{"title":"Eaton","description":"\u003cp\u003eAs a globally recognized leader in power management,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEaton\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the foundational technology for modern infrastructure. This comprehensive collection serves as a premier B2B hub for high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical and industrial components\u003c\/strong\u003e, engineered to optimize safety, reliability, and energy efficiency across multiple sectors.\u003c\/p\u003e\n\u003cp\u003eOur inventory spans the full spectrum of Eaton’s engineering excellence:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution \u0026amp; Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure system integrity with industrial-grade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emolded case circuit breakers (MCCB)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eswitchgear\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epanelboards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for heavy-duty protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Power Quality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain 100% uptime for data centers and healthcare facilities with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEaton UPS systems\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePDUs\u003c\/strong\u003e, and advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esurge protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Control \u0026amp; Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStreamline production lines with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor starters\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evariable frequency drives (VFDs)\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI panels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebuilt for harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFluid Power \u0026amp; Hydraulics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSource authentic\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVickers by Eaton\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epumps,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAeroquip hoses\u003c\/strong\u003e, and high-pressure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalves\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor construction and mining machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAerospace Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotion control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecomponents that meet rigorous international aviation and defense standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe understand the complexities of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial procurement\u003c\/strong\u003e. Whether you are managing a large-scale utility project or maintaining a manufacturing facility, we offer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etechnical cross-referencing\u003c\/strong\u003e, bulk volume pricing, and global logistics support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubmit your RFQ (Request for Quote)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etoday to receive a professional technical proposal. Our team of specialists is ready to assist with detailed specifications and lead-time coordination for all your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEaton power management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eneeds.\u003c\/p\u003e","products":[{"product_id":"eaton-dilm12-1024vdc-contactor-276845-3-pole-5-5kw-24v-dc-coil","title":"Eaton DILM12-10(24VDC) Contactor 276845 3-Pole 5.5kW 24V DC Coil","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton DILM12-10(24VDC), part of the renowned Moeller series, delivers high-efficiency control for three-phase motor applications up to 5.5 kW (400V). This compact 3-pole contactor excels in modern industrial automation by offering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIE3-ready\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eperformance, specifically designed to handle the higher starting currents of premium efficiency motors. Operating on a 24V DC control voltage, this unit features an integrated varistor suppressor circuit that protects your PLC outputs and control electronics from harmful inductive voltage spikes. Whether driving centrifugal pumps, conveyor belts, or heavy-duty fans, the DILM12-10 ensures long-term switching reliability with a mechanical lifespan exceeding 10 million operations. Its robust design supports high-frequency switching and maintains stable isolation in demanding manufacturing environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eIntegrated Safety and Suppression\u003c\/h3\u003e\n\u003cp\u003eEaton simplifies your control cabinet assembly by building the varistor suppressor directly into the contactor. This hardware configuration eliminates the need for external protection modules, reducing both wiring time and component costs while providing immediate protection against transients.\u003c\/p\u003e\n\u003ch3\u003eSmartWire-DT Compatibility\u003c\/h3\u003e\n\u003cp\u003eThis contactor integrates seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSmartWire-DT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology when used with the DIL-SWD module. This digital communication capability transforms a simple switching device into a smart component, allowing the control system to monitor contactor status and health through a single cable, drastically reducing I\/O requirements.\u003c\/p\u003e\n\u003ch3\u003eIE3 Efficiency Compliance\u003c\/h3\u003e\n\u003cp\u003eAs energy standards evolve, the DILM12-10 remains a future-proof choice. Its magnetic system and contact materials are optimized to withstand the unique electrical stresses of IE3 efficiency class motors, preventing premature contact welding and ensuring high-frequency switching stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Operational Current (AC-3, 400V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Rating (AC-3, 380V\/400V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoil Actuating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAuxiliary Contact Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 N\/O (Normally Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Lifespan\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000,000 Operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Frequency (Mechanical)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9,000 Operations\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45mm x 68mm x 75mm (Base Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.296 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC\/EN 60947, VDE 0660, UL, CSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003ch3\u003eTerminal and Wiring Precision\u003c\/h3\u003e\n\u003cp\u003eUtilize the M3.5 screw terminals for secure connections. We recommend a tightening torque of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.2 Nm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing a Pozidriv Size 2 screwdriver. The contactor accepts solid or flexible cables with ferrules ranging from 0.75 mm² to 4 mm², ensuring flexible integration into various cabinet layouts.\u003c\/p\u003e\n\u003ch3\u003eDC Power Quality\u003c\/h3\u003e\n\u003cp\u003eThe 24V DC coil requires a smoothed two-phase bridge rectifier or a three-phase rectifier to ensure stable pick-up (0.8 - 1.1 x Uc). For optimal reliability, maintain an ambient temperature between -25°C and +60°C.\u003c\/p\u003e\n\u003ch3\u003eSuppressor Circuitry\u003c\/h3\u003e\n\u003cp\u003eBecause this model includes a built-in varistor suppressor, you do not need to install additional RC elements or diodes across the coil. This prevents back-EMF from damaging sensitive transistor outputs on your PLC or DCS system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe Eaton DILM12-10 stands out in extreme industrial environments due to its high resistance to mechanical shock (10g for main contacts) and its wide climatic proofing range. It functions perfectly in both constant and cyclic damp heat conditions per IEC 60068 standards. The \"XTC\" alternate catalog number ensures global interchangeability, allowing engineers to standardize this model across international projects. Furthermore, its finger and back-of-hand proof design (EN 50274) provides a safe interface for maintenance personnel during commissioning and troubleshooting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. We utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static and vibration-resistant packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure the contactor's internal mechanical integrity remains intact during transit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the DILM12-10(24VDC) compatible with older DIL series contactors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, Eaton maintains a high degree of backward compatibility. You can use standard auxiliary contact modules such as DILM32-XHI or DILA-XHI to expand your signaling logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I control this contactor directly from a 24V DC PLC output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Absolutely. With a pick-up power consumption of only 4.5W, most high-current PLC transistor outputs can drive this contactor directly, though you should always verify your PLC's maximum current per point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What does \"IE3-Ready\" mean for this specific contactor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: It means the contactor is physically designed to handle the high inrush currents typical of premium-efficiency motors without contact pitting or welding, ensuring a longer service life compared to standard contactors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does this model require an external surge suppressor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: No. This specific model (276845) includes an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated varistor suppressor\u003c\/strong\u003e, providing built-in protection against voltage spikes.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45952955416749,"sku":"DILM12-10","price":25.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DILM12-10_1.jpg?v=1777277260"},{"product_id":"eaton-easy-e4-uc-12rc1-control-relay-197211-12-24v-dc-24v-ac-ethernet","title":"Eaton EASY-E4-UC-12RC1 Control Relay 197211 12\/24V DC 24V AC Ethernet","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton EASY-E4-UC-12RC1 acts as the central intelligence for localized automation, effectively bridging the gap between traditional relays and complex PLCs. This ultra-compact control relay empowers engineers to implement sophisticated logic across a broad voltage spectrum, supporting 12\/24 V DC and 24 V AC power environments. Featuring an integrated monochrome display and an on-board Ethernet interface, the easyE4 enables real-time status monitoring and seamless vertical integration into IIoT frameworks. Unlike basic logic modules, this device facilitates high-speed data transfer and networking via Modbus TCP, allowing for coordinated control between multiple easyE4 units or upstream SCADA systems. With 8 digital inputs—4 of which function as high-precision 12-bit analog inputs—and 4 robust relay outputs, it provides the versatile I\/O density required for lighting, HVAC, and specialized machine control.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eMulti-Protocol Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe integrated RJ45 Ethernet port transforms the easyE4 from a standalone controller into a networked node. It supports Modbus TCP client\/server roles, allowing the unit to exchange data with HMI panels, frequency drives, and other PLC brands. The built-in web server enables remote diagnostic access through standard web browsers, reducing onsite maintenance requirements.\u003c\/p\u003e\n\u003ch3\u003eHybrid Input Flexibility\u003c\/h3\u003e\n\u003cp\u003eThis hardware architecture optimizes I\/O usage by providing four multi-functional inputs. Users configure these terminals as standard 24V digital signals or as 0-10V analog channels with 12-bit resolution. This eliminates the need for separate analog expansion modules in small-scale applications such as pressure monitoring or temperature regulation.\u003c\/p\u003e\n\u003ch3\u003eExpandable Modular Architecture\u003c\/h3\u003e\n\u003cp\u003eThe EASY-E4-UC-12RC1 operates as a master unit that accepts up to 11 additional I\/O expansion modules via the EASY-E4-CONNECT1 connector. This allows the system to scale up to 188 I\/O points, protecting your initial hardware investment as project requirements grow.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\/24 V DC or 24 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Inputs I1 - I8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Configurable on I5, I6, I7, I8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Bit (0 - 4095 range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Relay Outputs (8A continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45, 10\/100 Mbit\/s (Modbus TCP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonochrome LCD (6 lines x 16 characters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated with capacitor backup\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 °C to 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e71.5 mm x 90 mm x 58 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eEthernet Connectivity and Shielding\u003c\/h3\u003e\n\u003cp\u003eWhen utilizing the Ethernet port for industrial communication, we recommend using CAT5e or higher shielded cables. For high-speed counter functions (up to 10 kHz), keep signal wiring below 20 meters and utilize screened cables to prevent electromagnetic interference from surrounding power lines.\u003c\/p\u003e\n\u003ch3\u003ePower Supply and Fusing\u003c\/h3\u003e\n\u003cp\u003eEnsure the power supply remains within the permissible range of 10.2 - 28.8 V DC or 20.4 - 26.4 V AC. To protect the internal relay contacts from high inrush currents or short circuits, install a B16 miniature circuit breaker or a slow-blow 8A fuse on the output lines.\u003c\/p\u003e\n\u003ch3\u003eMounting and Heat Dissipation\u003c\/h3\u003e\n\u003cp\u003eSecure the unit to a standard 35mm DIN rail using the integrated mounting clips. While the device supports both vertical and horizontal mounting, vertical orientation facilitates natural convection. Maintain at least 10mm of clearance from adjacent high-heat components to ensure the LCD remains clearly legible.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe EASY-E4-UC-12RC1 excels in environments where reliability and small-scale complexity intersect. Its high mechanical shock resistance (15g\/11ms) ensures stable operation in mobile machinery and vibratory conveyor systems. The unit’s ability to handle three different supply voltages (12VDC, 24VDC, 24VAC) makes it a universal replacement part for diverse global fleets, significantly reducing spare part inventory. By utilizing the EasySoft 7 software environment, engineers choose between four programming languages—including ST (Structured Text) and EDP—providing the flexibility to implement advanced math functions or simple ladder logic within the same industrial-grade housing.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. We utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatic-shielded, impact-resistant packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect the internal Ethernet circuitry and LCD display during international transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can I use the analog inputs when the unit is powered by 24V AC?\u003c\/p\u003e\n\u003cp\u003eA1: No. Analog input functionality (0-10V) is only available when the device is supplied with 12V DC or 24V DC. For AC-powered applications requiring analog sensing, an expansion module is required.\u003c\/p\u003e\n\u003cp\u003eQ2: How many expansion modules can I connect to this basic EASY-E4 unit?\u003c\/p\u003e\n\u003cp\u003eA2: You can connect up to 11 expansion modules to a single EASY-E4-UC-12RC1 basic device, allowing for a mix of digital, analog, and temperature measurement expansions.\u003c\/p\u003e\n\u003cp\u003eQ3: Is the Ethernet port compatible with PROFINET?\u003c\/p\u003e\n\u003cp\u003eA3: The easyE4 natively supports Modbus TCP and Ethernet\/IP via specific configurations. While it does not support the PROFINET protocol directly, it communicates with PROFINET environments through a gateway or by using Modbus TCP data exchange.\u003c\/p\u003e\n\u003cp\u003eQ4: What happens to the program if the power fails?\u003c\/p\u003e\n\u003cp\u003eA4: The easyE4 stores the user program in non-volatile memory. The real-time clock is maintained by an internal high-capacity capacitor, providing typical backup for several hours without a battery.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45952961151149,"sku":"EASY-E4-UC-12RC1","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/EASY-E4-UC-12RC1_1.jpg?v=1777278210"},{"product_id":"eaton-faz-c10-3-miniature-circuit-breaker-278869-3-pole-10a-type-c","title":"Eaton FAZ-C10\/3 Miniature Circuit Breaker 278869 3-Pole 10A Type C","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton FAZ-C10\/3 stands as a premier solution for overcurrent and short-circuit protection in complex industrial power distribution systems. This 3-pole miniature circuit breaker features a Type C tripping characteristic, specifically engineered to handle moderate inductive loads where medium inrush currents occur, such as small motor starters and control transformer circuits. Unlike standard residential breakers, the FAZ series provides superior current-limiting performance (Class 3), significantly reducing the thermal and mechanical stress on downstream components during a fault. Its robust 10A rated capacity and high-quality switching mechanism ensure maximum uptime for critical machinery, shielding your infrastructure from catastrophic electrical failures while maintaining a compact DIN-rail footprint.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003ePrecise Tripping Mechanism\u003c\/h3\u003e\n\u003cp\u003eThe Type C release characteristic provides a magnetic trip threshold between 5 and 10 times the rated current. This precision prevents nuisance tripping during the startup phase of inductive equipment while maintaining an instantaneous response to genuine short-circuit events, safeguarding sensitive electronics and heavy-duty industrial hardware alike.\u003c\/p\u003e\n\u003ch3\u003eSuperior Current Limitation\u003c\/h3\u003e\n\u003cp\u003eAs a Current Limiting Class 3 device, the FAZ-C10\/3 rapidly extinguishes the electrical arc during a fault. This ultra-fast disconnection minimizes the let-through energy, protecting cable insulation and ensuring the longevity of connected industrial sensors, PLC modules, and power supplies.\u003c\/p\u003e\n\u003ch3\u003eModular Flexibility\u003c\/h3\u003e\n\u003cp\u003eThe FAZ hardware platform supports extensive field-mountable accessories. Engineers can easily integrate auxiliary contacts, trip signal switches, or shunt trips to incorporate the breaker into remote monitoring and automated safety shutdown sequences within a broader SCADA or DCS architecture.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType C (Medium Inrush)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage (Un)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e440 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Limiting Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Finger Proof)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWidth (Division Units)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 MU (52.5 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eTerminal Security and Torque\u003c\/h3\u003e\n\u003cp\u003eThe FAZ-C10\/3 features twin-purpose terminals that accommodate both busbars and cables. For a high-integrity connection, ensure all screw terminals are tightened to a torque of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.4 Nm\u003c\/strong\u003e. Proper torque prevents localized overheating at the connection point, which is a common cause of premature failure in high-vibration industrial environments.\u003c\/p\u003e\n\u003ch3\u003eThermal Derating Considerations\u003c\/h3\u003e\n\u003cp\u003eWhen mounting multiple breakers side-by-side in a control cabinet, engineers must account for heat dissipation. If the ambient temperature exceeds\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30°C\u003c\/strong\u003e, apply a derating factor to the rated current. Ensure a minimum clearance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom non-ventilated cabinet walls to facilitate natural convection.\u003c\/p\u003e\n\u003ch3\u003eBusbar Integration\u003c\/h3\u003e\n\u003cp\u003eThe design allows for the use of standard Z-GV busbars on either the top or bottom terminals. This bi-directional feed capability simplifies the wiring of multi-circuit distribution boards, reducing cable clutter and improving the overall clarity of the electrical assembly.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe FAZ-C10\/3 excels in extreme commercial and industrial environments where reliability is non-negotiable. Its high-quality contact material and arc-chute design enable consistent performance under high-duty cycles. With an overvoltage category of III and pollution degree 2 rating, this breaker maintains its dielectric strength even in atmospheres containing dust or light humidity. Furthermore, the toggle position provides a clear visual indication of the circuit status (Red\/Green), allowing maintenance teams to identify tripped circuits instantly, thereby reducing MTTR (Mean Time To Repair) during facility outages.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. We dispatch all units in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static and impact-resistant packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin original factory-sealed boxes to guarantee absolute technical integrity upon arrival.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What is the main difference between a Type B and Type C breaker for my system?\u003c\/p\u003e\n\u003cp\u003eA1: Type B breakers trip between 3-5 times the rated current and are for resistive loads. The Type C (FAZ-C10\/3) trips between 5-10 times the rated current, making it essential for circuits with small motors or transformers that have moderate inrush current.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this FAZ-C10\/3 for DC applications?\u003c\/p\u003e\n\u003cp\u003eA2: While primarily designed for AC, the FAZ series is rated for specific DC voltages (typically up to 60V per pole). For high-voltage DC circuits, we recommend utilizing the FAZ-NA or specialized DC-rated models to ensure proper arc extinction.\u003c\/p\u003e\n\u003cp\u003eQ3: Does the breaker require a specific mounting orientation?\u003c\/p\u003e\n\u003cp\u003eA3: The FAZ-C10\/3 is designed for standard vertical or horizontal DIN-rail mounting. Its performance remains consistent regardless of orientation, provided that adequate ventilation and clearance are maintained for heat dissipation.\u003c\/p\u003e\n\u003cp\u003eQ4: What is the maximum breaking capacity (Icu) of this model?\u003c\/p\u003e\n\u003cp\u003eA4: The FAZ-C10\/3 typically offers a breaking capacity of 10 kA according to IEC\/EN 60947-2, making it suitable for industrial branch circuit protection where higher fault currents may occur.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45952969310381,"sku":"FAZ-C10\/3","price":79.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/FAZ-C103_1.jpg?v=1777279262"},{"product_id":"eaton-m22-pv-kc11-iy-emergency-stop-pushbutton-surface-mount-1no-1nc","title":"Eaton M22-PV\/KC11\/IY Emergency Stop Pushbutton Surface Mount 1NO\/1NC","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton M22-PV\/KC11\/IY provides a critical safety interface for industrial machinery, offering a complete, surface-mounted emergency stop solution. Part of the elite RMQ-Titan M22 series, this unit features a highly visible red mushroom actuator housed in a rugged yellow enclosure, ensuring immediate identification during emergency scenarios. Unlike modular panel-mount components, this \"ready-to-use\" assembly integrates the 1NO\/1NC contact block directly into a durable plastic housing, making it ideal for decentralized safety control. The pull-to-release mechanism guarantees that the machine remains in a safe state until manual intervention occurs, while the positive opening contacts ensure the circuit breaks even in the event of minor contact welding. This switch safeguards operators in diverse environments, from automated packaging lines to heavy-duty CNC processing centers.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eIntegrated Safety Housing\u003c\/h3\u003e\n\u003cp\u003eThe IY-suffix enclosure offers a comprehensive IP66 protection rating, shielding the internal contacts from high-pressure water jets and industrial dust. This standalone configuration allows for mounting directly onto machine frames or walls, eliminating the need for additional customized panel cutouts and simplifying the electrical layout.\u003c\/p\u003e\n\u003ch3\u003ePositive Opening Contacts\u003c\/h3\u003e\n\u003cp\u003eThis unit utilizes M22-K11 contact elements that adhere strictly to IEC\/EN 60947-5-1 standards for positive opening. The mechanical design forces the NC (Normally Closed) contact to open through a direct drive mechanism, providing a failsafe shutdown even if mechanical fatigue or electrical surges attempt to stick the contacts together.\u003c\/p\u003e\n\u003ch3\u003eGlobal Compliance Architecture\u003c\/h3\u003e\n\u003cp\u003eEaton engineers this switch to meet virtually every major international standard, including UL 508 and CSA-C22.2. This universal certification allows machine builders to export equipment globally without the need for regional safety redesigns, ensuring the M22-PV\/KC11\/IY remains a standard specification for international OEM projects.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eActuator Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePull-to-Release (Mushroom Head)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 NO (Normally Open) \/ 1 NC (Normally Closed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eActuating Force\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V AC \/ 110 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Contact Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Grade Impact-Resistant Plastic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66 \/ NEMA 4X, 13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Lifespan\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 100,000 Operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e72 mm (2.83 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mm (3.15 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm (3.94 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003ch3\u003eSurface Mounting and Entry\u003c\/h3\u003e\n\u003cp\u003eMount the enclosure using the pre-drilled internal fixing holes to ensure maximum stability. The housing features metric knockouts for M20 or M25 cable glands. We recommend using high-quality cable glands to maintain the IP66 seal, especially in washdown or oil-mist environments.\u003c\/p\u003e\n\u003ch3\u003eWiring and Contact Logic\u003c\/h3\u003e\n\u003cp\u003eConnect the safety-critical shutdown loop to the NC contact (Terminals 11-12) and use the NO contact (Terminals 23-24) for PLC feedback or status signaling. Ensure all screw terminals are tightened to the specified torque of 0.8 Nm to prevent loosening due to machine vibration.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and Testing\u003c\/h3\u003e\n\u003cp\u003ePerform a physical \"trip and reset\" test during every shift change. The pull-to-release action should be smooth and require a deliberate upward force. Inspect the yellow housing for any cracks or chemical degradation if the unit is installed in environments with harsh cleaning agents or cutting fluids.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe M22-PV\/KC11\/IY excels in high-reliability applications where accidental reset is a primary concern. The mushroom head is designed to be tamper-proof, requiring a deliberate pull action that cannot be triggered by simple vibration or incidental contact. Its RMQ-Titan heritage ensures that the silver-alloy contacts maintain low contact resistance over years of service, preventing signal loss in low-voltage safety PLC loops. Furthermore, the modular nature of the internal K-series contacts allows for easy field replacement or reconfiguration without discarding the entire enclosure, significantly lowering the total cost of ownership (TCO) for facility maintenance.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. We dispatch all units in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static and impact-resistant packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect the mechanical actuator and internal contact blocks during transit.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Does this unit include the yellow enclosure, or is it just the button?\u003c\/p\u003e\n\u003cp\u003eA1: The M22-PV\/KC11\/IY is a complete \"all-in-one\" solution. It includes the red mushroom actuator, the 1NO\/1NC contact blocks, and the yellow surface-mount enclosure.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I add more contact blocks to this specific enclosure?\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the IY enclosure is designed to accommodate additional M22-K series contact blocks if your safety logic requires more than two circuits (e.g., adding a second NC for redundancy).\u003c\/p\u003e\n\u003cp\u003eQ3: What is the difference between \"Pull-to-Release\" and \"Turn-to-Release\"?\u003c\/p\u003e\n\u003cp\u003eA3: Pull-to-release (as seen on this model) requires a vertical pull to reset the switch. This is often preferred in environments where a twisting motion might be difficult for an operator wearing heavy industrial gloves.\u003c\/p\u003e\n\u003cp\u003eQ4: Is this switch suitable for outdoor use?\u003c\/p\u003e\n\u003cp\u003eA4: Yes, the IP66 rating and high-grade plastic construction make it suitable for outdoor applications, as it resists UV exposure and common environmental contaminants.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45952995852461,"sku":"M22-PV\/KC11\/IY","price":24.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/M22-PVKC11IY-1.jpg?v=1777281121"},{"product_id":"eaton-nzmn2-af100-na-molded-case-circuit-breaker-269182-100a-3-pole","title":"Eaton NZMN2-AF100-NA Molded Case Circuit Breaker 269182 100A 3-Pole","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton NZMN2-AF100-NA represents the pinnacle of circuit protection for North American industrial power distribution systems. As a critical component in high-demand environments, this NZM2 frame molded case circuit breaker (MCCB) provides high-level switching capacity and reliable overload protection for feeders and branch circuits. Engineers specifically select the NZM series for its ability to manage heavy electrical loads in demanding machinery and control panels. While standard breakers struggle in high-density industrial settings, the NZMN2-AF100-NA utilizes a specialized thermal-magnetic trip unit to maintain system stability. Its robust 50 kAIC interrupt rating at 480V ensures that the breaker effectively clears high-energy faults, safeguarding your downstream motors, control cabinets, and expensive automation hardware from catastrophic thermal damage.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eGlobal Compatibility \u0026amp; UL Compliance\u003c\/h3\u003e\n\u003cp\u003eThe \"NA\" suffix signifies that this unit meets stringent North American UL 489 standards while maintaining IEC compatibility. This dual-certification allows international OEMs to standardize their panel designs for export to the US and Canadian markets without switching hardware platforms.\u003c\/p\u003e\n\u003ch3\u003ePrecision Short-Circuit Management\u003c\/h3\u003e\n\u003cp\u003eThe adjustable short-circuit release ranges from 600A to 1000A, providing localized control over the magnetic trip threshold. This flexibility allows electrical engineers to fine-tune the protection curve to accommodate high inrush currents from transformers or large motors, preventing nuisance tripping during system startup.\u003c\/p\u003e\n\u003ch3\u003eOptimized NZM2 Frame Design\u003c\/h3\u003e\n\u003cp\u003eEaton's NZM2 architecture balances space-saving compactness with heavy-duty performance. The frame supports a wide array of field-mountable accessories, including remote motor operators and undervoltage releases, allowing the NZMN2-AF100-NA to integrate seamlessly into complex safety interlocking systems and remote-control power grids.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterrupt Rating (480V AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 kAIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e690 V AC \/ 750 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 A (Fixed AF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort-Circuit Adjustment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 - 1000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistribution \/ Feeder Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e105 mm (4.13 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e184 mm (7.24 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e103 mm (4.05 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.86 kg (4.1 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eTerminal Connection Integrity\u003c\/h3\u003e\n\u003cp\u003eStandard installation requires the use of the front screw terminals. Ensure all conductor connections meet the required torque specifications to prevent high-resistance heating. We recommend inspecting these connections annually with infrared thermography to ensure long-term reliability in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eMounting Orientation and Clearance\u003c\/h3\u003e\n\u003cp\u003eThe NZMN2-AF100-NA supports various mounting positions, including vertical and horizontal. However, to maintain the 50 kAIC interrupt rating, you must adhere to the minimum safety clearances specified in the Eaton technical manual. This ensures adequate space for arc gas venting during a major fault event.\u003c\/p\u003e\n\u003ch3\u003eDC Application Wiring\u003c\/h3\u003e\n\u003cp\u003eWhen applying this breaker to a 750V DC circuit, correct polarity and series connection of the poles are mandatory. Failure to follow the DC wiring diagrams will compromise the arc-extinction capabilities of the breaker, potentially leading to equipment failure during a DC fault.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe NZMN2-AF100-NA excels in extreme industrial climates where thermal stability is paramount. The internal components utilize high-grade materials resistant to chemical corrosion and atmospheric aging, ensuring the trip curve remains accurate over years of service. Its seamless compatibility with the Eaton \"Rocker Lever\" and motor drive systems allows for easy manual or automated switching in marshalling cabinets. By choosing this model, procurement managers secure a component with a proven MTBF (Mean Time Between Failure) that exceeds standard commercial alternatives, making it the definitive choice for facilities where operational downtime costs thousands of dollars per hour.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS. We utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheavy-duty, impact-resistant packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand moisture-barrier seals to ensure your MCCB arrives in perfect factory condition, ready for immediate installation.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Does the \"AF\" in the model name mean the overload setting is fixed?\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the AF (Adjustable-Fixed) designation indicates a fixed thermal overload setting of 100A, while providing an adjustable magnetic short-circuit range (600-1000A) to handle varying inrush currents.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this breaker for a 600V system in Canada?\u003c\/p\u003e\n\u003cp\u003eA2: Absolutely. The NZMN2-AF100-NA is UL Listed and rated for voltages up to 600V (and 690V IEC), making it fully compliant for industrial use across North America and international sites.\u003c\/p\u003e\n\u003cp\u003eQ3: Is the handle included, or do I need to buy a separate rocker lever?\u003c\/p\u003e\n\u003cp\u003eA3: The standard breaker includes the internal toggle. However, for door-mounted applications or motor-driven control, you will need a separate rotary handle or motor operator accessory.\u003c\/p\u003e\n\u003cp\u003eQ4: What is the difference between NZMN and NZMS series?\u003c\/p\u003e\n\u003cp\u003eA4: The \"N\" in NZMN signifies the \"Normal\" switching capacity (50 kAIC), whereas the \"S\" series typically offers higher interrupt ratings for systems with very high prospective short-circuit currents.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45952998211757,"sku":"NZMN2-AF100-NA","price":59.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NZMN2-AF100-NA_1.jpg?v=1777281640"},{"product_id":"eaton-xv-303-10-c00-a00-1c-touch-panel-hmi-179662-plc-integrated-controller","title":"Eaton XV-303-10-C00-A00-1C Touch Panel HMI 179662 PLC-Integrated Controller","description":"\u003ch2 data-path-to-node=\"6\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe Eaton XV-303-10-C00-A00-1C represents a high-performance convergence of visualization and control logic within a single industrial-grade unit. This 10.1-inch widescreen touch panel features advanced capacitive multi-touch technology, providing an intuitive, smartphone-like user experience for complex machinery interfaces. Engineered for high-speed automation, the XV303 integrates a powerful PLC controller that utilizes CODESYS programming, allowing it to manage complex motion control and data processing tasks simultaneously. Its high-resolution glass display ensures crystal-clear visualization of process parameters even in harsh factory lighting, while the robust hardware architecture facilitates seamless communication with factory-wide networks. This specific unit arrives in mint condition, having undergone rigorous functional testing to guarantee immediate operational readiness for your most demanding control applications.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"8\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eIntegrated PLC and High-Performance CPU\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe XV303 eliminates the need for a separate PLC by embedding high-speed control logic directly into the HMI hardware. The ARM Cortex-A9 processor powers both the graphical interface and the background logic execution, ensuring zero-latency response times during high-speed switching operations. This integration reduces cabinet space requirements and simplifies your overall system architecture.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eMulti-Touch Capacitive Technology\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003eThe industrial-strength capacitive glass sensor supports multi-touch gestures, allowing operators to zoom into trend graphs or utilize dual-hand safety controls directly on the screen. This scratch-resistant surface withstands aggressive cleaning agents and provides superior visibility compared to traditional resistive screens, maintaining long-term optical clarity.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eExtensive Communication Interfaces\u003c\/h3\u003e\n\u003cp data-path-to-node=\"14\"\u003eEquipped with dual Ethernet ports, CANopen, and RS485 interfaces, the XV-303 acts as a versatile communication hub. It supports modern industrial protocols such as EtherCAT, Modbus TCP, and EtherNet\/IP, enabling it to command frequency drives, remote I\/O, and sensors across a distributed factory environment without requiring additional gateway modules.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"15\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable data-path-to-node=\"16\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,0,0\"\u003e\u003cb data-path-to-node=\"16,1,0,0\" data-index-in-node=\"0\"\u003eDisplay Size \/ Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,1,0\"\u003e10.1\" Widescreen \/ Capacitive Multi-touch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,0,0\"\u003e\u003cb data-path-to-node=\"16,2,0,0\" data-index-in-node=\"0\"\u003eResolution\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,1,0\"\u003e1024 x 600 Pixels (WSVGA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,0,0\"\u003e\u003cb data-path-to-node=\"16,3,0,0\" data-index-in-node=\"0\"\u003eProcessor\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,1,0\"\u003eARM Cortex-A9 800 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,0,0\"\u003e\u003cb data-path-to-node=\"16,4,0,0\" data-index-in-node=\"0\"\u003eMemory\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,1,0\"\u003e512 MB RAM \/ 128 MB NVRAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,0,0\"\u003e\u003cb data-path-to-node=\"16,5,0,0\" data-index-in-node=\"0\"\u003eOperating System\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,1,0\"\u003eWindows Embedded Compact 7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,0,0\"\u003e\u003cb data-path-to-node=\"16,6,0,0\" data-index-in-node=\"0\"\u003eSupply Voltage\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,1,0\"\u003e24 V DC (Tested \u0026amp; Working)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,0,0\"\u003e\u003cb data-path-to-node=\"16,7,0,0\" data-index-in-node=\"0\"\u003eCommunication Ports\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,1,0\"\u003e2x Ethernet, 1x RS485, 1x CANopen, 2x USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,8,0,0\"\u003e\u003cb data-path-to-node=\"16,8,0,0\" data-index-in-node=\"0\"\u003eProtection Rating\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,8,1,0\"\u003eIP65 (Front) \/ IP20 (Rear)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,9,0,0\"\u003e\u003cb data-path-to-node=\"16,9,0,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,9,1,0\"\u003e0 °C to 50 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,10,0,0\"\u003e\u003cb data-path-to-node=\"16,10,0,0\" data-index-in-node=\"0\"\u003eDimensions (W x H x D)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,10,1,0\"\u003e269 mm x 174 mm x 58 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,11,0,0\"\u003e\u003cb data-path-to-node=\"16,11,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,11,1,0\"\u003eApprox. 1.25 kg (Base Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-path-to-node=\"17\"\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3 data-path-to-node=\"18\"\u003ePower Supply and Connection\u003c\/h3\u003e\n\u003cp data-path-to-node=\"19\"\u003eAlways utilize the provided 24V DC plug for power termination. To ensure stable PLC operation and protect against electrical noise, connect the unit to a stabilized power source and ensure the grounding terminal is properly bonded to the central cabinet earth bar.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"20\"\u003eMounting and Environmental Protection\u003c\/h3\u003e\n\u003cp data-path-to-node=\"21\"\u003eInstall the XV303 using the included mounting brackets to achieve the rated IP65 front protection. Ensure the panel cutout matches the 255mm x 160mm dimensions precisely. Avoid installing the unit in direct sunlight or near high-heat components to prevent thermal throttling of the internal CPU.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"22\"\u003ePeripheral Integration\u003c\/h3\u003e\n\u003cp data-path-to-node=\"23\"\u003eWhen connecting to the Ethernet ports, utilize shielded CAT6 cables to maintain signal integrity in high-EMI environments. The integrated SD card slot allows for easy external data logging and program updates; ensure cards are industrial-grade to prevent data corruption during power loss events.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"24\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp data-path-to-node=\"25\"\u003eThe XV-303-10-C00-A00-1C excels in decentralized automation where space and performance are at a premium. Its fanless design reduces maintenance cycles, as there are no moving parts to fail or filters to clog with industrial dust. The glass front is not only easy to clean but also incredibly durable against the repetitive impact of heavy industrial gloves. By consolidating the HMI and PLC into a single device, you reduce the points of failure and streamline your software development within the CODESYS environment. This unit’s ability to act as both a Modbus master and a web server allows facility managers to monitor machine status remotely through standard mobile devices, bridging the gap between the shop floor and IT infrastructure.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"26\"\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp data-path-to-node=\"27\"\u003e\u003cb data-path-to-node=\"27\" data-index-in-node=\"0\"\u003eDelivery Time:\u003c\/b\u003e 3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp data-path-to-node=\"27\"\u003e\u003cb data-path-to-node=\"27\" data-index-in-node=\"51\"\u003eShipping Carriers:\u003c\/b\u003e Shipped globally via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003cp data-path-to-node=\"27\"\u003e\u003cb data-path-to-node=\"27\" data-index-in-node=\"111\"\u003ePackaging:\u003c\/b\u003e We ship all XV-303 units in \u003cb data-path-to-node=\"27\" data-index-in-node=\"150\"\u003eanti-static and impact-resistant packaging\u003c\/b\u003e. As this item is in mint condition and fully tested, it is double-boxed to ensure the screen and housing arrive without a single scratch.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"28\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp data-path-to-node=\"29\"\u003e\u003cb data-path-to-node=\"29\" data-index-in-node=\"0\"\u003eQ1: Does this unit include the CODESYS PLC license?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"29\"\u003eA1: Yes, the XV-303-10-C00-A00-1C comes with the PLC runtime pre-installed and licensed, allowing you to use it as a complete logic controller right out of the box.\u003c\/p\u003e\n\u003cp data-path-to-node=\"30\"\u003e\u003cb data-path-to-node=\"30\" data-index-in-node=\"0\"\u003eQ2: Can I operate this touch screen while wearing industrial gloves?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"30\"\u003eA2: The advanced capacitive sensor is tuned for industrial use. While it supports multi-touch gestures, it is also responsive to common industrial gloves, ensuring seamless operator interaction.\u003c\/p\u003e\n\u003cp data-path-to-node=\"31\"\u003e\u003cb data-path-to-node=\"31\" data-index-in-node=\"0\"\u003eQ3: What accessories are included with this specific \"Mint Condition\" item?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"31\"\u003eA3: This unit includes the necessary mounting brackets for panel installation and the essential 24V DC power connector plug, ensuring you have the hardware needed for immediate setup.\u003c\/p\u003e\n\u003cp data-path-to-node=\"32\"\u003e\u003cb data-path-to-node=\"32\" data-index-in-node=\"0\"\u003eQ4: Is the display readable in bright factory environments?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"32\"\u003eA4: Yes, the 10.1-inch display features high-contrast LED backlighting and a high-resolution glass surface that minimizes glare compared to plastic resistive screens, ensuring excellent legibility from wide viewing angles.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45953001914541,"sku":"XV-303-10-C00-A00-1C","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/XV-303-10-C00-A00-1C_1.jpg?v=1777282527"},{"product_id":"eaton-elc-pv28nndt-programmable-logic-controller-28-io-24vdc-transistor-output","title":"Eaton ELC-PV28NNDT Programmable Logic Controller 28-IO 24VDC Transistor Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton ELC-PV28NNDT stands as a high-performance cornerstone within the ELC2 generation, delivering advanced 32-bit processing power in a modular nano-PLC footprint. This controller addresses the rigorous demands of high-speed industrial machinery, where rapid execution of logic is paramount for maintaining system synchronization. By utilizing a 32-bit CPU, the ELC-PV28NNDT significantly reduces scan times compared to standard micro-controllers, allowing it to manage complex mathematical operations and high-speed pulse inputs with exceptional precision. With a dense configuration of 28 built-in I\/O points—consisting of 16 versatile digital inputs and 12 high-speed transistor outputs—this unit provides the perfect balance of scale and speed for localized control systems, assembly lines, and specialized OEM equipment.\u003c\/p\u003e\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eHigh-Speed 32-Bit Processing\u003c\/h3\u003e\n\u003cp\u003eThe ELC2 architecture utilizes a 32-bit RISC processor that executes instructions with remarkable efficiency. This hardware advantage enables the controller to handle sophisticated PID loops and high-frequency motion control tasks that typically require much larger and more expensive PLC systems.\u003c\/p\u003e\n\u003ch3\u003eVersatile Sinking\/Sourcing Inputs\u003c\/h3\u003e\n\u003cp\u003eThe 16 digital inputs support both Sink and Source configurations (24VDC), providing maximum flexibility when integrating various sensor types. This adaptability simplifies the bill of materials for engineers, as the ELC-PV28NNDT can interface with almost any NPN or PNP field device without additional signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eEfficient Transistor Output Array\u003c\/h3\u003e\n\u003cp\u003eThe 12 NPN transistor outputs provide high-speed switching capabilities with a 300mA capacity per point. These outputs excel in applications requiring pulse-width modulation (PWM) or rapid cycling of solenoid valves and small DC relays, where mechanical relay lifespan would be insufficient.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eELC2 Generation (High-Speed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (24VDC, Sink\/Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 (Transistor NPN\/Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 A per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Output Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCPU Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-Bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4 V DC – 28.8 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e46 mm x 90 mm x 60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003ePower Supply Integrity\u003c\/h3\u003e\n\u003cp\u003eThe ELC-PV28NNDT requires a stable 24VDC power source. Ensure that the power supply ripple remains within 5% to prevent internal logic resets. We recommend utilizing a dedicated industrial power supply to isolate the PLC from high-power inductive loads that may induce electrical noise.\u003c\/p\u003e\n\u003ch3\u003eWiring and Grounding\u003c\/h3\u003e\n\u003cp\u003eWhen wiring the 16 digital inputs, ensure signal cables are separated from high-voltage AC lines to minimize electromagnetic interference (EMI). Connect the ELC ground terminal to the main panel earth bar using the shortest possible path to ensure the internal 32-bit CPU remains shielded from transient surges.\u003c\/p\u003e\n\u003ch3\u003eHeat Dissipation and Clearance\u003c\/h3\u003e\n\u003cp\u003eAlthough the unit only consumes 6W, maintain a minimum clearance of 50mm above and below the PLC when mounted on the DIN rail. This space allows for natural airflow, ensuring that the transistor outputs can operate at their full 0.3A rating without thermal derating in enclosed control cabinets.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe ELC-PV28NNDT excels in precision-driven environments where space is at a premium but processing speed cannot be compromised. Its robust construction ensures long-term reliability in high-vibration applications such as conveyor sorting or automated testing rigs. The ELC2 series' compatibility with advanced communication protocols allows this PLC to serve as an intelligent node within a larger SCADA network. By integrating this controller, engineers secure a future-proof hardware platform that handles high-density I\/O tasks while maintaining the thermal efficiency required for tightly packed industrial control panels.\u003c\/p\u003e\n\u003ch2\u003eDelivery \u0026amp; Logistics\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3-5 days once payment is finalized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipped globally via DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe dispatch all units in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-static and impact-resistant packaging\u003c\/strong\u003e. Every PLC is shipped in its original factory-sealed box to guarantee that the 32-bit hardware remains in pristine condition from our facility to your site.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: What is the primary difference between the ELC-PV and the standard ELC-PB models?\u003c\/p\u003e\n\u003cp\u003eA1: The PV series is part of the ELC2 generation, featuring a significantly faster 32-bit CPU and increased memory capacity compared to the standard PB models, making it suitable for more complex logic and faster scan times.\u003c\/p\u003e\n\u003cp\u003eQ2: Can I use this controller to drive high-speed stepper motors?\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the transistor outputs on the ELC-PV28NNDT are capable of high-speed pulse output, making it an excellent choice for controlling stepper drives and servo systems in localized motion applications.\u003c\/p\u003e\n\u003cp\u003eQ3: Does this unit support analog expansion modules?\u003c\/p\u003e\n\u003cp\u003eA3: Absolutely. The ELC-PV28NNDT is fully expandable. You can connect ELC series analog I\/O, temperature measurement, and communication modules to the right side of the main unit to meet specific project needs.\u003c\/p\u003e\n\u003cp\u003eQ4: How do I configure the inputs for Sink vs. Source?\u003c\/p\u003e\n\u003cp\u003eA4: You determine the input logic by the wiring of the S\/S (Sink\/Source) terminal. Connecting the S\/S terminal to +24V configures the inputs as Sink; connecting it to 0V configures them as Source.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45953022329005,"sku":"ELC-PV28NNDT","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ELC-PV28NNDT_1.jpg?v=1777283739"}],"url":"https:\/\/www.maxwellplc.com\/collections\/eaton.oembed","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}