{"title":"GE PacSystem RX3i","description":"\u003cp\u003e\u003cspan\u003eEngineered for the Industrial Internet, the \u003c\/span\u003e\u003cstrong\u003eGE PacSystem RX3i (IC695 series)\u003c\/strong\u003e\u003cspan\u003e provides a single control engine for high-performance automation. Our inventory features high-speed processors, universal I\/O backplanes, and advanced communication modules. The RX3i is built to handle complex motion control and heavy data processing, making it a staple in modern manufacturing. If you are looking to replace a module or expand your current PAC configuration, our technical stock ensures you get the exact hardware revision your system demands.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ic695psa140-ge-fanuc-pacsystems-rx3i-power-supply-module","title":"IC695PSA140 GE Fanuc PACSystems RX3i Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC695PSA140 is a multi-purpose power supply module engineered for PACSystems™ RX3i PLC platforms. It is designed to deliver stable system and field power while supporting redundant and load-sharing configurations within RX3i racks. This module enhances system availability by allowing multiple power supplies to operate in parallel, ensuring continuous operation during power faults or maintenance events.\u003c\/p\u003e\n\u003cp\u003eThe IC695PSA140 mounts directly into the RX3i backplane and distributes regulated DC power to both the controller and installed I\/O modules. Its wide AC and DC input range makes it suitable for global industrial environments where power conditions may vary.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput voltage range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e85–264 VAC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100–300 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eTotal output power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e40 W maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5.1 VDC backplane power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC relay and field output power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3.3 VDC internal logic power for RX3i modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOvercurrent protection on all outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvertemperature and overload monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eStatus indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower status LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFault LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvertemperature LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eRide-through capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains output for approximately 20 ms during input interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical characteristics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies two RX3i backplane slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports installation of up to four power supply modules per rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCompatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned exclusively for PACSystems RX3i racks and modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140 is commonly deployed in mission-critical automation systems where high reliability and power redundancy are required. Typical use scenarios include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant PLC power architectures in continuous-process industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRX3i systems with high I\/O density requiring additional backplane power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial control panels with mixed AC and DC power sources\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing lines, energy systems, and infrastructure automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring hot-standby or load-sharing power configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis power supply is well suited for environments where uptime, electrical stability, and modular expansion are essential.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519036514477,"sku":"IC695PSA140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695psa140-multi-purpose-power-supply-43i0vjkrjav.jpg?v=1766985426"},{"product_id":"ic220str001-versapoint-reversing-motor-starter-ge-fanuc-pacsystems-rx3i","title":"IC220STR001 VersaPoint Reversing Motor Starter | GE Fanuc PACSystems RX3i","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC220STR001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaPoint reversing motor starter module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for distributed motor control architectures where starter functionality is mounted close to the motor and managed through the VersaPoint I\/O system. It supports forward\/reverse motor operation and is intended for integration in PLC-controlled automation systems requiring compact panel layouts and modular expansion. Typical applications include conveyor direction control, indexing tables, hoists, and any machine axis that requires directional change with electrical interlocking.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC220STR001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries \/ Family: VersaPoint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Reversing Motor Starter Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor Control: Reversing (Forward\/Reverse) starter function for industrial motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply System: Three-phase motor applications (starter function)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOverload protection support (starter-protection coordination dependent on system design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit protection support (external protective devices typically required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration: Designed to operate within VersaPoint distributed I\/O assemblies for PLC-based control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: Compact form factor for enclosure mounting and modular I\/O layouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommercial \/ Logistics Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead Time: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 6.5 × 10.8 × 22.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscontinued: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConveyor sections requiring direction change and controlled reversing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHoists, lifts, and material handling with forward\/reverse commands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and assembly machines with reversible drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated storage and retrieval subsystems (directional movement control)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit projects where motor starter functions are migrated to distributed control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519038447789,"sku":"IC220STR001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic220str001-versapoint-reversing-motor-starter-szzwxhspkca.jpg?v=1766985503"},{"product_id":"ic698psa350-ge-fanuc-rx7i-pacsystems-power-supply-module","title":"IC698PSA350 GE Fanuc RX7i PACSystems Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC698PSA350\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erack power supply for PACSystems RX7i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLCs. Installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eslot 0\u003c\/strong\u003e, it delivers regulated backplane power and integrated cooling to support CPU, I\/O, and communication modules in an RX7i chassis.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC698PSA350\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: PACSystems RX7i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput: 85–264 VAC (47–63 Hz) or 100–150 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal: 120\/240 VAC, 125 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Power: 350 W rated (typical input demand ~440 W, max 500 W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling: built-in forced-air fan (approx. 70 CFM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection\/Diagnostics: over-temp, over-voltage, airflow monitoring; LEDs include Field OK, Output OK, Over Temp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold-up \/ Ride-through: 5 ms \/ 15 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: 1500 VDC (outputs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temp: 0–60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 2.02 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 6.3 × 18.5 × 29.1 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New, In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower source for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX7i racks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein manufacturing lines and process control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh backplane power capacity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand continuous airflow cooling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit\/maintenance replacement for RX7i chassis power slot installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519041855661,"sku":"IC698PSA350","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic698psa350-pacsystems-power-supply-module-wxgo2yhj5cs.jpg?v=1766985582"},{"product_id":"ic694pwr321-ge-fanuc-pacsystems-rx3i-power-supply-module","title":"IC694PWR321 GE Fanuc PACSystems RX3i Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC694PWR321\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX3i PACSystems power supply module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused to provide regulated backplane and auxiliary DC power for compatible RX3i PLC racks. It mounts in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eleftmost power-supply position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the RX3i baseplate and supports standard AC or DC input sources for industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC694PWR321\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage: 85–264 VAC (120\/240 VAC nominal), 100–300 VDC (125 VDC nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutputs:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5 VDC backplane output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC relay power bus output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC isolated output for field\/input circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Rating: up to 2 A (system load dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundancy: no load-sharing \/ no redundant operation support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Indication: PWR, OK, RUN LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New, In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.52 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 13 × 6.8 × 13.1 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Industrial Uses\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePowering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX3i PLC baseplates\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith mixed I\/O configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupplying\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5V backplane\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower plus\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor relay output modules and field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl panels in manufacturing, packaging, material handling, and process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519041921197,"sku":"IC694PWR321","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694pwr321-power-supply-module-xf5uyyo1fnl.jpg?v=1766985585"},{"product_id":"ic695pbm300-ge-fanuc-rx3i-profibus-dp-master-communication-module","title":"IC695PBM300 GE Fanuc RX3i PROFIBUS-DP Master Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC695PBM300 is a PROFIBUS-DP master module for PACSystems RX3i controllers, used to manage cyclic I\/O exchange between an RX3i rack and PROFIBUS-DP field devices. It enables integration of distributed I\/O, drives, valve terminals, and other DP slave equipment under deterministic network timing. The module installs on the RX3i backplane and provides network status reporting for commissioning and ongoing maintenance.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC695PBM300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: PROFIBUS-DP Master Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Role: DP Master\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDP Slave Capacity: Up to 125 slaves (network dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Capacity: Up to 3584 bytes input and 3584 bytes output (configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePer-Slave Data Limit: Up to 244 bytes input and 244 bytes output (device dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Baud Rates: 9.6 kbit\/s to 12 Mbit\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDP Functions: Sync, Freeze, DP-V1 acyclic services (Read, Write, Alarm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Slave status bit array, network and master diagnostic counters, diagnostic addressing, module revision reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: 9-pin Sub-D PROFIBUS interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: PROFIBUS-compliant LEDs for module and network state\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirmware Handling: Upgradable via host controller using WinLoader\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Power: 440 mA at 3.3 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 to 85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration Software: Proficy Machine Edition, commonly requiring SP2 or later for configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eController Compatibility: Typically requires RX3i CPU firmware v2.9 or later\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New, In Stock, Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA, Weight 0.16 kg, Size 3.5 × 13.5 × 13.6 cm, HS Code 8537101190, MOQ 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePROFIBUS-DP master control for distributed I\/O islands and remote panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrive and motion system integration using DP slave devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess skids and packaging lines requiring deterministic fieldbus data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModernization projects adding PROFIBUS connectivity to RX3i-based control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance replacement for installed RX3i PROFIBUS master modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519042052269,"sku":"IC695PBM300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695pbm300-profibus-master-module-uh5hvv2jlga.jpg?v=1766985592"},{"product_id":"ic694alg221-ge-fanuc-rx3i-4-channel-4-20ma-analog-input-module","title":"IC694ALG221 GE Fanuc RX3i 4-Channel 4–20mA Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC694ALG221 is a four-channel analog current input module used with PACSystems RX3i controllers to acquire 0–20 mA and 4–20 mA process signals. It converts field current loops from transmitters and signal conditioners into digital values for monitoring, scaling, and closed-loop control functions within the PLC\/PAC system.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC694ALG221\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Analog Current Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannels: 4 current inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Ranges: 0–20 mA, 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 4 µA at 4–20 mA, 5 µA at 0–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.1% of full scale plus ±0.1% of reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate Rate: 2 ms per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance: 250 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Filter Response: 325 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommon-Mode Voltage: Up to 200 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinearity: Less than 1 LSB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration: Factory calibrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-Swap: Supported with proper handling procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Module OK LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Power Draw: 100 mA at 24 VDC isolated, 25 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New, In Stock, Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13.2 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA transmitter inputs for pressure, flow, level, and temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess measurement acquisition for PID and closed-loop control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal integration from isolators, converters, and loop-powered instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpansion or replacement of current input capacity in RX3i control racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519043035309,"sku":"IC694ALG221","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694alg221-4-channel-analog-current-input-module-o3zyfon4aj4.jpg?v=1766985622"},{"product_id":"ic695alg600-ge-fanuc-rx3i-universal-analog-input-module","title":"IC695ALG600 GE Fanuc RX3i Universal Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC695ALG600 is a universal analog input module for PACSystems RX3i PLC\/PAC systems. It is used to acquire multiple types of field signals in a single module, including voltage and current transmitters, resistance-based measurements, and temperature sensors such as thermocouples and RTDs.\u003c\/p\u003e\n\u003cp\u003eThe module provides two independent channel groups, allowing mixed signal types within the same unit when configured in the controller project. This makes it suitable for skids and process panels where different sensor technologies must be connected to one RX3i backplane while maintaining clear channel-level configuration and diagnostics.\u003c\/p\u003e\n\u003ch3\u003eSignal and Hardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC695ALG600\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Universal Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel Count: 8 inputs total, arranged as two groups of 4 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Input Types:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent 0–20 mA, 4–20 mA, ±20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage ranges commonly used in control systems such as 0–10 V and 1–5 V, plus additional selectable voltage modes by configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement modes and RTD sensor inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple temperature inputs (type availability depends on configuration and firmware support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Block Requirement: Compatible RX3i terminal blocks such as IC694TBB032 (box-style) or IC694TBB132 (extended box-style)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics and Indication: Module Status, Field Status, and Terminal Block LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoftware Compatibility: Proficy Machine Edition (PME) v5.0 SP1A or later\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane and Firmware Notes: Designed for RX3i universal backplane, firmware revision requirements depend on system release level (commonly referenced as v2.80 or higher)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirmware Maintenance: Flash-based design supports field firmware updates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Dissipation: Up to 5.4 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.24 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13.5 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess instrumentation acquisition including pressure, flow, and level transmitters using 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement using thermocouples and RTDs in furnaces, reactors, or utility systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMixed-signal skid panels where voltage, current, and temperature inputs must coexist in one rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit and expansion of PACSystems RX3i systems requiring flexible analog input capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM machine builds that standardize on a universal analog module to reduce spare parts complexity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519044542637,"sku":"IC695ALG600","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695alg600-universal-analog-input-module-qsideycqlzo.jpg?v=1766985689"},{"product_id":"ge-fanuc-ic695cmm004-pacsystems-rx3i-serial-communication-module","title":"GE Fanuc IC695CMM004 PACSystems RX3i Serial Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC695CMM004 is a multi-port serial communication module designed for PACSystems RX3i PLC platforms. This module expands controller connectivity by providing four independently operating and electrically isolated serial ports, enabling reliable data exchange between the PLC and a wide range of serial-based industrial devices.\u003c\/p\u003e\n\u003cp\u003eEach port is equipped with an RJ45 connector and supports flexible serial standards, allowing the module to be used in point-to-point or multi-drop network architectures. The IC695CMM004 is commonly applied in systems where multiple field devices must be integrated using established serial protocols. Its modular design allows multiple communication modules to be installed within a single RX3i system, significantly increasing overall serial port capacity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC695CMM004\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Category: PLC Serial Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Ports: 4 isolated serial ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Type: RJ45 per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Interfaces: RS232, RS422, RS485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Protocols: Modbus Master and Slave, CCM Slave, DNP3 Master and Slave, Serial I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBaud Rate Range: 1200 to 115.2 kbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Isolation: 500 VDC port-to-port isolation, 250 VAC isolation to backplane and frame ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostic Indicators: Module OK and status LEDs for fault and communication monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirmware: Field-upgradable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature Range: 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: Up to 0.7 A at 3.3 VDC and 0.15 A at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation Platform: RX3i PLC baseplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNet Weight: 0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13 × 13.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Order Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of power meters, protection relays, and energy monitoring devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication with variable frequency drives and motor controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial connectivity for protocol converters and third-party control equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-device serial networks in process automation and utility systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpansion or replacement of communication infrastructure in PACSystems RX3i PLC installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519044640941,"sku":"IC695CMM004","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695cmm004-serial-communications-module-q0ttcyoj15y.jpg?v=1766985692"},{"product_id":"ic694mdl940-ge-fanuc-pacsystems-rx3i-relay-output-module-16-point","title":"IC694MDL940 GE Fanuc PACSystems RX3i Relay Output Module 16-Point","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC694MDL940\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel relay output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC racks. It provides dry-contact switching for common industrial loads and is suitable for interfacing a controller to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtactors, solenoids, pilot lights, and auxiliary relays\u003c\/strong\u003e. Outputs are arranged in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour output groups\u003c\/strong\u003e, supporting flexible field wiring and straightforward diagnostics through per-point status indication.\u003c\/p\u003e\n\u003ch3\u003eElectrical \u0026amp; Hardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC694MDL940\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Relay Output Module (Voltage Output \/ Discrete Relay Output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Quantity: 16 points (4 groups × 4 points)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact Form: N.O. (Form A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRated Load: 2 A per point, 4 A per group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Load: 10 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush Capability: up to 5 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching Response: typical 15 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Consumption: 135 mA max @ 24 V relay bus; 7 mA @ 5 V bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: 250 VAC continuous \/ 1500 VAC 1 min field-to-backplane; 250 VAC continuous channel-to-channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: no internal fusing (use external fuses per application)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: 1-slot, fits RX3i IC694 backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.52 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 13 × 6.8 × 13.1 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching AC\/DC control circuits for starters, coils, and annunciators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput expansion for RX3i discrete control where relay isolation is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical interfacing between PLC logic and mixed-voltage field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519048835245,"sku":"IC694MDL940","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694mdl940-voltage-output-module-1sac0rzrfbo.jpg?v=1766985729"},{"product_id":"pacsystems-rx7i-ge-fanuc-ic698cpe020-cpu-module-central-processing-unit","title":"PACSystems RX7i GE Fanuc IC698CPE020 CPU Module Central Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC698CPE020\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rack-based\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX7i CPU module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused to execute control logic, process data, and coordinate I\/O for large automation systems. It is suitable for high-throughput control architectures that require Ethernet connectivity and multi-protocol communications.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC698CPE020\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Series: Rx7i PACsystem\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: CPU Module (PLC Central Processing Unit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor: 700 MHz class CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory: 10 MB user RAM, 10 MB non-volatile flash\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O Capacity: up to 32K discrete I\/O, 32K words analog %AI \/ %AQ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgram Structure: up to 512 program blocks, up to 128 KB per block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet: 2 × 10\/100 Mbps ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial: 3 isolated serial ports (RS-232\/RS-485)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgramming Software: Proficy Machine Edition Logic Developer PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead Time: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.8 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 4 × 8 × 29.2 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMain CPU for PACSystems RX7i rack controllers in process and discrete automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet-connected control systems integrating HMI\/SCADA and plant data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit, expansion, or spare replacement for installed RX7i PLC\/PAC platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519049195693,"sku":"IC698CPE020","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic698cpe020-rx7i-pacsystem-cpu-uii53fv4pqx.jpg?v=1766985740"},{"product_id":"ic698cre030-ge-fanuc-pacsystems-cpu-module-central-processing-unit","title":"IC698CRE030 GE Fanuc PACSystems CPU Module Central Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC698CRE030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems CPU module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused as the main controller in GE rack-based automation systems. It executes control logic, manages I\/O data, and supports Ethernet-based communications for plant networks and supervisory systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC698CRE030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: CPU Module (Central Processing Unit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlatform\/Series: PACSystems (rack CPU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor Speed: 600 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser Memory: 64 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet: Integrated 10\/100 Mbps interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead Time: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.8 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 4 × 8 × 29.2 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Discontinued (Dec 31, 2018)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral controller for rack-based PAC\/PLC systems in manufacturing lines and process skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed logic execution with Ethernet connectivity to HMI\/SCADA and plant networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit and spare-part replacement for existing PACSystems installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519050277037,"sku":"IC698CRE030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic698cre030-pacsystem-cpu-central-processing-unit-4mhdskdplxa.jpg?v=1766985756"},{"product_id":"ic694mdl240-ge-fanuc-pacsystems-rx3i-120vac-16-point-input-module","title":"IC694MDL240 GE Fanuc PACSystems RX3i 120VAC 16-Point Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC694MDL240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-point AC discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O systems. It interfaces 120 VAC field signals to the RX3i controller, providing clear point-level indication and dependable input conditioning for industrial control panels.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC694MDL240\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Function: AC Discrete Input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Inputs: 16 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRated Input: 120 VAC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range: 85 to 132 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eON State \/ OFF State Threshold: 74 to 132 VAC \/ 0 to 20 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time: 30 ms ON, 45 ms OFF (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: Optical isolation, 250 VAC continuous; 1500 VAC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Indication: 16 channel LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Current: 90 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead Time: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.28 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13.2 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Industrial Uses\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReading 120 VAC signals from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches, selector switches, pushbuttons\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eauxiliary contacts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom relays\/contactors in MCC and control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete status acquisition in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ematerial handling, packaging, HVAC, and process skids\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC input collection where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epoint LEDs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplify commissioning and troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519052013741,"sku":"IC694MDL240","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694mdl240-volt-ac-input-module-2bymkusyudv.jpg?v=1766985789"},{"product_id":"ic695pnc001-ge-fanuc-pacsystems-rx3i-profinet-controller-module","title":"IC695PNC001 GE Fanuc PACSystems RX3i PROFINET Controller Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC695PNC001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFINET IO-Controller module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, used to connect an RX3i rack to PROFINET networks for cyclic I\/O exchange and device diagnostics. It integrates with compatible RX3i CPUs and supports common industrial Ethernet topologies for scalable remote I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eInterface \u0026amp; Performance Highlights\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC695PNC001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlatform: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Function: PROFINET Controller (IO-Controller)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Interfaces: 2 × RJ-45 Ethernet ports, 2 × SFP slots (SFPs ordered separately)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Addressing: Single IP used across onboard ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDevice Capacity: Up to 64 PROFINET I\/O devices per controller (application-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate Time: Configurable 1 ms to 512 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService Port: Micro USB for setup\/diagnostics (CLI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRIUP: Supports insertion\/removal under power (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Requirements: 5 VDC backplane; higher draw when SFPs installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead Time: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.64 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 4 × 21.7 × 29.1 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Automation Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRX3i as a PROFINET controller for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eislands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetworked machine skids using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estar, line (daisy-chain), or ring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elayouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed cyclic data exchange for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotion coordination, packaging, conveying, and assembly\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of PROFINET diagnostics into PLC\/HMI maintenance workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519052046509,"sku":"IC695PNC001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695pnc001-profinet-controller-module-f0yvrpc4ipg.jpg?v=1766985790"},{"product_id":"ic698cpe010-ge-fanuc-rx7i-cpu-module-pacsystems-controller","title":"IC698CPE010 GE Fanuc RX7i CPU Module | PACSystems Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC698CPE010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX7i CPU module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused as the main controller in modular PLC\/PAC architectures. It executes control logic, manages I\/O data, and coordinates communications across Ethernet and serial networks for large-scale automation systems.\u003c\/p\u003e\n\u003ch3\u003ePerformance and Hardware Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC698CPE010\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: CPU Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: PACSystems RX7i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor: Intel Celeron 300 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoolean Performance: approx. 0.33 ms per 1K contacts\/coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplication Memory: 10 MB battery-backed RAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-volatile Storage: 10 MB (retains configuration\/data)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgram Structure: up to 512 program blocks (max 128 KB each)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O Addressing Capacity: 32K bits %I \/ %Q, 32K words %AI \/ %AQ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunications: dual Ethernet 10\/100 Mbps, RS-232, RS-485, additional serial interfaces (as supported by system configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Ethernet Functions: SRTP, EGD, Modbus TCP (capability dependent on firmware\/system setup)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Resilience: supports ring\/redundancy features such as MRP (when enabled and properly configured)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead Time: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: approx. 0.62 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: approx. 4 × 18.3 × 29.1 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications and Integration Scenarios\u003c\/h3\u003e\n\u003cp\u003eIC698CPE010 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess automation, material handling, utilities, and large machine control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere higher memory capacity and multi-network connectivity are required. Typical integrations include distributed I\/O racks, HMI\/SCADA connectivity over Ethernet, controller-to-controller data exchange, and serial device interfacing for legacy equipment.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519055093933,"sku":"IC698CPE010","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic698cpe010-rx7i-cpu-module-02k1sjqju3z.jpg?v=1766985811"},{"product_id":"ic695pbs301-pacsystems-rx3i-profibus-dp-slave-module-ge-fanuc","title":"IC695PBS301 PACSystems RX3i PROFIBUS-DP Slave Module | GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC695PBS301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP slave communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC racks. It allows an RX3i system to appear as a slave node on a PROFIBUS network, enabling cyclic I\/O exchange and acyclic services with a PROFIBUS master. The module is used to integrate RX3i control hardware into existing PROFIBUS architectures without redesigning the fieldbus layer.\u003c\/p\u003e\n\u003ch3\u003eCommunication Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC695PBS301\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: PROFIBUS Slave Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork: PROFIBUS DP (supports standard DP baud rates)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: 9-pin D-sub\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData Size (max): 244 bytes input, 244 bytes output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDP-V1 Support: Read\/Write services and Alarm messaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot Usage: Single-slot module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Power: 3.3 VDC, 440 mA (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: PROFIBUS OK, Network (bi-color), Module Status (bi-color)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 to 85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirmware Update Method: Via host CPU using WinLoader\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 0.16 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 3.5 × 13.5 × 13.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Integration Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC695PBS301 is commonly used when an RX3i rack must interface with PROFIBUS-controlled lines, such as packaging systems, conveyor zones, OEM skids, and legacy process panels. It is also applied in retrofit projects where PROFIBUS masters remain in service and the control platform is upgraded while keeping the existing network and cabling.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519056699565,"sku":"IC695PBS301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695pbs301-profibus-slave-module-22yfdyhmkgm.jpg?v=1766985837"},{"product_id":"ic695cpe310-pacsystems-rx3i-cpu-module-2-slot-ge-fanuc","title":"IC695CPE310 PACSystems RX3i CPU Module (2-Slot) | GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC695CPE310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused as the primary controller for RX3i PLC racks. It runs the control program, manages I\/O updates, and provides built-in communications for integration with HMIs, SCADA, and plant networks. The CPU is designed for applications that require fast Boolean execution and scalable I\/O addressing in a compact RX3i hardware footprint.\u003c\/p\u003e\n\u003ch3\u003eControl Performance and Interfaces\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC695CPE310\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: PLC CPU Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eForm Factor: 2-slot CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor: 1.1 GHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoolean Execution: 0.72 ms per 1K (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunications:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet: 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial: 1 × RS-232, 1 × RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O Addressing Capacity (typical):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete: 32K points (%I \/ %Q)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog: 32K words (%AI \/ %AQ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eUser Memory: 10 MB battery-backed (data retention dependent on battery condition)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol Support (as configured): SRTP, Modbus (Master\/Slave), PROFINET options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEngineering Software: Proficy Machine Edition (PACSystems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 0.46 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 7 × 13.3 × 13.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscontinued On: Dec 31, 2018\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC695CPE310 is used in RX3i control systems for machine automation and process support, including packaging lines, conveyors, batching skids, utilities panels, and general-purpose PLC cabinets. It is also selected for maintaining installed RX3i systems where the application requires strong processing headroom and integrated Ethernet\/serial connectivity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519056896173,"sku":"IC695CPE310","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695cpe310-2-slot-central-processing-unit-fyywutax0be.jpg?v=1766985844"},{"product_id":"ic694mdl930-rx3i-8-point-isolated-relay-output-module-pacsystems-ge-fanuc","title":"IC694MDL930 RX3i 8-Point Isolated Relay Output Module PACSystems | GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC694MDL930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel relay output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC racks. It provides dry-contact switching to interface the controller with field devices such as contactors, solenoids, alarms, and indicator lamps. Each output is an individually isolated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eForm A (normally open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelay contact with a dedicated common, allowing mixed-voltage circuits on the same module when correctly wired.\u003c\/p\u003e\n\u003cp\u003ePoint LEDs provide quick verification of output status during commissioning and troubleshooting. Field loads are powered externally; the module switches the load circuit through relay contacts.\u003c\/p\u003e\n\u003ch3\u003eSwitching and Electrical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC694MDL930\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Isolated Relay Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutputs: 8 × relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact Form: Form A, normally open (N.O.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: Individual point isolation with separate commons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5–30 V DC (24 V DC nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5–250 V AC, 50\/60 Hz (120\/240 V AC nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Rating:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4 A per point (resistive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 A per point (pilot duty)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Load: 10 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical Switching Response: 15 ms ON \/ 15 ms OFF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Load Limit: Up to 30 A total for UL installations (derate with temperature)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDielectric Ratings: 250 VAC continuous, 1500 VAC for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: 8 output status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: Field power supplied externally (load side)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 3.5 × 13.2 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Use Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL930 is used where relay isolation and broad voltage compatibility are required within an RX3i control system. Common applications include switching motor starter coils, interposing relays, solenoid valves, stack lights, horns, and alarm circuits in manufacturing automation, material handling, utilities, and process skids.\u003c\/p\u003e\n\u003cp\u003eIt is also used in retrofit projects to maintain existing relay-controlled field wiring while upgrading or servicing RX3i PLC racks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519057551533,"sku":"IC694MDL930","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694mdl930-voltage-output-module-2uuzhxnbjet.jpg?v=1766985854"},{"product_id":"ic698etm001-rx7i-dual-port-ethernet-communication-module-pacsystems-ge-fanuc","title":"IC698ETM001 RX7i Dual-Port Ethernet Communication Module PACSystems | GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC698ETM001 Ethernet Interface Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides Ethernet networking for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX7i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC systems. It enables controller communications with HMIs, SCADA servers, historians, and Ethernet-based remote devices, supporting plant-wide data exchange and maintenance connectivity. Dual RJ45 ports allow flexible wiring layouts such as star or line topologies, reducing the need for additional network hardware in cabinet installations.\u003c\/p\u003e\n\u003cp\u003eA dedicated onboard processor handles network services and diagnostics, helping maintain stable communications in industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eNetwork and Interface Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC698ETM001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Ethernet Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX7i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet Ports: 2 × RJ45\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLink Speed: 10\/100 Mbps auto-negotiation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: CAT5 or higher\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTopology Support: Line\/daisy-chain and standard switched networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Options: Standard addressing with support for redundancy features (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService Port: 9-pin serial Station Manager port (1200–115200 bps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Protocols: TCP\/IP, Modbus TCP Server, Modbus TCP Client\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime Sync: SNTP client support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Module OK, LAN Online, Status, Link P1\/P2 LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessing: Dedicated microprocessor for Ethernet management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 2.1 × 17.3 × 29.3 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Use Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC698ETM001 is used in RX7i control systems that require reliable Ethernet communications for supervisory integration and networked device coordination. Typical deployments include manufacturing lines, process skids, utilities, material handling systems, and plant data acquisition architectures where PLCs must exchange data with multiple clients simultaneously.\u003c\/p\u003e\n\u003cp\u003eIt is also applied in retrofit projects to add Ethernet capability to existing RX7i racks while keeping installed I\/O and CPU hardware unchanged.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519058141357,"sku":"IC698ETM001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic698etm001-rx7i-ethernet-interface-module-extrapeezou.jpg?v=1766985863"},{"product_id":"ic694mdl742-pacsystems-rx3i-16-point-dc-output-module-ge-fanuc","title":"IC694MDL742 PACSystems RX3i 16-Point DC Output Module | GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC694MDL742 DC Output Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-point discrete output card for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eracks. It provides transistor-based output switching for 12\/24 VDC field devices and is commonly used for controlling relays, solenoids, indicators, and other DC loads in automation panels.\u003c\/p\u003e\n\u003cp\u003eThe module is grouped for structured wiring and includes onboard protection and clear status indication to support safe operation and faster troubleshooting. It can be installed in any compatible RX3i slot and supports replacement practices that minimize downtime when used with the appropriate system insertion\/removal mode.\u003c\/p\u003e\n\u003ch3\u003eOutput and Protection Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel Number: IC694MDL742\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: DC Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: General Electric (GE Fanuc)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Points: 16 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrouping: 2 groups of 8 outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogic Type: Negative logic (sinking)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Voltage Range: 12–24 V DC (tolerance -15% to +20%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-Circuit Protection: Electronic protection per output group (1–8, 9–16)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFault Indication: Fault LED when protection is active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel Status: Individual output LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Current Consumption: Approx. 130 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush Rating: 5.2 A for 10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot Swap Support: Supported via controlled insertion\/removal mode (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Power: External power required for connected loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 3.5 × 13.2 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Use Environments\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL742 is used in RX3i-based control cabinets for DC load switching in machine automation and process equipment. Typical applications include actuator control, motor starter interposing relays, alarm beacons, solenoid valves, and panel signaling.\u003c\/p\u003e\n\u003cp\u003eIt is a practical choice for installations that require protected output groups, clear LED feedback, and standardized 12\/24 VDC discrete output control within PACSystems RX3i systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519058337965,"sku":"IC694MDL742","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694mdl742-voltage-output-module-cahvrpczv1x.jpg?v=1766985871"},{"product_id":"ic698rmx016-ge-fanuc-pacsystems-rx7i-redundancy-memory-exchange-module","title":"IC698RMX016 GE Fanuc PACSystems RX7i Redundancy Memory Exchange Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC698RMX016\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRedundancy Memory Exchange (RMX) module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX7i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC platforms. It is used in high-availability control architectures to exchange critical data between CPUs in a redundant system. By participating in a reflective-memory style network over fiber, the RMX module helps keep redundant controllers synchronized, supporting continuous operation in applications where downtime is not acceptable.\u003c\/p\u003e\n\u003cp\u003eThe module is typically installed in RX7i racks used for redundancy systems and receives operating parameters directly from the host CPU, reducing commissioning time and configuration errors.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct family: PACSystems RX7i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: Redundancy Memory Exchange (RMX) module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory capacity: 16 MB SDRAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane supply: 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent draw: 1.8 A (from backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork capacity: Up to 256 nodes (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData transfer: Dynamic packet sizes typically 4–64 bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiber interface: LC-type fiber optic connector (IEC 61754-20)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptical performance (connector spec):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInsertion loss: ≤ 0.35 dB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReturn loss: ≥ 30 dB (typical reference value)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eControls and indication: Status LEDs and a guarded toggle switch for role change\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -20°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoftware\/firmware note: Requires PACSystems firmware 2.00 or later and compatible Logic Developer environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePhysical and commercial data\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 2.1 × 18 × 29.2 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.30 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant PLC systems requiring continuous controller synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-availability control for power generation, oil and gas, and continuous process lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical infrastructure automation where coordinated CPU switchover is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems using fiber-based memory exchange to reduce electrical noise sensitivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModernization projects retaining RX7i redundancy architectures with like-for-like spares\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519059517613,"sku":"IC698RMX016","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic698rmx016-redundancy-memory-xchange-rmx-module-scfrjjlf1b4.jpg?v=1766985911"},{"product_id":"ic694mdl645-ge-fanuc-24vdc-16-channel-discrete-input-module-pacsystems-rx3i","title":"IC694MDL645 GE Fanuc 24VDC 16-Channel Discrete Input Module PACSystems RX3i","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe GE IC694MDL645 is a 16-point discrete input module engineered for high-density signal acquisition within the PACSystems™ RX3i platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is designed to interface with a wide range of 24 VDC field devices,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a critical link between industrial hardware and the PLC processor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA key feature of the IC694MDL645 is its internal circuitry,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich supports both positive and negative logic (sink or source) configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering maximum flexibility during control cabinet wiring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts compact architecture allows for seamless integration in both local RX3i backplanes and remote I\/O stations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring reliable data feedback for automated processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Hardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Points\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 channels organized in a single group with a common return.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC nominal,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith an absolute range of 0 to 30 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLogic Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports both Sink and Source wiring configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Thresholds\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eON-state requires 11.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 VDC to 30 VDC; OFF-state is defined as 0 VDC to 5 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCurrent Consumption\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTypically draws 80 mA from the 5V backplane bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Impedance\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned with a 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 mA minimum ON-state current to ensure signal stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResponse Time\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7ms typical (input filter) for reliable noise rejection in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolation Integrity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRated for 1500 VAC (1 minute) between the field-side inputs and the logic-side backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVisual Indicators\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 independent green LEDs located at the top of the module for real-time status monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Profile\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWeight:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 kg; Dimensions:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC694MDL645 is a workhorse component in diverse automation sectors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHigh-Speed Manufacturing\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is used to track the status of limit switches,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoptical sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand emergency stop buttons across assembly lines.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eMaterial Handling\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit monitors pallet detection and conveyor gate positions to ensure synchronized movement.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eEnergy and Infrastructure\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprojects,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module provides the ruggedness needed to interface with field-mounted pressure switches and flow meters.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts compatibility with the RX3i series makes it a go-to solution for system integrators looking to upgrade legacy GE 90-30 systems to modern PACSystems technology while maintaining reliable 24V discrete signaling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519062859949,"sku":"IC694MDL645","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic694mdl645-voltage-input-module-uvrwbqyufnv.jpg?v=1766985994"},{"product_id":"ge-fanuc-ic695acc412-pacsystems-rx3i-replacement-cap-pack-module","title":"GE Fanuc IC695ACC412 PACSystems RX3i Replacement Cap Pack Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC695ACC412\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereplacement capacitor pack (cap pack) module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems™ RX3i Energy Pack assemblies\u003c\/strong\u003e. It provides short-term hold-up power required for the CPU to complete an orderly power-loss operation, including protecting user data and supporting the transfer of critical contents to non-volatile memory when input power is removed.\u003c\/p\u003e\n\u003cp\u003eThis module is commonly used as a service replacement to restore energy pack hold-up performance over time and to maintain correct backup behavior for supported RX3i CPU systems.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct type: Replacement Cap Pack Module (capacitor pack)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct family: PACSystems™ RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary function: Hold-up energy for power-loss data retention operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical compatibility: RX3i Energy Pack assemblies used with supported RX3i CPUs (commonly applied with CPE330-class systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpected service life: Approx. 5 years (capacitor aging dependent on operating conditions)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus indication: Energy Pack status LED shows charging\/ready behavior after installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation position: Mounts to the bottom section of the RX3i energy pack assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandling requirements: Install with power removed; allow full charge time before placing system into service\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePhysical and commercial data\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.24 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13.5 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePreventing loss of user data during sudden AC\/DC supply interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRestoring correct backup energy performance during preventive maintenance cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService replacement for aging cap packs in 24\/7 continuous PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial automation lines requiring controlled CPU shutdown behavior and memory protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Ge Fanuc","offers":[{"title":"Default Title","offer_id":45519067218093,"sku":"IC695ACC412","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ge-fanuc-ic695acc412-replacement-cap-pack-module-iixdoggeeib.jpg?v=1766986081"},{"product_id":"ic694alg392-general-electric-pacsystems-analog-output-module-8-channel","title":"IC694ALG392 General Electric PACSystems Analog Output Module 8-Channel","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC694ALG392 is an 8-channel analog output module for PACSystems control platforms. It provides configurable current or voltage control signals for field devices such as valve positioners, VFD references, actuators, and process controllers.\u003c\/p\u003e\n\u003ch3\u003eSignal \u0026amp; Power Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ order number: IC694ALG392\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: Analog output module, 8 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signal types: Voltage or current (software configurable by channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommon ranges: 0–10 V, ±10 V, 0–20 mA, 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: Up to 16-bit (range-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate performance: Channel updates within millisecond-scale scan timing (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Output fault reporting via controller diagnostics (includes current-loop open-wire indication in current mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: Requires 24 VDC class field supply (typical), with backplane support as applicable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new, In stock, MOQ 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprox. dimensions: 3.5 × 13 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprox. weight: 0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA control to I\/P converters, control valves, and transmitters in loop test setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–10 V \/ ±10 V references for drives, actuators, and analog-controlled equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePID output to final control elements in process automation skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog re-transmission to recorders, indicators, and signal isolators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519068889261,"sku":"IC694ALG392","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic694alg392-analog-output-module-irguuen51xq.jpg?v=1766986137"},{"product_id":"ic695psd040f-general-electric-pacsystems-rx3i-24vdc-power-supply-module","title":"IC695PSD040F General Electric PACSystems RX3i 24VDC Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC695PSD040F is a 24 VDC power supply module for PACSystems RX3i universal backplanes. It converts a 24 VDC source into regulated backplane power and provides protection and status feedback to support stable PLC operation in industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ order number: IC695PSD040F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: Power supply module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput voltage: 18 to 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRated output power: 40 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput power rating: 60 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane installation: Single-slot module for RX3i universal backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus diagnostics: Power supply fault, overload, overtemperature indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring: 14 to 22 AWG, one wire per terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStock status: In stock, MOQ 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprox. dimensions: 8.2 × 12.2 × 6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprox. weight: 0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC power distribution for RX3i PLC racks and I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing automation panels requiring regulated backplane power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control and infrastructure PLC installations using PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstalled-base replacement for IC695PSD040F power supply modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519069610157,"sku":"IC695PSD040F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695psd040f-power-supply-module-loscum4a1qx.jpg?v=1766986165"},{"product_id":"general-electric-ic695cpu310-pacsystems-rx3i-cpu-module","title":"General Electric IC695CPU310 PACSystems RX3i CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC695CPU310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i PLC\/PAC controller CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for high-speed machine and process control in modular rack-based automation systems. Installed on an RX3i universal backplane, it executes user logic, manages controller memory, and coordinates data exchange with I\/O and communication modules.\u003c\/p\u003e\n\u003cp\u003eThis controller supports migration scenarios by maintaining broad compatibility with legacy Series 90-30 I\/O (application dependent), making it suitable for modernizing installed systems while preserving existing field wiring and rack layouts.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695CPU310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePLC Controller (PACSystems RX3i CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e300 MHz Intel Celeron-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical logic performance\u003c\/td\u003e\n\u003ctd\u003e0.195 ms per 1000 Boolean instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser memory (RAM)\u003c\/td\u003e\n\u003ctd\u003e10 MB battery-backed CMOS RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser memory (Flash)\u003c\/td\u003e\n\u003ctd\u003e10 MB non-volatile flash for user data storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial communications\u003c\/td\u003e\n\u003ctd\u003e2 ports total RS-232 and RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003eProvided via rack Ethernet interface module (not built into CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane interface\u003c\/td\u003e\n\u003ctd\u003eHigh-speed PCI backplane bus (RX3i)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 × 13 × 13.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinued status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOQ\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-speed control execution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuited for time-critical discrete and process applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge onboard memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupporting sizable programs, configuration data, and symbolic variables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual serial ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor integration with legacy devices, HMIs, and serial networks (protocols depend on system setup)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack-based expansion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing RX3i backplanes with scalable I\/O and communications modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade-friendly platform\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupporting phased migrations where older I\/O needs to remain in service\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork-ready architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenabling time synchronization and plant networking when used with an Ethernet interface module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMachine automation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epackaging, material handling, assembly lines, and test stands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilities, batching, pumping\/skids, and general plant automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModernization projects\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eupgrading from legacy racks while maintaining existing I\/O investments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed control cabinets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere modular I\/O and communication expansion is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519071183021,"sku":"IC695CPU310","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695cpu310-plc-controller-mx5luppsyhs.jpg?v=1766986220"},{"product_id":"8751-ca-ns-safetynet-controller-carrier-general-electric-pacsystems-module","title":"8751-CA-NS Safetynet Controller Carrier - General Electric PACSystems Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe General Electric 8751-CA-NS serves as a specialized SafetyNet Controller Carrier within the PAC8000 automation architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis critical hardware foundation is engineered to host controller modules while providing dedicated circuitry for integrated earth leakage fault detection.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy centralizing power distribution and signal routing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8751-CA-NS ensures high-integrity monitoring of safety-critical loops.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt acts as the physical and electrical backbone for safety controllers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating high-speed data exchange and providing reliable fault isolation to protect both personnel and sensitive industrial assets from electrical malfunctions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Configuration and Physical Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8751-CA-NS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Watts (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 9-pin D-type serial connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew terminals for Ground, BFP0V, and Power Fail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlat panel mount with four-point security\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.2 x 20.7 x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eFunctional Application and System Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 8751-CA-NS is deployed in complex industrial environments where safety integrity is the highest priority.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts utility is demonstrated in the following scenarios:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Instrumented Systems (SIS):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding a secure mounting platform for controllers managing Emergency Shutdown (ESD) protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLeakage Detection Monitoring:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing built-in earth leakage sensing to identify insulation breakdown in industrial power loops before they lead to system failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDistributed Control Systems (DCS):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a high-reliability node within the PAC8000 series for real-time process supervision and safety interlocking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHazardous Area Operations:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand the thermal and atmospheric stresses of oil and gas processing or chemical manufacturing sites.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519073312941,"sku":"8751-CA-NS","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-8751-ca-ns-safetynet-controller-carrier-hkdscjcffrb.jpg?v=1766986266"},{"product_id":"ic695chs012-general-electric-pacsystems-rx3i-12-slot-universal-backplane","title":"IC695CHS012 General Electric PACSystems RX3i 12 Slot Universal Backplane","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC695CHS012 is a 12-slot universal backplane used in PACSystems RX3i PLC rack assemblies. It provides the mechanical mounting structure and the internal bus connections required for the CPU and I\/O modules to communicate within a chassis. The backplane is designed to support mixed module populations, enabling system builds that combine newer RX3i hardware with compatible legacy-style modules where applicable.\u003c\/p\u003e\n\u003cp\u003eFor panel builders and maintenance teams, the IC695CHS012 offers a standardized rack foundation for modular expansion, clear slot identification for configuration control, and practical wiring points to support stable cabinet grounding and 24 V distribution practices.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ order number: IC695CHS012\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: Universal backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct family: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot capacity: 12 slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane architecture: Dual-bus design for mixed module support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule support: PCI-based and serial I\/O module compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy support reference: Designed to support integration with Series 90-30 compatible modules where applicable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrientation: Horizontal rack mount design with labeled slot positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5 VDC bus current: 240 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3.3 VDC bus current: 600 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring feature: Terminal strip for isolated 24 V input distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding provisions: Dedicated grounding points for cabinet bonding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance feature: Supports hot-swap capable system maintenance when used with compatible modules and system design rules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand new\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct lifecycle status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum order quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximate dimensions: 20 × 11.5 × 5.7 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximate weight: 0.9 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem application: DCS and industrial automation control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication service: Ethernet router\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePACSystems RX3i PLC rack builds requiring a 12-slot universal backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular I\/O expansion for industrial automation and process control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl panel retrofits where mixed module support is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance replacement for damaged or aging RX3i chassis backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM machine control systems using rack-based PLC architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519073640621,"sku":"IC695CHS012","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695chs012-universal-backplane-lbsplvzzrdd.jpg?v=1766986279"},{"product_id":"ic694mdl660-general-electric-pacsystems-rx3i-discrete-input-module","title":"IC694MDL660 General Electric PACSystems RX3i Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC694MDL660 is a high-density 24 VDC discrete input module for PACSystems RX3i control architectures. It provides 32 input points in a compact footprint to acquire on\/off field signals from sensors, switches, and contact outputs. The module is organized into isolated input groups to improve noise immunity and simplify field wiring in multi-circuit panels.\u003c\/p\u003e\n\u003cp\u003eFor commissioning and maintenance, each input channel has a dedicated status indicator, allowing fast verification of field device state without external test equipment. Configurable input filtering supports reliable operation in electrically noisy environments and helps prevent false input transitions caused by contact bounce or transient interference.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Hardware Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC694MDL660\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family: PACSystems (RX3i \/ IC694)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: 24VDC Discrete Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Count: 32 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrouping: 4 isolated groups, 8 points per group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal Input Voltage: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range: 0 to 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Current: 7.0 mA per point at rated voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogic Thresholds:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eON state: 11.5 to 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOFF state: 0 to 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eGroup-to-Group Isolation: 250 VAC continuous (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Filtering: 7 selectable filter times, 0.5 ms to 100 ms (affects ON\/OFF response time)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Block Requirement: High-density terminal blocks IC694TBB032 or IC694TBS032\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Individual channel LEDs for real-time input status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane\/Module Consumption: Approximately 300 mA (module plus energized inputs, typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCPU\/Platform Compatibility: PACSystems RX3i CPU required; not intended for Series 90-30 CPUs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New, In Stock, Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOQ: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-point-count 24 VDC signal collection in compact control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring proximity sensors, photoelectric sensors, limit switches, and pushbuttons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReading auxiliary contacts from relays, starters, and interposing interface devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging, material handling, automotive, and general manufacturing automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit I\/O expansion in PACSystems RX3i installations where wiring density is critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519074066605,"sku":"IC694MDL660","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic694mdl660-input-module-wibmgtlzmy3.jpg?v=1766986296"},{"product_id":"ic695alg626-general-electric-pacsystems-rx3i-analog-input-hart-module","title":"IC695ALG626 General Electric PACSystems RX3i Analog Input Hart Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG626 is a PACSystems RX3i analog input module with HART capability available on each channel. It is used to acquire process measurements from common field instruments and to access HART device data for configuration and diagnostics through the control system. The module supports both current and voltage input ranges, enabling flexible integration for mixed-instrument installations.\u003c\/p\u003e\n\u003cp\u003eDesigned for RX3i universal backplanes, the IC695ALG626 supports hot insertion\/removal (with system procedures applied) and does not require hardware jumpers for typical signal range selection, simplifying commissioning and module replacement.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i (IC695 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input HART Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART support\u003c\/td\u003e\n\u003ctd\u003eHART 5.0 on each channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel count\u003c\/td\u003e\n\u003ctd\u003e16 single-ended or 8 differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent inputs\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, ±20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage inputs\u003c\/td\u003e\n\u003ctd\u003e0–10 V, ±10 V, 0–5 V, ±5 V, 1–5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane\u003c\/td\u003e\n\u003ctd\u003eRX3i universal backplane compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eModule status, field status, terminal block status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional diagnostic and maintenance functions may include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-calibration routines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-circuit detection (signal-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable alarms such as high\/low limits and rate-of-change monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlash-based firmware upgrade capability (platform dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess analog input acquisition for transmitters and analog sensors in RX3i PLC\/PAC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART-enabled device integration for instrument diagnostics and secondary variable access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMixed-signal installations requiring both mA and voltage measurement ranges on one module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit projects upgrading I\/O while retaining HART field instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlants needing hot-swap maintainability and clear front-panel status indication for troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519074361517,"sku":"IC695ALG626","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695alg626-analog-input-hart-module-400cech135u.jpg?v=1769676512"},{"product_id":"general-electric-ic695psd140-pacsystems-rx3i-power-supply-module","title":"General Electric IC695PSD140 PACSystems RX3i Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIC695PSD140 is a 40 W DC input power supply for GE PACSystems RX3i racks. It converts 18–30 VDC input into the regulated backplane voltages required by RX3i CPUs and I\/O modules, supporting stable operation in industrial control cabinets and remote I\/O panels.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: General Electric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC695PSD140\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRated Power: 40 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput: 18–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Rails (as specified):\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+5.1 VDC (logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+3.3 VDC (internal module supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+24 VDC (relay\/output support, where applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Configuration:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant \/ load-sharing installations in RX3i universal backplanes (system dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in protection for overload and short-circuit conditions (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupply and Logistics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New, In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrigin: USA, MOQ 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.25 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13.5 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Type: DCS \/ PLC Rack Power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePACSystems RX3i control racks in manufacturing and process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote I\/O panels requiring 18–30 VDC rack power conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant power supply designs for higher availability control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519076360365,"sku":"IC695PSD140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695psd140-pacsystems-rx3i-power-supply-module-ifxdk3ezih4.jpg?v=1766986355"},{"product_id":"pacsystems-rx3i-ic695psa040-40w-universal-power-supply-by-ge-fanuc","title":"PACSystems RX3i IC695PSA040 40W Universal Power Supply by GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA040 is a compact backplane-mounted power supply manufactured by General Electric for PACSystems RX3i control platforms. Designed to deliver stable and regulated power to CPUs and I\/O modules, this unit supports a broad range of AC and DC input voltages, making it suitable for global industrial installations. Its 40-watt capacity is optimized for single-rack or dedicated control configurations where reliability and space efficiency are required.\u003c\/p\u003e\n\u003cp\u003eEngineered specifically for RX3i universal backplanes, the IC695PSA040 provides clean internal logic and auxiliary voltages to ensure consistent system operation and long-term hardware protection.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModule Type: Backplane Power Supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRated Output Power: 40 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e85–264 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100–300 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Voltages:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+3.3 VDC system logic supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+5.1 VDC backplane supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+24 VDC relay and auxiliary output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCompatibility: PACSystems RX3i universal backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: Power, Power Supply Fault, Over Temperature, Overload\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Control: Integrated ON\/OFF switch with protective cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.5 × 13 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA040 is intended for industrial automation systems that require a dedicated and reliable power source for RX3i controllers and I\/O modules. Typical applications include manufacturing automation, process control panels, material handling systems, and utility infrastructure. It is well suited for standalone racks or segmented systems where power demand remains within its rated capacity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519076622509,"sku":"IC695PSA040","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695psa040-power-supply-bbrjr4wx2tz.jpg?v=1766986365"},{"product_id":"ge-he693rtd600t-rtd-temperature-input-module-pacsystems-rx3i","title":"GE HE693RTD600T RTD Temperature Input Module PACSystems RX3i","description":"\u003ch3\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-97 citation-end-97\"\u003eThe GE HE693RTD600T, developed by Horner Electric for the GE PACSystems RX3i platform, is a high-density resistance temperature detector (RTD) input module.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-96 citation-end-96\"\u003eThis precision instrument is engineered to facilitate direct interfacing between industrial temperature sensors and the PLC backbone, eliminating the need for external signal transmitters.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBy providing localized analog-to-digital conversion, the HE693RTD600T ensures that thermal data is transmitted with minimal signal degradation. It is a critical component for automated systems that demand rigorous thermal regulation and high-resolution feedback in real-time processing environments.\u003c\/p\u003e\n\u003ch3\u003eCore Hardware Specifications and Performance Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeamless integration with PACSystems RX3i (and legacy Series 90-30) backplanes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e\u003cspan class=\"citation-95 citation-end-95\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports a diverse range of RTD types, including Platinum (Pt100), Nickel, and Copper probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Logic:\u003c\/strong\u003e\u003cspan class=\"citation-94 citation-end-94\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-resolution analog-to-digital circuitry for superior data granularity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures robust channel-to-backplane isolation to protect the CPU from field-side electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for continuous duty in high-vibration and thermally variable industrial cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoftware-configurable via standard GE programming environments for rapid deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Identifier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHE693RTD600T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 x 8.0 x 29.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturing Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal HS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLifecycle Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActive Production\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePrimary Industrial Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe HE693RTD600T is deployed across a variety of sectors where thermal precision is a prerequisite for safety and product quality:\u003c\/p\u003e\n\u003cp\u003eChemical and Material Processing: Monitoring exothermic reactions in reactor vessels where precise temperature maintenance is vital for chemical stability.\u003c\/p\u003e\n\u003cp\u003eEnergy and Utilities: Tracking bearing and winding temperatures in large motors and generators to prevent overheating and mechanical seizure.\u003c\/p\u003e\n\u003cp\u003eFood and Beverage Production: Managing pasteurization and cooling cycles to ensure compliance with strict health and safety regulations.\u003c\/p\u003e\n\u003cp\u003eHVAC and Building Automation: Centralized temperature monitoring for large-scale industrial climate control and refrigeration systems.\u003c\/p\u003e\n\u003cp\u003eRefining and Oil \u0026amp; Gas: High-reliability thermal data acquisition for distillation columns and pipeline heating systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519077245101,"sku":"HE693RTD600T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-he693rtd600t-rtd-temperature-module-rp0xjcrkenv.jpg?v=1766986390"},{"product_id":"ge-fanuc-ic695cpu315-bb-pacsystems-rx3i-cpu-module","title":"GE Fanuc IC695CPU315-BB PACSystems RX3i CPU Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC695CPU315-BB is a high-speed central processing unit belonging to the GE Fanuc PACSystems RX3i series.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePowered by a 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 GHz Intel Celeron M processor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis controller is designed to handle complex logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emotion control,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand data-intensive applications.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt bridges the gap between traditional PLC reliability and PC-like performance by offering 20 MB of battery-backed user memory alongside 20 MB of non-volatile flash memory for permanent program storage.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe RX3i architecture allows this CPU to communicate over a high-speed PCI bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly increasing data throughput compared to legacy serial backplanes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessor\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 GHz Intel Celeron M for rapid execution of boolean and floating-point logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMemory Resources\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e20 MB User RAM and 20 MB Non-volatile Flash memory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eI\/O Capacity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32,\u003c\/span\u003e\u003cspan class=\"\"\u003e640 discrete inputs\/outputs and 32,\u003c\/span\u003e\u003cspan class=\"\"\u003e768 words of analog I\/O.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Ports\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual integrated serial ports (RS-232 and RS-485) supporting Modbus RTU Slave,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSNP,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Serial I\/O protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProgramming\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 512 program blocks (128 KB max per block) using Ladder Diagram (LD),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunction Block Diagram (FBD),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Structured Text (ST).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Interface\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a high-speed PCI bus for integration with RX3i universal backplanes (12 and 16-slot versions).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eExtensive backward compatibility with Series 90-30 I\/O modules and expansion racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Specifications\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWeight 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e36kg; dimensions 8.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 12.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 x 6 cm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Consumption\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDraws 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e25 Amps at 5V DC and 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Amps at 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e3V DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC695CPU315-BB is a cornerstone for large-scale industrial automation where real-time synchronization and high-speed data processing are paramount.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eAutomotive and Manufacturing\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit manages complex assembly lines and multi-axis motion control.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts robust memory and processing power make it ideal for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eWater and Wastewater Treatment\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilities that require extensive data logging and PID control loops.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFurthermore,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eits backward compatibility makes it a preferred choice for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eSystem Migrations\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing plants to upgrade their processing power while retaining existing 90-30 Series I\/O hardware,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethereby reducing total cost of ownership and minimizing downtime during infrastructure modernizations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45519079145645,"sku":"IC695CPU315-BB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695cpu315-bb-cpu-module-44girhh2awq.jpg?v=1766986413"},{"product_id":"ic695cpu315-pacsystems-rx3i-central-processing-unit-by-ge-fanuc","title":"IC695CPU315 PACSystems RX3i Central Processing Unit by GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC695CPU315 is a RX3i-class PAC Systems central processor module engineered for industrial control and DCS applications. It provides deterministic execution of control logic, manages I\/O scanning and communications, and stores user programs and system data in battery-backed and non-volatile memory. The unit is designed for rack-based PLC\/PAC systems and supports field firmware updates and robust diagnostics for continuous operation.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor: 1.0 GHz Celeron M-class core (embedded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory: 20 MB NVRAM (user data\/program), battery-backed SRAM for real-time variables; typical user memory allocation supports hundreds of program blocks (block size and count subject to configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgram capacity: up to the platform limits (supports large program sets and symbolic variables)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O reservation: discrete and analog I\/O configuration memory reserved per platform conventions (typical reserved areas for I\/O configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial communications: two onboard serial ports configurable for RS-232 and RS-485; supports Serial I\/O, Modbus RTU (slave), SNP and peer protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBus support: PCI v2.2 compliant backplane interface for RX3i racks and compatible expansion modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower consumption: nominally 1.2 A at 5 VDC and 1.0 A at 3.3 VDC (typical operational draw)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental: operating temperature approximately 0–60°C (32–140°F); industrial-grade tolerance for factory environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTiming: precise internal clock with typical accuracy within 0.01% and low daily drift (on the order of seconds\/day)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintainability: field-upgradable firmware, support for GE-approved auxiliary battery packs (e.g., IC695ACC302) for extended data retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance: RoHS-compliant where applicable; HS Code commonly 8537101190 for customs classification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical: weight ~0.36 kg; dimensions ~8.2 × 12.2 × 6 cm; origin: USA; condition: new, in stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary controller for mid-to-large RX3i PAC racks in manufacturing and process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time machine control where deterministic loop times and serial device integration are required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or upgrade path for MARK VLE and related series in retrofit projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGateway and protocol translator in distributed control systems (Modbus\/serial integration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccess control for redundant or multi-rack systems requiring battery-backed data retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIntegration \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRequires RX3i-compatible chassis and backplane; verify PCI addressing and slot assignment before installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall GE-approved battery modules for SRAM retention and follow replacement intervals per site maintenance plans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigure serial port parameters and protocol assignments in the programmer\/HMI before connecting field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow recommended grounding, cable shielding and surge protection practices to protect communications and I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform firmware updates and configuration backups during scheduled maintenance windows to avoid production impact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBasic Specifications (at a glance)\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: IC695CPU315\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: CPU Module (RX3i PAC Systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor: 1.0 GHz Celeron M-class\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory: 20 MB NVRAM + battery-backed SRAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial Ports: 2 (RS-232\/RS-485 capable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance: RoHS (where applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 8.2 × 12.2 × 6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519079899309,"sku":"IC695CPU315","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695cpu315-cpu-module-p4ke2q2feda.jpg?v=1766986445"},{"product_id":"general-electric-ic695niu001-ethernet-network-interface-unit-pacsystems","title":"General Electric IC695NIU001 Ethernet Network Interface Unit PACSystems","description":"\u003ch3 data-start=\"110\" data-end=\"132\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"133\" data-end=\"507\"\u003eThe IC695NIU001 is an Ethernet Network Interface Unit (NIU) used to connect distributed I\/O assemblies to a control system over an Ethernet network. In PACSystems architectures, the NIU functions as a remote I\/O communications node, exchanging I\/O data and status information between networked controllers and the installed I\/O modules once the configuration is established.\u003c\/p\u003e\n\u003cp data-start=\"509\" data-end=\"826\"\u003eThis unit is commonly applied where remote racks or distributed I\/O stations are required to reduce field wiring, extend system reach, and support scalable automation layouts. It is designed for industrial networks where deterministic data exchange and ongoing link diagnostics are important for continuous operation.\u003c\/p\u003e\n\u003ch3 data-start=\"828\" data-end=\"853\"\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul data-start=\"854\" data-end=\"2395\"\u003e\n\u003cli data-start=\"854\" data-end=\"867\"\u003e\n\u003cp data-start=\"856\" data-end=\"867\"\u003eBrand: GE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"868\" data-end=\"898\"\u003e\n\u003cp data-start=\"870\" data-end=\"898\"\u003eProduct Family: PACSystems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"899\" data-end=\"957\"\u003e\n\u003cp data-start=\"901\" data-end=\"957\"\u003eModule Category: Ethernet Network Interface Unit (NIU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"958\" data-end=\"995\"\u003e\n\u003cp data-start=\"960\" data-end=\"995\"\u003eModel \/ Order Number: IC695NIU001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"996\" data-end=\"1076\"\u003e\n\u003cp data-start=\"998\" data-end=\"1076\"\u003ePrimary Function: Ethernet-based remote I\/O interface and data exchange node\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1077\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1079\" data-end=\"1198\"\u003eSupported Architectures (as stated): PACSystems RX3i and Series 90-30 networked I\/O configurations (system-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1200\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1202\" data-end=\"1248\"\u003eNetwork and Protocol Support (as specified):\u003c\/p\u003e\n\u003cul data-start=\"1251\" data-end=\"1464\"\u003e\n\u003cli data-start=\"1251\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1253\" data-end=\"1282\"\u003eEthernet Speed: 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1375\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1375\"\u003eEthernet Global Data (EGD) capability for cyclic data exchange (application-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1378\" data-end=\"1464\"\u003e\n\u003cp data-start=\"1380\" data-end=\"1464\"\u003eProvides continuous communication status reporting for controller-side diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1466\" data-end=\"1767\"\u003e\n\u003cp data-start=\"1468\" data-end=\"1502\"\u003ePort and Communication Features:\u003c\/p\u003e\n\u003cul data-start=\"1505\" data-end=\"1767\"\u003e\n\u003cli data-start=\"1505\" data-end=\"1596\"\u003e\n\u003cp data-start=\"1507\" data-end=\"1596\"\u003eDual Ethernet port design for network connectivity and flexible installation topologies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1599\" data-end=\"1674\"\u003e\n\u003cp data-start=\"1601\" data-end=\"1674\"\u003eAutomatic background handling of I\/O data transfers after configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1677\" data-end=\"1767\"\u003e\n\u003cp data-start=\"1679\" data-end=\"1767\"\u003eStatus visibility allows controller logic to monitor NIU health and network conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1769\" data-end=\"2069\"\u003e\n\u003cp data-start=\"1771\" data-end=\"1794\"\u003eSupply and Logistics:\u003c\/p\u003e\n\u003cul data-start=\"1797\" data-end=\"2069\"\u003e\n\u003cli data-start=\"1797\" data-end=\"1821\"\u003e\n\u003cp data-start=\"1799\" data-end=\"1821\"\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1824\" data-end=\"1850\"\u003e\n\u003cp data-start=\"1826\" data-end=\"1850\"\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1853\" data-end=\"1881\"\u003e\n\u003cp data-start=\"1855\" data-end=\"1881\"\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1907\"\u003e\n\u003cp data-start=\"1886\" data-end=\"1907\"\u003eProduct Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1939\"\u003e\n\u003cp data-start=\"1912\" data-end=\"1939\"\u003eMinimum Order Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1942\" data-end=\"1965\"\u003e\n\u003cp data-start=\"1944\" data-end=\"1965\"\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1968\" data-end=\"1987\"\u003e\n\u003cp data-start=\"1970\" data-end=\"1987\"\u003eWeight: 0.44 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1990\" data-end=\"2026\"\u003e\n\u003cp data-start=\"1992\" data-end=\"2026\"\u003eDimensions: 7.0 × 13.2 × 13.7 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2069\"\u003e\n\u003cp data-start=\"2031\" data-end=\"2069\"\u003eSystem Type: DCS \/ PLC Networked I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2071\" data-end=\"2395\"\u003e\n\u003cp data-start=\"2073\" data-end=\"2093\"\u003eIntegration Notes:\u003c\/p\u003e\n\u003cul data-start=\"2096\" data-end=\"2395\"\u003e\n\u003cli data-start=\"2096\" data-end=\"2168\"\u003e\n\u003cp data-start=\"2098\" data-end=\"2168\"\u003eUsed as part of a configured PACSystems Ethernet remote I\/O solution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2171\" data-end=\"2279\"\u003e\n\u003cp data-start=\"2173\" data-end=\"2279\"\u003eConfiguration, node addressing, and data mapping are completed in the PACSystems engineering environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2282\" data-end=\"2395\"\u003e\n\u003cp data-start=\"2284\" data-end=\"2395\"\u003eNetwork design should follow industrial Ethernet best practices for grounding, segregation, and cable routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2397\" data-end=\"2426\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul data-start=\"2427\" data-end=\"2885\"\u003e\n\u003cli data-start=\"2427\" data-end=\"2520\"\u003e\n\u003cp data-start=\"2429\" data-end=\"2520\"\u003eRemote I\/O stations in manufacturing cells and conveyor systems to reduce home-run wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2521\" data-end=\"2606\"\u003e\n\u003cp data-start=\"2523\" data-end=\"2606\"\u003eDistributed automation skids and packaged systems requiring modular I\/O expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2607\" data-end=\"2689\"\u003e\n\u003cp data-start=\"2609\" data-end=\"2689\"\u003eUtility and water\/wastewater facilities using Ethernet-connected remote panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2690\" data-end=\"2791\"\u003e\n\u003cp data-start=\"2692\" data-end=\"2791\"\u003eRetrofit projects where legacy I\/O and newer PACSystems controllers share a common network design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2792\" data-end=\"2885\"\u003e\n\u003cp data-start=\"2794\" data-end=\"2885\"\u003eSystems requiring network health monitoring and diagnostic visibility from the controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519080259757,"sku":"IC695NIU001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695niu001-ethernet-network-interface-unit-r1p11lu12rq.jpg?v=1766986459"},{"product_id":"general-electric-ic695psd040-pacsystems-rx3i-power-supply-module","title":"General Electric IC695PSD040 PACSystems RX3i Power Supply Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe GE IC695PSD040 is a high-performance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e40-watt DC power supply designed specifically for the PACSystems RX3i Universal Backplane.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides the primary regulated power required for the CPU,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003especialized modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand standard I\/O within a single rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for simplicity and reliability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe IC695PSD040 converts a 24VDC input into the multiple voltage rails needed for backplane logic and internal circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs a non-redundant power solution,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module is intended for single-unit installation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt occupies one slot on the universal backplane and serves as a cost-effective energy source for small to medium-scale automation configurations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features advanced internal diagnostics that integrate with the RX3i CPU to provide real-time status updates and fault reporting,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that power-related events are captured within the system’s diagnostic logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24VDC nominal (Input range:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e18VDC to 30VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Power:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e40 Watts maximum total output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Voltage Rails:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRegulated +5.\u003c\/span\u003e\u003cspan class=\"\"\u003e1VDC for logic; +24VDC for relays and isolated circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConfiguration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSingle-unit operation only (Non-parallel \/ Non-redundant)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSlot Occupancy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSingle slot on the RX3i Universal Backplane (IC695CHSxxx)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtection Circuitry:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in hardware safeguards against overvoltage and overcurrent conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAutomatic power-fail reporting to the system CPU\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHoldup Time:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMinimum 10ms for transient power interruptions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFront-facing terminal strip for secure DC input wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e3 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e26 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eInstallation and System Safety\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC695PSD040 is optimized for standard industrial environments where a stable 24VDC source is available.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain system integrity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is vital to adhere to the single-supply installation rule.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module cannot be wired in parallel with other power supplies on the same backplane; doing so may result in equipment damage or unpredictable system resets.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf the power budget of a single rack exceeds 40W,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eusers should utilize expansion bases or remote I\/O drops to distribute the load.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eFurthermore,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module includes a specialized ground connection to ensure high noise immunity against electromagnetic interference (EMI).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts rugged design and lack of internal fans make it highly durable in dusty or high-vibration industrial settings.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy strictly following the installation guidelines regarding version compatibility—particularly ensuring this 40W unit is not mixed with redundancy-capable modules—operators can guarantee a long service life and stable control system performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519081504941,"sku":"IC695PSD040","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695psd040-rx3i-universal-backplane-power-supply-3g5s4mzcvq5.jpg?v=1766986511"},{"product_id":"general-electric-ic695cru320-pacsystems-rx3i-redundancy-cpu-module","title":"General Electric IC695CRU320 PACSystems RX3i Redundancy CPU Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-2003 citation-end-2003\"\u003eThe GE IC695CRU320 is a high-performance, redundancy-enabled central processing unit designed specifically for the PACSystems RX3i platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-2002 citation-end-2002\"\u003eThis module is the core component for industrial operations requiring zero-downtime tolerance, functioning as a \"Hot Standby\" controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn a redundant configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etwo IC695CRU320 units work in a synchronized primary\/secondary pair.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIf the active processor encounters a fault,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe backup unit assumes control seamlessly,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that critical processes continue without interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-2001 citation-end-2001\"\u003eEquipped with a 1GHz Celeron M processor and a robust PCI-based backplane interface, the IC695CRU320 delivers high-speed logic execution and significant data throughput.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-2000 citation-end-2000\"\u003eIt is engineered to manage complex automation architectures, supporting expansive I\/O counts and sophisticated control algorithms required in power generation, oil and gas, and large-scale water treatment facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessing Speed:\u003c\/strong\u003e\u003cspan class=\"citation-1999 citation-end-1999\"\u003e\u003cspan\u003e \u003c\/span\u003e1GHz Intel Celeron M Processor for rapid logic solving\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-1998\"\u003e\u003c\/span\u003e\u003cstrong\u003eUser Memory:\u003c\/strong\u003e\u003cspan class=\"citation-1998 citation-end-1998\"\u003e\u003cspan\u003e \u003c\/span\u003e64MB of non-volatile user memory for program logic and register data\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSwitchover Time:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUltra-fast redundancy transition within one logic scan (as low as 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e133 ms)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSynchronization Link:\u003c\/strong\u003e\u003cspan class=\"citation-1997 citation-end-1997\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports high-speed data transfer up to 2MB to maintain real-time secondary unit updates\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eI\/O Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32,\u003c\/span\u003e\u003cspan class=\"\"\u003e640 discrete I\/O and 32,\u003c\/span\u003e\u003cspan class=\"\"\u003e640 words of analog I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProgramming Languages:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with Ladder Diagram (LD),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunction Block Diagram (FBD),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStructured Text (ST),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand C-block programming\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-1996\"\u003e\u003c\/span\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan class=\"citation-1996 citation-end-1996\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated RS-232 and RS-485 serial ports; supports Ethernet via rack-mounted modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMigration Support:\u003c\/strong\u003e\u003cspan class=\"citation-1995 citation-end-1995\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a dual-bus backplane that allows for the use of legacy Series 90-30 I\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.36 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Fail-Safe Operation\u003c\/h3\u003e\n\u003cp\u003eThe IC695CRU320 stands out in the PACSystems lineup for its deterministic performance and fault-tolerant design. By utilizing the high-speed PCI bus on the RX3i Universal Backplane, the module achieves significantly faster data exchange rates compared to traditional serial-bus controllers. This architecture allows the system to synchronize massive amounts of process data between the primary and secondary racks in real-time.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-1994 citation-end-1994\"\u003eFrom a maintenance perspective, the module supports \"Hot Swapping,\" allowing hardware replacements without powering down the entire system—a vital feature for mission-critical Distributed Control Systems (DCS).\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-1993 citation-end-1993\"\u003eWith the ability to store up to 512 program blocks, the IC695CRU320 provides the scalability needed for future plant expansions while maintaining the rigorous safety and availability standards required by modern industrial infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519084355757,"sku":"IC695CRU320","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695cru320-cpu-processor-module-fnlczdd3xwk.jpg?v=1766986556"},{"product_id":"general-electric-ic698cpe020-jx-pacsystems-rx7i-central-processing-unit","title":"General Electric IC698CPE020-JX PACSystems RX7i Central Processing Unit","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe GE IC698CPE020-JX is a flagship central processing unit within the PACSystems RX7i family,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eengineered for high-end industrial automation and sophisticated control logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnlike entry-level controllers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis CPU leverages a VME64-based backplane architecture to provide massive data throughput and deterministic performance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically designed to handle large-scale applications requiring rapid instruction execution and the management of high-density I\/O configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eBy utilizing a common control engine across the PACSystems portfolio,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe IC698CPE020-JX allows for seamless application portability and reduced engineering overhead.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis processor is the ideal choice for heavy industrial sectors—including power generation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand complex manufacturing—where high-speed processing and system-wide synchronization are essential for operational safety and efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessing Power:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 GHz Pentium III-class processor (optimized for 800 MHz execution cycles)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMemory Capacity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e64 MB of user memory for logic and data,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupported by 512 MB of internal RAM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating System:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt on a reliable real-time operating system (RTOS) for deterministic task scheduling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-1973\"\u003e\u003c\/span\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003cspan class=\"citation-1973 citation-end-1973 animating\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Ethernet interface (10\/100 Mbps) with support for SRTP and Modbus TCP\/IP protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-1972\"\u003e\u003c\/span\u003e\u003cstrong\u003eBackplane Interface:\u003c\/strong\u003e\u003cspan class=\"citation-1972 citation-end-1972\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for RX7i VME64 standard, ensuring compatibility with high-speed specialized VME cards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProgramming Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Proficy Machine Edition (PME) for ladder logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estructured text,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand C-block programming\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSerial Connectivity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThree isolated serial ports for localized monitoring and programming (RS-232 and RS-485)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStorage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompactFlash slot for permanent non-volatile storage of user programs and data logs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 x 8 x 29.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eAdvanced Performance and Scalability\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC698CPE020-JX distinguishes itself through its ability to manage thousands of I\/O points without degrading cycle times.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe integration of 512 MB of memory ensures that even the most memory-intensive algorithms,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as those used in motion control or complex PID loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erun with precision.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts hardware is physically hardened to endure high-vibration and electromagnetically noisy environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etypical of industrial switchgear or engine control rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eConnectivity is a core strength of this CPU.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWith built-in Ethernet and multiple serial interfaces,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module serves as a powerful communication bridge between the plant floor and supervisory DCS\/SCADA systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFurthermore,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe inclusion of a CompactFlash slot simplifies field updates and disaster recovery by allowing users to maintain a physical backup of the entire control strategy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis combination of processing speed,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eexpansive memory,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand ruggedized hardware ensures that the PACSystems RX7i remains a benchmark for mission-critical automation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519084945581,"sku":"IC698CPE020-JX","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic698cpe020-jx-rx7i-cpu-kvcodemljh2.jpg?v=1766986563"},{"product_id":"ge-ic694mdl754-pacsystem-rx3i-32-point-dc-discrete-output-module","title":"GE IC694MDL754 PACSystem RX3i 32-Point DC Discrete Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL754 is a high-density DC discrete output module used with GE PACSystem RX3i control platforms. It provides 32 positive-logic output points for switching field devices such as solenoids, relays, contactors, indicators, and interposing relays. Outputs are arranged into two electrically isolated banks to improve wiring segregation and simplify power distribution practices in industrial panels.\u003c\/p\u003e\n\u003cp\u003eDesigned for reliable machine and process automation duty, the module includes electronic protection features and point-level LED indication to support rapid commissioning and fault isolation. It installs in a standard rack slot and is suitable for both local racks and remote I\/O stations when used within a compatible RX3i architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: GE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl Platform: PACSystem RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Category: Discrete Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogic Type: Positive logic (sourcing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC694MDL754\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Output Points: 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Grouping: 2 isolated groups, 16 points per group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Voltage Range: 10.2 to 30.0 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal Field Voltage: 12\/24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Current Capacity: Up to 0.75 A per point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush Capability: Up to 3 A for 10 ms (per point)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching Response Time: 0.5 ms (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Current Draw: 300 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel Indication: Individual point status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Features:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit protection with automatic recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvercurrent protection with automatic recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvertemperature protection with automatic recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation and Compatibility:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFits standard rack slot in local CPU base or remote I\/O station\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Block Support: Box-style or spring-style terminal blocks (system-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCPU Firmware Requirement: RX3i CPU firmware v2.90 or higher (as specified)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupply and Logistics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Order Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.25 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.6 × 13.4 × 13.7 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching DC solenoid valves, pneumatic manifolds, and actuator coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDriving interposing relays for higher-power loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOn\/off control of pilot devices, beacons, stack lights, and panel indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete output expansion for packaging, material handling, and process skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement module for installed PACSystem RX3i racks requiring 32-point DC sourcing outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519087272109,"sku":"IC694MDL754","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic694mdl754-discrete-output-module-5bn3i3x0w4c.jpg?v=1766986635"},{"product_id":"general-electric-ic694alg392-fg-pacsystem-rx3i-analog-output-module","title":"General Electric IC694ALG392-FG PACSystem RX3i Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC694ALG392-FG is an analog output module designed for the GE PACSystem RX3i control platform. It provides eight independently configurable analog output channels for delivering accurate voltage or current control signals to field devices. This module is commonly used where precise analog command generation is required for process regulation, motion-related control, and equipment interfacing.\u003c\/p\u003e\n\u003cp\u003eBuilt for continuous industrial operation, the IC694ALG392-FG supports integration with RX3i CPUs and application logic, including PID control routines. Its diagnostic and fail-safe behaviors help maintain stable plant operation, even during power interruptions or wiring faults.\u003c\/p\u003e\n\u003ch3\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: General Electric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl Platform: PACSystem RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Category: Analog Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Number: IC694ALG392-FG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Output Channels: 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal Types: Voltage and Current (software selectable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Voltage Ranges: 0–10 VDC, ±10 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Current Ranges: 0–20 mA, 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Resolution:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e15-bit or 16-bit resolution depending on selected range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eChannel Update Rate: All channels updated within 8 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostic Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-wire detection in current mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule and channel status reporting to the controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Behavior on Power Loss: Holds last commanded output value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical and Mechanical Data:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCondition: Brand New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailability: In Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifecycle Status: Active\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Order Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Type: DCS \/ PLC Control System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.9 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 20.0 × 11.5 × 5.7 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration Notes:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for direct installation in PACSystem RX3i baseplates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with RX3i controllers and application software environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for use with PID control blocks or manual output control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eControl of modulating valves using voltage or 4–20 mA signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput reference generation for variable frequency drives and inverters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog command delivery to actuators, positioners, and process instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation systems requiring high-density analog outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance replacement for installed PACSystem RX3i analog output modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519087501485,"sku":"IC694ALG392-FG","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic694alg392-fg-pacsystem-rx3i-module-ee2z1tp4kqs.jpg?v=1766986646"},{"product_id":"icrxictl000-general-electric-pacsystems-rxi-controller-module","title":"ICRXICTL000 General Electric PACSystems RXi Controller Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE ICRXICTL000 is a PACSystems RXi controller module designed to execute control logic and manage communications for distributed industrial automation systems. It serves as the processing core for an RXi control node, coordinating I\/O updates, task execution, and network data exchange within a rack or remote I\/O architecture. This controller is typically used in panel-mounted automation applications where compact footprint, deterministic control performance, and standardized integration with PACSystems tooling are required.\u003c\/p\u003e\n\u003cp\u003eFor complete installation, the controller may require compatible accessories and rack hardware as defined by the system build, including the ICRXIACCIDM001A accessory referenced for full functionality in some configurations.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part number\u003c\/td\u003e\n\u003ctd\u003eICRXICTL000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule category\u003c\/td\u003e\n\u003ctd\u003eRXi Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform family\u003c\/td\u003e\n\u003ctd\u003ePACSystems RXi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser memory (stated)\u003c\/td\u003e\n\u003ctd\u003e10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity features\u003c\/td\u003e\n\u003ctd\u003eController-level cybersecurity functions (implementation depends on configuration and firmware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead time\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (listing)\u003c\/td\u003e\n\u003ctd\u003e24.4 × 12.7 × 6.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin (listing)\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS code (listing)\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem category\u003c\/td\u003e\n\u003ctd\u003eDCS \/ industrial automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration notes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify rack, power supply, and accessory requirements before commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFirmware and security configuration should be managed by qualified personnel using the appropriate PACSystems engineering environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm network addressing and I\/O scan settings to match the target distributed I\/O topology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control nodes for manufacturing automation lines and machine control skids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control panels requiring a compact PACSystems controller for deterministic I\/O handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial communication gateways where the controller aggregates I\/O and exchanges data with supervisory systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit projects upgrading legacy PLC\/PAC nodes while retaining existing panel space and wiring practices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519088484525,"sku":"ICRXICTL000","price":389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-icrxictl000-rxi-controller-ilqxu4vbrvq.jpg?v=1766986685"},{"product_id":"general-electric-ic695spf002a-rx3i-sfp-transceiver-module","title":"General Electric IC695SPF002A RX3i SFP Transceiver Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-141 citation-end-141\"\u003eThe GE IC695SPF002A is a high-performance Small Form-factor Pluggable (SFP) transceiver designed for the PACSystems RX3i platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides a critical fiber optic interface for industrial communication components, such as the IC695PNS001 PROFINET Scanner. Unlike standard copper connections, the IC695SPF002A enables long-distance, high-speed data transmission while offering total immunity to electromagnetic interference (EMI). This makes it an essential component for distributed I\/O architectures in large-scale industrial facilities where signal integrity over distance is paramount. Engineered for the \"plug-and-play\" requirements of modern DCS and PLC environments, this transceiver allows for flexible network media selection without replacing the primary communication hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IC695SPF002A is distinguished by its industrial reliability and high-speed data throughput:\u003c\/p\u003e\n\u003cp\u003eSeamless Media Integration The transceiver serves as the physical layer interface for RX3i PROFINET controllers and scanners. By utilizing the SFP standard, it allows users to customize their network topology—supporting various fiber types and distances based on specific site requirements—while maintaining the modularity of the RX3i rack system.\u003c\/p\u003e\n\u003cp\u003eIndustrial Environmental Resilience Designed for harsh plant-floor conditions, the IC695SPF002A operates within a wide industrial temperature range. Its rugged metallic housing provides superior heat dissipation and shielding, ensuring that high-speed Ethernet data remains stable even when located near high-voltage motor starters or variable frequency drives.\u003c\/p\u003e\n\u003cp\u003eHot-Swappable Functionality This module supports \"Hot Plugging,\" allowing maintenance personnel to install or replace the transceiver while the system is powered and operational. This feature significantly reduces mean time to repair (MTTR) and prevents unnecessary process shutdowns during network maintenance or cable upgrades.\u003c\/p\u003e\n\u003cp\u003eHigh-Speed Optical Performance The transceiver is optimized for 100Mbps\/1Gbps data rates (depending on the host module configuration), facilitating real-time synchronization between the central CPU and remote I\/O drops.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-140 citation-end-140\"\u003eIt ensures low-latency communication, which is vital for high-speed motion control and safety-related process logic.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGeneral Electric (GE \/ Emerson)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC695SPF002A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSFP Transceiver Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e\u003cspan class=\"citation-139 citation-end-139\"\u003e\u003cspan\u003e \u003c\/span\u003eFiber Optic (SFP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-rate support for Industrial Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.3V (Internal Bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.28 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.8 x 1.3 x 1.2 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Areas\u003c\/h3\u003e\n\u003cp\u003eThe IC695SPF002A is widely deployed in mission-critical network infrastructures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLong-distance communication between the main control room and remote turbine buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing distributed I\/O across large-scale refineries where electrical isolation is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding interference-free data links in electrically noisy processing zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInfrastructure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnecting remote pumping stations or substations to a centralized DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519090221229,"sku":"IC695SPF002A","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic695spf002a-rx3i-sfp-transceiver-module-a45bxnde5eh.jpg?v=1766986755"},{"product_id":"general-electric-ic694alg223-rx3i-16-channel-analog-input-module","title":"General Electric IC694ALG223 RX3i 16-Channel Analog Input Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe GE IC694ALG223 is a high-density analog expansion module designed for the PACSystems RX3i and Series 90-30 controller families.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides 16 single-ended channels specifically engineered for current-loop signal acquisition.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt serves as a precision interface for field transmitters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epressure transducers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand flow meters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting analog current signals into 12-bit digital data for the PLC processor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eOccupying only a single slot in the universal backplane,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe IC694ALG223 maximizes I\/O density while maintaining high signal integrity.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports multiple software-configurable ranges,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding 0 to 20 mA and 4 to 20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith an \"Enhanced\" mode available for 4 to 20 mA signals to facilitate advanced fault detection and diagnostic reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc \/ Emerson (PACSystems)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIC694ALG223\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Channels\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Single-Ended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eResolution\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12-Bit (4 to 5 μA per count depending on range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Signal Ranges\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA Enhanced\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUpdate Rate\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e13 ms (all 16 channels)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eBackplane Current Draw\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e120 mA @ 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExternal Power Requirement\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e65 mA @ 24V DC (for current loops)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommon Mode Rejection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt;70 dB at DC; \u0026gt;70 dB at 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 13 x 13.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e36 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAdvanced Loop Diagnostics\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen operated in the 4-20 mA Enhanced range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module provides automated open-wire detection.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis feature triggers a diagnostic alarm if the current falls below threshold levels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for immediate identification of field wiring failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSuperior Noise Immunity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to operate in electrically congested industrial plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module features robust common-mode rejection and digital filtering,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that electromagnetic interference does not compromise data accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePrecision Conversion\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEach channel utilizes high-speed analog-to-digital conversion with factory calibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a consistent resolution of 4 μA for the 4-20 mA range and 5 μA for the 0-20 mA range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntelligent Power Monitoring\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe IC694ALG223 continuously tracks the status of the user-supplied 24V DC power.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eShould the external power source fail,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module immediately notifies the CPU to prevent invalid data from affecting process logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConfigurable Alarms\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports software-defined high and low alarm limits for each channel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling proactive monitoring of process variables directly at the I\/O level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eApplication Utility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe IC694ALG223 is a standard choice for high-density analog monitoring in various sectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eProcess Industries:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eChemical,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewater treatment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand oil and gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eManufacturing:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring sensor feedback in automated assembly lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eInfrastructure:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnvironmental monitoring and HVAC control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eSCADA Systems:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eActing as a reliable data acquisition node for remote telemetry.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519090876589,"sku":"IC694ALG223","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic694alg223-input-module-lza4302wrzs.jpg?v=1766986781"},{"product_id":"ic695etm001-emerson-pacsystems-rx3i-ethernet-interface-module","title":"IC695ETM001 Emerson PACSystems RX3i Ethernet Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-583 citation-end-583\"\u003eThe IC695ETM001 is a high-performance communication expansion module designed for the Emerson (formerly GE Fanuc) PACSystems RX3i controller platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-582 citation-end-582\"\u003eThis module serves as a primary network interface, enabling the RX3i CPU to communicate over industrial Ethernet networks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-581 citation-end-581\"\u003eEquipped with an independent 200 MHz processor, the IC695ETM001 handles complex communication tasks without taxing the main controller's CPU, ensuring high-speed data throughput and system stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-580 citation-end-580\"\u003eThis single-slot module features an integrated Ethernet switch with two auto-sensing 10\/100 Mbps ports.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-579 citation-end-579\"\u003eThese dual ports support daisy-chain network topologies, which significantly reduces the cost and complexity of wiring by allowing multiple controllers or I\/O devices to be linked in a series without requiring external switches.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Speed:\u003c\/strong\u003e\u003cspan class=\"citation-578 citation-end-578\"\u003e\u003cspan\u003e \u003c\/span\u003e200 MHz Dedicated Ethernet Processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-577\"\u003e\u003c\/span\u003e\u003cstrong\u003eInterface Ports:\u003c\/strong\u003e\u003cspan class=\"citation-577 citation-end-577\"\u003e\u003cspan\u003e \u003c\/span\u003eTwo (2) 10BaseT \/ 100BaseTX RJ-45 ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Interface:\u003c\/strong\u003e\u003cspan class=\"citation-576 citation-end-576\"\u003e\u003cspan\u003e \u003c\/span\u003eOne (1) RS-232 Station Manager port (9-pin D-connector)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocols Supported:\u003c\/strong\u003e\u003cspan class=\"citation-575 citation-end-575\"\u003e\u003cspan\u003e \u003c\/span\u003eSRTP, Modbus TCP, Ethernet Global Data (EGD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEEE 802.3 and 802.2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-574\"\u003e\u003c\/span\u003e\u003cstrong\u003eData Rates:\u003c\/strong\u003e\u003cspan class=\"citation-574 citation-end-574\"\u003e\u003cspan\u003e \u003c\/span\u003e10\/100 Mbps (Auto-negotiating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-573\"\u003e\u003c\/span\u003e\u003cstrong\u003eBaud Rate (Serial):\u003c\/strong\u003e\u003cspan class=\"citation-573 citation-end-573\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable from 1200 to 115200 bps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-slot occupancy in RX3i Universal Backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-572\"\u003e\u003c\/span\u003e\u003cstrong\u003eOperating Current:\u003c\/strong\u003e\u003cspan class=\"citation-572 citation-end-572\"\u003e\u003cspan\u003e \u003c\/span\u003e840 mA @ 3.3V DC; 614 mA @ 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-572 citation-end-572\"\u003e\u003cstrong\u003eDimentions\u003c\/strong\u003e:\u003cspan\u003e12.1x5.2x16.6cm\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.34 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Communication and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe IC695ETM001 facilitates seamless vertical and horizontal integration across the automation pyramid.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-571 citation-end-571\"\u003eBy supporting EGD, the module allows for high-efficiency \"produce\/consume\" data exchange between PACSystems, Series 90-30, and VersaMax controllers.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eFor HMI, SCADA, and programming software connections, the module utilizes the Service Request Transport Protocol (SRTP).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eBeyond standard data exchange, the module includes a dedicated Station Manager port.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-570 citation-end-570\"\u003eThis RS-232 interface provides engineers with a deep-level diagnostic toolset for system configuration, firmware updates, and troubleshooting network traffic.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis dual-layered approach—combining high-speed Ethernet for production data and a stable serial line for management—ensures maximum uptime in demanding discrete and process automation environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45519118762157,"sku":"IC695ETM001","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/emerson-ic695etm001-ethernet-module-ftpblputdxi.jpg?v=1766987336"}],"url":"https:\/\/www.maxwellplc.com\/collections\/ge-pacsystem-rx3i.oembed","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}