Omron NX modular product line.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for high-speed backplane bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCIF\u003c\/strong\u003e: Dedicated communication interface module classification handling serial data transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e105\u003c\/strong\u003e: Single-port RS-422A\/485 serial communication configuration supporting half-duplex and full-duplex wiring modes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-CIF105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15 cm x 10 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.65 W max. (Connected to CPU Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Ports\u003c\/td\u003e\n\u003ctd\u003e1 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Ports\u003c\/td\u003e\n\u003ctd\u003eRS-422A\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Protocol\u003c\/td\u003e\n\u003ctd\u003eNo-protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Communications Distance\u003c\/td\u003e\n\u003ctd\u003e1200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePDO Data Size\u003c\/td\u003e\n\u003ctd\u003e4 to 80 bytes (selectable increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly with the central processing backplane via high-speed communication channels, supporting deterministic network topologies. Firmware flash compatibility ensures seamless system updates without interrupting active serial buffers. Furthermore, backplane bus communication velocity guarantees rapid data transfer to the controller CPU, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing transmission throughput.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-CIF105 Communications Interface Unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable screwless terminal connector block\u003c\/li\u003e\n\u003cli\u003e1 x Hardware safety and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting\n\u003cul\u003e\n\u003cli\u003eSecure the unit onto a standard 35 mm DIN rail inside a protective metallic enclosure designed for industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSerial Line Cabling\n\u003cul\u003e\n\u003cli\u003eRoute twisted-pair shielded cables for RS-422A\/485 connections up to 1200 m max distance while maintaining proper termination resistors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal Connection\n\u003cul\u003e\n\u003cli\u003eInsert stripped conductor wires directly into the screwless clamping terminals without utilizing screw-tightening tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eShield Grounding\n\u003cul\u003e\n\u003cli\u003eTerminate cable shields to the cabinet functional earth busbar to prevent electromagnetic interference along long serial runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Operation Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat serial communication standards are supported by the NX-CIF105 module?\u003c\/p\u003e\n\u003cp\u003eThe unit supports RS-422A and RS-485 physical layer interfaces for multi-drop serial communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable communication distance for serial loops?\u003c\/p\u003e\n\u003cp\u003eThe hardware permits cable runs up to 1200 m maximum under standard industrial wiring practices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich communication protocols can be executed on the port?\u003c\/p\u003e\n\u003cp\u003eThe module operates using No-protocol mode for transparent ASCII or binary frame transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit handle half-duplex and full-duplex wiring?\u003c\/p\u003e\n\u003cp\u003eIt supports half duplex for two-wire connections and full duplex for four-wire connection layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the selectable Process Data Object (PDO) size range?\u003c\/p\u003e\n\u003cp\u003ePDO data size can be configured from 4 up to 80 bytes for inputs or outputs in incremental steps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are internal circuits isolated from external serial lines?\u003c\/p\u003e\n\u003cp\u003ePower supply isolation uses transformers and photocouplers, while signals use digital isolators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the interface unit support data backup functions?\u003c\/p\u003e\n\u003cp\u003eYes, integrated functions to back up configuration and communication data are fully provided.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum power consumption when connected to a CPU unit?\u003c\/p\u003e\n\u003cp\u003ePower consumption reaches up to 1.65 W maximum when attached directly to a CPU unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306634854573,"sku":"NX-CIF105","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-cif105.jpg?v=1791554916"},{"product_id":"omron-cj1w-od234-transistor-output-unit-sysmac-cj1-series","title":"Omron CJ1W-OD234 Transistor Output Unit SYSMAC CJ1 Series","description":"\u003cp\u003eConfigured for high-density discrete load switching in SYSMAC CJ1 Series platforms, the \u003cstrong\u003eOmron CJ1W-OD234\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-OD234\u003c\/strong\u003e Transistor Output Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-OD234\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-OD234\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e SYSMAC CJ1 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Transistor Output Unit (32 Points, Sinking)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost System:\u003c\/strong\u003e SYSMAC CJ1 Series PLC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-OD234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 11.0 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.1 W (220 mA at 5 VDC from PLC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Load Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\/point, 2 A\/common, 4 A\/Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e4.0 A\/point, 10 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e32 points (Sinking outputs, MIL connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e32 (16 points\/common, 2 circuits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON\/OFF Response Time\u003c\/td\u003e\n\u003ctd\u003eON: 15 us max., OFF: 80 us max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage \/ Residual Voltage\u003c\/td\u003e\n\u003ctd\u003eLeakage: 0.1 mA max., Residual: 1.5 V max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC, 110 mA min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. between external terminals and GR (100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC between external terminals and GR for 1 min (leakage 10 mA max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Protection\u003c\/td\u003e\n\u003ctd\u003eNone (no internal fuses)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-OD234 interface operates across the internal backplane bus velocity framework of the SYSMAC CJ1 chassis to deliver rapid bit-state transfers from CPU memory to field actuators. Solid-state output driver arrays execute switching cycles with high-speed response parameters (ON time of 15 us max., OFF time of 80 us max.), supporting high-density I\/O density scaling across a dual 16-point common layout. The module isolates internal 5 VDC logic processing from external 24 VDC load loops, maintaining deterministic update execution without inducing voltage noise or backplane processor latency.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-OD234 Transistor Output Unit\u003c\/li\u003e\n\u003cli\u003e1x MIL Connector Cover Shell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the unit into the assigned slot on the CJ1 CPU or expansion rack and slide the upper and lower locking levers until locked to the DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring using compatible 40-pin MIL connector wiring harnesses, connecting sinking load return lines to negative common rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Route external 24 VDC power and discrete output wiring through grounded metal conduit isolated from high-voltage AC conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the PLC rack functional earth (FE) rail and enclosure ground bus to system earth via a low-impedance copper strap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output switching logic type is utilized by the CJ1W-OD234?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-OD234 utilizes NPN sinking output logic across 32 points organized into 2 isolated circuits of 16 points per common.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the maximum continuous load current limits for the module?\u003c\/p\u003e\n\u003cp\u003eCurrent output limits are 0.5 A per point, 2 A per common group, and 4 A maximum for the entire output unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-OD234 contain internal fuse protection for output points?\u003c\/p\u003e\n\u003cp\u003eNo, the CJ1W-OD234 does not contain internal fuses; external short-circuit protection devices must be installed on field wiring loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the external power supply requirement for driver operation?\u003c\/p\u003e\n\u003cp\u003eAn external supply operating from 20.4 to 26.4 VDC with a minimum current rating of 110 mA is required for output drive circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions apply to the CJ1W-OD234 hardware?\u003c\/p\u003e\n\u003cp\u003eThe module physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with a maximum module weight of 0.07 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical ON and OFF response speeds of the transistor outputs?\u003c\/p\u003e\n\u003cp\u003eThe module features high-speed output response times, with an ON delay of 15 us max. and an OFF delay of 80 us max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat dielectric isolation level exists between external terminals and ground?\u003c\/p\u003e\n\u003cp\u003eDielectric strength is rated at 1,000 VAC for 1 minute between external field terminals and the GR (ground) terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat connector style is integrated on the front panel of the unit?\u003c\/p\u003e\n\u003cp\u003eField wiring interfaces directly to the front panel using a standard multi-point MIL connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306635346093,"sku":"CJ1W-OD234","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-OD234_4.jpg?v=1788156593"},{"product_id":"nx-cif210-omron-communications-interface-unit-nx-series","title":"NX-CIF210 Omron Communications Interface Unit NX-series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-CIF210\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-CIF210\u003c\/strong\u003e Communications Interface Unit, operates as a dedicated hardware component for serial RS-232C data exchange within Omron Sysmac automation networks.\u003c\/p\u003e\n\u003ch3\u003eInterface Nomenclature \u0026amp; Module Matrix\u003c\/h3\u003e\n\u003cp\u003eThe part number identifies physical serial interface options and port density attributes within the Omron NX modular product structure.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Base modular I\/O product family designed for EtherCAT and EtherNet\/IP coupler integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCIF\u003c\/strong\u003e: Communication Interface module classification handling serial protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e210\u003c\/strong\u003e: Two-port RS-232C serial communication interface with non-isolated physical channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-CIF210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.091 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.1 cm x 3.0 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.10 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Count\u003c\/td\u003e\n\u003ctd\u003e2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eNo-protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eNo isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Synchronization \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe hardware interfaces directly with the main controller backplane, supporting high backplane bus communication velocity across EtherCAT and EtherNet\/IP networks. Deterministic data routing ensures low-latency message buffer updates between serial serial devices and controller memory. Firmware flash compatibility enables online updates without compromising field memory parameters, while modular design supports flexible I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eFulfillment Package\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-CIF210 Communications Interface Unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable screwless terminal connector set\u003c\/li\u003e\n\u003cli\u003e1 x Hardware mounting and safety documentation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring \u0026amp; Mounting Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Attachment\n\u003cul\u003e\n\u003cli\u003eSnap the unit securely onto a 35 mm DIN rail in a vertical cabinet arrangement to provide passive airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSerial Line Connections\n\u003cul\u003e\n\u003cli\u003eConnect RS-232C signal conductors to the designated terminal points using shielded cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCable Shield Terminations\n\u003cul\u003e\n\u003cli\u003eGround cable shields to the cabinet functional earth busbar to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePort Isolation Limits\n\u003cul\u003e\n\u003cli\u003eMaintain common voltage potential across connected serial devices due to non-isolated port design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Operation FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow many serial ports are available on the NX-CIF210 interface card?\u003c\/p\u003e\n\u003cp\u003eThe module provides two independent RS-232C serial ports for external hardware connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication protocol is supported on these RS-232C ports?\u003c\/p\u003e\n\u003cp\u003eThe unit supports No-protocol transparent serial mode for direct ASCII or binary data transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX-CIF210 provide galvanic isolation between channels?\u003c\/p\u003e\n\u003cp\u003eNo galvanic isolation is provided between the internal backplane logic and external RS-232C circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is power supplied to the communication module?\u003c\/p\u003e\n\u003cp\u003eOperating power is drawn directly from the NX-bus backplane power supply connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the net weight of the standalone module?\u003c\/p\u003e\n\u003cp\u003eThe unit has a net weight of 0.091 Kg and a total packaged shipping weight of 1.5 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions are specified for enclosure layout?\u003c\/p\u003e\n\u003cp\u003eThe physical dimensions of the module housing measure 7.1 cm x 3.0 cm x 10 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal operating limit must be maintained in the enclosure?\u003c\/p\u003e\n\u003cp\u003eAmbient operating temperature inside the cabinet must stay between 0 deg C and 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit interface with the Sysmac CPU processor?\u003c\/p\u003e\n\u003cp\u003eData exchange routes across the high-speed NX-bus backplane interface via configured system cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306636722349,"sku":"NX-CIF210","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-cif210_1.jpg?v=1791554678"},{"product_id":"nx-da2205-omron-nx-series-analog-output-unit","title":"NX-DA2205 Omron NX-series Analog Output Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-DA2205\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-DA2205\u003c\/strong\u003e Analog Output Unit, operates as a dedicated hardware component for high-precision current conversion and signal actuation within distributed industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature \u0026amp; Architecture Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model designation defines structural channel capacity, output signal types, and internal conversion parameters within the Omron NX modular product line.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for high-speed backplane bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDA\u003c\/strong\u003e: Dedicated analog output module classification designed for current and voltage control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2205\u003c\/strong\u003e: Two-channel analog output configuration featuring high-resolution 4 to 20 mA signal generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-DA2205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20 cm x 15 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.25 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Conversion Range\u003c\/td\u003e\n\u003ctd\u003e-5 to 105 percent (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e600 ohms min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/30000 (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly with the central processing backplane via high-speed communication channels, supporting deterministic network topologies. Firmware flash compatibility ensures seamless system updates without interrupting active control signals. Furthermore, backplane bus communication velocity guarantees rapid data transfer from the controller CPU, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing conversion precision.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-DA2205 Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1 x 8-terminal screwless clamping terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Hardware safety and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting\n\u003cul\u003e\n\u003cli\u003eSecure the unit onto a standard 35 mm DIN rail inside a protective metallic enclosure designed for industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSignal Shielding\n\u003cul\u003e\n\u003cli\u003eRoute shielded twisted-pair cables to the output terminals to prevent electromagnetic interference along current loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal Connection\n\u003cul\u003e\n\u003cli\u003eInsert stripped conductor wires directly into the 8-terminal screwless clamping block without utilizing screw-tightening tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoad Resistance Compliance\n\u003cul\u003e\n\u003cli\u003eEnsure external load resistance connected to output channels is maintained at 600 ohms minimum to prevent signal clipping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Operation Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal range does the NX-DA2205 support?\u003c\/p\u003e\n\u003cp\u003eThe unit delivers a standard industrial current output ranging from 4 to 20 mA across its channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum resolution of the analog conversion?\u003c\/p\u003e\n\u003cp\u003eThe module achieves a high-resolution output of 1\/30000 across the full scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many output points are housed on this hardware module?\u003c\/p\u003e\n\u003cp\u003eThe module features two independent analog output channels with dedicated terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat allowable load resistance must be maintained on output loops?\u003c\/p\u003e\n\u003cp\u003eExternal load resistance connected to the output terminals must be 600 ohms minimum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich I\/O refreshing methods are supported by the unit?\u003c\/p\u003e\n\u003cp\u003eThe module supports selectable Synchronous I\/O refreshing or Free-Run refreshing modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the conversion range percentage limits?\u003c\/p\u003e\n\u003cp\u003eThe output conversion range extends from -5 to 105 percent of full scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the net weight of the standalone hardware?\u003c\/p\u003e\n\u003cp\u003eThe standalone unit weighs 0.7 Kg, with a packaged shipping weight of 2 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal block configuration is provided on the front panel?\u003c\/p\u003e\n\u003cp\u003eIt features a screwless clamping terminal block comprising 8 individual terminal points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306636755117,"sku":"NX-DA2205","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-da2205_1.jpg?v=1791554616"},{"product_id":"nx-ect101-omron-ethercat-slave-unit-nx-series","title":"NX-ECT101 Omron EtherCAT Slave Unit NX-series","description":"\u003cp\u003eConfigured for high-speed node communication in industrial network architectures, the \u003cstrong\u003eOmron NX-ECT101\u003c\/strong\u003e (\u003cstrong\u003eNX-ECT101\u003c\/strong\u003e EtherCAT Slave Unit) provides direct physical and electrical execution across distributed control loops.\u003c\/p\u003e\n\u003ch3\u003eDesignation Suffix \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe part number structure defines the specific network interface capabilities and physical integration boundaries within the Omron modular product ecosystem.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for high-speed backplane bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECT\u003c\/strong\u003e: Dedicated EtherCAT slave communication protocol module classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e101\u003c\/strong\u003e: Standard hardware revision supporting 100 Mbps baseband transmission over IEEE 802.3 physical layers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-ECT101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15 cm x 12 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.95 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherCAT protocol (slave only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Layer\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX (IEEE 802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Method\u003c\/td\u003e\n\u003ctd\u003eGround of 100 ohms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Velocity \u0026amp; Network Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the central processing backplane via high-speed communication channels, supporting deterministic network topologies. Firmware flash compatibility ensures seamless system upgrades without interrupting communication packets. Furthermore, backplane bus communication velocity guarantees rapid data transfer to the controller CPU, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing sampling throughput.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-ECT101 EtherCAT Slave Unit\u003c\/li\u003e\n\u003cli\u003e1 x Shielded communication connector kit\u003c\/li\u003e\n\u003cli\u003e1 x Hardware safety and installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnclosure Mounting \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePanel Mounting\n\u003cul\u003e\n\u003cli\u003eSecure the unit onto a standard 35 mm DIN rail inside a protective metallic enclosure designed for industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding Execution\n\u003cul\u003e\n\u003cli\u003eConnect a dedicated grounding wire with a resistance of 100 ohms or less to the designated functional earth terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eNetwork Cabling\n\u003cul\u003e\n\u003cli\u003eRoute category 5e or higher shielded twisted-pair cables to the 100BASE-TX Ethernet ports to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnvironmental Protection\n\u003cul\u003e\n\u003cli\u003eEnsure ambient operating humidity remains within 10% to 95% RH without condensation or icing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Operation Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication protocol does the NX-ECT101 implement?\u003c\/p\u003e\n\u003cp\u003eThe unit implements the EtherCAT protocol operating exclusively in slave node configuration mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum data transmission baud rate?\u003c\/p\u003e\n\u003cp\u003eData transmission occurs at a fixed baud rate of 100 Mbps utilizing baseband modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich IEEE physical layer standard is supported?\u003c\/p\u003e\n\u003cp\u003eThe hardware complies with the 100BASE-TX standard defined under IEEE 802.3 specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is electrical isolation maintained between circuits?\u003c\/p\u003e\n\u003cp\u003eIsolation between the external communications connector and the internal NX bus is achieved via a pulse transformer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat I\/O refreshing method does the slave unit use?\u003c\/p\u003e\n\u003cp\u003eThe module processes data updates utilizing Free-Run refreshing across the backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding resistance threshold is required for safe operation?\u003c\/p\u003e\n\u003cp\u003eThe installation must maintain an earth grounding resistance of 100 ohms or less.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the weight specification of the standalone hardware?\u003c\/p\u003e\n\u003cp\u003eThe net weight of the unit is 110 g, with a packaged shipping weight of 1 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the operational temperature limits for the device?\u003c\/p\u003e\n\u003cp\u003eThe internal panel operating temperature must stay strictly between 0 deg C and 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306639802541,"sku":"NX-ECT101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ect101_1.jpg?v=1791554381"},{"product_id":"nx-ad3204-omron-analog-i-o-unit-nx-series","title":"NX-AD3204 Omron Analog I\/O Unit NX-series","description":"\u003cp\u003eConfigured for high-speed differential analog voltage or current conversion in industrial network architectures, the \u003cstrong\u003eOmron NX-AD3204\u003c\/strong\u003e (\u003cstrong\u003eNX-AD3204\u003c\/strong\u003e Analog I\/O Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eDesignation Breakdown \u0026amp; Model Structure\u003c\/h3\u003e\n\u003cp\u003eThe product code reveals precise internal hardware architecture and input point configurations defined within the Omron NX modular ecosystem.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Modular control system series optimized for EtherCAT and EtherNet\/IP bus integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAD\u003c\/strong\u003e: Analog input module category handling continuous electrical signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3204\u003c\/strong\u003e: Four-channel high-resolution differential signal conversion configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-AD3204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e120 g max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.10 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of points\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion time\u003c\/td\u003e\n\u003ctd\u003e250 us per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Network Communication Performance\u003c\/h3\u003e\n\u003cp\u003eThe hardware interfaces directly with the central processing backplane via high-speed communication channels, supporting deterministic network topologies. Firmware flash compatibility ensures seamless system upgrades without interrupting communication packets. Furthermore, backplane bus communication velocity guarantees rapid data transfer to the controller CPU, while I\/O density scaling allows efficient system expansion across multiple modular nodes without sacrificing sampling throughput.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-AD3204 Analog I\/O Unit\u003c\/li\u003e\n\u003cli\u003e1 x Push-in terminal block connector\u003c\/li\u003e\n\u003cli\u003e1 x Safety and installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mount and Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Attachment\n\u003cul\u003e\n\u003cli\u003eMount the unit horizontally onto a standard 35 mm DIN rail inside an IP54-rated control enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSignal Shielding\n\u003cul\u003e\n\u003cli\u003eTerminate analog signal cable shields securely at the designated grounding bar to minimize electromagnetic susceptibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConductor Insertion\n\u003cul\u003e\n\u003cli\u003eStrip insulation from input wires to the specified length and insert them into the spring-loaded push-in terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermal Management\n\u003cul\u003e\n\u003cli\u003eMaintain adequate vertical clearance above and below the module to facilitate natural convection cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Inquiry and Maintenance FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input range does the NX-AD3204 support?\u003c\/p\u003e\n\u003cp\u003eThe unit processes analog signals within the 4 to 20 mA range using a differential input architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow fast is the channel conversion cycle?\u003c\/p\u003e\n\u003cp\u003eThe analog-to-digital conversion executes at a rate of 250 us per point across all active channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the native resolution of the input channels?\u003c\/p\u003e\n\u003cp\u003eConversion data is output at a resolution of 1\/8000 across the full scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input points are available on this card?\u003c\/p\u003e\n\u003cp\u003eThe module provides four distinct differential analog input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit require a separate power supply connection?\u003c\/p\u003e\n\u003cp\u003eOperating power is drawn directly from the connected NX bus backplane power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum power consumption rating?\u003c\/p\u003e\n\u003cp\u003ePower consumption does not exceed 1.10 W during normal operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should signal lines be protected against noise?\u003c\/p\u003e\n\u003cp\u003eAlways use twisted-pair shielded cables and ground the shield properly at the enclosure entry point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the allowable operating temperature span?\u003c\/p\u003e\n\u003cp\u003eThe internal cabinet temperature must remain within the 0 deg C to 55 deg C operational boundary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306642227373,"sku":"NX-AD3204","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ad3204_1.jpg?v=1791554069"},{"product_id":"nx-ec0142-omron-incremental-encoder-input-unit-nx-series","title":"NX-EC0142 Omron Incremental Encoder Input Unit NX-series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-EC0142\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-EC0142\u003c\/strong\u003e Position Interface Unit, operates as a dedicated hardware component for high-speed pulse counting and signal evaluation within EtherCAT and NX-bus system architectures.\u003c\/p\u003e\n\u003ch3\u003eProduct Classification \u0026amp; Variant Structure\u003c\/h3\u003e\n\u003cp\u003eThe NX-EC0142 model designation identifies specific physical terminal layouts and signal handling capabilities within the Omron NX series positioning group.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Base modular I\/O product line for EtherCAT and EtherNet\/IP bus couplers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEC\u003c\/strong\u003e: High-speed incremental encoder input module classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0142\u003c\/strong\u003e: Single-channel line receiver input specification with 24 push-in terminal points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-EC0142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e130 g max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.45 W max. (NX bus supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Inputs\u003c\/td\u003e\n\u003ctd\u003ePhases A, B, Z (Line receiver) + 3 External Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal block (12 terminals x 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run, Synchronous, or Task Period Prioritized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBus Communication Velocity \u0026amp; Processing Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the NX-bus backplane to maintain deterministic data transmission across EtherNet\/IP and EtherCAT networks. High-speed counter latching synchronizes with the master controller task period to eliminate jitter during continuous motion cycles. Backplane communication velocity ensures real-time position updates, while internal firmware flash compatibility allows seamless controller synchronization without dropped pulse sequences.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-EC0142 Incremental Encoder Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x Integrated 24-point screwless push-in terminal block\u003c\/li\u003e\n\u003cli\u003e1 x Hardware mounting documentation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation \u0026amp; Field Wiring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting Position\n\u003cul\u003e\n\u003cli\u003eAttach the unit securely to a 35 mm DIN rail in a vertical orientation to allow natural thermal dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWiring Precautions\n\u003cul\u003e\n\u003cli\u003eUse shielded twisted-pair cables for Phase A, B, and Z line receiver signals to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTerminal Preparation\n\u003cul\u003e\n\u003cli\u003eStrip signal conductors to 10 mm and insert directly into the push-in terminal points without using screw-tightening tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding Execution\n\u003cul\u003e\n\u003cli\u003eConnect the cable shield directly to the functional ground bar near the module to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Functionality \u0026amp; Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input signal format does the NX-EC0142 interface accept?\u003c\/p\u003e\n\u003cp\u003eThe unit accepts RS-422A line receiver input signals for Phases A, B, and Z alongside three digital external inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is I\/O refreshing synchronized across the backplane bus?\u003c\/p\u003e\n\u003cp\u003eThe module supports Free-Run refreshing, Synchronous I\/O refreshing, and Task Period Prioritized refreshing modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum electrical weight specification for shipping?\u003c\/p\u003e\n\u003cp\u003eThe net module weight is 130 g maximum, while the standard shipping weight rating is 1 Kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal block configuration is provided on the front panel?\u003c\/p\u003e\n\u003cp\u003eIt features a detachable screwless push-in terminal block housing 24 individual terminal points arranged in two columns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit handle high-speed pulse counting?\u003c\/p\u003e\n\u003cp\u003eThe hardware evaluates differential line receiver signals directly into internal counter registers in pulse units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require external power supply connections?\u003c\/p\u003e\n\u003cp\u003eOperating power is drawn from the NX-bus power supply, while external input signals require field power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal operating range must be maintained in the enclosure?\u003c\/p\u003e\n\u003cp\u003eAmbient operating temperature inside the control cabinet must remain between 0 deg C and 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are shield lines terminated at the module terminals?\u003c\/p\u003e\n\u003cp\u003eShield wires must be grounded short at the terminal strip or cabinet ground bar to mitigate high-frequency noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306642292909,"sku":"NX-EC0142","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ec0142-1.jpg?v=1791553978"},{"product_id":"omron-cj1w-nc413-position-control-unit-cj1-series","title":"Omron CJ1W-NC413 Position Control Unit CJ1 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-NC413\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-NC413\u003c\/strong\u003e Position Control Unit, operates as a dedicated hardware component for 4-axis motion trajectory execution via differential line-driver outputs within CJ1 PLC networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-NC413\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-NC413\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e CJ1 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Category:\u003c\/strong\u003e CJ1 Special I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Memory Allocation:\u003c\/strong\u003e 20 Words\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-NC413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eOpen-loop control by pulse train output (Line-driver output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Control Axes\u003c\/td\u003e\n\u003ctd\u003e4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Requirement Word\u003c\/td\u003e\n\u003ctd\u003e20 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Range Ramp Time\u003c\/td\u003e\n\u003ctd\u003e0 to 250 s until maximum speed is reached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.37 A at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-NC413 transfers motion commands across the CJ1 backplane bus, utilizing 20 words of allocated I\/O memory to command four independent motion axes. Internal logic executes open-loop position profiling via high-frequency differential line-driver pulse train outputs. Backplane communication cycles execute within optimized bus refresh intervals, maintaining high I\/O density scaling and determinism across multi-axis trajectories without degrading CPU scan execution speeds. Acceleration and deceleration profiles support velocity scaling from baseline up to maximum pulse rates over ramp periods configured from 0 to 250 s.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-NC413 Position Control Unit\u003c\/li\u003e\n\u003cli\u003e1x CJ1 Bus Connector Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the unit into the CJ1 rack slot and engage the top and bottom slider catches to establish backplane bus connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate 4-axis line-driver output signals using shielded twisted-pair conductors wired to external servo or stepper drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Encase all pulse-train signal runs in continuous 360-deg braid shielding bonded directly to the panel earth bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the CJ1 rack assembly to functional earth (FE) through a dedicated low-impedance copper busbar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat positioning control method is implemented by the CJ1W-NC413?\u003c\/p\u003e\n\u003cp\u003eThe module executes open-loop position control using high-speed differential line-driver pulse train outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many motion axes can the CJ1W-NC413 manage concurrently?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates output processing logic for controlling up to 4 independent motion axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much CPU I\/O memory space is allocated to the CJ1W-NC413?\u003c\/p\u003e\n\u003cp\u003eThe module requires an allocation of 20 words within the CJ1 PLC I\/O memory block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat acceleration and deceleration ramp range is configurable on this unit?\u003c\/p\u003e\n\u003cp\u003eThe velocity acceleration and deceleration ramp range is adjustable from 0 to 250 s to reach maximum target speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical envelope dimensions apply to the CJ1W-NC413 hardware chassis?\u003c\/p\u003e\n\u003cp\u003eThe unit physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with an overall module weight of 1.2 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-NC413 require external 24 VDC auxiliary power for line-driver outputs?\u003c\/p\u003e\n\u003cp\u003eInternal logic and line-driver output stages draw operation power directly from the 5 VDC backplane bus at 0.37 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat field wiring protection is recommended for high-frequency pulse outputs?\u003c\/p\u003e\n\u003cp\u003ePulse train conductors require shielded twisted-pair cables with continuous 360-deg braid shielding bonded to functional earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating ambient temperature range is certified for this position control unit?\u003c\/p\u003e\n\u003cp\u003eThe hardware operates within certified parameters across an ambient temperature range of 0 deg C ... +55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306643996845,"sku":"CJ1W-NC413","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-NC413_1.jpg?v=1788159813"},{"product_id":"nx-ecs112-omron-nx-series-ssi-input-unit","title":"NX-ECS112 | Omron | NX-series SSI Input Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-ECS112\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-ECS\u003c\/strong\u003e SSI Input Unit, operates as a dedicated hardware component for absolute encoder position feedback sampling within NX bus field networks.\u003c\/p\u003e\n\u003ch3\u003eInternal Model Designation Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Base Slice I\/O Platform Architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEC\u003c\/strong\u003e: Position Interface Module Category\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS112\u003c\/strong\u003e: 1-Channel Synchronous Serial Interface (SSI) Hardware Configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-ECS112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.065 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.2 cm x 7.1 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.10 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connections\u003c\/td\u003e\n\u003ctd\u003eScrewless push-in terminal block (12 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Signal Standard\u003c\/td\u003e\n\u003ctd\u003eEIA RS-422-A line driver \/ receiver levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Data Length\u003c\/td\u003e\n\u003ctd\u003e32 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Baud Rates\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 200 kHz, 300 kHz, 400 kHz, 500 kHz, 1.0 MHz, 1.5 MHz, 2.0 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Coding\u003c\/td\u003e\n\u003ctd\u003eNo conversion, binary code, or gray code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eDigital isolator isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP \u0026amp; Backplane Bus Latency Performance\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with the internal NX backplane bus to transfer absolute encoder positions down to sub-millisecond task periods. Deterministic synchronization ensures cycle-to-cycle data alignment across EtherNet\/IP network couplers. Firmware flash compatibility validation executes automatically during initialization to match backplane revision baselines prior to establishing I\/O map refreshing.\u003c\/p\u003e\n\u003ch3\u003eStandard Shipping Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-ECS112 SSI Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x 12-Terminal Screwless Push-In Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Cable Shielding\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign side guides and press the unit firmly onto the DIN rail until the locking lever engages.\u003c\/li\u003e\n\u003cli\u003eStrip wiring to 10 mm and insert directly into the push-in terminal points without using tools.\u003c\/li\u003e\n\u003cli\u003eRoute RS-422-A differential clock and data pairs through twisted-pair shielded cables separate from power leads.\u003c\/li\u003e\n\u003cli\u003eGround the cable shield wire at the NX bus ground terminal bar to prevent high-frequency differential noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal levels are used for the clock outputs and data inputs?\u003c\/p\u003e\n\u003cp\u003eThe output clock (C+, C-) and input data (D+, D-) circuits operate using differential line levels compliant with the EIA standard RS-422-A specification for high noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich data coding formats are supported by the input processing logic?\u003c\/p\u003e\n\u003cp\u003eThe unit parses incoming SSI data streams formatted as raw binary code, gray code, or direct pass-through without conversion, configurable up to 32 bits maximum bit length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit be removed or inserted while the NX backplane is powered?\u003c\/p\u003e\n\u003cp\u003eHot-swapping the individual module while the CPU or coupler bus is energized is strictly prohibited. Disconnect main power before removing the module to prevent backplane bus corruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat I\/O refreshing modes can be selected for encoder sampling?\u003c\/p\u003e\n\u003cp\u003eThe unit supports Free-Run refreshing, synchronous I\/O refreshing, or task period prioritized refreshing depending on the master CPU task configuration and cycle times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire gauges are compatible with the screwless terminal block?\u003c\/p\u003e\n\u003cp\u003eThe removable 12-pin terminal block accepts solid or stranded copper conductors ranging from AWG 24 to AWG 16 (0.2 mm sq to 1.5 mm sq) with bare ends or ferrules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the digital isolator protect internal controller logic?\u003c\/p\u003e\n\u003cp\u003eDigital galvanic isolators decouple external RS-422-A field signal circuits from the internal NX bus power and communication lines, suppressing ground loops and voltage transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat selection of clock frequencies is available for SSI encoder polling?\u003c\/p\u003e\n\u003cp\u003eBaud rates can be configured via software to 100 kHz, 200 kHz, 300 kHz, 400 kHz, 500 kHz, 1.0 MHz, 1.5 MHz, or 2.0 MHz to match encoder transmission distance limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are firmware mismatch errors handled by the backplane bus?\u003c\/p\u003e\n\u003cp\u003eIf the firmware revision of the module does not match system configuration parameters stored in the master coupler, an I\/O verification error generates and blocks data refresh.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306644160685,"sku":"NX-ECS112","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-ECS112.webp?v=1790779247"},{"product_id":"cj1w-ad04u-omron-isolated-type-universal-input-unit-cj-series","title":"CJ1W-AD04U Omron Isolated-type Universal Input Unit CJ Series","description":"\u003cp\u003eConfigured for multi-channel analog signal acquisition and digitized temperature scaling in CJ Series backplanes, the \u003cstrong\u003eOmron CJ1W-AD04U\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-AD04U\u003c\/strong\u003e Isolated-type Universal Input Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Designation and Input Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-AD04U\u003c\/strong\u003e functions as a Special I\/O Unit mapped directly into the internal address table of Omron CJ-series CPU systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJ1W\u003c\/strong\u003e: Dedicated module platform housing for CJ1G, CJ1M, CJ2M, and CJ2H programmable controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAD\u003c\/strong\u003e: Analog-to-digital processing module architecture converting field input signals to 16-bit process registers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e04U\u003c\/strong\u003e: Designator specifying 4 channel inputs with universal signal processing (RTD, Thermocouple, Voltage, Current).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Number Allocation\u003c\/strong\u003e: Consumes exactly 1 Special I\/O Unit address assigned via front rotary selector switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-AD04U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e4 points (individually configured per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eUniversal: Pt100, JPt100, Pt1000, K, J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e250 ms for 4 input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (RTD Input)\u003c\/td\u003e\n\u003ctd\u003e(+-0.3% of PV or +-0.8 deg C, whichever is larger) +-1 digit max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Thermocouple Input)\u003c\/td\u003e\n\u003ctd\u003e(+-0.3% of PV or +-1.5 deg C, whichever is larger) +-1 digit max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Voltage\/Current Input)\u003c\/td\u003e\n\u003ctd\u003e+-0.3% of F.S. +-1 digit max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.32 A at 5 VDC (1.6 W max. via internal backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eRemovable screw terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 120 mm x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Synchronization \u0026amp; Firmware Flash Execution\u003c\/h3\u003e\n\u003cp\u003eThe module transfers digitized process variables across the local CJ backplane bus into dedicated CPU memory words every scan cycle. Internal backplane bus communication velocity handles fast register transfers without introducing firmware execution jitter. Dynamic scaling registers and onboard firmware flash compatibility maintain signal calibration parameters across power cycles without requiring external setup software reload routines.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Content\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-AD04U Isolated-type Universal Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable front terminal block connector\u003c\/li\u003e\n\u003cli\u003e1 x Hardware wiring and mounting instruction document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Power Cutoff\u003c\/strong\u003e: Switch off the main rack power supply prior to sliding the module into or out of the CJ-series CPU or expansion rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded Cabling\u003c\/strong\u003e: Route thermocouple, RTD, and 4-20 mA current signals using twisted-pair shielded cabling. Connect the shield drain wire to earth ground at the panel side only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screws Verification\u003c\/strong\u003e: Tighten terminal block connection screws to a torque rating of 0.5 N m to ensure stable electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Loop Resistors\u003c\/strong\u003e: Ensure correct wiring configurations when selecting current inputs to engage internal precision shunt loops without overloading inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan each of the 4 input channels be set to a different signal range on the CJ1W-AD04U?\u003c\/p\u003e\n\u003cp\u003eYes. Range selections for Pt100, thermocouples, voltage, or current are configured independently per channel in system memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total conversion speed for updating all 4 analog channels?\u003c\/p\u003e\n\u003cp\u003eThe unit completes a conversion cycle for all 4 inputs within a maximum sampling period of 250 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-AD04U require an external 24 VDC power supply to operate logic circuits?\u003c\/p\u003e\n\u003cp\u003eNo. The module draws its operational power of 0.32 A directly from the internal 5 VDC PLC backplane bus rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-AD04U on a live CJ1 PLC rack?\u003c\/p\u003e\n\u003cp\u003eNo. Removing or inserting the input unit while the PLC backplane power is active causes backplane bus errors and stops CPU execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many unit numbers does the module occupy in the PLC CPU memory map?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-AD04U consumes exactly 1 Special I\/O Unit address number set via the rotary switch on the module front panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if a thermocouple input wire breaks during system operation?\u003c\/p\u003e\n\u003cp\u003eThe module detects a wire disconnection fault, sets a burnout flag bit in CPU memory, and drives the channel value off-scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of external connection interface is provided on the front panel?\u003c\/p\u003e\n\u003cp\u003eField wiring attaches via a removable screw terminal block, allowing module swap-outs without disconnecting individual signal wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does channel isolation benefit field measurements on process loops?\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation between channels prevents ground loops and electrical interference from skewing signal conversion accuracies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306644881581,"sku":"CJ1W-AD04U","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-AD04U_2.jpg?v=1788154976"},{"product_id":"omron-cj1w-ad081-v1-analog-input-unit-cj-series","title":"Omron CJ1W-AD081-V1 Analog Input Unit CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-AD081-V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-AD081-V1\u003c\/strong\u003e Analog Input Unit, operates as a dedicated hardware component for multi-channel analog signal acquisition and analog-to-digital conversion within Omron CJ Series platforms. Configured for high-density physical signal monitoring, this high-resolution Special I\/O Unit processes up to 8 independent analog input channels, converting voltage and current process inputs into digital values for real-time PLC backplane processing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003ctd\u003eSystem Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCJ1W-AD081-V1\u003c\/td\u003e\n\u003ctd\u003eSpecial I\/O High-Density Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003ctd\u003eModular PLC Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Variant\u003c\/td\u003e\n\u003ctd\u003eCJ1W Architecture\u003c\/td\u003e\n\u003ctd\u003e8-Channel High-Resolution Analog Processing Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-AD081-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg (Net) \/ 1.5 kg (Shipping Packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.9 cm x 3.1 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 10.0 cm x 8.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.42 A at 5 VDC (Internal Backplane Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to +10 V, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e1\/4000 or 1\/8000 (selectable per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e1.0 ms\/channel (1\/4000) or 2.0 ms\/channel (1\/8000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Classification\u003c\/td\u003e\n\u003ctd\u003eSpecial I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation between inputs and backplane; non-isolated between input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Backplane Bus Velocity and High-Density I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-AD081-V1 utilizes the CJ Series backplane bus to deliver high-velocity data transfer to the main processor without impacting cycle scan times. Operating as a Special I\/O Unit, it scales I\/O density by providing 8 analog channels in a compact 31 mm backplane slot width. Digital conversion results are continuously mapped into designated Special I\/O Unit memory areas, enabling deterministic scan updating across all 8 channels. Integrated firmware functions include mean value processing, peak value holding, and broken-wire detection for 1 to 5 V and 4 to 20 mA ranges.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-AD081-V1 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1x 18-Point Detachable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1x Quick Reference Manual Document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e Lock the module onto a 35 mm DIN rail within the CJ Series CPU rack or Expansion rack. Ensure proper insertion into the adjacent backplane connector prior to engaging the slide locks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Connect field wiring to the 18-point detachable terminal block using M3 screws. For current inputs (4 to 20 mA), short the V+ and I+ terminals for the respective channel using the supplied terminal jumpers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Use twisted-pair shielded cable for all analog signal paths. Connect the outer cable braid to a 360-deg shield clamp at the panel ground bar and maintain system frame ground (FG) resistance below 100 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Isolation:\u003c\/strong\u003e Do not routed high-voltage AC cables alongside the low-voltage DC analog signal lines. Maintain a minimum clearance distance of 100 mm from power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal input ranges are supported by the CJ1W-AD081-V1?\u003c\/p\u003e\n\u003cp\u003eThe module supports 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to +10 V voltage inputs, and 4 to 20 mA current inputs per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total conversion speed across all 8 analog channels?\u003c\/p\u003e\n\u003cp\u003eTotal conversion speed is 1.0 ms per active channel at 1\/4000 resolution, or 2.0 ms per active channel at 1\/8000 resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs channel-to-channel isolation provided on the CJ1W-AD081-V1?\u003c\/p\u003e\n\u003cp\u003eNo, inputs are isolated from the PLC backplane via photocouplers, but individual input channels share a common ground reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are current inputs configured on the terminal block?\u003c\/p\u003e\n\u003cp\u003eCurrent input mode requires physically shorting the V+ and I+ terminals for that specific channel on the 18-point terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan individual input channels be disabled if unused?\u003c\/p\u003e\n\u003cp\u003eYes, unused channels can be disabled via unit setup memory settings to optimize system conversion time and prevent floating conversion errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-AD081-V1 on the backplane?\u003c\/p\u003e\n\u003cp\u003eNo, main power to the PLC power supply unit must be turned off before inserting or removing the CJ1W-AD081-V1 module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire size is recommended for the detachable terminal block?\u003c\/p\u003e\n\u003cp\u003eUse stranded copper wiring from AWG 24 to AWG 16 (0.2 to 1.25 mm sq) with M3 ring or spade crimp terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit signal a broken wire condition?\u003c\/p\u003e\n\u003cp\u003eWhen configured for 1 to 5 V or 4 to 20 mA, an input level below the valid threshold sets a disconnection flag in the Special I\/O memory area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306645340333,"sku":"CJ1W AD081-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-AD081-V1_3_c02f5c47-692a-4d4d-99f6-906c1d7ea9d0.jpg?v=1788154664"},{"product_id":"omron-cj1w-da042v-analog-output-unit-cj-series","title":"Omron CJ1W-DA042V Analog Output Unit CJ Series","description":"\u003cp\u003eThe \u003cb\u003eOmron CJ1W-DA042V\u003c\/b\u003e, also cataloged as the \u003cb\u003eCJ1W-DA042V\u003c\/b\u003e Analog Output Unit, operates as a dedicated hardware component for high-speed digital-to-analog voltage signal conversion within Omron CJ-series PLC systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBase Part Number:\u003c\/b\u003e CJ1W-DA042V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Omron\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eClassification:\u003c\/b\u003e Special I\/O Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAllocated Unit Numbers:\u003c\/b\u003e 1 unit number allocated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eOutput Channel Count:\u003c\/b\u003e 4 High-Speed Voltage Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCJ1W-DA042V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 cm x 10.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 W (0.40 A at 5 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.40 A at 5 VDC (backplane load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 voltage outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Range Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSet separately for each output channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Ranges \u0026amp; Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 5 V (1\/10,000 resolution), 0 to 10 V (1\/20,000 resolution), -10 to 10 V (1\/40,000 resolution)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConversion Period\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 us\/1 point, 25 us\/2 points, 30 us\/3 points, 35 us\/4 points (Direct conversion provided)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature Accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/-0.3% of Full Scale at 25 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRemovable Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eOmron CJ1W-DA042V\u003c\/b\u003e interfaces directly with the high-speed CJ-series backplane bus to deliver direct digital-to-analog conversion across 4 independent voltage output channels. Operating as a Special I\/O Unit, it executes internal D\/A updates at hardware speeds down to 20 us for 1 point and 35 us for 4 points, enabling real-time motion control and fast actuator response.\u003c\/p\u003e\n\u003cp\u003eThe unit supports channel-specific output configuration, allowing mixed signal ranges (1 to 5 V, 0 to 10 V, and -10 to 10 V) across a single module. Internal firmware registers synchronize output data across allocated Special I\/O Unit memory areas during backplane refresh, maintaining signal accuracy (+\/-0.3% of F.S. at 25 deg C) without impacting CPU scan cycle velocity.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1x Omron CJ1W-DA042V Analog Output Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Removable Terminal Block Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1x Hardware Installation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRack Mounting:\u003c\/b\u003e Mount the CJ1W-DA042V onto the CJ-series CPU Rack or Expansion Rack, sliding the unit along the DIN rail guide until top and bottom locking levers click into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUnit Number Setting:\u003c\/b\u003e Set the rotary unit number switch on the front panel (0 to 95) before restoring system power to allocate Special I\/O Unit memory words.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eField Wiring:\u003c\/b\u003e Wire voltage output devices to the removable terminal block using twisted-pair shielded cables to suppress electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGrounding \u0026amp; Shielding:\u003c\/b\u003e Terminate cable braid shields at a single point to the functional earth (FE) terminal using a 360-deg braid clamp. Ensure the rack ground wire is at least 2.0 mm sq.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the backplane current consumption for the CJ1W-DA042V?\u003c\/p\u003e\n\u003cp\u003eThe CJ1W-DA042V draws a nominal current of 0.40 A at 5 VDC directly from the internal CJ backplane power bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the conversion speeds for different output channel configurations?\u003c\/p\u003e\n\u003cp\u003eConversion timing is 20 us for 1 point, 25 us for 2 points, 30 us for 3 points, and 35 us for all 4 output points combined.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan output voltage ranges be configured independently per channel?\u003c\/p\u003e\n\u003cp\u003eYes, signal ranges (1 to 5 V, 0 to 10 V, -10 to 10 V) are configured separately for each individual output channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-DA042V on an active backplane?\u003c\/p\u003e\n\u003cp\u003eNo, power to the CPU Rack and connected Expansion Racks must be completely isolated before inserting or removing the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital resolution does the CJ1W-DA042V provide for output ranges?\u003c\/p\u003e\n\u003cp\u003eResolution is 1\/10,000 for 1 to 5 V, 1\/20,000 for 0 to 10 V, and 1\/40,000 for -10 to 10 V signal ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat field termination hardware is supplied with the CJ1W-DA042V?\u003c\/p\u003e\n\u003cp\u003eThe module includes a front-mounted removable terminal block for field output wiring connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many unit numbers are allocated to the CJ1W-DA042V in CPU memory?\u003c\/p\u003e\n\u003cp\u003eThe unit allocates exactly 1 Special I\/O Unit number within the CPU unit memory area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding procedure minimizes high-frequency noise on voltage outputs?\u003c\/p\u003e\n\u003cp\u003eUse shielded twisted-pair conductors with a 360-deg braid ground connection linked directly to protective earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306645668013,"sku":"CJ1W-DA042V","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-DA042V_1.jpg?v=1788155543"},{"product_id":"nx-da2605-omron-analog-i-o-unit-nx-series","title":"NX-DA2605 Omron Analog I\/O Unit NX- Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-DA2605\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-DA2605\u003c\/strong\u003e Analog I\/O unit, operates as a dedicated hardware component for high-resolution voltage signal output processing within EtherCAT and NX-bus I\/O system architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Matrix \u0026amp; Architecture\u003c\/h3\u003e\n\u003cp\u003eThe NX-DA2605 is structured as a dedicated analog output expansion module within the Omron NX series platform. The base hardware model provides multi-channel digital-to-analog signal conversion without requiring additional sub-component option boards. Internal circuitry translates internal system bus digital values directly into stable differential voltage outputs across the -10 to +10 V range.\u003c\/p\u003e\n\u003ch3\u003eSystem Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-DA2605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Method\u003c\/td\u003e\n\u003ctd\u003eDifferential Input\/Output Circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e7.1 x 1.2 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Bus Communication\u003c\/td\u003e\n\u003ctd\u003eEtherCAT \/ NX-bus deterministic synchronous bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; High-Density Scalability\u003c\/h3\u003e\n\u003cp\u003eThe NX-DA2605 interface utilizes high-speed backplane bus communication velocity to deliver deterministic response synchronization across scalable PLC platforms. High-density I\/O configuration allows tight physical packing on standard DIN-rail topologies without degradation of throughput. Internal firmware flash compatibility ensures synchronized operational execution alongside CPU units over EtherCAT networks, eliminating loop latencies in closed-loop voltage control operations.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-DA2605 Analog I\/O Unit\u003c\/li\u003e\n\u003cli\u003eIntegrated Push-In Plus terminal block assembly\u003c\/li\u003e\n\u003cli\u003eFactory test documentation and installation sheet\u003c\/li\u003e\n\u003cli\u003eAnti-static protective enclosure packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Assembly \u0026amp; Wiring Practice\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Assembly\u003c\/strong\u003e: Secure the module onto 35 mm DIN rail profiles using the integrated locking mechanism. Ensure solid mechanical connection to avoid physical stress on internal bus contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Route differential analog voltage lines using twisted-pair shielded cables. Earth the cable shield at a single termination point to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Distance\u003c\/strong\u003e: Maintain separation between low-voltage signal cabling and heavy AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDispatch \u0026amp; Freight Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipping timeline: 2-7 days when payment finish\u003c\/li\u003e\n\u003cli\u003eCarrier service: Express transport via DHL, FEDEX, or UPS\u003c\/li\u003e\n\u003cli\u003eEnclosure standard: ESD anti-static industrial packaging with high-density shock-absorption padding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Technical Inquiries\u003c\/h3\u003e\n\u003cp\u003eQ: What is the isolation capability between distinct operational circuits on the NX-DA2605?\u003c\/p\u003e\n\u003cp\u003eA: The internal hardware maintains an insulation resistance of at least 20 MOhm at 100 VDC between isolated circuit paths to prevent stray potential damage.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support single-ended or differential output signal loops?\u003c\/p\u003e\n\u003cp\u003eA: The unit architecture utilizes differential output routing designed for industrial voltage ranges spanning -10 to +10 V.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit exchange operational data with the primary PLC controller?\u003c\/p\u003e\n\u003cp\u003eA: Data exchange is executed deterministically over the proprietary NX-bus backplane interface linked to the main CPU or EtherCAT coupler unit.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306649764013,"sku":"NX-DA2605","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-da2605_1.jpg?v=1790660895"},{"product_id":"omron-nx-ad4608-nx-series-analog-i-o-unit","title":"Omron NX-AD4608 NX Series Analog I\/O Unit","description":"\u003cp\u003eConfigured for high-speed differential voltage measurement in NX I\/O Bus architectures, the \u003cstrong\u003eOmron NX-AD4608\u003c\/strong\u003e (\u003cstrong\u003eNX-AD4608\u003c\/strong\u003e Analog I\/O Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-AD4608 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x Push-in Terminal Block (16-point, detachable)\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-AD4608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O System\u003c\/td\u003e\n\u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eLinear Analog (-10 to 10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Type\u003c\/td\u003e\n\u003ctd\u003eDifferential input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 Bit (1\/32000 full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e0.08 ms\/unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eSynchronous I\/O refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connection Type\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetachable Terminal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e10 cm x 1.2 cm x 7.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Deterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit communicates directly via the synchronous NX I\/O Bus, linking real-time analog signal acquisition with EtherCAT master controllers. Synchronous refreshing ensures signal processing latencies remain tightly bounded across high-density I\/O configurations. Differential input circuitry suppresses common-mode electrical noise across all 8 voltage channels, preserving 15-bit digital resolution integrity. Firmware compatibility is dictated by the host CPU or EtherCAT Coupler Unit firmware revisional limits.\u003c\/p\u003e\n\u003ch3\u003eMounting \u0026amp; Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the entire NX bus backplane before engaging the unit onto the DIN rail track.\u003c\/li\u003e\n\u003cli\u003eAlign the DIN rail lock mechanisms top and bottom, pressing the module backward until an audible click confirms engagement.\u003c\/li\u003e\n\u003cli\u003eWire analog signal lines using shielded twisted-pair conductors to mitigate external electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eStrip wire ends according to the push-in terminal specification (8 to 10 mm) before inserting into the connector block.\u003c\/li\u003e\n\u003cli\u003eSecure signal cable shielding directly to the panel ground bar using low-impedance grounding clamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the conversion speed for the analog input processing?\u003c\/p\u003e\n\u003cp\u003eThe conversion time operates at 0.08 ms per unit, delivering high-speed data updating synchronized with the NX bus cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal range does the module accept on its inputs?\u003c\/p\u003e\n\u003cp\u003eThe unit is strictly configured for linear bipolar voltage inputs ranging from -10 VDC to +10 VDC across all 8 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the field wires connected to the physical hardware interface?\u003c\/p\u003e\n\u003cp\u003eWiring connects via a single 16-point detachable push-in terminal block, permitting rapid replacement without rewiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module feature differential or single-ended input circuitry?\u003c\/p\u003e\n\u003cp\u003eThe 8 analog channels utilize differential input circuits to maximize noise rejection across industrial field environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital resolution is achieved by the analog-to-digital converter?\u003c\/p\u003e\n\u003cp\u003eThe internal converter provides 15-bit resolution across the full -10 VDC to +10 VDC linear input scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the terminal block be removed while the system is installed?\u003c\/p\u003e\n\u003cp\u003eYes, the front terminal block is fully detachable from the main module housing for maintenance accessibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat IP rating applies to this specific module enclosure?\u003c\/p\u003e\n\u003cp\u003eThe hardware features an IP20 protection rating and must be mounted inside an appropriately sealed control enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the analog acquisition synchronized with the system CPU bus?\u003c\/p\u003e\n\u003cp\u003eYes, the module supports synchronous I\/O refreshing to ensure deterministic data transfer across the NX backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306652025005,"sku":"NX-AD4608","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ad4608_1.jpg?v=1790660535"},{"product_id":"nx-ec0122-omron-nx-i-o-series-encoder-input-module","title":"NX-EC0122 Omron NX I\/O Series Encoder Input Module","description":"\u003cp\u003eConfigured for high-speed position tracking in NX I\/O Bus automation setups, the \u003cstrong\u003eOmron NX-EC0122\u003c\/strong\u003e (\u003cstrong\u003eNX-EC0122\u003c\/strong\u003e Encoder Input Module) provides direct physical\/electrical execution for single-channel incremental encoder signal processing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Code \u0026amp; Nomenclature Structural Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Denotes the Omron NX series modular I\/O platform designed for EtherCAT and EtherNet\/IP bus couplers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEC\u003c\/strong\u003e: Designates high-speed position and encoder input signal processing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0122\u003c\/strong\u003e: Specifies a single-channel incremental encoder interface utilizing 24 VDC PNP inputs with a maximum input frequency of 500 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Physical \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-EC0122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eIncremental Encoder Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1 Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eIncremental Encoder, PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Frequency\u003c\/td\u003e\n\u003ctd\u003e500 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eFree running, Synchronous, Task period prioritized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003ePush-in Terminal (16-point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetachable Terminal Block\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOV (V+) Terminals\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOG (V-) Terminals\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Unpacked)\u003c\/td\u003e\n\u003ctd\u003e70 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1000 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (Height x Width x Depth)\u003c\/td\u003e\n\u003ctd\u003e104.5 mm x 12.0 mm x 80.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Backplane Bus Synchronization \u0026amp; Determinism\u003c\/h3\u003e\n\u003cp\u003eThe NX-EC0122 interfaces directly with the NX bus backplane, transmitting high-frequency pulse counts to the primary motion controller within deterministic EtherCAT update cycles. Internal hardware latches pulse transitions up to 500 kHz without frame drop, maintaining exact time-stamped synchronization across multi-axis motion networks. Backplane firmware synchronization minimizes processing jitter during rapid acceleration and deceleration sequences.\u003c\/p\u003e\n\u003ch3\u003eComplete Scope of Delivery \u0026amp; Package Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-EC0122 Encoder Input Module\u003c\/li\u003e\n\u003cli\u003e1 x Detachable 16-pin Push-in Terminal Block\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Identification Label Strip\u003c\/li\u003e\n\u003cli\u003e1 x Printed Industrial Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Wiring Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Interface\u003c\/strong\u003e: Mount vertically onto standard 35 mm DIN rail (TH35-7.5\/TH35-15). Ensure top and bottom retaining clips snap securely into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring\u003c\/strong\u003e: Strip solid or ferruled wires to 10 mm. Insert conductors directly into the push-in terminals without tools. Use a flat-blade screwdriver (2.5 mm width) to release unferruled stranded wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Protocol\u003c\/strong\u003e: Route encoder signal lines in shielded twisted-pair cables. Ground the cable shield at the dedicated functional ground terminal on the NX bus power supply module to prevent high-frequency noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation Distance\u003c\/strong\u003e: Maintain a minimum physical clearance of 100 mm between encoder signal wiring and high-voltage power lines or variable frequency drive (VFD) output cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Operational Characteristics \u0026amp; Technical Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the PNP encoder input channel process differential versus single-ended signals?\u003c\/p\u003e\n\u003cp\u003eThe NX-EC0122 accepts 24 VDC PNP single-ended signals. Differential RS-422 signals are not natively supported and require external signal conditioning modules prior to terminal connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum permissible cable length between the incremental encoder and the module?\u003c\/p\u003e\n\u003cp\u003eThe maximum recommended signal line length is 30 meters, provided low-capacitance shielded cables are used to limit signal attenuation at the maximum 500 kHz counting frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the detachable push-in terminal block be removed under power?\u003c\/p\u003e\n\u003cp\u003eNo. Disconnect backplane power and field power before detaching the terminal block to prevent unexpected latch-up states or transient electrical damage to internal logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the IOV and IOG terminals utilized on the terminal block?\u003c\/p\u003e\n\u003cp\u003eThe 4 IOV (V+) and 4 IOG (V-) terminals provide internal branch distribution for auxiliary field sensors and encoder power supply lines directly from the module interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal processing mode should be configured for strict motion synchronization?\u003c\/p\u003e\n\u003cp\u003eSelect Synchronous I\/O refreshing mode in the controller configuration to tie encoder counter latching directly to the EtherCAT distributed clock (DC) cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input frequency exceeds the 500 kHz limit?\u003c\/p\u003e\n\u003cp\u003eExceeding 500 kHz results in pulse attenuation, missed counts, or position tracking errors without triggering an immediate hardware fault on the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX-EC0122 support onboard digital outputs for high-speed cam switches?\u003c\/p\u003e\n\u003cp\u003eNo. The NX-EC0122 contains zero pulse or digital output channels. Output processing must be routed via dedicated digital output modules over the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs functional safety or SIL rating applicable to the NX-EC0122 module?\u003c\/p\u003e\n\u003cp\u003eNo. The NX-EC0122 is a standard position-feedback card and carries no SIL safety certification according to IEC 61508.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306653040813,"sku":"NX-EC0122","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ec0122_2.jpg?v=1790660449"},{"product_id":"nx-od6256-5-omron-digital-output-unit-nx-series","title":"NX-OD6256-5 Omron Digital Output Unit NX Series","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron NX-OD6256-5\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"45\"\u003eNX-OD6256\u003c\/b\u003e Digital I\/O Unit, operates as a dedicated hardware component for high-density 24 VDC switching and load drive execution within Sysmac EtherCAT and EtherNet\/IP networks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eInternal Part Designation Scheme\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Slice I\/O modular platform family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eOD\u003c\/b\u003e: Digital transistor output function group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e6256\u003c\/b\u003e: High-density configuration with 32 transistor output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e5\u003c\/b\u003e: PNP logic output type with 1-wire connection interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eParameter Ratings \u0026amp; Performance Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-OD6256-5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.095 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e8.95 cm x 3.0 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003eNone (0 inputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e32 PNP transistor outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003ePermitted Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e20.4 to 28.8 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eMax Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e0.5 A per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eSignal Processing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eFree running, Standard speed, Synchronous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003ePropagation Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eOFF to ON: 0.5 ms, ON to OFF: 1.0 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,0,0\"\u003eTerminal Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,1,0\"\u003e1-wire method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eSynchronous Backplane Bus \u0026amp; High-Density Execution\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe module interfaces directly with the internal NX bus to achieve deterministic signal processing synchronized with the CPU primary task period. High backplane bus communication velocity supports cycle-accurate output refreshes across all 32 PNP transistor channels simultaneously. Embedded firmware flash compatibility maintains consistent timing profiles across system updates, providing scalable I\/O density scaling while preserving isolation between logic and field power domains.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eShipment Box Contents\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-OD6256-5 Digital Output Slice Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Terminal Block Connector Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Module Installation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003ePanel Installation \u0026amp; Field Wiring Protocol\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSlice Assembly\u003c\/b\u003e: Align the side hooks of the NX module with the adjacent CPU or EtherCAT Coupler unit and slide until the internal bus connectors lock into engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003e1-Wire Connection\u003c\/b\u003e: Wire 24 VDC actuators directly to individual output terminals using 1-wire topology, connecting common reference lines to dedicated IO power distribution terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eConductor Specification\u003c\/b\u003e: Insert ferruled solid or stranded copper wires ranging from AWG 24 to AWG 16 into the push-in terminal slots for gas-tight contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eShield Grounding\u003c\/b\u003e: Keep low-voltage output cables physically separated from motor inverter leads and AC supply lines to prevent inductive noise pickup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eMaintenance \u0026amp; Diagnostic FAQ\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eWhat is the response delay time for the output channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eThe hardware propagation time measures 0.5 ms maximum for OFF-to-ON state switching and 1.0 ms maximum for ON-to-OFF state switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eDoes this module support hot-swapping on an active EtherCAT bus coupler?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eNo, removing or inserting the module requires powering down the local NX bus segment to prevent backplane communication errors or hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eHow are output loads powered across the 32 channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eField power is drawn from the I\/O power supply terminals routed through the NX bus or an auxiliary power supply unit, operating between 20.4 and 28.8 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eCan the outputs be synchronized with the master PLC execution cycle?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eYes, the module supports synchronous I\/O refreshing, locking state updates directly to the EtherCAT distributed clock and CPU primary task period.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat happens if an individual output channel experiences an overcurrent event?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eInternal protection circuits trip to isolate the fault, preventing damage to the internal transistor switches and reporting diagnostic flags to the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eIs external field power required for the PNP output drive circuit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eYes, 24 VDC field supply must be supplied via the NX bus power distribution rail or an additional NX-PF feed unit to power external loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eWhat wire terminal technology is used on the removable connector block?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eThe unit utilizes Push-In Plus spring-cage terminals, allowing tool-less direct wire insertion for vibration-resistant electrical connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eCan 2-wire or 3-wire field devices connect directly to this module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eBecause this module uses 1-wire connections, 2-wire and 3-wire loads require external common terminal blocks or additional power distribution units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306653892781,"sku":"NX-OD6256-5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-od6256-5_3_5.jpg?v=1790392973"},{"product_id":"nx-ec0132-omron-incremental-encoder-input-unit-nx-series","title":"NX-EC0132 Omron Incremental Encoder Input Unit NX Series","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron NX-EC0132\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-EC0132\u003c\/strong\u003e Incremental Encoder Input Unit, operates as a dedicated hardware component for high-speed differential position pulse counting within EtherCAT and Sysmac automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-EC0132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e130 g max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eStandard NX-series slice dimensions (12 mm x 100 mm x 71 mm approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 1.40 W (NX bus power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Form\u003c\/td\u003e\n\u003ctd\u003eLine receiver input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounter Signals\u003c\/td\u003e\n\u003ctd\u003ePhases A, B, and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Inputs\u003c\/td\u003e\n\u003ctd\u003e3 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (12 terminals x 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing, synchronous I\/O refreshing, or task period prioritized refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Unit\u003c\/td\u003e\n\u003ctd\u003ePulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration and Backplane Velocity\u003c\/h3\u003e\n\u003cp\u003eThe unit communicates directly via the NX-series backplane bus, transferring encoder pulse counts to the primary Motion Controller using deterministic EtherCAT network synchronization. Synchronous I\/O refreshing aligns encoder latching directly with the PLC task execution period, minimizing signal jitter during multi-axis motion profiling. Firmware flash compatibility ensures seamless configuration updates via Sysmac Studio without requiring hardware rewiring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDIN-Rail Mounting \u0026amp; Terminal Block Assembly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount vertically onto standard 35 mm DIN mounting rail alongside adjacent NX-series I\/O modules until the bus connectors lock into position.\u003c\/li\u003e\n\u003cli\u003eConnect field encoder signals to the push-in screwless clamping terminal block (12 terminals x 2 matrix) using ferrules or solid conductors stripped to 8-10 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eShielding \u0026amp; Line Receiver Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWire line receiver signals (Phases A, B, Z) using twisted-pair shielded cables to maintain differential signal noise immunity.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shield directly to the functional ground terminal on the NX bus support structure to prevent signal degradation from electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary Order Reference: NX-EC0132\u003c\/li\u003e\n\u003cli\u003eStandard Package Contents: 1x NX-EC0132 Incremental Encoder Input Unit, 2x 12-terminal screwless terminal blocks.\u003c\/li\u003e\n\u003cli\u003eCompatible Base Components: Omron NX-series Bus Coupler Unit (EtherCAT \/ EtherNet\/IP) or Sysmac CPU Unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Query Resolution\u003c\/h3\u003e\n\u003cp\u003eQ: Which encoder output driver types are supported on the NX-EC0132?\u003c\/p\u003e\n\u003cp\u003eA: The NX-EC0132 accepts differential line receiver input signals compliant with the RS-422A standard for high-speed pulse acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: How does synchronous I\/O refreshing benefit motion control processing?\u003c\/p\u003e\n\u003cp\u003eA: Synchronous I\/O refreshing synchronizes pulse counter reading with the EtherCAT network cycle and CPU task period, providing deterministic position feedback for axis positioning.\u003c\/p\u003e\n\u003cp\u003eQ: Are the external inputs configurable for latch functions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3 external inputs can be configured to trigger counter preset, latch, or reset commands in hardware with microsecond response times.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping allowed on the NX backplane during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement requires removing power from the NX bus power supply segment to prevent electrical transient damage across backplane contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306654056621,"sku":"NX-EC0132","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ec0132_1.jpg?v=1790393858"},{"product_id":"nx-od6121-5-omron-digital-output-module-nx-series","title":"NX-OD6121-5 Omron Digital Output Module NX-Series","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for high-density discrete load control in NX I\/O Bus architectures, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"83\"\u003eOmron NX-OD6121-5\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"102\"\u003eNX-OD6121\u003c\/b\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eModel Nomenclature \u0026amp; Structure Analysis\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe model string designates key structural and operational specifications for system integration:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Identifies the Omron modular I\/O platform architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eOD\u003c\/b\u003e: Denotes digital output functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e6121\u003c\/b\u003e: Indicates high-density 32-point capacity with NPN switching logic and 1-wire connection scheme.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e5\u003c\/b\u003e: Specifies standard speed processing with synchronous execution capability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eModule Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"9\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,1,0\"\u003eNX-OD6121-5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,1,0\"\u003e0.090 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,0,0\"\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,1,0\"\u003e1.000 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,0,0\"\u003ePhysical Dimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,1,0\"\u003e8.95 cm x 3.00 cm x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,1,0\"\u003e15.00 cm x 8.00 cm x 12.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,0,0\"\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,1,0\"\u003eDigital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,0,0\"\u003eI\/O System Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,1,0\"\u003eNX I\/O Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,10,0,0\"\u003eNumber of Digital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,10,1,0\"\u003e32 points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,11,0,0\"\u003eDigital Output Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,11,1,0\"\u003eNPN transistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,12,0,0\"\u003ePermitted Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,12,1,0\"\u003e15.0 to 28.8 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,13,0,0\"\u003eMax Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,13,1,0\"\u003e0.5 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,14,0,0\"\u003eOutput Connection Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,14,1,0\"\u003e1-wire Push-In Plus terminal block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,15,0,0\"\u003eSignal Processing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,15,1,0\"\u003eFree running, Standard speed, Synchronous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,16,0,0\"\u003eTurn-ON \/ Turn-OFF Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,16,1,0\"\u003e0.1 to 0.8 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,17,0,0\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,17,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,18,0,0\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,18,1,0\"\u003e-25 to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,19,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,19,1,0\"\u003e0.85 W max (from NX Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eIndustrial Bus Execution \u0026amp; Deterministic Synchronization\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe NX-OD6121-5 interfaces directly with the internal NX I\/O Bus to execute low-jitter output switching across high-density transistor outputs. The unit supports deterministic network synchronization, aligning output state transitions with the EtherCAT master cycle time. Internal hardware pathways optimize backplane bus communication velocity and I\/O density scaling, enabling accurate cyclic execution across demanding PLC and motion control networks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003ePackage Contents \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e1 x Omron NX-OD6121-5 Digital Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e1 x Attached Push-In Plus terminal block assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e1 x Hardcopy installation instruction sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eInstallation \u0026amp; Wiring Framework\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eMount the unit directly onto a standard 35 mm DIN rail until the locking latch engages securely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eRemove field power supplies before connecting or disconnecting push-in wire leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003eStrip 10 mm of insulation from 24 AWG to 16 AWG solid or ferruled conductors for toolless insertion into the Push-In Plus terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003eEnsure proper grounding of the DIN rail to prevent common-mode noise propagation across the digital switching transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,4,0\"\u003eMaintain physical separation between output signal lines and heavy inductive load power conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eSystem Integration FAQ\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eDoes the NX-OD6121-5 module support hot-swapping on the backplane during operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,0,1\"\u003eNo, power to the NX I\/O Bus and field power supply must be disconnected before removing or inserting the module to prevent electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eWhat is the maximum continuous output current permitted per individual channel?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,1,1\"\u003eEach NPN channel supports a maximum current load of 0.5 A across the permitted 15.0 to 28.8 VDC operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eWhat connection topology does the terminal block use for field wiring?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,2,1\"\u003eThe module utilizes a 1-wire Push-In Plus terminal connection scheme for compact high-density signal distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eHow does the output switching delay perform under standard operating conditions?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,3,1\"\u003eThe hardware transition OFF\/ON and ON\/OFF propagation delays range strictly between 0.1 ms and 0.8 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eCan the digital outputs switch AC voltage loads directly?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,4,1\"\u003eNo, the transistor switching elements are rated exclusively for DC voltage circuits operating between 15.0 VDC and 28.8 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003eWhat signal processing modes are configurable on this digital module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,5,1\"\u003eThe hardware supports Free Running, Standard Speed, and Synchronous processing modes via system configuration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eIs external field power required to drive the output switching circuits?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,6,1\"\u003eYes, an external 24 VDC field power source must be provided to feed the NPN load switching circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eHow is the physical ground reference maintained across the module interface?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,7,1\"\u003eGround continuity is established through the integrated DIN rail grounding contact points on the module housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306654089389,"sku":"NX-OD6121-5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-od6121-5_1.jpg?v=1790690016"},{"product_id":"omron-cj1w-nc233-position-control-unit-cj1-series","title":"Omron CJ1W-NC233 Position Control Unit CJ1 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-NC233\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-NC233\u003c\/strong\u003e Position Control Unit, operates as a dedicated hardware component for multi-axis motion generation via line-driver pulse outputs within CJ1 PLC networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Omron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e CJ1W-NC233\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-NC233\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e CJ1 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Category:\u003c\/strong\u003e CJ1 Special I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllocated Unit Numbers:\u003c\/strong\u003e 1 Unit Number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-NC233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C ... +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (5 V)\u003c\/td\u003e\n\u003ctd\u003e0.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (24 V)\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Control Axes\u003c\/td\u003e\n\u003ctd\u003e2 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eOpen-loop control by pulse train output \/ Line-driver output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Unit Type\u003c\/td\u003e\n\u003ctd\u003eCJ1 Special I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-NC233 interfaces directly with the CJ1 backplane bus to transfer high-speed motion commands from the CPU to external servo drivers and stepper drives. Utilizing 1 allocated Special I\/O unit number, the module draws 0.25 A at 5 VDC from the backplane without requiring an auxiliary 24 VDC bus supply. The unit generates high-frequency line-driver pulse trains across 2 independent control axes, maintaining strict backplane determinism and predictable pulse frequency scaling under open-loop control configurations.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-NC233 Position Control Unit\u003c\/li\u003e\n\u003cli\u003e1x CJ1 Unit Connector Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Lock the module directly onto the CJ1 CPU or expansion rack backplane bus connector using the top and bottom slider catches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect line-driver pulse train output lines to external servo or stepper drives using twisted-pair shielded cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Terminate line-driver signal cabling with 360-deg braid shielding connected to the chassis ground bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure the rack mounting surface to functional earth (FE) using a dedicated low-impedance conductor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control method is implemented by the CJ1W-NC233 position control unit?\u003c\/p\u003e\n\u003cp\u003eThe module utilizes open-loop control via pulse train outputs over differential line-driver circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many motion axes can the CJ1W-NC233 control simultaneously?\u003c\/p\u003e\n\u003cp\u003eThe module provides dedicated output interface logic to control up to 2 independent axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the internal current consumption specifications from the backplane?\u003c\/p\u003e\n\u003cp\u003eThe unit draws 0.25 A from the 5 VDC backplane bus and requires 0.00 A (None) from any 24 VDC line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many unit numbers are allocated on the CJ1 CPU rack?\u003c\/p\u003e\n\u003cp\u003eThe hardware occupies exactly 1 Special I\/O unit number space within the CJ1 system memory map.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical dimensions apply to the CJ1W-NC233 hardware module?\u003c\/p\u003e\n\u003cp\u003eThe standard unit physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with an overall module weight of 1.2 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-NC233 support internal closed-loop encoder feedback processing?\u003c\/p\u003e\n\u003cp\u003eNo, the unit executes open-loop position control via differential line-driver pulse outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding standard must be maintained for pulse train signal lines?\u003c\/p\u003e\n\u003cp\u003eField wiring requires twisted-pair cabling encased in 360-deg braid shielding bonded to functional earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating temperature envelope is sustained by the unit chassis?\u003c\/p\u003e\n\u003cp\u003eThe hardware operates reliably across an ambient temperature envelope of 0 deg C ... +55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306655498413,"sku":"CJ1W-NC233","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-NC233_2.jpg?v=1788159875"},{"product_id":"omron-cj1w-eip21-cj-series-ethernet-ip-unit","title":"Omron CJ1W-EIP21 CJ Series EtherNet\/IP Unit","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-EIP21\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-EIP21\u003c\/strong\u003e EtherNet\/IP Unit, operates as a dedicated Ethernet communication interface for cyclic and message-based data exchange between CJ-series controllers and EtherNet\/IP devices. The unit is classified as a CJ-series CPU Bus Unit and supports 100BASE-TX communication at 100 Mbit\/s over a star topology.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-EIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCJ-series EtherNet\/IP Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Classification\u003c\/td\u003e\n\u003ctd\u003eCJ-series CPU Bus Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Access Method\u003c\/td\u003e\n\u003ctd\u003eCSMA\/CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Method\u003c\/td\u003e\n\u003ctd\u003eBaseband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Path\u003c\/td\u003e\n\u003ctd\u003eStar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n\u003ctd\u003e100 m between hub and node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eCPU Rack or Expansion Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNJ-series Maximum Units\u003c\/td\u003e\n\u003ctd\u003e4 units, including Expansion Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJ-series \/ NSJ-series Maximum Units\u003c\/td\u003e\n\u003ctd\u003e8 units, including Expansion Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCP1H Maximum Units\u003c\/td\u003e\n\u003ctd\u003e2 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e410 mA max. at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 6.5 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.094 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-EIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Classification\u003c\/td\u003e\n\u003ctd\u003eCPU Bus Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Access Method\u003c\/td\u003e\n\u003ctd\u003eCSMA\/CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation\u003c\/td\u003e\n\u003ctd\u003eBaseband\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eStar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Node Distance\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eCPU Rack or Expansion Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNJ-series Mounting Limit\u003c\/td\u003e\n\u003ctd\u003e4 units max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJ \/ NSJ-series Mounting Limit\u003c\/td\u003e\n\u003ctd\u003e8 units max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCP1H Mounting Limit\u003c\/td\u003e\n\u003ctd\u003e2 units max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e410 mA max. at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.05 W at maximum 5 VDC current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 6.5 cm x 9.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified by the provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.094 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Communication and CJ CPU Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-EIP21 operates as a CPU Bus Unit rather than as a conventional Basic I\/O Unit. Its communication processing therefore interfaces with the CJ-series CPU through the CPU Bus architecture while providing EtherNet\/IP network connectivity.\u003c\/p\u003e\n\u003cp\u003eThe 100BASE-TX interface provides a nominal transmission rate of 100 Mbit\/s. The specified maximum cable distance between a hub and node is 100 m. Network installation should maintain the Ethernet physical-layer requirements for twisted-pair cabling, connector termination, and electromagnetic compatibility.\u003c\/p\u003e\n\u003cp\u003eThe unit can be mounted on either a CPU Rack or Expansion Rack. The allowable number of mounted EtherNet\/IP Units depends on the host controller family, with different limits specified for NJ-series, CJ\/NSJ-series, and CP1H systems.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-EIP21 EtherNet\/IP Unit\u003c\/li\u003e\n\u003cli\u003e1x CJ-series CPU Bus Unit\u003c\/li\u003e\n\u003cli\u003eNetwork cable and external Ethernet connection hardware are not assumed unless specifically included with the supplied unit\u003c\/li\u003e\n\u003cli\u003eMounting and rack hardware are installed as part of the applicable CJ-series rack configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CJ1W-EIP21 only in a compatible CJ-series CPU Rack or Expansion Rack configuration.\u003c\/li\u003e\n\u003cli\u003eVerify the permitted CPU Bus Unit count for the specific controller before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the PLC configuration recognizes the installed CPU Bus Unit.\u003c\/li\u003e\n\u003cli\u003eUse 100BASE-TX-compatible twisted-pair Ethernet cabling for the network connection.\u003c\/li\u003e\n\u003cli\u003eKeep the Ethernet cable route separated from high-current motor, inverter, contactor, and switching-power wiring where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain the maximum specified 100 m distance between a hub and the connected node.\u003c\/li\u003e\n\u003cli\u003eUse a suitable Ethernet switch or hub for the required star network topology.\u003c\/li\u003e\n\u003cli\u003eEnsure RJ45 connectors are correctly terminated and mechanically secured.\u003c\/li\u003e\n\u003cli\u003eDo not route communication cables through areas with excessive electromagnetic interference without appropriate cable-management and shielding measures.\u003c\/li\u003e\n\u003cli\u003eGround the PLC rack and associated equipment according to Omron installation requirements and the site's protective-grounding system.\u003c\/li\u003e\n\u003cli\u003eVerify the 5 VDC CPU Bus Unit power budget because the module can consume up to 410 mA.\u003c\/li\u003e\n\u003cli\u003eDo not assume hot-swapping capability unless explicitly permitted by the applicable CJ-series hardware documentation.\u003c\/li\u003e\n\u003cli\u003eConfirm network configuration and node parameters before placing the EtherNet\/IP network into operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Ethernet speed does the CJ1W-EIP21 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CJ1W-EIP21 provides 100BASE-TX communication at 100 Mbit\/s. Its physical Ethernet interface uses baseband transmission with CSMA\/CD media access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum transmission distance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Omron specifies a maximum transmission distance of 100 m between the Ethernet hub and node. Actual installation must also comply with the selected cable and network equipment specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where can the CJ1W-EIP21 be mounted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit can be installed on either a CPU Rack or Expansion Rack. The permissible number of CPU Bus Units depends on the host controller system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How much 5 VDC current does the unit consume?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified maximum internal current consumption is 410 mA at 5 VDC. This corresponds to approximately 2.05 W for the CPU Bus Unit power calculation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many CJ1W-EIP21 units can be installed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The maximum is system-dependent: 4 units for an NJ-series system, 8 units for CJ\/NSJ systems, and 2 units for a CP1H system, including Expansion Racks where applicable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What network topology is specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified transmission path is a star form. A suitable Ethernet hub or switch is therefore used to connect the CJ1W-EIP21 with other network nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the physical dimensions of the CJ1W-EIP21?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified dimensions are 3.1 cm x 6.5 cm x 9.0 cm. The supplied unit weight is approximately 0.094 kg, excluding external packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CJ1W-EIP21 a Basic I\/O Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The CJ1W-EIP21 is classified as a CJ-series CPU Bus Unit. It communicates with the PLC CPU through the CPU Bus architecture rather than occupying Basic I\/O allocation as a discrete I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306656678061,"sku":"CJ1W-EIP21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-EIP21_2.jpg?v=1788155782"},{"product_id":"nx-ad3608-omron-analog-input-unit-nx-series","title":"NX-AD3608 Omron Analog Input Unit NX Series","description":"\u003cp\u003eConfigured for high-speed differential voltage measurement in Sysmac automation platforms, the \u003cstrong\u003eOmron NX-AD3608\u003c\/strong\u003e (\u003cstrong\u003eNX-AD3608\u003c\/strong\u003e Analog Input Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eOrdering Code \u0026amp; Nomenclature Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model number \u003cstrong\u003eNX-AD3608\u003c\/strong\u003e follows the standard Omron NX Series module categorization schema:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Identifies the modular I\/O product line for Sysmac controllers and EtherCAT couplers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAD\u003c\/strong\u003e: Analog Input unit classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: 4-point input capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\u003c\/strong\u003e: Input voltage range configured for -10 to +10 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e08\u003c\/strong\u003e: High-resolution performance variant (1\/30000 resolution, 10 us\/point conversion speed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-AD3608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12 (W) x 100 (H) x 71 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.45 W max. (CPU\/Communication Control Unit), 1.10 W max. (Coupler Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4 differential points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V (Input conversion range: -5 to 105% full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/30000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e10 us\/point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1 Mohm min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e+\/-15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% full scale at 25 deg C; +\/-0.2% full scale from 0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Refreshing Method\u003c\/td\u003e\n\u003ctd\u003eSwitching synchronous I\/O refreshing and Free-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (12 terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eTransformer (Power), Digital isolator (Signal) between input and NX bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm min. between isolated circuits at 100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e510 VAC between isolated circuits for 1 min (leakage current 5 mA max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Speed Deterministic Network Performance\u003c\/h3\u003e\n\u003cp\u003eThe NX-AD3608 integrates directly into high-density industrial control topologies utilizing EtherCAT deterministic networks. Internal signal processing maintains a conversion cycle speed of 10 us per point, allowing synchronized I\/O refreshing aligned with the master controller task cycle. High-speed backplane bus communication velocity enables jitter-free data transfer to the CPU, while firmware flash compatibility maintains consistent parameter configuration across Sysmac Studio software revisions.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-AD3608 Analog Input Unit\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block unit (12-pin screwless clamp type, pre-installed)\u003c\/li\u003e\n\u003cli\u003e1 x Instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting Position: Secure the module onto a standard 35 mm DIN rail by snapping the rear locking mechanism into position until an audible click is heard.\u003c\/li\u003e\n\u003cli\u003eWiring Method: Insert solid wires or stranded wires with insulated copper ferrules directly into the 12-terminal screwless clamping block. Use a flat-blade screwdriver to depress the release button when removing conductors.\u003c\/li\u003e\n\u003cli\u003eShielding \u0026amp; Grounding: Connect shielded differential input cables to prevent electromagnetic interference from surrounding drive equipment. Maintain single-point shield grounding at the panel side.\u003c\/li\u003e\n\u003cli\u003ePower Isolation: The module operates without consuming I\/O power supply current, but requires proper functional grounding on the connected CPU or Coupler unit DIN rail clip.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum absolute input voltage limit for the NX-AD3608?\u003c\/p\u003e\n\u003cp\u003eThe module tolerates a continuous maximum voltage of +\/-15 V across its differential input terminals without causing internal hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX-AD3608 provide channel-to-channel isolation between inputs?\u003c\/p\u003e\n\u003cp\u003eNo, isolation is provided between the input circuits and the internal NX bus, but there is no electrical isolation between individual input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat I\/O refreshing modes are supported by this unit?\u003c\/p\u003e\n\u003cp\u003eThe unit supports both synchronous I\/O refreshing (synchronized with the master execution cycle) and Free-Run refreshing modes depending on system requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are field wires terminated on the front interface?\u003c\/p\u003e\n\u003cp\u003eField connections utilize a removable 12-pin screwless push-in clamping terminal block that accepts solid wires or ferruled stranded conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the overall measurement accuracy across the full operational temperature range?\u003c\/p\u003e\n\u003cp\u003eAccuracy is rated at +\/-0.1% of full scale at 25 deg C, and +\/-0.2% of full scale across the full operating range of 0 to 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module draw power from the connected I\/O power supply bus?\u003c\/p\u003e\n\u003cp\u003eNo, the NX-AD3608 features no I\/O power supply terminals and draws power exclusively from the internal NX bus (1.45 W max on CPU units).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input conversion speed per analog channel?\u003c\/p\u003e\n\u003cp\u003eThe internal analog-to-digital converter processes signals at a speed of 10 us per point with a total internal resolution of 1\/30000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of isolation is used between the inputs and the NX bus?\u003c\/p\u003e\n\u003cp\u003ePower is isolated via transformer coupling, while signal lines are isolated using high-speed digital isolator components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306657398957,"sku":"NX-AD3608","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-ad3608-1.jpg?v=1790659423"},{"product_id":"cj1w-nc113-omron-position-control-unit-cj-series","title":"CJ1W-NC113 Omron Position Control Unit CJ-series","description":"\u003cp\u003eConfigured for open-loop single-axis pulse train motion execution in CJ-series PLC systems, the \u003cstrong\u003eOmron CJ1W-NC113\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-NC113\u003c\/strong\u003e Position Control Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration and Variant Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-NC113\u003c\/strong\u003e occupies a single Special I\/O Unit slot on the CJ-series CPU rack or expansion rack. Its part numbering hierarchy reflects system allocation parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJ1W\u003c\/strong\u003e: Dedicated I\/O module platform designed for CJ1G, CJ1M, CJ2M, and CJ2H PLC backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNC\u003c\/strong\u003e: Motion control designation indicating direct pulse train generation for stepper or servo driver command inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e113\u003c\/strong\u003e: Structural designator representing a single-axis hardware channel (\"1\") utilizing open-collector output circuitry (\"13\").\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Number Allocation\u003c\/strong\u003e: Consumes 1 Special I\/O Unit slot address (set via the front-panel rotary switch from 0 to 95).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Physical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-NC113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Type\u003c\/td\u003e\n\u003ctd\u003eCJ1 Special I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eOpen-loop control via pulse train \/ Open-collector output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Control Axes\u003c\/td\u003e\n\u003ctd\u003e1 axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e0.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirement (24 VDC)\u003c\/td\u003e\n\u003ctd\u003eNone (Internal 5 VDC backplane bus power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 130 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; Deterministic I\/O Bus Execution\u003c\/h3\u003e\n\u003cp\u003eThe module communicates directly across the CJ-series local backplane bus, transferring control words, target positioning addresses, and pulse frequency profiles between CPU memory and hardware registers. High-density I\/O routing prevents firmware flash buffer underruns during fast acceleration curves. Internal field-effect isolation protects logic circuitry from electrical noise on the open-collector output lines.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-NC113 Single-Axis Position Control Unit\u003c\/li\u003e\n\u003cli\u003e1 x High-density 18-pin terminal block connector assembly\u003c\/li\u003e\n\u003cli\u003e1 x Hardware installation sheet and panel earth strap guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControl Panel Installation Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Slot Alignment\u003c\/strong\u003e: Power off the rack before inserting the module into the CJ-series backplane. Engage upper and lower mounting catches until locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-Collector Shielding\u003c\/strong\u003e: Route output pulse and direction cables in shielded twisted-pair wire, segregated from 230 VAC\/480 VAC motor power lines by at least 200 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol\u003c\/strong\u003e: Connect the drain wire of shielded cables to a single-point panel ground with a ground impedance lower than 100 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Termination\u003c\/strong\u003e: Ensure external power supplies powering pulse collector loops do not exceed 24 VDC voltage parameters to avoid thermal damage to collector transistors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the unit address configured on the module hardware?\u003c\/p\u003e\n\u003cp\u003eSet the front-panel rotary switch to an unallocated number between 0 and 95 prior to powering on the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-NC113 require an external 24 VDC power supply to operate internal logic?\u003c\/p\u003e\n\u003cp\u003eNo. The internal logic draws 0.25 A directly from the 5 VDC PLC backplane supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal configuration is supported by this hardware?\u003c\/p\u003e\n\u003cp\u003eThe unit features open-collector outputs suitable for driving line receivers or optocouplers on motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit be removed while the CJ-series PLC CPU is running?\u003c\/p\u003e\n\u003cp\u003eNo. Hot-swapping Special I\/O modules on a live CJ1 backplane will cause a bus fault and stop system execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the output pulse frequency command exceeds hardware limits?\u003c\/p\u003e\n\u003cp\u003eThe module flags an instruction error register in PLC memory and inhibits pulse transmission to the drive interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs differential line driver wiring supported on the output terminal?\u003c\/p\u003e\n\u003cp\u003eNo. The CJ1W-NC113 is limited to open-collector switching. Use differential units for long-distance signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many unit numbers does the CJ1W-NC113 consume in memory allocation?\u003c\/p\u003e\n\u003cp\u003eThe module consumes exactly 1 Special I\/O unit number within the PLC allocation table.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable length restriction applies to the open-collector outputs?\u003c\/p\u003e\n\u003cp\u003eKeep pulse command cabling under 2 meters to limit signal degradation and electromagnetic noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306659627181,"sku":"CJ1W-NC113","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-NC113_1.jpg?v=1788156364"},{"product_id":"cj1w-da021-omron-analog-output-unit-cj-series","title":"CJ1W-DA021 Omron Analog Output Unit CJ Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-DA021\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCJ1W-DA021\u003c\/strong\u003e Analog Output Unit, operates as a dedicated hardware component for digital-to-analog signal conversion and process control variable generation within CJ Series PLC backplanes.\u003c\/p\u003e\n\u003ch3\u003eProduct Designation \u0026amp; Architecture Analysis\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-DA021\u003c\/strong\u003e occupies a single slot on CJ1G, CJ1M, CJ2M, or CJ2H CPU bus racks. Its standardized model structure highlights specific operational capabilities:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJ1W\u003c\/strong\u003e: Dedicated I\/O module system platform for Omron CJ Series programmable controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDA\u003c\/strong\u003e: Digital-to-Analog hardware architecture designed for field voltage and current loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e021\u003c\/strong\u003e: Functional designator indicating 2 analog output channels with a 1\/4,000 resolution profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Bus Interface\u003c\/strong\u003e: Photocoupler isolation separates internal PLC controller signals from field wiring side circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Hardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-DA021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, 4 to 20 mA, 0 to 5 V, 0 to 10 V, -10 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e1\/4,000 (16-bit binary conversion data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e1.0 ms per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy (25 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +-0.3% of F.S. \/ Current: +-0.5% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy (0 to 55 deg C)\u003c\/td\u003e\n\u003ctd\u003eVoltage: +-0.5% of F.S. \/ Current: +-0.8% of F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance (Voltage)\u003c\/td\u003e\n\u003ctd\u003e0.5 ohm max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current (Voltage)\u003c\/td\u003e\n\u003ctd\u003e12 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Load Resistance (Current)\u003c\/td\u003e\n\u003ctd\u003e600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (Internal Bus)\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 120 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+10% \/ -15%), 140 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Inrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A max., pulse width 1 ms min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Structure\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler between I\/O and PLC logic (No channel-to-channel isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 11.0 cm x 8.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Synchronization \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module streams converted analog variables over the high-speed local backplane bus without requiring additional CPU polling cycles. Internal bus communication velocity guarantees rapid data write commands directly from allocated memory words to the digital-to-analog converter. Scaling algorithms adjust firmware register values in real time to sustain deterministic loop output states under dynamic processing loads.\u003c\/p\u003e\n\u003ch3\u003eStandard Module Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-DA021 Analog Output Unit\u003c\/li\u003e\n\u003cli\u003e1 x 18-point detachable terminal block with M3 screw terminals\u003c\/li\u003e\n\u003cli\u003e1 x Hardware mounting instruction manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Termination \u0026amp; Wiring Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screw Torque\u003c\/strong\u003e: Tighten all M3 terminal block screws to a torque rating of 0.5 N m to ensure secure connection without stripping threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Wiring\u003c\/strong\u003e: Wire an independent, regulated 24 VDC external power supply to the terminal block to supply output driver circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Protocol\u003c\/strong\u003e: Use twisted-pair shielded cables for all analog voltage and current loops. Ground the shield at the module panel earth side only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Separation\u003c\/strong\u003e: Keep analog signal cables separated from AC power lines and high-frequency inverter outputs by a minimum distance of 300 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes the output voltage or current to freeze when the CPU enters STOP mode?\u003c\/p\u003e\n\u003cp\u003eThe module's hold function is configured to maintain the last valid converted value. Change the memory setting to CLEAR if zero output is required during CPU stop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan channel 1 operate in 4-20 mA mode while channel 2 operates in -10 to 10 V mode?\u003c\/p\u003e\n\u003cp\u003eYes. Each analog channel is individually configured in system memory for specific voltage or current signal ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs channel-to-channel isolation supported on the CJ1W-DA021 terminal block?\u003c\/p\u003e\n\u003cp\u003eNo. Photocoupler isolation exists between field circuits and the backplane logic, but there is no electrical isolation between individual output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is external 24 VDC power connected to the unit?\u003c\/p\u003e\n\u003cp\u003eExternal 24 VDC power must be wired directly to the designated terminals on the 18-point detachable terminal block to power the internal output stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-DA021 support hot-swapping while the rack is powered?\u003c\/p\u003e\n\u003cp\u003eNo. Removing or inserting the unit while the CJ Series backplane is energized can damage module electronics and fault the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response time for both analog output channels to update?\u003c\/p\u003e\n\u003cp\u003eThe total D\/A conversion cycle time is 1.0 ms per point, resulting in a total update period of 2.0 ms for both active output points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat load resistance limits apply when using the 4-20 mA current output range?\u003c\/p\u003e\n\u003cp\u003eThe connected load impedance must not exceed 600 ohms per current output channel to maintain calibrated signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the external 24 VDC power supply drops below operating limits?\u003c\/p\u003e\n\u003cp\u003eThe module stops outputting current\/voltage signals, flags a power supply alarm in the PLC status words, and forces outputs to 0 V or 0 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306659758253,"sku":"CJ1W-DA021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-DA021_1_ba0fe8de-7c84-4731-98f6-99c505273096.jpg?v=1788155355"},{"product_id":"nx-da3205-omron-nx-series-analog-i-o-unit","title":"NX-DA3205 Omron NX Series Analog I\/O Unit","description":"\u003ch1 data-path-to-node=\"0\"\u003eOmron NX-DA3205 Analog I\/O Unit NX Series\u003c\/h1\u003e\n\u003ch1 data-path-to-node=\"1\"\u003eNX-DA3205 Omron Analog I\/O Unit NX Series\u003c\/h1\u003e\n\u003ch1 data-path-to-node=\"2\"\u003eNX-DA3205 Omron NX Series Analog I\/O Unit\u003c\/h1\u003e\n\u003ch1 data-path-to-node=\"3\"\u003eOmron NX-DA3205 NX Series Analog I\/O Unit\u003c\/h1\u003e\n\u003cp data-path-to-node=\"4\"\u003eConfigured for high-speed current signal output in NX I\/O Bus architectures, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"81\"\u003eOmron NX-DA3205\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"98\"\u003eNX-DA3205\u003c\/b\u003e) Analog I\/O Unit provides direct physical\/electrical execution. It operates with a fast conversion rate of 0.04 ms per unit across 4 dedicated analog output channels. Utilizing Push-in Plus terminal connections, the module processes 4 to 20 mA linear output signals synchronously to ensure deterministic control timing without requiring analog inputs or specialized temperature sensing circuits.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Product series designation for Omron modular I\/O system backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eDA\u003c\/b\u003e: Analog Output Unit classification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e3\u003c\/b\u003e: 4-channel capacity per module interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e2\u003c\/b\u003e: 1\/12000 high-resolution performance tier (15-bit representation).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003e05\u003c\/b\u003e: Linear current range profile (4 to 20 mA range output).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-DA3205\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.07 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e1.2 cm x 7.1 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e1.45 W max (via NX bus supply)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003eAnalog Output Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eNumber of Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e4 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eLinear Output Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e15 Bit (1\/12000 full scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eConversion Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003e0.04 ms\/unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003eSignal Processing Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eSynchronous I\/O refreshing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,0,0\"\u003eTerminal Connection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,1,0\"\u003ePush-in Plus (1 connector)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,15,0,0\"\u003eIP Protection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,15,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDeterministic Bus Performance\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe module leverages synchronous signal processing over the NX I\/O Bus to eliminate jitter during output signal updates. By coupling high-speed backplane bus communication velocity with a 0.04 ms update time per unit, output loops remain fully synchronized with EtherCAT master control cycles. Channel-to-channel signal propagation avoids timing skew, making the unit suitable for multi-axis or tight motion-servo feedback applications. Integrated firmware maintains output integrity and deterministic state execution during backplane refresh cycles.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003ePackage \u0026amp; Ordering Content\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-DA3205 Analog Output Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Push-in Plus Terminal Block (16-pin integrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Standard Hardware Installation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eMechanical Mounting \u0026amp; Wire Setup\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eDIN Rail Fitting\u003c\/b\u003e: Engage the top rear notch of the module onto a standard 35 mm DIN rail, then press firmly until the locking lever clicks into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003ePush-in Wire Termination\u003c\/b\u003e: Strip solid or ferruled stranded wires to 10 mm. Insert directly into the Push-in terminal holes without tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eWire Extraction\u003c\/b\u003e: Press the release button using a flat-blade screwdriver while pulling the wire out straight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eShielding \u0026amp; Grounding\u003c\/b\u003e: Ground the shield wire at the ground terminal of the NX bus setup to prevent electromagnetic interference on the 4-20 mA loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eWiring Separation\u003c\/b\u003e: Route output signal wires away from high-voltage power lines and motor drive cables in a separate conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFAQs\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eIs the NX-DA3205 unit hot-swappable during active bus operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eNo. You must turn off the power supply to the CPU unit, expansion unit, and the NX I\/O bus before installing or removing the module to prevent electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eWhat happens to the 4 to 20 mA outputs if backplane communication fails?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eOutputs transition to a pre-configured fail-safe state (either holding last value or dropping to 0 mA \/ lower limit) according to the CPU configuration settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eDoes the module require an external power supply for loop current?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eInternal circuits run on NX bus power, but external 24 VDC power must be wired to the I\/O power terminals to drive the 4 to 20 mA output loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eWhat is the total conversion time when all 4 channels are enabled?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eThe conversion time remains 0.04 ms per unit due to simultaneous internal sampling and synchronous refresh execution across channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat wire gauge sizes fit the Push-in Plus terminal block?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eThe terminal block accepts solid or stranded cables with ferrules ranging from 0.25 mm2 to 1.5 mm2 (AWG 24 to 16).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eCan this unit handle voltage output signals like 0 to 10 VDC?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eNo. The NX-DA3205 is strictly hardwired for linear current signals in the 4 to 20 mA range and cannot generate voltage outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eHow does synchronous I\/O processing benefit the control system?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eIt synchronizes analog output updates directly with the EtherCAT cycle time, eliminating timing variation between the controller and end devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eDoes the NX-DA3205 provide channel-to-channel isolation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eNo. Isolation exists between the NX bus and the I\/O signals, but individual channels share a common ground reference internally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306662674605,"sku":"NX-DA3205","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-DA3205-1.jpg?v=1790227506"},{"product_id":"omron-cj1w-id261-cj-series-64-point-dc-input-unit","title":"Omron CJ1W-ID261 CJ Series 64-point DC Input Unit","description":"\u003cp\u003eConfigured for 24 VDC discrete signal acquisition in CJ-series PLC systems, the \u003cstrong\u003eOmron CJ1W-ID261\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-ID261\u003c\/strong\u003e DC Input Unit) provides 64 digital input channels through two 40-pin Fujitsu\/OTAX-compatible connectors. The unit uses four 16-point common circuits, allocates 4 words, and accepts both NPN and PNP input devices when the same polarity is maintained within each common circuit. Omron specifies 4.1 mA typical input current and 90 mA maximum 5 VDC internal current consumption.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCJ1 64-point DC Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Category\u003c\/td\u003e\n\u003ctd\u003eBasic I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eDC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e5.6 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Configuration\u003c\/td\u003e\n\u003ctd\u003e16 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e64 inputs, 4 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eFujitsu \/ OTAX-compatible connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e40-pin x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWords Allocated\u003c\/td\u003e\n\u003ctd\u003e4 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Polarity\u003c\/td\u003e\n\u003ctd\u003eNPN or PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA max. at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eOmron's official specification lists the CJ1W-ID261 as a 64-point, 24 VDC input unit with Fujitsu\/OTAX-compatible connectors and 4 allocated words.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-ID261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital DC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCJ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e5.6 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage\u003c\/td\u003e\n\u003ctd\u003e19.0 VDC min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Current\u003c\/td\u003e\n\u003ctd\u003e3 mA min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Current\u003c\/td\u003e\n\u003ctd\u003e1 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Response Time\u003c\/td\u003e\n\u003ctd\u003e8.0 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Response Time\u003c\/td\u003e\n\u003ctd\u003e8.0 ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Filter\u003c\/td\u003e\n\u003ctd\u003e0 to 32 ms configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Arrangement\u003c\/td\u003e\n\u003ctd\u003e16 points\/common, 4 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneously ON Points\u003c\/td\u003e\n\u003ctd\u003e50% at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. at 100 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA max. at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.45 W max. at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified by Omron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe CJ-series dimensional documentation identifies CJ1W-ID261 under the 64-point input units with two 40-pin Fujitsu\/OTAX-compatible connectors. The CJ-series unit dimensions are 31 mm x 90 mm x 65 mm, corresponding to 3.1 cm x 9.0 cm x 6.5 cm.\u003c\/p\u003e\n\u003ch3\u003eOmron PLC I\/O Architecture and Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-ID261 is a high-density Basic I\/O Unit for the Omron CJ-series controller architecture. Its 64 inputs are divided into four 16-point common groups. The unit occupies 4 CIO words in the PLC I\/O allocation.\u003c\/p\u003e\n\u003cp\u003eThe 24 VDC input circuit uses a 5.6 kOhm input impedance and draws 4.1 mA typical per input at the rated voltage. The specified ON threshold is 19.0 VDC minimum, while the OFF threshold is 5 VDC maximum.\u003c\/p\u003e\n\u003cp\u003eOmron specifies compatibility with both NPN and PNP output devices for its 24 VDC CJ-series input models. The same polarity must be used for devices connected to inputs sharing a common. A configurable digital filter from 0 to 32 ms is provided for suppression of unwanted external signal transitions.\u003c\/p\u003e\n\u003cp\u003eThe 50% simultaneous ON specification corresponds to 8 active input points within each 16-point common circuit at 24 VDC. This limitation should be considered when calculating field-device loading and input signal distribution.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-ID261 DC Input Unit\u003c\/li\u003e\n\u003cli\u003e1x CJ1W-ID261 64-point Basic I\/O Unit\u003c\/li\u003e\n\u003cli\u003e2x 40-pin Fujitsu \/ OTAX-compatible external connector interfaces\u003c\/li\u003e\n\u003cli\u003eExternal connector plugs are not included as standard accessories\u003c\/li\u003e\n\u003cli\u003eTerminal-block conversion hardware is available separately for compatible CJ-series I\/O configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOmron lists the standard accessories for CJ1W-ID261 as none.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CJ1W-ID261 in a compatible CJ-series PLC rack and verify the CPU and backplane configuration before energization.\u003c\/li\u003e\n\u003cli\u003eConfirm that the unit is assigned the required 4 words in the CJ I\/O allocation.\u003c\/li\u003e\n\u003cli\u003eSupply field input circuits with 24 VDC within the specified 20.4 to 26.4 VDC range.\u003c\/li\u003e\n\u003cli\u003eConnect field devices through the two 40-pin Fujitsu\/OTAX-compatible interfaces.\u003c\/li\u003e\n\u003cli\u003eMaintain the same NPN or PNP polarity for inputs belonging to the same common circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified simultaneous ON loading for each 16-point common group.\u003c\/li\u003e\n\u003cli\u003eKeep discrete signal wiring physically separated from high-current motor, contactor, inverter, and switching-power wiring where practical.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cable shielding and grounding when the installation is exposed to significant electrical noise.\u003c\/li\u003e\n\u003cli\u003eSet the digital input filter according to the field signal characteristics. Increasing filtering can increase effective signal recognition delay.\u003c\/li\u003e\n\u003cli\u003eVerify input polarity and voltage before connecting field wiring to prevent incorrect signal interpretation.\u003c\/li\u003e\n\u003cli\u003eCheck insulation and dielectric requirements when commissioning wiring connected to the external input circuits.\u003c\/li\u003e\n\u003cli\u003eDo not assume hot-swapping capability for the I\/O unit unless the applicable CJ-series hardware documentation explicitly permits the operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital input channels does the CJ1W-ID261 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CJ1W-ID261 provides 64 DC input channels. They are arranged as four 16-point common circuits and occupy 4 words in the CJ I\/O allocation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage range is permitted for the inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The rated input voltage is 24 VDC, with a specified rated input voltage range of 20.4 to 26.4 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What connector does the CJ1W-ID261 use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit uses two 40-pin Fujitsu\/OTAX-compatible connectors. Omron distinguishes this model from the CJ1W-ID262, which uses MIL connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the physical dimensions of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The physical dimensions are 3.1 cm x 9.0 cm x 6.5 cm, corresponding to 31 mm x 90 mm x 65 mm in the CJ-series dimensional documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the input impedance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified input impedance is 5.6 kOhm. At the rated 24 VDC input voltage, the typical input current is 4.1 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the specified input response times?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Both ON and OFF response times are specified at 8.0 ms maximum. The digital filter can be configured from 0 to 32 ms through the applicable CJ-series setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CJ1W-ID261 accept both NPN and PNP sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Omron states that its 24 VDC input models can connect to devices with either NPN or PNP outputs. Devices sharing one common must use the same polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum internal current consumption?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Omron specifies 90 mA maximum internal current consumption from the 5 VDC PLC supply. This corresponds to a maximum internal power demand of approximately 0.45 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306664116397,"sku":"CJ1W-ID261","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-ID261_1_ed703e4d-4d28-46ef-a3fe-8753a3d60ec5.jpg?v=1788156050"},{"product_id":"omron-nx-eic202-nx-series-ethernet-ip-coupler-unit","title":"Omron NX-EIC202 NX-series EtherNet\/IP Coupler Unit","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron NX-EIC202\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"43\"\u003eNX-EIC202\u003c\/b\u003e Coupler Unit, operates as a dedicated hardware component for fieldbus packet translation and slave bus management within EtherNet\/IP network platforms.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Code Interpretation\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Compact I\/O system base product line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eEIC\u003c\/b\u003e: EtherNet\/IP communication coupler module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e202\u003c\/b\u003e: Standard functional specification revision supporting implicit and explicit CIP messaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-EIC202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.110 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e0.350 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003ePhysical Dimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e10.00 cm x 4.60 cm x 7.10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e15.00 cm x 10.00 cm x 8.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e1.25 W max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003ePower Supply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e24 VDC (20.4 to 28.8 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e2 x RJ45 (100Base-TX)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eMax I\/O Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eUp to 63 NX-series I\/O units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003ePacket Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eUp to 10000 pps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDeterministic Network Bus Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe module utilizes an internal backplane bus communication velocity profile designed for high-density I\/O data refresh cycles across downstream expansion blocks. Real-time CIP messaging protocol engines maintain low-jitter EtherNet\/IP determinism, while integrated firmware flash compatibility ensures synchronized operational execution during dynamic network topology changes.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eDeliverable Package Breakdown\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-EIC202 EtherNet\/IP Coupler Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Bus end cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Installation manual sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003eSecure the module onto a standard 35 mm DIN rail in a horizontal orientation inside an IP54-rated industrial cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eConnect the 24 VDC system power supply using twisted-pair copper conductors with cross-section areas between 0.2 mm2 and 2.5 mm2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003eEnsure standard Ethernet CAT5e or CAT6 shielded cable connections are routed away from high-voltage AC motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003eGround the functional earth terminal via a dedicated copper wire directly connected to the cabinet earth bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eWhat is the maximum number of NX I\/O units that can be attached to one NX-EIC202?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eA single coupler unit controls up to 63 connected NX I\/O units along the right-side local expansion backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eDoes the NX-EIC202 support hot-swapping of attached I\/O modules during operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eNo, power to the coupler and total backplane must be turned off before replacing or adding attached I\/O units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eHow are IP address settings configured on the NX-EIC202 coupler?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eIP addresses are assigned via hardware rotary switches located on the front panel or configured via Sysmac Studio software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eWhat communication topologies are supported by the dual RJ45 Ethernet ports?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eThe onboard dual ports support star, daisy-chain, and ring network topologies via EtherNet\/IP CIP messaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat type of cable shield grounding is recommended for the communication lines?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eUse double-shielded STP cables grounded at both switch ends to prevent industrial electromagnetic noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eIs external power supply wiring required for downstream I\/O module operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eYes, separate power connections are required for internal logic circuit supply and field output load power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eHow does the coupler indicate internal CPU or communication fault status?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eStatus indicators labeled MS (Module Status), NS (Network Status), and IO PWR display solid or flashing diagnostic LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eWhat is the maximum length per EtherNet\/IP network segment connected to the unit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eThe maximum physical cable length between the coupler and the adjacent network switch or node is 100 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306664575149,"sku":"NX-EIC202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-EIC202-1.jpg?v=1790689450"}],"url":"https:\/\/www.maxwellplc.com\/collections\/omron-plc-i-o-communication-modules.oembed?page=3","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}