{"title":"Bently Nevada Sensor","description":"\u003cp\u003eAccurate data begins at the source. Our selection of \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"71\"\u003eBently Nevada sensors\u003c\/b\u003e includes seismic transducers, accelerometers, and pressure sensors engineered to withstand the harshest industrial environments. These sensors translate physical machine movement into actionable electrical signals, allowing your team to detect early signs of bearing wear or rotor instability. Built for longevity and precision, these units are essential for any robust predictive maintenance program.\u003c\/p\u003e","products":[{"product_id":"330180-90-cn-bently-nevada-proximity-probes-3300-xl","title":"330180-90-CN Bently Nevada Proximity Probes 3300 XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330180-90-CN is a critical component of the renowned 3300 XL 8 mm Proximity Transducer System, specifically engineered for high-precision vibration and position monitoring in demanding industrial environments. As a cornerstone of Turbomachinery Information (TSI) systems, this Proximitor sensor is designed to provide stable, reliable, and continuous monitoring for rotating machinery such as steam turbines, centrifugal compressors, and industrial generators.\u003c\/p\u003e\n\u003cp\u003eThis sensor represents the gold standard in non-contact displacement measurement, ensuring that critical assets operate within safe parameters. By converting the gap between the probe tip and the observed target into a precise analog signal, the 330180-90-CN provides plant operators with the real-time data necessary for predictive maintenance, condition-based monitoring, and protection against catastrophic mechanical failure. Even following its official discontinuation date of December 31, 2018, the 330180-90-CN remains a highly sought-after component due to its proven reliability, seamless integration into legacy control architectures, and robust construction capable of surviving extreme temperature fluctuations and harsh industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-90-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC 12–24V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.00 x 6.00 x 6.50 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSI \/ Industrial Control Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrand New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-90-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows the strict Bently Nevada coding convention for the 3300 XL series.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180\u003c\/strong\u003e: Identifies the Proximitor Sensor assembly specifically designed for the 8 mm transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e90\u003c\/strong\u003e: Indicates the specific regulatory\/calibration setting for the sensor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Denotes the agency approval\/certification specific to the Chinese market (or regional compliance standards), ensuring the device meets the necessary electromagnetic and safety requirements for local industrial deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe 330180-90-CN is engineered for environments where machine reliability is paramount. Its primary applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurbine Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous tracking of rotor vibration and position to detect misalignment or bearing wear in steam and gas turbines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding essential data to prevent surge conditions and monitor shaft behavior under high-pressure loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator Shafts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring thermal expansion and shaft sag in massive power generation equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePredictive Maintenance Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeeding raw vibration data into automated diagnostic platforms to calculate Remaining Useful Life (RUL) and schedule maintenance before unplanned downtime occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Interlocking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrating with emergency shutdown systems (ESD) to trigger automatic machine halts if vibration levels exceed established thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330180-90-CN is designed for high-level interoperability with modern and legacy industrial systems. While primarily functioning as a transducer for Bently Nevada 3300 or 3500 series monitoring racks, its 4–20 mA output makes it universally compatible with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePLC\/DCS Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEasily mapped into programmable logic controllers or distributed control systems from vendors such as Siemens, Honeywell, Emerson, and ABB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Acquisition Systems (DAQ):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be interfaced with high-speed analog input cards for advanced signal analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Monitoring Networks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with standard Ethernet-based gateways or router configurations when managed through a signal conditioner.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the sensor is housed in a thermally stable, vibration-damped bracket to prevent mechanical interference with the readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended radial clearance from the target to avoid sensor saturation or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-quality, shielded extension cables to minimize electromagnetic interference (EMI) in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the system ground is consistent with Bently Nevada installation standards to prevent ground loops that could skew the 4–20 mA signal output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways perform a bench-top gap verification test before permanent installation to ensure the probe and Proximitor are matched to the specific target material properties.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnmatched Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOffers highly accurate, non-contact measurement of shaft displacement, essential for identifying sub-synchronous or synchronous vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe stainless steel housing provides excellent resistance to corrosion, high humidity, and chemical exposure typical in power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a near-instantaneous output, providing the high-speed data required for transient analysis during machine startups and coast-downs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates reliably on 12–24V DC, allowing for stable performance even in plants with unstable auxiliary power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith decades of field-tested performance, this sensor is a trusted choice for mission-critical industrial applications globally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWe maintain an in-stock inventory of the 330180-90-CN to ensure immediate dispatch. All units are brand new, original Bently Nevada stock. For bulk procurement or project-specific requirements, please contact our technical sales team.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn Stock (Ready for immediate shipment).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 Unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure, industry-standard packaging to prevent damage during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of signal output does the 330180-90-CN provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The sensor outputs a standard 4–20 mA analog signal, allowing for straightforward integration into almost any industrial PLC, DCS, or remote telemetry system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this sensor operate in extreme temperature ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the 330180-90-CN is rated for reliable operation in temperatures ranging from -40°C to +85°C, making it suitable for both outdoor and hot-running machine installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the stainless steel construction suitable for harsh industrial settings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Absolutely. The rugged stainless steel housing is specifically designed to resist environmental stresses, including moisture, heat, and vibration found in industrial manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the primary detection range of this sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The 330180-90-CN offers a highly flexible detection range of up to 10 meters, allowing for broad monitoring capabilities across large mechanical setups and site layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can it integrate with existing PLC or DCS monitoring systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Yes, because it utilizes a standard 4–20 mA loop, it is natively compatible with the majority of industrial controllers, enabling seamless integration into your existing safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What is the weight and physical dimension of the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA6: The unit is compact and lightweight, weighing approximately 0.22 kg with physical dimensions of 8 x 6 x 6.5 cm, allowing for easy mounting in space-constrained cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: Why was this specific model discontinued in 2018?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA7: The discontinuation marks the natural lifecycle evolution of the Bently Nevada 3300 XL series. Many users still source these units for legacy system maintenance and consistent replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Does this sensor require specialized installation tools?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA8: While standard electrical installation tools are sufficient, we recommend using a calibrated gap-setting tool to ensure the precision of the transducer's measurement range upon installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378087092397,"sku":"330180-90-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-90-cn-proximitor-sensor-w254xy3equw.jpg?v=1764225457"},{"product_id":"330180-92-05-bently-nevada-proximitor-sensor-3300-xl","title":"330180-92-05 Bently Nevada Proximitor Sensor 3300 XL","description":"\u003cp\u003eConfigured for signal conditioning in proximity transducer systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-92-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330180-92-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor) provides direct physical and electrical execution of probe-to-monitor signal translation within 3300 XL platform architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e330180\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e330180-92-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 8 mm Proximity Transducer System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-92-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 x 6.0 x 6.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult 3300 XL manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 meters (Total)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 330180-92-05 Proximitor Sensor processes high-frequency signals from eddy-current probes to measure rotor displacement. Calibration of eddy-current probe scaling is required at the installation site to align the output voltage with the specific target material characteristics. Technicians must perform gap voltage validation to ensure the -10 VDC target midpoint is achieved for linear transducer response. The sensor design incorporates filtering for cross-talk suppression, ensuring that multi-probe installations do not experience signal interference during operation in complex rotor dynamics applications.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330180-92-05 Proximitor Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation covering integration, wiring, and safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware for standard DIN-rail installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the sensor to the DIN rail; ensure the housing is grounded to the cabinet instrument bus to maintain signal common.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate coaxial cabling from the probe and the extension cable to the sensor input terminals, maintaining impedance continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize a star-ground configuration for all instrumentation signal shields to eliminate ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirm that the output voltage at the Proximitor \"OUT\" terminal matches the theoretical value based on the measured physical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the sensor compatible with all 3300 XL 8 mm probes?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it is designed for use within the 3300 XL 8 mm Proximity Transducer System family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 9-meter range?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe total system length (probe + extension cable) is calibrated to 9 meters to maintain correct signal impedance and frequency response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this be mounted in an outdoor environment?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor must be protected within a NEMA-rated or IP-rated enclosure; it is not designed for direct exposure to elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the sensor field-configurable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the internal circuitry is factory-calibrated for specific transducer system lengths; do not modify or alter the cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a \"Not OK\" status?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify input power, check for cable continuity, and perform a gap voltage check to ensure the probe tip is within the linear sensing range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the frequency response?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor is capable of high-frequency operation to track rapid shaft movements and vibration transients accurately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs hot-swapping supported?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHot-swapping is dependent on the monitoring system configuration; consult the 3500 system or rack manual before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting options are available?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit supports standard DIN-rail mounting for integration into control cabinet backplanes or racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378087157933,"sku":"330180-92-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-92-05-proximitor-sensor-2qdeihaxoud.jpg?v=1764225458"},{"product_id":"330180-91-00-bently-nevada-proximitor-sensor-3300-xl-series","title":"330180-91-00 Bently Nevada Proximitor Sensor 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-91-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-91-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor, operates as a dedicated hardware component for eddy-current signal conditioning within TSI (Turbomachinery Information) monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Model Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-91-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 x 3.5 x 7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz to 2 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Conditioning and Eddy-Current Mechanics\u003c\/h3\u003e\n\u003cp\u003eThe 330180-91-00 utilizes high-frequency radio waves to excite the target material. Precise operation requires maintaining a nominal gap voltage, typically centered at -10 VDC within the linear range of the probe-extender-proximitor system. The sensor performs signal linearization to convert raw inductance changes into a proportional voltage output (typically 200 mV\/mil). Effective rotor dynamics analysis relies on this proximitor to suppress cross-talk when multiple probes are installed in close proximity, ensuring that phase and amplitude measurements remain accurate under high-speed rotational load.\u003c\/p\u003e\n\u003ch3\u003eOrder Fulfillment\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe shipment includes the Proximitor unit only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequired probe and extension cables must be ordered separately based on system length requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocumentation includes standard Bently Nevada technical manual references.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnit arrives in factory-sealed industrial packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting must ensure the proximitor is electrically isolated from the panel chassis if grounded loops are a risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProximitor cable length must be accounted for in total system length (TSL) calculations to maintain calibrated sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the probe tip is properly centered within the mounting bracket to avoid interference from surrounding metal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify shield continuity on extension cables to minimize EMI\/RFI noise in the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 330180-91-00 compatible with older 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility depends on the specific TSL (Total System Length). Mixing legacy 3300 components with 3300 XL proximitors requires verification of calibration curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the effect of incorrect gap voltage on data?\u003c\/p\u003e\n\u003cp\u003eA: Operating outside the linear range (-10 VDC nominal) will cause waveform clipping and signal distortion, leading to inaccurate vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this unit be hot-swapped during operation?\u003c\/p\u003e\n\u003cp\u003eA: While the electronic circuits are robust, hot-swapping can trigger transients in the monitoring system. Power-down is recommended to prevent false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the IP67 rating maintained during field wiring?\u003c\/p\u003e\n\u003cp\u003eA: The IP67 rating applies to the module housing. Field wiring connections must use appropriate conduit seals and moisture-resistant terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the unit require periodic recalibration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, annual calibration verification against a known target is standard procedure for TSI systems to ensure linearity within 0.1%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the impact of cable length on output impedance?\u003c\/p\u003e\n\u003cp\u003eA: The 3300 XL system is calibrated for specific cable lengths (5m or 9m). Deviating from these lengths changes the system gain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the proximitor provide diagnostic status?\u003c\/p\u003e\n\u003cp\u003eA: The unit outputs a \"Gap\" voltage which serves as a diagnostic indicator. A voltage near -2 VDC or -18 VDC indicates an open or short circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does this sensor handle power supply noise?\u003c\/p\u003e\n\u003cp\u003eA: The internal filtering design rejects ripple on the 12-24 VDC supply, though a regulated, low-noise power source is required for optimal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378090172589,"sku":"330180-91-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-91-00-5-8-mm-proximitor-sensor-rcdw0doug3q.jpg?v=1764225500"},{"product_id":"330180-90-05-bently-nevada-proximitor-sensor-3300-xl-series","title":"330180-90-05 Bently Nevada Proximitor Sensor 3300 XL Series","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330180-90-05 is a signal conditioning unit engineered for the 3300 XL Proximity Transducer System. This device is the core interface between the physical probe and the monitoring system, responsible for converting the high-frequency radio frequency (RF) signal generated by the proximity probe into a proportional voltage signal. This voltage output is essential for the accurate determination of rotor-to-stator gap, vibration, and shaft position in critical rotating machinery. Designed for stability in challenging electromagnetic and thermal environments, the 330180-90-05 ensures signal linearity and repeatability required for Total System Integrity (TSI).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-90-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.8 x 6 x 6.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mA max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTechnology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRF Eddy-Current Signal Conditioning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67 (Housing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiscontinued Date\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDec 31, 2018\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe 330180-90-05 part number structure reflects specific design parameters within the 3300 XL series:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330180: Denotes the 3300 XL 5 mm and 8 mm Proximitor Sensor family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-90: Indicates the agency approval and configuration options, specifically calibrated for standard system impedance and length requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-05: Represents the specific mounting and termination configuration (DIN rail compatible).\u003c\/p\u003e\n\u003cp\u003eEngineers should note that the 3300 XL Proximitor sensor is calibrated as a complete system (Probe, Extension Cable, and Proximitor Sensor). Substituting mismatched components will result in linear error and loss of calibration accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbomachinery Protection: Real-time monitoring of turbine shaft vibration to prevent catastrophic bearing failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal Compressor Analysis: Detecting rotor eccentricity, axial position, and transient vibration during startup or shutdown cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox Diagnostics: Monitoring mesh vibration in high-speed, heavy-load gear sets to predict wear patterns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Balancing: Providing high-speed feedback for field balancing applications in power generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330180-90-05 is fully compatible with the Bently Nevada 3300 XL 5 mm and 8 mm probe systems. It is designed to interface with 3500 series vibration monitoring racks. It is not interchangeable with 3300 series (non-XL) sensors without recalibrating the entire transducer loop. Ensure the system firmware supports 3300 XL modules when upgrading legacy infrastructure.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the Proximitor sensor in a protected, dry cabinet using the provided DIN-rail mounting bracket. Avoid locations subject to high-frequency mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: The 3300 XL system requires proper grounding to maintain signal-to-noise ratios. Ensure the Proximitor housing is connected to a high-quality instrument ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use only Bently Nevada-certified coaxial extension cables with TwistLock or standard connectors. Ensure all cable connections are tightened manually until firm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Loop: Check the -10 VDC to -24 VDC supply voltage range. Verify the probe tip gap (nominal -10 VDC output) upon installation before machine rotation begins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLinearized Output: Provides a highly linear 200 mV\/mil output across the entire measurement range, ensuring accurate data for PLC\/DCS integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectromagnetic Immunity: Rugged design minimizes interference from Variable Frequency Drives (VFDs) and other high-EMI sources common in large industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-Term Stability: Component aging is minimized, reducing the drift typically associated with temperature cycles in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit Capability: The 3300 XL series remains the global benchmark for machinery protection, offering extensive spares and documentation support for existing assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330180-90-05 Proximitor Sensor (New\/Original)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible 330101\/330102 5mm\/8mm probes (Ordered separately)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible 330130 extension cables (Ordered separately)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail mounting hardware included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a cable mismatch?\u003c\/p\u003e\n\u003cp\u003eUsing an extension cable not calibrated for the 330180-90-05 will introduce impedance errors, causing measurement inaccuracies that could lead to false alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify the sensor is functional?\u003c\/p\u003e\n\u003cp\u003eMeasure the supply voltage at the Proximitor terminal and verify the output voltage while checking the probe-to-target gap with a feeler gauge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 330180-90-05 work with legacy 3300 systems?\u003c\/p\u003e\n\u003cp\u003eIt is compatible with 3300 series monitoring racks, provided the transducer system components (probe, cable, sensor) are all 3300 XL series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip is damaged?\u003c\/p\u003e\n\u003cp\u003eA damaged tip alters the RF field, leading to signal instability. If the epoxy coating is scratched, the sensor should be replaced immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit be mounted outdoors?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor itself is designed for NEMA-rated cabinet mounting. It should not be exposed directly to rain or salt spray; use a weatherproof enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is this model marked as discontinued?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL series is a mature platform. While the 330180-90-05 is a legacy part, the 3300 XL technology remains supported for critical maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal output at 0 mm gap?\u003c\/p\u003e\n\u003cp\u003eThe system is typically calibrated to provide a near-zero voltage output when the probe is in mechanical contact with the target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the sensor measure non-metallic objects?\u003c\/p\u003e\n\u003cp\u003eNo. It relies on eddy-current technology, which requires a conductive metallic target to create the necessary RF field perturbations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent signal cross-talk?\u003c\/p\u003e\n\u003cp\u003eEnsure that probes are separated by at least 1.5 inches for radial measurements and that cable shields are grounded at the system end only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the lifespan of the sensor?\u003c\/p\u003e\n\u003cp\u003eWith proper installation and protection from mechanical damage, these sensors often exceed 10-15 years of operational life in controlled environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378090401965,"sku":"330180-90-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-90-05-3300xl-5-8-mm-proximitor-sensor-fiezfwww3ne.jpg?v=1764225504"},{"product_id":"330180-51-00-bently-nevada-proximitor-sensor-3300-xl-series","title":"330180-51-00 Bently Nevada Proximitor Sensor 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-51-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor, serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe system component utilized to execute shaft vibration and position monitoring across industrial rotating equipment platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-51-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epart number defines the specific frequency response and physical mounting configuration for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransducer platform. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffixes indicate the calibrated output signal range and agency approval standard, ensuring compatibility with standard proximity probe setups.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-51-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 x 3.6 x 7.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProportional to target gap\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThis module utilizes eddy-current principle-based sensing to provide high-resolution displacement data. Successful signal conditioning requires precise gap voltage validation, typically aimed at a -10 VDC nominal target during the installation phase. To ensure data integrity, the system implements cross-talk suppression by utilizing unique frequency-encoded carrier signals, preventing interference when multiple probes are clustered around a single machine shaft. The rotor dynamics monitoring capability depends on the linear scaling of the transducer, which converts the gap distance into precise voltage changes processed by the supervisory system.\u003c\/p\u003e\n\u003ch3\u003e## Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330180-51-00 Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation manual and technical compliance documents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting plate hardware for standard panel installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective shipping container with static-dissipative materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure a low-impedance connection to the instrument common ground to prevent potential differences across the signal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Keep sensor signal leads physically separated from high-current AC power lines to avoid EMI induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransducer Gap: Set the probe tip gap according to the machine-specific shaft diameter and transducer linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Security: Ensure the housing is firmly attached to the mounting surface to eliminate mechanical vibration effects on the sensor electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this sensor compatible with older 3300 series transducers?\u003c\/p\u003e\n\u003cp\u003eYes, it provides backward compatibility with legacy proximity probe components while maintaining 3300 XL system performance levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the required operating voltage for this module?\u003c\/p\u003e\n\u003cp\u003eThe sensor operates on a nominal 12 VDC power supply; ensure the source is regulated to prevent signal drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the sensor handle transducer cable disconnects?\u003c\/p\u003e\n\u003cp\u003eIf the cable is disconnected or damaged, the module will output a fault-level signal to indicate a transducer error to the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I mount this sensor outdoors?\u003c\/p\u003e\n\u003cp\u003eWhile the electronics are robust, it is recommended to install the unit within an IP-rated enclosure to prevent moisture and chemical exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this sensor support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eField replacement is possible; however, ensure the loop is properly isolated to prevent transient voltage damage to connected monitoring racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response time for signal changes?\u003c\/p\u003e\n\u003cp\u003eThe sensor provides real-time signal tracking with negligible latency, suitable for high-speed rotating equipment diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the -40 deg C minimum temperature affect the internal oscillator?\u003c\/p\u003e\n\u003cp\u003eNo, the internal components are rated for continuous operation within the specified range without calibration degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify signal accuracy?\u003c\/p\u003e\n\u003cp\u003eUse a digital voltmeter to check the gap voltage at the field test points and compare the reading against the required linear range chart.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378091024557,"sku":"330180-51-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-51-00-3300-xl-proximitor-sensor-proximity-switch-24ni1ysosth.jpg?v=1764225514"},{"product_id":"330180-91-05-bently-nevada-proximitor-sensor-3300-xl-series","title":"330180-91-05 Bently Nevada Proximitor Sensor 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330180-91-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-91-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor, operates as a dedicated hardware component for converting proximity probe transducer signals into voltage or current outputs within 3300 XL 8 mm Proximity Transducer Systems.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-91-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel identifier indicates a specific factory configuration for electrical output scaling and probe compatibility. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-91\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffixes dictate the frequency response tuning and agency approval compatibility for the 3300 XL 8 mm transducer series.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-91-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.8 x 3.5 x 7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 kHz to 1 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.02% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA (Loop configured)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThis Proximitor sensor utilizes an RF oscillator to drive the proximity probe, generating a magnetic field that detects target displacement. Accurate scaling is maintained by validating the gap voltage, with a nominal target of -10 VDC at the center of the linear range. To ensure measurement precision, the sensor architecture employs active cross-talk suppression, preventing interference when multiple probes are installed in close proximity on the same machine casing. Proper integration requires verifying the system-wide rotor dynamics, ensuring the probe output accurately reflects shaft motion without distortion from high-frequency electromagnetic environmental noise.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330180-91-05 Proximitor Sensor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware (DIN-rail or panel mount compatible).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated terminal block for field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard technical documentation in digital format.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: The sensor chassis must be connected to a clean instrument ground to maintain the integrity of the 4-20 mA current loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Maintain a minimum clearance of 50 mm from high-voltage AC cables to reduce inductive noise pick-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Gap: Ensure the initial gap voltage is set to the specified -10 VDC target before applying operational loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTermination: Verify that the signal loop resistance does not exceed the maximum limits specified for the interface device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330180-91-05 compatible with 3300 XL probes?\u003c\/p\u003e\n\u003cp\u003eYes, it is designed for use exclusively with the 3300 XL 8 mm transducer system components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this sensor support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe Proximitor is a field-terminating device; while the loop can be broken, hot-swapping requires careful isolation to prevent ground faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan it handle signals above 1 MHz?\u003c\/p\u003e\n\u003cp\u003eNo, the frequency response is physically limited to a 1 kHz to 1 MHz range for standard displacement monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 12 VDC supply polarity sensitive?\u003c\/p\u003e\n\u003cp\u003eYes, observe proper polarity when connecting the 12 VDC power supply to prevent damage to internal oscillator circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the 4-20 mA output configured?\u003c\/p\u003e\n\u003cp\u003eThe output is linear with respect to the gap distance; scaling is set via the factory internal adjustments defined by the suffix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I mount this in high-interference zones?\u003c\/p\u003e\n\u003cp\u003eYes, the housing is designed to minimize EMI, but shielded cabling is necessary for all signal leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe cable is disconnected?\u003c\/p\u003e\n\u003cp\u003eThe sensor will output a voltage fault level, typically exceeding the normal operating range, signaling a transducer error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the sensor housing impact resistant?\u003c\/p\u003e\n\u003cp\u003eThe stainless steel housing provides mechanical protection against vibration and minor impacts in panel-mount configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378091614381,"sku":"330180-91-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-91-05-proximitor-sensor-0bvonuk0bnc.jpg?v=1764225520"},{"product_id":"330400-02-05-bently-nevada-velomitor-velocity-sensor","title":"330400-02-05 Bently Nevada Velomitor Velocity Sensor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330400-02-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVelocity Sensor, operates as a dedicated hardware component for casing vibration signal measurement within Bently Nevada 3500 Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Configuration Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330400: Velomitor Piezoelectric Velocity Sensor Base Model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-02: M8 x 1.25 integral mounting stud option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-05: Multiple hazardous area agency approvals option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330400-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 x 12.0 x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55 to 121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal loop power bias\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/-5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 Hz to 5000 Hz +\/-3.0 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Pin MIL-C-5015 hermetic top connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Sealing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e316L Stainless Steel, hermetically sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eVibration Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis piezoelectric sensor features internal solid-state integration that converts absolute case acceleration into a proportional velocity voltage output. The onboard electronics provide high-frequency filtering to eliminate acoustic anomalies, enforcing cross-talk suppression and electrical noise isolation across long wire runs. While proximity loops require precise eddy-current probe scaling and stable gap voltage validation (-10 VDC targets), this velocity tracking transducer functions as a self-contained seismic module optimized for tracking rotor dynamics and high-speed structural casings.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330400-02-05 Velomitor Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 M8 x 1.25 Mounting Stud (Installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Lock Washer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mechanical Mount Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurface Plane Planarity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMachine the mounting surface flat to a tolerance of 0.03 mm to ensure true mechanical coupling with the sensor base plane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Rating Specification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTighten the 316L stainless housing onto the installation hub using a calibrated tool up to exactly 4.5 N-m (40 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Run Isolations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEncase the raw interconnecting cable inside liquid-tight flexible conduit to shield the system from inductive interference loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Weatherproof Seal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCoat the MIL-C-5015 connector contacts with moisture-inhibiting silicone grease prior to engaging the outer mating ring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensor Infrastructure FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this velocity transducer support hot-swap replacement routines?\u003c\/p\u003e\n\u003cp\u003eYes. The sensor can be disconnected from its field cable assembly while the central monitor chassis is powered without disrupting other channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom points to a failure in the internal sensor bias loop?\u003c\/p\u003e\n\u003cp\u003eA monitor-reported channel fault or a loop bias voltage reading shifting outside the standard 10 to 14 VDC window confirms component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does this casing sensor handle eddy-current probe scaling configurations?\u003c\/p\u003e\n\u003cp\u003eThis hardware does not use eddy-current scaling metrics, as it captures absolute casing velocity rather than relative oil-film shaft displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of exceeding the stated 4.5 N-m installation torque limit?\u003c\/p\u003e\n\u003cp\u003eOver-torqueing stretches the internal base crystal module, causing structural calibration drift or permanent failure of the sensing element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this velocity module be mounted in any directional plane?\u003c\/p\u003e\n\u003cp\u003eYes. The internal omnidirectional orientation mechanics allow the assembly to be positioned vertically, horizontally, or at any intermediate slant angle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the hermetic housing require external safety isolation barriers?\u003c\/p\u003e\n\u003cp\u003eYes. When running through hazardous environments, an external zener barrier or galvanic isolator must regulate the voltage loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does this module achieve cross-talk suppression during close-proximity installations?\u003c\/p\u003e\n\u003cp\u003eThe completely shielded internal capsule prevents radio frequency and adjacent electromagnetic fields from altering the low-impedance voltage output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat defines the behavior of the system if the outer casing contact loses ground?\u003c\/p\u003e\n\u003cp\u003eAn ungrounded housing builds up static floating potential, introducing spurious noise spikes that mimic mechanical machine defects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518808121517,"sku":"330400-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330400-02-05-velomitor-sensor-awmmuzojjic.jpg?v=1766979380"},{"product_id":"84661-33-bently-nevada-330500-series-velomitor-interconnect-cable","title":"84661-33 Bently Nevada 330500 Series Velomitor Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-2334 citation-end-2334\"\u003eThe Bently Nevada 84661-33 is a high-performance shielded interconnect cable specifically engineered for the Velomitor piezoelectric velocity sensor family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis critical cabling solution is designed to transmit low-impedance vibration signals from the sensor head to monitoring instrumentation or junction boxes without signal degradation. As a vital part of a Turbine Supervisory Instrumentation (TSI) suite, the 84661-33 ensures the integrity of absolute casing vibration data. Its construction focuses on noise rejection and mechanical resilience, making it a standard choice for industrial environments where electromagnetic interference (EMI) and physical stress are prevalent.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003ePhysical Composition and Engineering Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 84661-33 cable is built to exceed the requirements of standard industrial signal lines, featuring specialized materials for extreme reliability:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-2333\"\u003e\u003c\/span\u003e\u003cstrong\u003eCable Length:\u003c\/strong\u003e\u003cspan class=\"citation-2333 citation-end-2333\"\u003e\u003cspan\u003e \u003c\/span\u003e33 feet (approximately 10 meters)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-strand high-conductivity tinned copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-grade Fluorinated Ethylene Propylene (FEP) \/ Teflon for superior dielectric strength\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBraided tinned copper shield providing nearly 90% coverage for RFI\/EMI protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeavy-duty, chemical-resistant FEP, rated for immersion in industrial oils and solvents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for continuous operation from -40°C to +125°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for 2-pin MIL-C-5015 style moisture-resistant connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLow capacitance and low resistance (under 0.01 ohms\/meter) to prevent signal phase shifts over the 33ft span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMachinery Deployment and Utility Context\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is primarily utilized to link Velomitor 330500 or 330525 sensors to 3500 series machinery protection racks or Trendmaster Pro systems. It is commonly found on rotating assets that require casing-mounted vibration sensors, such as gas turbines, large centrifugal pumps, cooling tower fans, and industrial gearboxes. In the power generation and oil and gas sectors, the 84661-33 is a trusted component for identifying structural resonances, bearing housing instability, and aerodynamic piping vibration. Its rugged Teflon-based construction allows it to be routed through areas with high heat and chemical exposure without losing signal fidelity, ensuring that predictive maintenance teams receive accurate, deterministic vibration data for 24\/7 machinery protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518808580269,"sku":"84661-33","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-84661-33-velomitor-interconnect-cable-0ccxwwilo0b.jpg?v=1769752010"},{"product_id":"84661-17-bently-nevada-extension-cable-proximity-probes","title":"84661-17 Bently Nevada Extension Cable Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 84661-17\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e84661\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVelomitor Interconnect Cable, operates as a dedicated hardware component for casing vibration signal transmission within Bently Nevada 3500 Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003ePhysical Parameter Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e84661-17\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 x 20.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component (0 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17 feet (5.2 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Pin MIL-C-5015 to Terminal Lugs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluoropolymer Jacket\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohms nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis interconnect hardware interfaces directly with piezoelectric velocity sensors to capture real-time case acceleration and velocity profiles. The cable construction features balanced capacitance ratings engineered for cross-talk suppression and noise rejection across high-frequency pathways. By maintaining strict electrical impedance parameters, the link prevents signal degradation, enabling the monitoring monitors to execute precise eddy-current probe scaling and absolute vibration calculations for rotor dynamics assessment.\u003c\/p\u003e\n\u003ch3\u003eStandard Shipping Kit\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 84661-17 Interconnect Cable Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Electrical Continuity Test Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Deployment Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius Limits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum structural bend radius of 75 mm during installation to prevent internal conductor separation or shielding tears.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the fluoropolymer jacket through rigid or flexible metal conduit to isolate the link from direct mechanical impacts and abrasive contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTerminate the outer drain wire strictly at the monitor rack shield terminal; leave the sensor end isolated to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Tightening\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngage the MIL-C-5015 threaded coupling ring fully onto the sensor base connection, ensuring the internal seal is compressed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Infrastructure FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this passive interconnect assembly support hot-swap replacement procedures?\u003c\/p\u003e\n\u003cp\u003eYes. The interconnect cable can be disconnected and swapped while the main monitor rack is energized without causing channel faults or system damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does this cable assist in cross-talk suppression for close parallel runs?\u003c\/p\u003e\n\u003cp\u003eThe internal twisted-pair architecture combined with an isolated high-coverage shield minimizes inductive and capacitive coupling between adjacent transducer loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of cable length variations on eddy-current probe scaling configurations?\u003c\/p\u003e\n\u003cp\u003eThis velocity interconnect cable does not affect proximity probe calibration metrics, as it is engineered exclusively for self-generating velocity sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does moisture ingress at the connector affect gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eMoisture accumulation introduces parallel resistance paths, corrupting signal validation thresholds and shifting true output parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable assembly be deployed inside high-temperature turbine environments?\u003c\/p\u003e\n\u003cp\u003eThe fluoropolymer jacket handles continuous exposure up to 121 deg C, meeting structural specifications for standard industrial casings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal termination style is present on the monitor rack interface end?\u003c\/p\u003e\n\u003cp\u003eThe monitor termination features insulated straight lug connectors matched for standard screw terminal blocks on proximity monitor modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include an internal safety isolation barrier circuit?\u003c\/p\u003e\n\u003cp\u003eNo. This is a passive link component; intrinsic safety protection requires the insertion of external galvano-isolated or zener barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the shield conductor is grounded at both termination ends?\u003c\/p\u003e\n\u003cp\u003eDual-ended grounding induces circulating ground loop currents, introducing low-frequency noise that corrupts casing vibration tracking data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518808744109,"sku":"84661-17","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-84661-17-velomitor-interconnect-cable-5wywk3y03t0.jpg?v=1766979402"},{"product_id":"350800-01-180-bently-nevada-hazardous-gas-sensor","title":"350800-01-180 Bently Nevada Hazardous Gas Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 350800-01-180 is a high-fidelity gas detection module engineered for the 3500 Machinery Protection System. While Bently Nevada is widely recognized for vibration monitoring, this specialized sensor expands the system's utility into environmental safety and leak detection. It is designed to provide continuous, real-time monitoring of hazardous combustible or toxic gas concentrations in the immediate vicinity of rotating machinery. By integrating gas detection directly into the 3500 rack architecture, facilities can consolidate their mechanical protection and environmental safety protocols into a single, deterministic monitoring platform, ensuring that gas leaks—which often accompany mechanical seal failures—are detected instantly.\u003c\/p\u003e\n\u003ch3\u003eTechnical Architecture and Hardware Metrics\u003c\/h3\u003e\n\u003cp\u003eThe 350800-01-180 is built to sustain performance in the turbulent and thermally volatile environments found near industrial turbines and compressors.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Bently Nevada 3500\/94 series gas monitor modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDetection Principle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-stability catalytic bead or electrochemical sensing (configuration dependent).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for 0-180 ppm (or LEL equivalent based on target gas).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Endurance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade operation from -40°C to +120°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a linear analog signal converted for 3500 rack digital processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Suitability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCorrosion-resistant materials designed for mounting in Class I, Division 1 or Zone 1 hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRapid\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$T_{90}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eresponse rate for immediate alarm triggering during leak events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in self-diagnostics to identify sensor drift or element poisoning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Deployment and Safety Utility\u003c\/h3\u003e\n\u003cp\u003eThis sensor is a critical safety component for high-risk applications in the oil and gas, petrochemical, and power generation sectors. It is primarily deployed in gas turbine enclosures, compressor sheds, and pump galleries where the presence of volatile hydrocarbons or hydrogen represents a significant explosion risk. The 350800-01-180 is frequently utilized to monitor the integrity of primary and secondary seals; a rising gas concentration often serves as a \"first-out\" indicator of a seal breach before mechanical vibration levels significantly change. By linking the gas sensor data to the 3500 system’s relay logic, operators can automate emergency ventilation or initiate safe machine shutdowns, providing an essential layer of protection for both personnel and multi-million dollar capital assets.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518808907949,"sku":"350800-01-180","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-350800-01-180-hazardous-gas-sensor-wz0i2h3304q.jpg?v=1769751900"},{"product_id":"330780-90-00-bently-nevada-proximitor-sensor-3300-xl-series","title":"330780-90-00 Bently Nevada Proximitor Sensor 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330780-90-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330780-90-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor, operates as a dedicated hardware component for high-fidelity signal conditioning and displacement measurement within 3300 XL transducer systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330780-90-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: 3300 XL 11 mm Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop Length: 9.0 meters (factory calibrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Non-contacting displacement signal conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330780-90-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 cm x 10 cm x 8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 V\/mm (100 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI Mechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Proximitor sensor is calibrated to provide consistent eddy-current probe scaling for 11 mm transducer systems. It performs gap voltage validation against -10 VDC targets during system commissioning to ensure linear operation. The module is engineered to provide cross-talk suppression in high-density rack configurations, ensuring that excitation signals from adjacent channels do not influence displacement measurements. Rotor dynamics are monitored through a 4.0 mm linear range, with signal integrity maintained through high-frequency radio frequency (RF) oscillation and demodulation circuitry specifically matched to the 9.0 meter system loop length.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330780-90-00 Proximitor sensor unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation guide and compliance documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated mounting base hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Secure the module to a 35 mm DIN-rail or utilize the 4-hole bulkhead footprint; ensure the chassis is electrically isolated from the machine frame to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Utilize the SpringLoc terminal strips for field connections; ensure that coaxial cabling from the probe is properly torqued to the gold-plated connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the Proximitor common terminal to the instrument signal ground in accordance with Bently Nevada installation standards to maintain EMI\/RFI shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop Verification: Perform a static gap check to verify the probe output voltage is within the specified linear range before initiating turbine or generator startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure all signal cabling is routed through rigid conduit or grounded cable trays to protect the low-level displacement signal from electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this sensor compatible with 8 mm probe systems?\u003c\/p\u003e\n\u003cp\u003eA: No, the 330780-90-00 is specifically calibrated for 11 mm transducer systems; mixing probe and sensor types will lead to significant measurement errors and scale factor mismatch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten the 9-meter cable?\u003c\/p\u003e\n\u003cp\u003eA: No, the system is calibrated for a total loop length of 9.0 meters. Altering the cable length will change the electrical resonance and invalidate the factory scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I perform a gap voltage check?\u003c\/p\u003e\n\u003cp\u003eA: Use a high-impedance digital voltmeter to measure the output voltage at the Proximitor terminal block; the voltage should correspond to the physical distance between the probe tip and target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the sensor require a specific power supply polarity?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it requires a negative supply voltage (-17.5 VDC to -26 VDC) typical of Bently Nevada monitoring racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the impact of supply voltage fluctuations?\u003c\/p\u003e\n\u003cp\u003eA: The output signal is designed to be highly stable, with less than 2 mV of change per volt of input variation, ensuring minimal impact from power supply ripple.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the Proximitor waterproof?\u003c\/p\u003e\n\u003cp\u003eA: The housing is designed for installation within a protected control cabinet environment; it is not rated for direct exposure to process fluids or harsh outdoor moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify if the RF signal is healthy?\u003c\/p\u003e\n\u003cp\u003eA: Use an oscilloscope to inspect the RF carrier signal at the probe connector; a clean, consistent sine wave indicates proper probe and cable integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this be used for legacy system replacement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is designed for direct replacement of older 7200-series 11 mm and 14 mm transducer components, provided the matching probe and extension cable are also upgraded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518809268397,"sku":"330780-90-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330780-90-00-11mm-proximitor-sensor-1tii1alsmef.jpg?v=1766979419"},{"product_id":"330878-50-00-bently-nevada-3300-xl-nsv-proximitor-sensor","title":"330878-50-00 Bently Nevada 3300 XL NSv Proximitor Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330878-50-00 is a high-precision signal conditioning unit belonging to the Bently Nevada 3300 XL Narrow Side View (NSv) Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis Proximitor sensor is specifically engineered for critical machinery applications where standard 8 mm or 5 mm proximity systems cannot be utilized due to restricted internal clearances.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe NSv system is uniquely designed to operate in tight counterbores and areas with limited \"side-view\" clearance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eas it is immune to the magnetic interference from surrounding metal that often distorts signals in standard eddy-current sensors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis model is factory-calibrated for a 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter total system length,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a linear voltage output proportional to the gap between the probe tip and the target material.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330878-50-00 facilitates advanced diagnostic data for Turbine Supervisory Instrumentation (TSI) applications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Output:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-4 to -20 Vdc linear output,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating direct integration with Bently Nevada 3500 series racks or PLC\/DCS systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAverage Scale Factor (ASF):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7.\u003c\/span\u003e\u003cspan class=\"\"\u003e87 V\/mm (200 mV\/mil),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering high sensitivity for detection of minute vibration levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFixed for 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter system length (50 option),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erequiring matching 5m probes and extension cables for verified accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm (60 mils),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edelivering consistent measurement across a wide operating gap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSmall Target Accuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for monitoring radial vibration on shafts as small as 51 mm (2 inches) or axial position on targets down to 15 mm (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 inches).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eEngineering for Challenging Environments\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eConstructed to withstand the rigors of heavy industrial sectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330878-50-00 features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eElectromagnetic Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in RFI\/EMI immunity that meets European CE standards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring stable measurement signals without the need for specialized shielded conduits in high-noise environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Versatility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe compact housing supports both high-density DIN-rail mounting and traditional bulkhead installation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaximizing cabinet space efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Connection Stability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes SpringLoc terminal strips to provide tool-free,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration-resistant wiring connections,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reducing the risk of signal loss due to mechanical loosening.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServes as a modern,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehigh-performance replacement for older 3300 RAM,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3000-series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 7000-series transducer systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esimplifying facility modernization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePrimary Industrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 3300 XL NSv system is a vital component for protecting high-speed rotating assets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCentrifugal Air Compressors:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eReliable vibration monitoring in the restricted internal housings of air and process gas compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRefrigeration Units:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring thrust position and radial motion in compact chilling equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFluid-Film Bearing Machinery:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEssential for tracking shaft dynamic motion,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emisalignment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand bearing wear in medium-sized rotating assets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhase Reference Generation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding the clean,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estable pulse signals necessary for Keyphasor measurements and advanced rotor dynamic diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518810185901,"sku":"330878-50-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330878-50-00-proximity-sensor-x5urlb5la0n.jpg?v=1766979454"},{"product_id":"bently-nevada-330780-50-cn-proximity-sensor","title":"Bently Nevada 330780-50-CN Proximity Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330780-50-CN is a high-precision signal conditioning module belonging to the Bently Nevada 3300 XL 11 mm Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis Proximitor sensor is specifically engineered to provide an extended linear measurement range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it the primary choice for monitoring axial thrust position and radial vibration on large-scale rotating machinery.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy converting the eddy current signal from a non-contacting probe into a linear voltage output,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit facilitates the early detection of mechanical faults.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific model is factory-calibrated for a 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter total system length,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering high-fidelity signal conversion for critical assets where standard 8 mm sensors lack the necessary measurement envelope.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Electrical Integrity\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330780-50-CN is designed to deliver consistent diagnostic data within Turbine Supervisory Instrumentation (TSI) frameworks:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExtended Linear Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 4.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 mm (160 mil) linear measurement window,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enearly doubling the capacity of standard proximity systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eScale Factor:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides a nominal Average Scale Factor (ASF) of 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e94 V\/mm (100 mV\/mil).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConfigured for a 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter (16.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 ft) total loop length (50 option).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Supply Requirements:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperates efficiently between -17.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Vdc and -26 Vdc (barrier-free) or -23 Vdc to -26 Vdc (with barriers).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Stability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMaintains output accuracy within 2 mV per volt of input fluctuation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring reliable readings despite power supply noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Tolerance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRuggedized for industrial climates,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting an operational temperature range of -35°C to +85°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eEngineering Design and Field Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eBuilt for the rigors of power generation and heavy manufacturing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330780-50-CN incorporates several structural innovations:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Density Mounting:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe slim-profile housing is designed for efficient 35 mm DIN-rail mounting or traditional bulkhead installation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaximizing cabinet space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSpringLoc Terminal Strips:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures tool-free,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration-resistant wiring terminals that simplify field connections and prevent signal loss due to mechanical loosening.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eElectrical Isolation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated mounting base provides inherent isolation from the rail or panel,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eeliminating the need for separate isolator plates and reducing installation complexity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAdvanced Shielding:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered with superior RFI\/EMI immunity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emeeting European CE standards without the requirement for specialized shielded conduits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRegional Compliance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe CN suffix indicates specific regional certification and compliance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring the unit meets local regulatory standards for industrial monitoring equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePrimary Industrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs a critical component for protecting high-capital rotating assets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 11 mm Proximitor is utilized for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge Steam and Gas Turbines:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring axial displacement where significant thermal expansion or rotor movement is expected.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHydroelectric Units:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking radial shaft motion and centerline position on large-diameter vertical or horizontal shafts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCentrifugal Pumps and Compressors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEarly identification of rotor imbalance, misalignment, and bearing degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMachinery Protection Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect integration with Bently Nevada 3500 series racks for real-time asset analytics and automated protection trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518810316973,"sku":"330780-50-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330780-50-cn-proximity-sensor-aozmklxnljs.jpg?v=1766979461"},{"product_id":"bently-nevada-330850-90-cn-3300-xl-25mm-proximitor-sensor","title":"Bently Nevada 330850-90-CN 3300 XL 25mm Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 330850-90-CN is a specialized 25mm Proximitor sensor from Bently Nevada's 3300 XL series, engineered to provide advanced signal conditioning for large-scale displacement monitoring. This module acts as the sophisticated electronic core of a proximity transducer system, converting the eddy current signals from a 25mm probe into a linear voltage output. Specifically designed for applications requiring an extended linear range, this sensor is a critical component for Turbine Supervisory Instrumentation (TSI). Its high-grade construction ensures deterministic data acquisition, allowing for the precise tracking of mechanical motion in critical rotating assets where standard 8mm systems lack the necessary measurement depth.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters and Engineering Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 25 mm Proximity Transducer System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for extended displacement up to 10 mm (approx. 400 mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard -24 Vdc supply with a 50mA maximum current draw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Sensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecisely calibrated to 0.787 V\/mm (20 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of handling high-frequency data up to 50 kHz for rapid transient capture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP67 rated for complete protection against dust and temporary immersion in industrial fluids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to +185°F) for extreme industrial climates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCorrosion-resistant housing with CN-specific regional certification compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced RFI\/EMI shielding to prevent data distortion in electrically noisy motor rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Deployment and System Utilization\u003c\/h3\u003e\n\u003cp\u003eThe 330850-90-CN Proximitor is the primary choice for monitoring large-bore rotating machinery, such as massive steam turbines, hydroelectric generators, and large-scale industrial process compressors.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-2248 citation-end-2248\"\u003eBecause of the 25mm system's superior linear range, this sensor is ideally suited for monitoring differential expansion—tracking the relative movement between a machine's rotor and its casing during thermal startup cycles.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is also utilized for axial (thrust) position monitoring on heavy shafts where significant movement is expected. By delivering accurate, non-contacting measurement data to Bently Nevada 3500 series protection racks, the 330850-90-CN supports automated safety interlocks and sophisticated predictive maintenance programs, ensuring long-term operational reliability in the petrochemical and power generation sectors.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518819295405,"sku":"330850-90-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-90-cn-proximity-sensor-yyyxuue22dt.jpg?v=1766979480"},{"product_id":"bently-nevada-330850-50-05-proximitor-sensor-3300-xl-25mm","title":"Bently Nevada 330850-50-05 Proximitor Sensor 3300 XL 25mm","description":"\u003ch3 class=\"\"\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 330850-50-05 is a high-precision signal conditioner belonging to the 3300 XL 25 mm Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard 8 mm sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis 25 mm proximitor is engineered for \"Extended Range\" applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering a much larger linear measurement window.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt functions as the electronic core of an eddy current measurement chain,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the necessary excitation for the probe and converting the resulting impedance changes into a stable,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003elinear voltage output.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis system is indispensable for monitoring massive rotating assets where significant thermal expansion or large shaft displacements occur,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that critical safety data remains accurate even during extreme mechanical shifts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Parameters and Key Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330850-50-05 is designed to maintain high linearity and temperature stability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efulfilling the requirements of API 670 for machinery protection systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330850-50-05\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTransducer Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCalibrated specifically for 3300 XL 25 mm Proximity Probes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTotal System Length\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Meters (Option -50)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Option\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail and bulkhead mounting hardware included (Option -05)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12.\u003c\/span\u003e\u003cspan class=\"\"\u003e7 mm (500 mils),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estarting at approximately 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e63 mm (25 mils) from the probe face\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eScale Factor\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e787 V\/mm (20 mV\/mil)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFrequency Response\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 Hz (DC) to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-17.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Vdc to -26 Vdc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Signal\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Vdc to -17 Vdc (Gap dependent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTechnopolymer housing provides resistance to moisture and chemical contaminants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDue to its extended measurement range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330850-50-05 is the primary choice for monitoring large-scale Turbine Supervisory Instrumentation (TSI) parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDifferential Expansion (DE)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring the relative growth between a steam turbine’s rotor and its casing during thermal cycles to prevent internal contact.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRamp Differential Expansion\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking shaft movement in specialized turbine designs where standard proximity sensors lack the necessary range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge-Scale Hydroelectric Generators\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring shaft vibration and displacement in hydro turbines where large mechanical clearances are present.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Growth Analysis\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eQuantifying the physical expansion of machine housings and supports in high-temperature process environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStructural Displacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking the movement of large industrial components in refineries and power plants where sub-millimeter precision is required over a centimeter-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 330850-50-05 integrates seamlessly with Bently Nevada 3500 series racks, allowing for advanced diagnostic trending and automated machinery protection logic to safeguard high-value industrial infrastructure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518819852461,"sku":"330850-50-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330850-50-05-3300-xl-25-mm-proximitor-sensor-mctkx3ebbta.jpg?v=1766979500"},{"product_id":"bently-nevada-330980-50-00-3300-nsv-proximitor-sensor","title":"Bently Nevada 330980-50-00 3300 NSv Proximitor Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330980-50-00 is a high-precision signal conditioner belonging to the Bently Nevada 3300 Narrow Side View (NSv) Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis Proximitor sensor is specifically engineered for critical machinery where standard 8 mm or 5 mm proximity probes cannot be utilized due to extreme spatial constraints.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe NSv system is uniquely designed to operate in tight counterbores and areas with limited \"side-view\" clearance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eas it is immune to the magnetic interference from surrounding metal that often distorts signals in standard eddy-current sensors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis model is factory-calibrated for a 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter total system length,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a linear voltage output proportional to the gap between the probe tip and the target material.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330980-50-00 provides advanced diagnostic data for Turbine Supervisory Instrumentation (TSI) applications:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Output:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-4 to -20 Vdc linear output,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating direct integration with Bently Nevada 3500 series racks or PLC\/DCS systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAverage Scale Factor (ASF):\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e7.\u003c\/span\u003e\u003cspan class=\"\"\u003e87 V\/mm (200 mV\/mil),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering high sensitivity for detection of minute vibration levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFixed for 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter system length (50 option),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erequiring matching 5m probes and extension cables for verified accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm (60 mils),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edelivering consistent measurement across a wide operating gap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSmall Target Accuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for monitoring radial vibration on shafts as small as 51 mm (2 inches) or axial position on targets down to 15 mm (0.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 inches).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eEngineering for Challenging Environments\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eConstructed to withstand the rigors of heavy industrial sectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330980-50-00 features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eElectromagnetic Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in RFI\/EMI immunity that meets European CE standards,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring stable measurement signals without the need for specialized shielded conduits in high-noise environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Versatility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe compact housing supports both high-density DIN-rail mounting and traditional bulkhead installation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaximizing cabinet space efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Connection Stability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes SpringLoc terminal strips to provide tool-free,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration-resistant wiring connections,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reducing the risk of signal loss due to mechanical loosening.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLegacy Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServes as a modern,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehigh-performance replacement for older 3300 RAM,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3000-series,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand 7000-series transducer systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esimplifying facility modernization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePrimary Industrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 3300 NSv Proximitor is a vital component for protecting high-speed rotating assets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCentrifugal Air Compressors:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eReliable vibration monitoring in the restricted internal housings of air and process gas compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRefrigeration Units:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring thrust position and radial motion in compact chilling equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFluid-Film Bearing Machinery:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEssential for tracking shaft dynamic motion,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emisalignment,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand bearing wear in medium-sized rotating assets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhase Reference Generation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding the clean,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estable pulse signals necessary for Keyphasor measurements and advanced rotor dynamic diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518820212909,"sku":"330980-50-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330980-50-00-nsv-proximitor-sensor-jnnj45cnunn.jpg?v=1766979511"},{"product_id":"330525-00-bently-nevada-velomitor-xa-piezo-velocity-sensor","title":"330525-00 Bently Nevada Velomitor XA Piezo-Velocity Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 330525-00 is an \"Extended Application\" (XA) version of the industry-standard piezo-velocity sensor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eengineered specifically for high-reliability vibration monitoring in severe industrial climates.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis ruggedized transducer utilizes internal piezoelectric crystals to measure absolute casing vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting high-frequency acceleration signals into a stable velocity output.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEncased in a 316L stainless steel housing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330525-00 offers superior resistance to chemical corrosion and mechanical stress compared to standard sensors.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to bridge the gap between standard environmental monitoring and extreme-duty requirements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a robust solution for Turbine Supervisory Instrumentation (TSI) where traditional sensors might fail.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Parameters and Key Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Velomitor XA is characterized by its high-density construction and specialized electrical interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring consistent data acquisition in wet or dusty environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330525-00\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSensor Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePiezoelectric Velocity Transducer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHousing Material\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e316L Stainless Steel (Corrosion Resistant)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSensitivity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e94 mV\/mm\/s (100 mV\/in\/s) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFrequency Response\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Hz to 5 kHz (±3.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 dB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVelocity Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1270 mm\/s (50 in\/s) peak\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Thread\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1\/4-28 UNF (Option -00)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConnector Interface\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2-pin Mil-C-5015 with weatherproof seal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Rating\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIP65 and NEMA 4X (when used with appropriate mating cables)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-51°C to +121°C (-60°F to +250°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExcitation Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-24 Vdc (Current limited)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330525-00 is primarily utilized for monitoring the casing vibration of rotating assets where moisture ingress or chemical exposure is a constant threat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCooling Tower Fans\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring motor and gearbox vibration in 100% condensing humidity environments without the need for additional protective housings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHydroelectric Turbines\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTracking absolute vibration on guide bearings and headcovers where water spray and moisture are prevalent.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePetrochemical Process Pumps\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eContinuous surveillance of pump housings in outdoor locations exposed to corrosive vapors and heavy rain.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGeneral Purpose Steam Turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring absolute casing vibration to detect mechanical unbalance or bearing housing resonances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBalance of Plant (BoP) Assets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding reliable data for motors, fans, and blowers in refineries and power generation plants where NEMA 4X protection is mandatory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe integration of the weatherproof connector allows for a simplified installation footprint, enabling maintenance teams to achieve reliable machinery protection in space-constrained or exposed locations while maintaining full compatibility with the Bently Nevada 3500 monitoring system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518820999341,"sku":"330525-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330525-00-velomitor-xa-piezo-velocity-sensor-1d1m2yky33v.jpg?v=1766979533"},{"product_id":"84661-06-bently-nevada-proximity-probes-extension-cables","title":"84661-06 Bently Nevada Proximity Probes Extension Cables","description":"\u003cp\u003eConfigured for signal path extension in machinery monitoring networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 84661-06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e84661-06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes) provides direct physical and electrical execution of eddy-current transducer signal transmission between the proximity probe and the monitoring system interface.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Logic\u003c\/h3\u003e\n\u003cp\u003eThe 84661-06 is a fixed-length extension cable assembly designed for specific transducer loop configurations. No field-adjustable sub-modules are present in this assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e84661-06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 x 25 x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop signal path)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe signal integrity of the 84661-06 is predicated on strict adherence to eddy-current probe scaling protocols. The assembly ensures that the 7.87 V\/mm (200 mV\/mil) sensitivity is maintained across the transmission line. During installation, gap voltage validation targets of -10 VDC at the monitor input are required to ensure the transducer system operates within its linear range. Precise cable length selection is mandatory to manage impedance and prevent phase distortion of the dynamic signals derived from shaft displacement and rotor dynamics. Cross-talk suppression is achieved by maintaining physical separation from high-voltage AC lines and ensuring shield continuity at all connection points.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e84661-06 Extension Cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector protection caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Handling: Inspect mating surfaces for contamination. Ensure connectors are tightened by hand until the locking mechanism is fully engaged. Do not use tools to torque coaxial connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Requirements: Install cables within grounded rigid metallic conduit to prevent signal degradation and mechanical damage to the coaxial jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 5 times the cable diameter to prevent dielectric deformation and resulting changes in characteristic impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Terminate the cable shield to a clean instrument ground at the instrumentation cabinet to avoid ground loops and associated 50\/60 Hz interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable assembly compatible with non-Bently Nevada transducer systems?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The assembly is impedance-matched for Bently Nevada eddy-current transducer systems. Use with other systems will cause signal scaling errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the 84661-06 cable be spliced or shortened to fit a specific distance?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. Altering the cable length modifies the total loop impedance and invalidates the factory-calibrated system accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum distance supported by this extension cable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The extension cable is a calibrated component of the total system loop, typically either 5 meters or 9 meters. Verify the system requirements before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does shield continuity affect the sensor output?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The shield is required to prevent electromagnetic interference. A break in shield continuity will introduce noise floors that manifest as signal errors in vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this connector rated for use in humid or wet environments?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The miniature coaxial connectors are designed for protected, dry environments. Use a sealed junction box if the cable is routed in harsh conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What are the symptoms of an impedance mismatch?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Mismatches typically manifest as non-linear transducer output, reduced frequency response, or unexpected phase shifts in the vibration signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this cable for high-temperature applications up to 177 deg C?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the cable materials are rated for this temperature range, provided there is no mechanical stress or vibration-induced abrasion on the cable jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 84661-06 cable hot-swappable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. Disconnecting a probe cable while the machine is running will result in a loss of transducer signal and may trigger an alarm or trip in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518821359789,"sku":"84661-06","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-84661-06-sensor-proximity-probe-cable-23mwgnbr03g.jpg?v=1766979544"},{"product_id":"bently-nevada-106765-16-interconnect-cable-transducer","title":"Bently Nevada 106765-16 Interconnect Cable Transducer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 106765-16\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e106765-16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable, operates as a dedicated hardware component for high-fidelity proximity signal transmission within Turbine Supervisory Instrumentation (TSI) systems. It connects proximity probes or acceleration transducers directly to proximity sensor extension cables or rack-mounted monitor modules, ensuring the raw electrical signal paths remain unaltered over designated distances.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e106765-16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransducer Interconnect Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConductor Structure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwisted, shielded copper pairs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (0 mA internal consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum 100 M\\Omega\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Vrms connection-to-shield\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.3 x 20.3 x 5.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% condensing when properly sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe physical layout of this interconnect link matches specific system capacitance and impedance boundaries to maintain linear eddy-current probe scaling values across the full scale. Preserving these electrical properties allows accurate gap voltage validation, targeting the standard -10 VDC operational centers required by proximity monitors. This precision reduces impedance mismatch reflection anomalies, preventing voltage offsets that distort critical rotor dynamics analysis and fluid-film bearing displacement loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Diagnostic Logic\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal shield structure mitigate signal degradation across long routing runs?\u003c\/p\u003e\n\u003cp\u003eA: The twisted pair geometry combined with a continuous aluminum foil shield provides high-performance cross-talk suppression. This layout prevents electrostatic and electromagnetic noise from modulating the high-frequency carrier wave sent by the proximity sensor.\u003c\/p\u003e\n\u003cp\u003eQ: What operational failures occur if the cable insulation resistance drops below 100 M\\Omega?\u003c\/p\u003e\n\u003cp\u003eA: A drop in insulation resistance creates a parallel leakage path to ground. This alters the constant-current drive loop, shifts the target gap voltage outside validation limits, and introduces measurement drift in the active vibration channel.\u003c\/p\u003e\n\u003cp\u003eQ: Can this passive cable assembly be modified or spliced in the field during turnaround?\u003c\/p\u003e\n\u003cp\u003eA: No. Splicing alters the intrinsic line capacitance and resistance parameters per unit length. Any manual field modifications invalidate the factory eddy-current probe scaling, inducing measurement errors within the associated machinery protection monitor.\u003c\/p\u003e\n\u003ch3\u003eField Component Installation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Boundary:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the integrated copper drain wire exclusively to the instrument ground terminal strip at the monitor enclosure end. Isolate the field transducer end of the shield completely to prevent ground loop currents from skewing voltage feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Bend Constraints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum structural bend radius of 25.4 mm during installation routing. Sharp kinks or tight bends degrade the physical dielectric separation layer, shifting the operational capacitance parameters of the wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit and Terminal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRun the interconnect cabling inside solid or flexible dedicated metallic conduit systems. Seal all connection boxes to prevent moisture accumulation, oil ingress, or chemical exposure from breaking down the outer insulation jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcurement Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 106765-16 Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Engineering Pinout Terminal Reference Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Proximity sensors, extension cables, and threaded bulkhead connectors are not included with this component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Logistics \u0026amp; Protocols\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish verification is logged in the system. Dispatches depart from Xiamen, China via prioritized transport networks handled by DHL, FEDEX, or UPS. The components travel enclosed within sealed anti-static industrial packaging matrices with moisture-absorbent packets to guarantee physical shielding and eliminate ESD degradation vectors during transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518821818541,"sku":"106765-16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-106765-16-interconnect-cable-o5l3cx42jxw.jpg?v=1766979560"},{"product_id":"84661-20-bently-nevada-interconnect-cable-velomitor-series","title":"84661-20 Bently Nevada Interconnect Cable Velomitor Series","description":"\u003cp\u003eConfigured for seismic vibration signal transmission, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 84661-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e84661-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cable) provides direct electrical connectivity for piezoelectric Velomitor sensor signals within industrial monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Decomposition\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e84661\u003c\/strong\u003e: Base Model (Velomitor Interconnect Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e20\u003c\/strong\u003e: Cable Length (20 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e84661-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 20 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-50 deg C to +200 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive signal path\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-impedance voltage (Velomitor output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 84661-20 cable maintains the integrity of the seismic signal generated by Velomitor sensors. By utilizing shielded conductors, the cable prevents high-frequency electromagnetic interference from corrupting the low-level vibration data. Precise impedance control is preserved throughout the signal path, which is critical for maintaining the frequency response accuracy required for rotor dynamics assessment. Cross-talk suppression between adjacent sensor channels is managed through high-quality shielding, ensuring that seismic acceleration data remains isolated during transmission to the monitoring system.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 84661-20 Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector instruction sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Routing: Install the cable through grounded metallic conduit to provide mechanical shielding and environmental protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Adhere to the manufacturer-specified minimum bend radius to prevent internal conductor damage or shield breach.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Integrity: Verify all terminal connections are clean and free of oxidation; ensure mating parts are fully seated to maintain environmental seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Terminate the cable shield at the designated ground reference point of the monitoring module to mitigate ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration Stress: Secure the cable at intervals using appropriate clamps to prevent mechanical strain on the sensor connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be spliced if it is too short?\u003c\/p\u003e\n\u003cp\u003eA: Splicing is not recommended as it disrupts the shielding continuity and introduces impedance discontinuities, which degrades vibration signal quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable compatible with all Velomitor sensors?\u003c\/p\u003e\n\u003cp\u003eA: It is compatible with standard Velomitor series sensors utilizing the specified connector interface; verify sensor documentation for compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the shielding on this cable?\u003c\/p\u003e\n\u003cp\u003eA: The shield protects the low-level analog vibration signal from electromagnetic interference and radio frequency noise present in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I test the cable for continuity?\u003c\/p\u003e\n\u003cp\u003eA: Perform a point-to-point resistance measurement between connector pins; confirm low resistance for signal paths and high resistance between signals and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the cable be used in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cable is rated for operation up to 200 deg C; ensure installation locations do not exceed this threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a failure in the interconnect cable?\u003c\/p\u003e\n\u003cp\u003eA: Failure is indicated by loss of signal, erratic noise floor, or signal drift observed at the monitoring module input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the connectors moisture-resistant?\u003c\/p\u003e\n\u003cp\u003eA: Connectors are designed to resist industrial moisture, but they should be used with appropriate conduit seals in wet or wash-down areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How should the cable be secured to the machine?\u003c\/p\u003e\n\u003cp\u003eA: Use rubber-lined clamps or cable ties at regular intervals to prevent excessive movement or chafing against vibrating machinery components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518821884077,"sku":"84661-20","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-84661-20-velomitor-interconnect-cable-dddzjlqn5ob.jpg?v=1766979563"},{"product_id":"bently-nevada-330881-28-08-090-00-02-proximity-transducer-3300-xl-series","title":"Bently Nevada 330881-28-08-090-00-02 Proximity Transducer 3300 XL Series","description":"\u003cp\u003eConfigured for non-contacting displacement monitoring in mechanical platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-08-090-00-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881-28-08-090-00-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical and electrical execution of RF-based position signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eSuffix Model Decomposition\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: Base Model (3300 XL PROXPAC Proximity Transducer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e28\u003c\/strong\u003e: Probe Diameter (8 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: Mounting Thread (Metric 3\/8-24 style)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e090\u003c\/strong\u003e: Total System Length (9.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector Type (Standard connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval (Multiple international standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-08-090-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 cm x 25 cm x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL system utilizes eddy-current probe scaling to convert shaft motion into a linear voltage signal. During installation, gap voltage validation against -10 VDC targets at the system interface is required to ensure the probe tip operates within the optimal linear range. The system supports rotor dynamics analysis by maintaining signal linearity. Cross-talk suppression is maintained through frequency-coded transducer electronics, preventing signal interference between adjacent sensors in high-density monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330881-28-08-090-00-02 PROXPAC XL Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective connector thread cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Install the transducer housing to the mounting bracket; ensure the probe tip air gap is set to achieve the -10 VDC operational target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Route coaxial cabling through grounded metallic conduit to prevent electromagnetic interference; observe minimum bend radius constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the transducer housing to the machine ground reference to establish a stable electrical signal return path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Verification: Inspect all connectors for contaminants and ensure hand-tightened security prior to startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Validation: Confirm the static gap voltage using a high-impedance voltmeter at the transducer output before machine engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the PROXPAC XL compatible with standard external Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: No, the PROXPAC XL integrates the oscillator within the transducer housing, functioning as a standalone unit without an external Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the 9.0 meter cable be field-modified?\u003c\/p\u003e\n\u003cp\u003eA: No, the cable length is calibrated to the specific internal resonant frequency of the transducer; modification invalidates the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe gap validated during installation?\u003c\/p\u003e\n\u003cp\u003eA: Measure the output voltage at the transducer signal terminals; the system target is -10 VDC at the specified nominal air gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the effect of target material on transducer output?\u003c\/p\u003e\n\u003cp\u003eA: Probe sensitivity is factory-calibrated for 4140 steel; other materials require a scaling correction factor to ensure measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this device suitable for high-vibration environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit is constructed to withstand industrial vibration profiles provided the housing is securely mounted to a rigid bracket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the transducer require an external power supply?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit requires a -24 VDC power source to excite the internal oscillator and generate the displacement signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What causes unstable or drifting signal readings?\u003c\/p\u003e\n\u003cp\u003eA: Instability is typically caused by loose electrical connections, ground loops, or physical damage to the probe tip\/coaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Should thread-locking compound be used during installation?\u003c\/p\u003e\n\u003cp\u003eA: No, thread-locking compounds may create an insulating barrier that disrupts the critical electrical ground path between the probe and machine housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822047917,"sku":"330881-28-08-090-00-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-08-090-00-02-proxpac-xl-proximity-transducer-52xwp4tfapj.jpg?v=1766979570"},{"product_id":"330881-28-00-148-03-02-bently-nevada-3300-xl-series-proximity-transducer","title":"330881-28-00-148-03-02 Bently Nevada 3300 XL Series Proximity Transducer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-00-148-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881-28-00-148-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer, operates as a dedicated hardware component for non-contacting displacement measurement within 3300 XL PROXPAC transducer systems.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: Base Model (3300 XL PROXPAC Proximity Transducer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e28\u003c\/strong\u003e: Probe Diameter (8 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Mounting Thread (Standard configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e148\u003c\/strong\u003e: Total System Length (14.8 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Connector Type (ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval (Multiple international standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-00-148-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 cm x 30 cm x 20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL system utilizes eddy-current probe scaling to convert non-contacting shaft displacement into a linearized voltage output. During commissioning, gap voltage validation against -10 VDC targets ensures the probe tip operates within its defined linear measurement range. The system facilitates rotor dynamics analysis by maintaining signal linearity across the air gap. Cross-talk suppression is achieved through frequency-coded probes, which prevent signal interference when multiple sensors are installed in high-density monitoring racks.\u003c\/p\u003e\n\u003ch3\u003e## Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330881-28-00-148-03-02 Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector thread protection caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Mounting: Install the transducer housing to a rigid machine surface; ensure the probe tip is secured at the required gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination: Connect the -24 VDC power supply and signal output using shielded cable; ensure correct polarity at the termination points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the transducer housing to the machine ground reference to ensure stable electrical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Protection: Route all signal wiring through grounded rigid conduit to mitigate electromagnetic interference from rotating equipment fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Verification: Use a high-impedance voltmeter to verify that the static gap voltage meets the -10 VDC target before machine startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the PROXPAC XL compatible with standard external Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: No, the PROXPAC XL integrates the oscillator within the transducer housing, eliminating the requirement for a separate Proximitor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the 14.8 meter cable be modified in the field?\u003c\/p\u003e\n\u003cp\u003eA: No, the system is factory-calibrated for a specific length; modifying the cable alters the electrical resonance and invalidates the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I check for signal integrity?\u003c\/p\u003e\n\u003cp\u003eA: Observe the RF carrier signal with an oscilloscope or verify that the DC output voltage corresponds to the physical air gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this unit support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: The unit can be replaced, provided power is isolated before disconnecting wiring to prevent electrical faults or false alarm triggers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum signal output distance?\u003c\/p\u003e\n\u003cp\u003eA: Signal transmission can achieve up to 300 meters using appropriate low-capacitance, shielded instrumentation cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this device compatible with third-party monitoring systems?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility depends on the monitoring system's ability to accept a -24 VDC powered, standard proximity voltage output signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the 14.8 meter cable length specified?\u003c\/p\u003e\n\u003cp\u003eA: This is the factory-set resonant length required to maintain the specified electrical sensitivity and frequency response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is ground loop noise mitigated?\u003c\/p\u003e\n\u003cp\u003eA: The system uses a single-point ground connection via the transducer housing to prevent ground loops and electrical noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822375597,"sku":"330881-28-00-148-03-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-00-148-03-02-proxpac-xl-proximity-transducer-sdmr1wglweu.jpg?v=1766979586"},{"product_id":"330500-02-04-bently-nevada-velomitor-piezo-velocity-sensors","title":"330500-02-04 Bently Nevada Velomitor Piezo-velocity Sensors","description":"\u003cp\u003eConfigured for absolute casing vibration velocity measurement in 3500 Machinery Protection Systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330500-02-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePiezo-velocity Sensors) provides direct physical\/electrical execution. The hardware utilizes internal piezoelectric crystal structures and integrated solid-state charge amplifiers to output a continuous low-impedance AC voltage signal directly proportional to the vibration velocity vector of the machine casing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Combination Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Mounting Adapter Suffix):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM10 x 1 threaded mounting adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04 (Agency Approval Suffix):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple regional approvals including ATEX, IECEx, and North American hazardous area certifications (Class I, Division 1 \/ Zone 0)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330500-02-04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 x 8.0 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-54 to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal loop voltage supply (Bias current powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 mV\/mm\/s (100 mV\/in\/s) plus\/minus 5% nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Hz to 5.0 kHz plus\/minus 3.0 dB nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmplitude Saturation Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 mm\/s (5.0 in\/s) peak maximum velocity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Termination\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pin Mil-C-5015 hermetic top connector assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCasing Vibration Integration and Rotor Dynamics Context\u003c\/h3\u003e\n\u003cp\u003eWhile eddy-current probe scaling tracks relative physical displacement of an internal shaft, this piezoelectric hardware measures absolute mechanical acceleration and automatically integrates the field signal into structural velocity targets. It tracks parameters linked to secondary machine casing transfers and casing-to-rotor dynamics loops. The internally isolated circuitry produces a steady DC bias voltage loop to verify cross-talk suppression and loop continuity. This internal architectural layout rejects external structural field anomalies, mitigating high-frequency harmonic distortion from reaching adjacent acceleration transducers or overlapping monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eProcurement Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) integrated Bently Nevada 330500 Velomitor piezo-velocity sensor with an M10 x 1 threaded mounting stud adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory calibration verification protocol data sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate components including Mil-C-5015 2-wire shielded cable extensions and terminal monitor blocks are excluded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDistribution Logistics Standards\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDispatches are finalized within 2-7 days when payment finish verification clears in the global tracking database.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFreight Methods:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransport is executed via priority international express services including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll components travel sealed inside hermetic anti-static industrial packaging to negate latent mechanical or electrostatic breakdown risks during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Surface Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachine the casing sensor pad until it is completely flat to a tolerance profile of 0.8 micrometers Ra. Apply a standard film of industrial silicone grease or structural coupling fluid to the thread base before mechanical securement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Mechanical Torquing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManually seat the M10 x 1 stud into the casing housing port, then engage the sensor body using a calibrated torque wrench to a maximum tightening limit of 4.5 N-m (40 in-lb). Do not over-torque to prevent permanent damage to the internal piezoelectric crystal stack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Strain and Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeat the 2-pin Mil-C-5015 connector ensuring the internal elastomer o-ring compresses completely to keep the housing isolated. Route the twisted pair shielded line inside rigid steel conduit paths, terminating the outer shield wire exclusively at the instrument rack ground plane to preserve cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is field sensor health monitored if the module does not utilize standard gap voltage validation targets?\u003c\/p\u003e\n\u003cp\u003eA: The sensor relies on continuous internal DC bias voltage monitoring over the 2-wire line. Under normal operating states without faults, the circuit outputs a steady bias voltage between 10 VDC and 14 VDC. Voltages shifting outside this window signal a crushed field line or internal component fault.\u003c\/p\u003e\n\u003cp\u003eQ: Can this sensor be deployed on an ungrounded machine structure without losing signal fidelity?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The internal crystal array and solid-state charge conversion electronics are completely isolated from the outer stainless-steel sensor casing. This design preserves cross-talk suppression and blocks local ground loop noise.\u003c\/p\u003e\n\u003cp\u003eQ: Can this velocity sensor be field calibrated to modify its nominal scale factor sensitivity?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal integration matrix is laser-welded and sealed hermetically at the factory. No adjustments can be performed in the field; sensors deviating from the 3.94 mV\/mm\/s baseline during loop checks must be returned for factory recertification.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822441133,"sku":"330500-02-04","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330500-02-04-velomitor-piezo-velocity-sensors-xuajotfakwv.jpg?v=1766979590"},{"product_id":"bently-nevada-330881-28-00-050-03-02-3300-xl-series-proximity-transducer","title":"Bently Nevada 330881-28-00-050-03-02 3300 XL Series Proximity Transducer","description":"\u003cp\u003eConfigured for displacement signal conditioning in mechanical monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-00-050-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881-28-00-050-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical\/electrical execution of RF proximity data conversion.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix Decomposition\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: Base Model (3300 XL PROXPAC Proximity Transducer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e28\u003c\/strong\u003e: Probe Diameter (Standard configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Mounting Thread (Standard configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e050\u003c\/strong\u003e: Total System Length (5.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Connector Type (ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval (Multiple standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-00-050-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 cm x 30 cm x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC (nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL PROXPAC transducer utilizes eddy-current probe scaling to convert non-contacting shaft displacement into a linearized voltage output. During site commissioning, gap voltage validation against -10 VDC targets ensures the probe tip is within the calibrated linear range. Rotor dynamics are monitored through high-frequency oscillator signal demodulation. Cross-talk suppression is achieved through frequency-coded probes, preventing signal interference between adjacent sensor channels in multi-point monitoring racks.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330881-28-00-050-03-02 Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector thread protection caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Mounting: Mount the transducer housing to a rigid machine surface; ensure the probe tip is secured at the required gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination: Connect the -24 VDC power supply and signal output using shielded cable; maintain correct polarity at the terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the transducer case to the machine ground reference to ensure stable electrical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Shielding: Route all signal wiring through grounded rigid conduit to mitigate electromagnetic interference from rotating equipment fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Verification: Use a high-impedance voltmeter to verify that the static gap voltage meets the -10 VDC target before machine startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the PROXPAC XL compatible with external Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: No, the PROXPAC XL integrates the oscillator and housing into a single physical unit, eliminating the need for a separate Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the probe cable be extended or shortened?\u003c\/p\u003e\n\u003cp\u003eA: No, the system is factory-calibrated for a specific length; modifying cable lengths alters electrical resonance and invalidates the scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I check for signal integrity?\u003c\/p\u003e\n\u003cp\u003eA: Use an oscilloscope to observe the RF carrier signal at the probe connector or verify the DC voltage output corresponds to the physical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this unit support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit can be replaced, but power must be isolated before disconnecting wiring to avoid potential electrical surges or false signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum distance for the signal output?\u003c\/p\u003e\n\u003cp\u003eA: Output signals typically support transmission up to 300 meters using low-capacitance, shielded instrumentation cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this device compatible with non-Bently monitoring systems?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is contingent on the monitoring system accepting a -24 VDC powered, standard proximity voltage output signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the 5.0 meter cable length specified?\u003c\/p\u003e\n\u003cp\u003eA: The cable length is factory-set to match the system's electrical resonance for optimal signal transmission accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is ground loop noise mitigated?\u003c\/p\u003e\n\u003cp\u003eA: The system utilizes a single-point ground connection via the transducer housing to prevent ground loops and noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822637741,"sku":"330881-28-00-050-03-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-00-050-03-02-proxpac-xl-proximity-transducer-vkxggatcw2v.jpg?v=1766979596"},{"product_id":"bently-nevada-330881-16-00-307-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-16-00-307-06-02 PROXPAC XL Proximity Transducer","description":"\u003cp\u003eConfigured for displacement signal conditioning in mechanical monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-16-00-307-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881-16-00-307-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical\/electrical execution of RF proximity data conversion.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix Decomposition\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: Base Model (3300 XL PROXPAC Proximity Transducer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16\u003c\/strong\u003e: Probe Diameter (8 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Mounting Thread (Standard configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e307\u003c\/strong\u003e: Total System Length (3.07 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: Connector Type (ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval (Multiple international standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-16-00-307-06-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL PROXPAC transducer utilizes eddy-current probe scaling to convert non-contacting shaft displacement into a linearized voltage output. During commissioning, gap voltage validation against -10 VDC targets is performed to confirm the probe operates within the linear range. The device facilitates rotor dynamics analysis by maintaining signal linearity across the air gap. Cross-talk suppression is maintained via internal frequency tuning, which prevents signal interference when multiple sensors are mounted in high-density machine configurations.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330881-16-00-307-06-02 Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread protection caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Install the transducer housing to a rigid machine surface; ensure the probe tip is secured at the required gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Cabling: Connect the -24 VDC supply and signal output using shielded instrumentation cable; maintain strict polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the transducer case to the machine ground reference to ensure stable electrical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Protection: Route all signal wiring through grounded rigid conduit to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Verification: Use a high-impedance voltmeter to confirm the static gap voltage meets the -10 VDC target prior to machine rotation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the PROXPAC XL compatible with external Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: No, the PROXPAC XL integrates the oscillator within the transducer housing, eliminating the need for a separate Proximitor unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the cable be field-modified?\u003c\/p\u003e\n\u003cp\u003eA: No, the cable length is calibrated to match the system resonance; any modification will invalidate the transducer scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is signal integrity checked?\u003c\/p\u003e\n\u003cp\u003eA: Monitor the RF carrier signal with an oscilloscope or verify that the DC output voltage corresponds to the physical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this unit support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: The unit can be replaced, provided power is isolated beforehand to prevent electrical faults during disconnection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum signal output distance?\u003c\/p\u003e\n\u003cp\u003eA: Signal transmission can achieve up to 300 meters using appropriate low-capacitance, shielded instrumentation cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this device compatible with third-party monitoring systems?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility depends on the system's ability to accept a -24 VDC powered, standard proximity voltage output signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is a 3.07 m length specified?\u003c\/p\u003e\n\u003cp\u003eA: This is the factory-set resonant length required to maintain the specified electrical sensitivity and frequency response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is ground loop noise mitigated?\u003c\/p\u003e\n\u003cp\u003eA: The system employs a single-point ground connection via the transducer housing to prevent noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822801581,"sku":"330881-16-00-307-06-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-16-00-307-06-02-proxpac-xl-proximity-transducer-jimhqx0440p.jpg?v=1766979603"},{"product_id":"330881-16-00-200-06-02-bently-nevada-proximity-transducer-3300-xl-series","title":"330881-16-00-200-06-02 Bently Nevada Proximity Transducer 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-16-00-200-06-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881-16-00-200-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer, operates as a dedicated hardware component for displacement signal conditioning within 3300 XL Proximitor systems.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330881-16-00-200-06-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: 3300 XL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Suffixes define probe length, mounting threads, connector type, and cable armor specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-16-00-200-06-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer \/ External oscillator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRF proximity modulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI Mechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe system employs eddy-current probe scaling to generate a precise displacement signal from shaft motion. During setup, gap voltage validation against -10 VDC targets ensures the probe tip is positioned accurately within the linear range. Rotor dynamics are monitored through high-frequency RF oscillation, which is demodulated to represent shaft radial or axial position. Cross-talk suppression is achieved through specific frequency tuning of the oscillator, allowing multiple probes to operate in proximity without signal interference.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330881-16-00-200-06-02 Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector protector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Positioning: Install the probe into the mounting bracket; set the physical gap using a feeler gauge to match the nominal -10 VDC gap voltage target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use factory-supplied coaxial cables; ensure all connections are torqued to specifications and secured against vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the transducer body to the machine case ground to maintain a stable electrical reference for the eddy-current field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure coaxial cables are routed through grounded rigid conduit to minimize electromagnetic interference from external sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInitialization: Verify signal continuity and static gap voltage at the monitor or oscillator input prior to machine rotation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the probe cable be cut or spliced?\u003c\/p\u003e\n\u003cp\u003eA: No, the system is calibrated as a complete set including the probe, extension cable, and Proximitor; modifying the cable length alters the electrical resonance and calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the gap voltage measured?\u003c\/p\u003e\n\u003cp\u003eA: Measure the voltage between the \"OUT\" and \"COM\" terminals of the Proximitor using a high-impedance digital voltmeter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the probe tip sensitive to temperature?\u003c\/p\u003e\n\u003cp\u003eA: The probe is rated for high-temperature service; however, significant temperature changes can induce small drift in the gap voltage, which should be accounted for during baseline checks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the armor on the cable?\u003c\/p\u003e\n\u003cp\u003eA: The armored cable provides mechanical protection against debris and vibration-induced wear in harsh industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this probe with a non-Bently Nevada monitor?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility depends on the monitoring system's ability to provide the required excitation frequency and process the standard -24 VDC proximity signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What should I do if the signal is erratic?\u003c\/p\u003e\n\u003cp\u003eA: Inspect the probe tip for damage, ensure all connectors are clean and tight, and verify that the coaxial cable is free of insulation breaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the transducer require a specific mounting clearance?\u003c\/p\u003e\n\u003cp\u003eA: Yes, probes must be mounted with sufficient radial clearance from surrounding metal to prevent interference with the electromagnetic field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify the oscillation frequency?\u003c\/p\u003e\n\u003cp\u003eA: Use an oscilloscope to verify the RF carrier frequency at the probe connector; it must match the rating of the matched Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823325869,"sku":"330881-16-00-200-06-02","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-16-00-200-06-02-proxpac-xl-proximity-transducer-05d2grpxjdb.jpg?v=1766979619"},{"product_id":"330881-16-05-150-00-02-bently-nevada-proxpac-xl-series-proximity-transducers","title":"330881-16-05-150-00-02 Bently Nevada PROXPAC XL Series Proximity Transducers","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-16-05-150-00-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer, operates as a dedicated hardware component for non-contacting shaft displacement, vibration, and speed measurements within PROXPAC XL Series monitoring assemblies.\u003c\/p\u003e\n\u003ch3\u003eOption Breakdown Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: PROXPAC XL Proximity Transducer Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-16\u003c\/strong\u003e: Probe option (3300 XL 8 mm probe with 3\/8-24 UNF thread)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Unthreaded length (0.5 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-150\u003c\/strong\u003e: Overall case length (15.0 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Total system length (5.0 m \/ 16.4 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Agency approval option (ATEX \/ IECEx \/ North American hazardous area certifications)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-16-05-150-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e52.0 cm x 18.0 cm x 18.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C (probe tip); -34 deg C to +85 deg C (housing and internal electronics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRequires -24 VDC nominal supply input from monitoring system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) starting at approximately 0.25 mm (10 mils) from target surface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when properly gap-matched to AISI 4140 steel target\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect analog voltage modulated via eddy-current proximity principle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe integrated assembly operates via high-frequency eddy-current probe scaling, relying on the magnetic properties of standard AISI 4140 steel to translate physical proximity into a proportional electrical signal. When configuring the internal Proximitor circuitry contained within the specialized PROXPAC housing, field verification of rotor dynamics demands strict attention to cross-talk suppression. If multiple transducer housings are mounted in immediate adjacency along a continuous shaft line, the separation distance must adhere to strict geometric constraints to ensure the RF fields from the 8 mm probe tips do not overlap, which would induce phantom vibration frequencies or false gap tracking errors on the safety backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Kit Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330881-16-05-150-00-02 PROXPAC XL Assembly (comprising integrated probe, case mechanism, and internal electronics)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Heavy-duty conduit mounting locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x External housing ground lug fastener pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory test calibration report and safety certification certificate packet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation and Grounding Standards\u003c\/h3\u003e\n\u003cp\u003eMounting the PROXPAC XL housing requires rigid attachment to the machine casing to prevent external structural resonances from introducing signal errors into the rotor dynamics data loop. Thread the assembly into the mounting port, tracking the DC gap voltage in real time at the terminal block until hitting the -10.0 VDC calibration target, denoting the midpoint of the linear range. Secure the outer locknuts to lock this mechanical position. The outer aluminum enclosure must be tied to local structural ground via the external ground lug using minimum 4 mm sq copper conductors. Field signal cables must be run inside dedicated flexible liquid-tight conduit attached to the housing hub. Coaxial cable shields must be kept isolated from the housing interior and terminated solely at the monitor rack instrument ground plane to prevent ground loop contamination of the measurement signal.\u003c\/p\u003e\n\u003ch3\u003ePacking and Transport Protocols\u003c\/h3\u003e\n\u003cp\u003eDispatched within 2-7 days when payment finish, with all routing managed via DHL\/FEDEX\/UPS premium global freight lines. The product is shipped in custom anti-static industrial packaging featuring double-walled corrugated outer containers, moisture barrier bags, and precision-cut polyethylene closed-cell foam beds designed to immobilize the long outer casing and prevent shock damage to the sensitive internal eddy-current tip components.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal electronic module handle live loop disconnections during service checks?\u003c\/p\u003e\n\u003cp\u003eA: Unplugging or disconnecting the internal signal wires while the -24 VDC power loop is active drives the monitor input to an immediate open-circuit state. The monitoring module identifies this as a \"Not OK\" fault status rather than a trip event, disabling active safety relays for that specific channel to eliminate false machinery shutdown triggers.\u003c\/p\u003e\n\u003cp\u003eQ: Does this model allow field adjustment of the internal Proximitor tuning for different shaft metals?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal electronics are factory-tuned to the standard scale factor of 7.87 V\/mm matching AISI 4140 steel targets. Adjusting the physical position changes the gap voltage but will not correct for incorrect target metallurgy; structural recalibration or software scale factor adjustments at the monitor rack are required if target metallurgy deviates from specification.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum distance the signal can travel from the internal PROXPAC terminal block to the monitor rack?\u003c\/p\u003e\n\u003cp\u003eA: The standard 5.0-meter system length matches the internal probe and cable tuning inside the assembly. From the PROXPAC housing terminal block, field wiring using twisted, shielded 3-conductor cable can be run up to 305 meters (1000 feet) to the 3500 monitor rack without experiencing signal degradation or loss of frequency response.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823424173,"sku":"330881-16-05-150-00-02","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-16-05-150-00-02-proxpac-xl-proximity-transducer-2joy5yszbs0.jpg?v=1766979624"},{"product_id":"177230-01-01-05-bently-nevada-seismic-transmitter-3300-xl","title":"177230-01-01-05 Bently Nevada Seismic Transmitter 3300 XL","description":"\u003cp\u003eConfigured for casing vibration velocity measurement in rotating machinery loops, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 177230-01-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e177230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeismic Transmitter) provides direct physical\/electrical execution. This self-contained piezoelectric device processes raw internal acceleration into a continuous analog loop signal proportional to overall vibration velocity, interfacing directly with external control systems without the necessity of a separate processing monitor rack.\u003c\/p\u003e\n\u003ch3\u003eOption Code Matrix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e177230:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase Model (Seismic Vibration Transmitter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasurement Range Option (0 to 25.4 mm\/s or 0 to 1.0 in\/s nominal full-scale)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFrequency Response Option (10 Hz to 1.0 kHz bandwidth limits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMounting Thread\/Agency Approval Option (M8 x 1.25 mounting stud with multi-national hazardous area certifications)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e177230-01-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA DC (current loop configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 30 VDC loop powered\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 x 8.0 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensing Element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePiezoelectric crystal matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal sensing geometry of this seismic transmitter is engineered to mechanically reject non-axial vibration vectors, allowing isolated measurement of specific casing dynamics. By suppressing transverse electrical and mechanical variables, the transmitter ensures accurate cross-talk suppression when mounted near opposing radial or axial eddy-current probes tracking fluid-film bearing behavior. The resulting 4-20 mA loop output correlates with baseline rotor dynamics parameters, allowing standard process controllers to log step-changes in overall structural velocity.\u003c\/p\u003e\n\u003ch3\u003eInterface Technical Diagnostics\u003c\/h3\u003e\n\u003cp\u003eQ: Can this transmitter interface be integrated with live loops supporting hot-swap replacement?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit utilizes a direct wire terminal or MIL-style connector block without internal shorting switches. Disconnecting the transmitter while the loop is powered causes the external loop current to drop to 0 mA, which initiates an open-circuit fault alarm at the receiving DCS\/PLC card.\u003c\/p\u003e\n\u003cp\u003eQ: How does a mechanical housing grounding fault alter the loop measurement?\u003c\/p\u003e\n\u003cp\u003eA: If the transmitter body or shield braid makes an unisolated connection to a secondary ground potential, ground loops form. This introduces common-mode electrical noise that distorts the 4-20 mA current output, causing fluctuating offsets in the logged vibration velocity.\u003c\/p\u003e\n\u003cp\u003eQ: What fault state signal is produced if the internal piezoelectric sensor fails?\u003c\/p\u003e\n\u003cp\u003eA: Internal element degradation or transducer circuit failure drives the transmitter output current below the lower measurement threshold to a clamping state under 3.6 mA, triggering a sensor fault alert at the host system.\u003c\/p\u003e\n\u003ch3\u003eField Layout Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Face Engagement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrepare a flat, perpendicular mounting spot on the machine case. Clean all debris from the surface and tighten the M8 x 1.25 stud to a torque value of 11.3 N-m to verify linear high-frequency mechanical transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate the outer braided cable shield at a single point, preferably at the receiving instrument rack ground rail. Fully isolate the shield wire at the transmitter terminal box using heat-shrink tubing to prevent unexpected ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEncase the interconnecting loop wiring inside grounded steel conduits. Avoid routing these signal wires in parallel alignment alongside high-voltage motor power leads or VFD lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcurement Package Content\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 177230-01-01-05 Seismic Transmitter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x M8 x 1.25 Hexagonal Mounting Stud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical Calibration Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransport and Packing Protocols\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish validation is confirmed by the system interface. Hardware shipments deploy from the warehouse node via global logistics networks including DHL, FEDEX, or UPS. All units are shipped inside anti-static industrial packaging materials and packed into double-walled shock-absorbent boxes to eliminate the risk of mechanical calibration shifts during transit.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823522477,"sku":"177230-01-01-05","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-177230-01-01-05-transmitter-oqpchyqzyhm.jpg?v=1766979627"},{"product_id":"330400-01-00-bently-nevada-3300-series-accelerometer-sensor","title":"330400-01-00 Bently Nevada 3300 Series Accelerometer Sensor","description":"\u003cp\u003eConfigured for high-frequency vibration measurement in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330400-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccelerometer Sensor) provides direct physical\/electrical execution. The hardware translates mechanical surface acceleration along its primary axis into a proportional electrical charge signal, which is processed into a voltage output via internal charge amplifier electronics for delivery to monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330400\u003c\/strong\u003e: Base model for the 3300 XL Accelerometer Sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Mounting thread option designating 1\/4-28 UNF standard stud.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency approval option specifying no hazardous area certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330400-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2 mV\/m\/s^2 (100 mV\/g) +\/-5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAcceleration Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e490 m\/s^2 (50 g) peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz to 15 kHz (+\/-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResonant Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 30 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55 deg C to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal constant current source required (2 mA to 10 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mm x 150 mm x 100 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Rotor Casing Vibration Tracking\u003c\/h3\u003e\n\u003cp\u003eThe physical deployment of the 330400-01-00 sensor focuses on tracking structural and casing acceleration profiles linked directly to rotor dynamics. Because high-speed fluid-film bearing mechanisms can damp rotor vibrations before they fully register on external structures, this accelerometer features a high resonant frequency (\u0026gt;30 kHz) designed to suppress mechanical cross-talk and avoid signal saturation. This ensures clear detection of high-frequency blade passing frequencies and rolling element bearing faults without interference from the underlying low-frequency rotor rotational speeds.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Bently Nevada 330400-01-00 piezoelectric accelerometer unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 1\/4-28 to 1\/4-28 mounting stud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo (2) Calibration record sheets documenting standard frequency response and sensitivity verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting and Interface Integrity Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the mounting surface is machined flat to 0.025 mm over the contact zone to guarantee seamless mechanical coupling and prevent high-frequency attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a thin film of silicone grease or oil interface lubricant to the machined surface before applying the final mounting torque.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque the sensor housing down to a range of 3.4 N-m to 4.5 N-m using a calibrated torque wrench; exceeding this range risk permanent internal crystal deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the cable shield exclusively at the monitoring rack end; ensure the field sensor end remains floating within its isolated terminal housing to bypass potential ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure field cabling within 150 mm of the sensor head using structural tie-downs to eliminate cable slap and minimize triboelectric noise induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProcurement Logistics \u0026amp; Shipping Configuration\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish via premium priority global air freight networks including DHL, FEDEX, or UPS. Heavy-gauge static-dissipative material forms the inner boundary of the anti-static industrial packaging matrix, shielding the integral charge conversion electronics from atmospheric electro-static discharge during terminal handling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can this sensor be powered directly via standard 24 VDC industrial power supplies?\u003c\/p\u003e\n\u003cp\u003eA: No, the internal electronics require a continuous constant current supply source ranging between 2 mA and 10 mA. Connecting a standard voltage source directly without current regulation will result in component failure or non-linear signal responses.\u003c\/p\u003e\n\u003cp\u003eQ: Is this specific dash variant (-00) permissible for install inside Class I Division 1 environments?\u003c\/p\u003e\n\u003cp\u003eA: No, the -00 option designates zero hazardous area certifications. For installation inside restricted intrinsic safety or explosion-proof boundaries, an approved prefix option such as the -05 multiple approval option must be specified.\u003c\/p\u003e\n\u003cp\u003eQ: Does internal capacitance change due to long cable lengths alter the sensor's baseline scale factor?\u003c\/p\u003e\n\u003cp\u003eA: The onboard charge amplifier architecture minimizes the impact of cable capacitance on overall sensitivity. However, extreme cable runs (exceeding 300 m) can cause high-frequency roll-off effects depending on the monitoring monitor's source drive limits.\u003c\/p\u003e\n\u003cp\u003eQ: Can this device withstand continuous exposure to oil vapor and moisture?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the exterior housing is fabricated from 316L stainless steel and hermetically sealed to withstand continuous exposure to typical industrial lubricants and synthetic machine fluids, provided the cable connector boot is sealed correctly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518824571053,"sku":"330400-01-00","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330400-01-00-accelerometers-i224l2td2r4.jpg?v=1766979635"},{"product_id":"330881-28-04-070-03-02-bently-nevada-proxpac-xl-series-proximity-transducer","title":"330881-28-04-070-03-02 Bently Nevada PROXPAC XL Series Proximity Transducer","description":"\u003cp\u003eConfigured for non-contacting shaft displacement and dynamic vibration tracking in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-04-070-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical\/electrical execution. The instrument integrates an 8 mm eddy-current probe, extension cable, and Proximitor sensor inside a single robust, weather-resistant housing assembly to generate high-frequency analog signals proportional to static and dynamic distance parameters.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Evaluation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: PROXPAC XL Proximity Transducer Assembly with 8 mm sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-28\u003c\/strong\u003e: 3\/4-14 NPT conduit fitting, glass-reinforced epoxy housing material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-04\u003c\/strong\u003e: Probe case thread option designating 3\/8-24 UNF.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-070\u003c\/strong\u003e: Total unthreaded case length option designating 7.0 in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03\u003c\/strong\u003e: Total system length option designating 5.0 m (16.4 ft) with DIN rail mounting criteria.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Agency approval option specifying ATEX\/IECEx intrinsically safe and zone 2 non-incendive parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Performance Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-04-070-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal starting at 0.25 mm (10 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Total Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 m matched network\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Housing Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT conduit entry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Case Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C (Housing and electronics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInput voltage range -18 VDC to -24 VDC at 12 mA maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e310 mm x 280 mm x 150 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Validation\u003c\/h3\u003e\n\u003cp\u003eThe internal Proximitor assembly regulates the high-frequency RF output to drive the 8 mm sensor face, establishing a precise eddy-current probe scaling format. Field commissioning requires a gap voltage validation target of -10 VDC (+\/-0.5 VDC) representing the midpoint of the linear calibration envelope. This continuous electrical reference isolates rotor dynamics deviations without mechanical contact while internal shielding profiles maintain cross-talk suppression below noise floor thresholds when identical housings share a common support structure.\u003c\/p\u003e\n\u003ch3\u003eComponent Consignment Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Integrated Bently Nevada 330881 PROXPAC XL transducer assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Pre-installed 8 mm proximity probe with internal 5.0 m matched cabling architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo (2) internal mounting brackets for mechanical adjustment stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Silicone weatherproof sealing gasket layer for outer housing interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation and Cabling Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the primary glass-reinforced epoxy housing onto the machine casing using rigid support frames to prevent structural resonance from overriding true target vibration profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the internal 3\/8-24 UNF probe position while monitoring electrical potential with a digital multimeter until the output tracks the designated -10 VDC gap validation coordinate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure all external 3\/4-14 NPT conduit fittings to standard depth profiles to maintain the IP66 ingress protection rating against environmental fluid exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the output signal cabled loops using insulated twisted-pair shielded wire formations, grounding the shield terminal solely at the monitored TSI rack interface block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate parallel external sensor lines by a minimum spacing threshold of 40 mm to prevent electromagnetic cross-talk interference from distorting high-frequency dynamic outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Framework \u0026amp; Cargo Handling\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, routed via expedited air transport networks utilizing DHL, FEDEX, or UPS. Inner parts reside within sealed vapor-barrier anti-static industrial packaging enclosures. The outer cargo box features thick dual-wall cardboard framing coupled with custom shock-absorbent structural foam matrices to prevent any physical displacement of the internal electronics or probe tip calibration during multi-point transit loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can the internal Proximitor module within this 5.0 m transducer assembly be serviced or replaced with a standard 9.0 m standalone Proximitor unit?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal electronics match the specific 5.0 m total physical length calibration of the integrated probe and cable array. Swapping modules with a 9.0 m derivative violates the calibrated eddy-current probe scaling, inducing measurement errors across the linear span.\u003c\/p\u003e\n\u003cp\u003eQ: How must the internal shield layer of the terminal block signal cable be handled inside the PROXPAC housing?\u003c\/p\u003e\n\u003cp\u003eA: The shield must remain completely isolated and ungrounded inside the PROXPAC enclosure. Floating this shield connection inside the transmitter housing prevents the formation of ground loop currents that distort shaft vibration measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What action occurs if the target gap moves beyond the maximum 2.0 mm linear threshold?\u003c\/p\u003e\n\u003cp\u003eA: The output voltage shifts flat toward the supply saturation limit (approximately -21 VDC). The connected monitoring framework registers an \"Out of Limit\" or \"Not OK\" physical fault state, which automatically inhibits false measurement data entry.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518824964269,"sku":"330881-28-04-070-03-02","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-04-070-03-02-proxpac-xl-proximity-transducer-jd2buxicihh.jpg?v=1766979649"},{"product_id":"190501-01-00-01-bently-nevada-velomitor-ct-series-velocity-transducer","title":"190501-01-00-01 Bently Nevada Velomitor CT Series Velocity Transducer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 190501-01-00-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e190501\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVelocity Transducer, operates as a dedicated hardware component for casing vibration measurement within machinery protection and condition monitoring networks. The hardware integrates an internal solid-state accelerometer and an electronic integration circuit to translate physical casing acceleration into a proportional analog voltage output proportional to absolute velocity.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e190501\u003c\/strong\u003e: Velomitor CT (Cooling Tower) Velocity Transducer base model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Mounting thread option designating 1\/2-20 UNF standard stud.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency approval option specifying no hazardous area certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Connection option designating a 2-pin MIL-C-5015 top-exit integral receptacle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e190501-01-00-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 mV\/mm\/s (100 mV\/in\/s) +\/-10%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Hz to 1.0 kHz (+\/-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVelocity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 mm\/s (5.0 in\/s) peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePin Electrical Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePin A: Power\/Signal, Pin B: Common\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA to 10 mA constant current supply (24 VDC nominal loop voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 mm x 110 mm x 90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cooling Tower Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe architectural design of the 190501-01-00-01 transducer focuses on suppressing low-frequency aerodynamic noise and mechanical cross-talk associated with cooling tower fan structures. By evaluating housing velocity parameters directly rather than relying on eddy-current probe scaling or gap voltage validation (-10 VDC targets), this device senses structural imbalances linked to overall rotor dynamics. Internal filtering rejection profiles optimize tracking for low-speed machinery fault profiles while bypassing the baseline signal anomalies caused by high-frequency blade-passing vibrations.\u003c\/p\u003e\n\u003ch3\u003eInventory Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Bently Nevada 190501-01-00-01 Velomitor CT transducer unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 1\/2-20 UNF hex mounting stud\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo (2) Standard lock washers for vibration locking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Printed factory calibration response sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachine the physical mating area flat to a 0.03 mm finish across a minimum 30 mm diameter footprint to guarantee unattenuated mechanical signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a thin interface layer of high-temperature grease or oil compound to the target surface prior to setting the sensor positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque the transducer hex flats to a specific limitation of 9.0 N-m to 13.5 N-m using a calibrated torque wrench; exceeding this parameter creates internal structural stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the 2-pin MIL cable assembly securely, insulating the connector coupling with a weatherproof boot to prevent moisture or fluid ingress from shorting out the contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the field signal run inside rigid conduit lines, maintaining a single-point shield termination ground at the monitoring module rack side only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipment Logistics \u0026amp; Packaging Standard\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, routed via specialized express cargo channels handled by DHL, FEDEX, or UPS. The units are sealed within industrial-grade barrier films inside anti-static industrial packaging to maintain component integrity. Dual-wall exterior shipping packaging features form-fitting foam padding structures to secure internal electronics from drop shocks or transit forces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this transducer be connected directly to standard PLC analog voltage input modules?\u003c\/p\u003e\n\u003cp\u003eA: No, the transducer operates as a constant current loop device requiring a dedicated monitor supply interface or an external constant current source (2 mA to 10 mA). Connecting it straight to a generic passive voltage input without current limiting will damage the internal circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: How does this device differ from a standard Velomitor sensor?\u003c\/p\u003e\n\u003cp\u003eA: The Velomitor CT (Cooling Tower) variant is specially tuned with lower frequency response metrics (down to 1.5 Hz) and enhanced internal dampening attributes designed for low-speed rotating machinery machinery architectures.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping this device safe while the monitored rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, field technicians can disconnect or replace the 2-pin MIL connector loop while the monitoring system is fully active without causing damage to the sensor or introducing voltage surges into the instrumentation rack bus.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518825029805,"sku":"190501-01-00-01","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-190501-01-00-01-velomitor-ct-transducer-tu1whjy4px2.jpg?v=1766979650"},{"product_id":"330881-16-08-095-06-02-bently-nevada-proxpac-xl-series-proximity-transducer","title":"330881-16-08-095-06-02 Bently Nevada PROXPAC XL Series Proximity Transducer","description":"\u003cp\u003eConfigured for non-contacting shaft displacement and dynamic vibration tracking in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-16-08-095-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical\/electrical execution. The instrument houses an 8 mm eddy-current probe sensing tip, an extension cable segment, and an integrated Proximitor sensor board within a single structural containment unit to output continuous analog voltage curves proportional to the shaft target gap.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: PROXPAC XL Proximity Transducer assembly base model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-16\u003c\/strong\u003e: 3\/4-14 NPT conduit fittings, polyphenylene sulfide (PPS) housing material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-08\u003c\/strong\u003e: Probe case thread option designating 3\/8-24 UNF threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-095\u003c\/strong\u003e: Total unthreaded case length option designating 9.5 in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-06\u003c\/strong\u003e: Total system length option designating 9.0 m (29.5 ft) with DIN rail mounting parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Agency approval option specifying ATEX\/IECEx intrinsically safe and zone 2 non-incendive operation metrics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-16-08-095-06-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal starting at 0.25 mm (10 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Total Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 m calibrated internal matching\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Housing Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 3\/4-14 NPT conduit entries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Case Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C (Housing environment limits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupply voltage range -18 VDC to -24 VDC at 12 mA maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e340 mm x 290 mm x 170 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Analysis\u003c\/h3\u003e\n\u003cp\u003eThe internal circuit module converts high-frequency RF excitations from the 8 mm tip into a continuous voltage matrix, establishing a defined eddy-current probe scaling metric. Operational validation requires setting the target positioning to yield a gap voltage validation target of -10 VDC, matching the midpoint of the 2.0 mm linear tracking span. This baseline parameters are required to isolate true shaft fluctuations during critical rotor dynamics events while built-in isolation configurations preserve cross-talk suppression under multi-housing array environments.\u003c\/p\u003e\n\u003ch3\u003eConsignment Itemization List\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Integrated Bently Nevada 330881 PROXPAC XL transducer assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Pre-installed 8 mm proximity probe with internal 9.0 m calibrated cable connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo (2) Internal lock plates for mechanical sleeve securement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Specialized silicone environmental casing seal profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation and Cabling Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the exterior PPS housing base structure onto a flat machined structural surface using rigid adapter blocks to prevent local structural resonance from biasing the internal sensor measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the physical depth of the 3\/8-24 UNF probe body while reading output parameters via an external digital voltmeter until the loop registers the standard -10 VDC gap validation coordinate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure all external 3\/4-14 NPT conduit interfaces with standard thread sealants to verify a complete environmental boundary seal against industrial moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the outgoing signal lines via twisted-pair shielded instrumentation cables, verifying that the copper shield line connects to ground exclusively at the TSI monitoring rack terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure adjacent proximity probe housings are separated by a minimum physical distance of 40 mm to guarantee sufficient cross-talk suppression between neighboring magnetic loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging Framework \u0026amp; Transit Management\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish, handled via priority air freight carriers DHL, FEDEX, or UPS. Inner modules are preserved in heavy-duty vapor-tight anti-static industrial packaging. The outermost container is constructed from dense double-wall industrial fiberboard lined with custom-molded high-density foam cells to eliminate physical component migration or calibration shift under transit shock loads.\u003c\/p\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can the internal Proximitor sensor component inside this 9.0 m housing be used with a standalone 5.0 m probe assembly?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal electronic sub-assembly is tuned explicitly to the total 9.0 m physical and electrical path of the built-in sensor. Forcing a mismatched length compromises the eddy-current probe scaling, inducing non-linear tracking errors across the target range.\u003c\/p\u003e\n\u003cp\u003eQ: How is a target gap movement beyond the specified 2.0 mm linear range flagged by the sensor hardware?\u003c\/p\u003e\n\u003cp\u003eA: When the gap distance extends beyond the calibration boundary, the output drops flat towards the supply saturation limit (approx. -21 VDC). The remote tracking rack flags this specific potential as a \"Not OK\" signal fault condition.\u003c\/p\u003e\n\u003cp\u003eQ: Does servicing the signal line connections within the enclosure housing require powering down the complete instrument rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The signal loops can be accessed or rewired while the main tracking rack is active, as the circuit handles hot-swap steps without causing electrical damage to the driver cards or the passive sensor components.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518825128109,"sku":"330881-16-08-095-06-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-16-08-095-06-02-proxpac-xl-proximity-transducer-0eeq4b0xswr.jpg?v=1766979654"},{"product_id":"330881-28-10-060-03-02-bently-nevada-proxpac-xl-series-proximity-transducer","title":"330881-28-10-060-03-02 Bently Nevada PROXPAC XL Series Proximity Transducer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-10-060-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a dedicated hardware component for non-contacting shaft displacement and dynamic vibration monitoring within machinery protection systems. The integrated assembly combines an 8 mm eddy-current proximity probe, extension cable, and Proximitor sensor inside a single environmental housing, converting physical target distances into linearized voltage parameters readable by external machinery protection monitors.\u003c\/p\u003e\n\u003ch3\u003eModel Option Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: PROXPAC XL Proximity Transducer assembly with integrated 3300 XL 8 mm sensor electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-28\u003c\/strong\u003e: Probe threaded length option designating 2.8 in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-10\u003c\/strong\u003e: Probe total length option designating 1.0 m (3.3 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-060\u003c\/strong\u003e: Stilling well length option designating 6.0 in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03\u003c\/strong\u003e: Thread type option specifying 1\/2-14 NPT process and conduit entries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Agency approval option specifying ATEX, IECEx, and North American hazardous zone certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-10-060-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) total displacement span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-copper epoxy-coated aluminum enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConduit Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/2-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C (Probe tip); -35 deg C to +85 deg C (Enclosed electronics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 W maximum current extraction loop\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e340 mm x 210 mm x 190 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Optimization\u003c\/h3\u003e\n\u003cp\u003eThe self-contained housing structure governs the internal spatial positioning and physical boundary orientation of the inductive tip relative to the moving shaft. Correct installation mechanics require verifying a gap voltage validation target (-10 VDC targets) across the internal BNC terminal junctions prior to operational lock-down. Precision setting preserves the nominal 200 mV\/mil eddy-current probe scaling accuracy under severe temperature fluctuations, mitigating thermal measurement drift during complex rotor dynamics cycles and guaranteeing cross-talk suppression between closely grouped radial sensor pairs.\u003c\/p\u003e\n\u003ch3\u003ePackaging Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Bently Nevada 330881-28-10-060-03-02 PROXPAC XL transducer assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Pre-installed internal 3300 XL sensor module core\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo (2) High-durability terminal block terminal block jumpers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration certification validation charts containing factory linearity signatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the primary 1\/2-14 NPT housing body base into the machine casing thread, utilizing a minimum of 5 full NPT thread engagements to ensure structural sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the power supply and analog feedback lines through certified explosion-proof rigid conduit pipes or armored gland accessories coupled to the conduit entry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the integrated probe barrel depth using external screw threads while tracking real-time voltage response values with a digital voltmeter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate adjustment procedures immediately upon reaching the designated -10 VDC gap voltage validation center point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque down the housing lock nuts to 13.5 N-m to freeze sensor movement and seal the primary enclosure cap to isolate internal electronics from atmospheric moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Parameters \u0026amp; Shipping Specification\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish, routed via expedited international courier channels utilizing DHL, FEDEX, or UPS. The primary transducer instruments are wrapped inside multi-layer moisture-barrier anti-static industrial packaging boundaries. Master packing containers feature reinforced double-wall cardboard sheets integrated with custom high-density molded polyurethane foam blocks to insulate factory calibration metrics against severe kinetic shock during transit paths.\u003c\/p\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does this PROXPAC XL assembly support field modification of the internal probe or cable lengths?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal integration matrix relies on a factory-tuned impedance loop matching the 1.0 m total length probe option. Modifying cable loops or altering lengths disrupts the factory calibration, corrupts the eddy-current probe scaling, and prevents correct gap voltage validation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the shield layer managed inside this single-enclosure sensor layout?\u003c\/p\u003e\n\u003cp\u003eA: The transducer electronics shield must remain isolated from the local housing chassis and the machinery frame. The field cable shield line must pass cleanly through the enclosure without local ground contact, terminating exclusively at the main monitoring rack instrumentation ground point.\u003c\/p\u003e\n\u003cp\u003eQ: What internal electrical output behavior occurs if the sensor tip suffers physical damage from a loose mechanical element?\u003c\/p\u003e\n\u003cp\u003eA: Physical deformation or destruction of the inductive tip coil forces the internal Proximitor driver circuit into voltage saturation, pushing the output terminal to approximately -21 VDC. The connected TSI monitor flags this extreme level as a \"Not OK\" fault status condition.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518825488557,"sku":"330881-28-10-060-03-02","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-10-060-03-02-proxpac-xl-proximity-transducer-0pgoa0thxti.jpg?v=1766979665"},{"product_id":"106765-10-interconnect-cable-for-vibration-monitoring-bently-nevada","title":"106765-10 Interconnect Cable for Vibration Monitoring – Bently Nevada","description":"\u003ch3 class=\"\"\u003e106765-10 Interconnect Cable for Vibration Monitoring – Bently Nevada\u003c\/h3\u003e\n\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-1560 citation-end-1560\"\u003eThe Bently Nevada 106765-10 is a high-integrity interconnect cable engineered to facilitate seamless signal transmission within industrial machinery protection systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-1559 citation-end-1559\"\u003eThis cable is specifically designed to bridge the gap between vibration transducers and monitoring modules, ensuring that critical 4-20mA signals and seismic data remain accurate and uninterrupted.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-1558 citation-end-1558\"\u003eBy utilizing a shielded twisted-pair configuration, the 106765-10 effectively suppresses electromagnetic interference (EMI) and radio frequency interference (RFI), which are common in dense industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis connection cable is a fundamental component of Turbine Supervisory Instrumentation (TSI),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting continuous machinery health monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts electrical properties are optimized for 18-30VDC power distribution and signal return,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eminimizing voltage drop across the cable run to maintain the precision of predictive maintenance data.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Characteristics and Construction\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 106765-10 is built to sustain long-term performance under the rigorous mechanical and chemical stresses of power plants and refineries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEMI\/RFI Shielding:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a robust internal shield that isolates the signal from external noise,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing data corruption in high-voltage areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan class=\"citation-1557 citation-end-1557\"\u003e\u003cspan\u003e \u003c\/span\u003eConstructed with advanced insulation options, such as Polyurethane or Teflon, to provide superior resistance against chemical exposure, oil splashes, and moisture ingress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePrecision Conductor Sizing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBalanced gauge wiring ensures efficient power delivery to sensors while maintaining high-fidelity transmission of vibration waveforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eGlobal Compliance:\u003c\/strong\u003e\u003cspan class=\"citation-1556 citation-end-1556\"\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in ISO 9001 certified facilities and meeting CE and UL standards, guaranteeing safety and reliability across international industrial operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-1555 animating\"\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003eFlexible Implementation:\u003c\/strong\u003e\u003cspan class=\"citation-1555 citation-end-1555\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for durability, the cable remains pliable enough for complex routing through conduits and cable trays without compromising internal conductor integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Designation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e106765-10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eComponent Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eShielded Interconnect Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e18 - 30 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Support:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4-20mA \/ Dynamic Vibration Signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConstruction:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eShielded Twisted Pair\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInsulation Material:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-grade Polyurethane\/Teflon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNet Weight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e9 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eShipping Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e28 cm x 28 cm x 4 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCertification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCE,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUL,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eISO 9001\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 106765-10 connection cable is widely utilized to safeguard high-capital rotating assets where signal reliability is non-negotiable.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts primary applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eInterfacing Velomitor and seismic transducers with monitoring racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eConnecting field-mounted vibration transmitters to central DCS or PLCs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eCritical monitoring in oil and gas extraction and refinery processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003ePower generation turbine and generator health tracking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518825652397,"sku":"106765-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-106765-10-interconnect-cable-r0aklnzhqvt.jpg?v=1766979674"},{"product_id":"bently-nevada-330400-01-cn-330400-series-accelerometer","title":"Bently Nevada 330400-01-CN 330400 Series Accelerometer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330400-01-CN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccelerometer, operates as a dedicated hardware component for high-frequency vibration and casing acceleration measurements within Trendmaster platforms. The piezoelectric sensor element inside the hermetically sealed casing converts raw dynamic mechanical acceleration forces directly into a linearized, charge-amplified analog voltage parameter readable by downstream machinery protection monitors.\u003c\/p\u003e\n\u003ch3\u003eOption Matrix and Suffix Code Meanings\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330400\u003c\/strong\u003e: Trendmaster Accelerometer base model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Mounting thread option specifying a 1\/4-28 UNF stud fitting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e: Agency approval option designating standard safety and environmental compliance certifications for the Chinese industrial market.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330400-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2 mV\/m\/s2 (100 mV\/g) ±5% nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Hz to 10,000 Hz ±3 dB deviation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmplitude Linearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePeak limit to 490 m\/s2 (50 g) acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBias Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 VDC nominal relative to COM terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResonance Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 30 kHz mounted baseline\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-pin hermetic top-exit MIL-C-5015 connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-54 deg C to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC excitation input, 2 mA to 10 mA constant loop current\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 mm x 140 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics Integration and Gap Voltage Validation Comparison\u003c\/h3\u003e\n\u003cp\u003eUnlike proximity tracking systems that focus strictly on low-frequency shaft relative tracking via eddy-current probe scaling configurations, the 330400-01-CN captures casing absolute high-frequency vibration profiles. However, it interfaces with the same structural logic where raw signal validation matches a predefined bias output voltage (-10 VDC targets). Monitoring this DC bias baseline enables continuous diagnostic confirmation of the internal crystal impedance, isolating genuine high-frequency casing structural events from sensor breakdown caused by transient rotor dynamics shocks or cross-talk suppression failures on nearby channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) Bently Nevada 330400-01-CN accelerometer sensing assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 1\/4-28 UNF to 1\/4-28 UNF standard mounting stud link\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-noise silicone interface mating gasket set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory calibration sheet recording individual verification data profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrepare the target casing surface to a flatness profile better than 0.03 mm, ensuring it is clear of grease, scale, or pitting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBore and tap the structural housing to match the chosen 1\/4-2stud depth specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a micro-layer of high-vacuum silicone grease to the structural interface base to optimize high-frequency kinetic transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque the accelerometer housing down using a calibrated wrench to a final mechanical force of 4.5 N-m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the outer shield line of the 3-conductor MIL-C-5015 field cable to the primary instrument rack chassis ground, maintaining isolation at the transducer casing block to eliminate disruptive ground loop potentials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish through expedited international air networks managed by DHL, FEDEX, or UPS. The precision piezoelectric devices are packed inside sealed vapor-barrier anti-static industrial packaging boundaries to prevent contamination of the 3-pin MIL gold contacts. Master transit boxes use high-density cross-linked polyethylene shock pads to isolate the factory calibrated internal crystal alignment from transport vibration loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this specific accelerometer function with a standard 3500\/42M monitor module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 330400-01-CN produces a standard 100 mV\/g scale factor with a -10 VDC nominal bias line. The 3500\/42M module must be configured via software options to read an acceleration input with these specific electrical values.\u003c\/p\u003e\n\u003cp\u003eQ: What structural failure indication occurs if the internal piezoelectric crystal is cracked by impact?\u003c\/p\u003e\n\u003cp\u003eA: A broken crystal or damaged internal charge amplifier causes the nominal -10 VDC bias output voltage to drift outside its standard operating window. The connected monitor identifies this voltage change and flags a sensor fault, disabling downstream safety trip loops.\u003c\/p\u003e\n\u003cp\u003eQ: Is this accelerometer insulated from ground potentials at its base structure?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal circuit common of the sensor is isolated from the outer housing shell, but the stainless steel enclosure is electrically bonded to the mounting stud base. Ground loops must be avoided by grounding the cable shield exclusively at the monitoring system chassis.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518825783469,"sku":"330400-01-CN","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330400-01-cn-accelerometer-acceleration-transducers-rfuxpbivajf.jpg?v=1766979679"},{"product_id":"330881-28-11-265-00-02-bently-nevada-proxpac-xl-proximity-probes","title":"330881-28-11-265-00-02 Bently Nevada PROXPAC XL Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-11-265-00-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer, operates as a dedicated hardware component for continuous shaft radial vibration and axial position monitoring within PROXPAC XL Transducer System platforms. Configured for high-reliability sensing in turbomachinery, this integrated probe provides direct physical and electrical execution of eddy-current signal sensing. It converts the distance between the probe tip and the conductive target into a voltage signal proportional to the gap, facilitating rotor dynamics analysis and machine protection without signal attenuation in challenging industrial environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-11-265-00-02 assembly is defined by the following technical configuration parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e28: Probe mount and configuration style\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11: Case length (110 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e265: Total length (26.5 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Connector interface specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Agency certification and calibration grouping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-11-265-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 x 35 x 20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop powered via integrated circuitry)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL transducer system utilizes precise eddy-current probe scaling to ensure linear output relative to shaft distance. During system commissioning, gap voltage validation is mandatory; installers must target -10 VDC when the probe is positioned at the midpoint of its linear range. Rotor dynamics analysis depends on this precise gap setting to accurately capture radial vibration vectors and shaft centerline movement. Signal integrity is maintained through calibrated impedance matching within the integrated Proximitor circuitry, effectively suppressing cross-talk interference in multi-channel monitoring arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881 PROXPAC XL Proximity Transducer assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector thread caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct documentation and installation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Mounting adapters and junction boxes are required for field completion and must be ordered according to machine casing geometry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Utilize a calibrated feeler gauge or depth micrometer to establish the probe gap; confirm the Proximitor output reaches -10 VDC at the monitor terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque Constraints: Secure the probe locknut using the specified torque to prevent vibration-induced loosening; avoid over-tightening which can deform the stainless steel case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Routing: Install the integral coaxial cable within dedicated grounded metallic conduit to provide shielding against electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain electrical continuity between the probe housing and the machine chassis to ensure a stable reference voltage and minimize ground-loop noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSurface Integrity: Ensure the target shaft area is free of non-conductive coatings, machining burrs, or debris to prevent signal instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the 330881 probe be used with legacy 3300 series Proximitors?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the PROXPAC XL utilizes integrated Proximitor electronics and is not compatible with external 3300 or 3300 XL Proximitor modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 26.5 meter length field-adjustable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the cable length is an integral part of the tuned system impedance; modification will cause signal non-linearity and calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary cause of probe output drift?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Drift is commonly caused by thermal expansion of the housing, loose locknuts, or cable damage due to kinking or abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the PPS probe tip suitable for oil immersion?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the Polyphenylene Sulfide (PPS) tip is chemically inert and designed to withstand continuous exposure to hydraulic and lubricating oils.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How often should I perform a dynamic calibration check?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Verify gap voltage at every scheduled shutdown; dynamic calibration using a shaker table is recommended only after transducer repair or replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What does the '02' suffix indicate for agency approvals?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The '02' suffix signifies specific compliance with hazardous area regulations; verify the label for relevant ATEX\/CSA\/IECEx markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this probe on non-ferrous shafts?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Eddy-current systems are calibrated for 4140 steel; non-ferrous targets change the magnetic coupling and require a customized scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is an integrated design used?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The integrated design reduces the number of connections in the transducer loop, minimizing signal reflection and preventing moisture ingress at connection points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518825947309,"sku":"330881-28-11-265-00-02","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-11-265-00-02-proxpac-xl-proximity-transducer-kd4yhrgd243.jpg?v=1766979686"},{"product_id":"bently-nevada-330881-28-15-122-03-02-proximity-probes-proxpac-xl","title":"Bently Nevada 330881-28-15-122-03-02 Proximity Probes PROXPAC XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330881-28-15-122-03-02 is an advanced PROXPAC XL proximity transducer system designed for demanding industrial machinery protection environments. By integrating the Proximitor sensor functionality directly into the probe assembly housing, this unit eliminates the traditional requirement for separate extension cables and remote Proximitor mounting, thereby reducing wiring complexity and potential signal degradation points. Utilizing eddy-current technology, the 330881 provides continuous, high-fidelity monitoring of rotor radial vibration and axial position. This integrated design is specifically engineered for critical turbomachinery applications where space-constrained installations require a robust, single-piece transducer solution that maintains extreme accuracy during high-temperature and high-vibration operational cycles.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-15-122-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 x 30 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 VDC \/ 200 mV\/mil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHazardous Area Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-15-122-03-02 represents a highly specialized configuration within the PROXPAC XL product line:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e28: Probe mount and configuration style\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e15: Case length (150 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e122: Cable length (12.2 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e03: Connector interface specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Agency certification and calibration grouping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe integrated nature of the PROXPAC XL makes it ideal for specific challenging industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSkid-Mounted Machinery: Reducing cabling footprint in complex, densely packed compressor or pump skids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote Monitoring Sites: Minimizing the distance between the signal source and the local junction box to improve signal-to-noise ratios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarsh Environmental Enclosures: Reducing the number of potential moisture or dust entry points by eliminating exposed cable connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit Projects: Replacing legacy systems where available space for separate Proximitor sensors is insufficient or non-existent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Density Protection Arrays: Simplifying large-scale monitoring installations where thousands of channels require streamlined physical management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-15-122-03-02 is designed for compatibility with the Bently Nevada 3500 Machinery Protection System. Because the Proximitor circuitry is integrated, the system requires a stable, filtered -24 VDC power supply. Users must verify that the monitoring rack input cards are specifically calibrated for PROXPAC XL characteristics. This unit is not interchangeable with standard two-piece 3300 XL transducer systems, as the internal signal conditioning is permanently paired with the probe coil impedance.\u003c\/p\u003e\n\u003ch3\u003eInstallation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGap Verification: Use a calibrated depth micrometer to ensure the probe tip is set to the manufacturer-recommended air gap. Aim for the -10 VDC center-point to ensure optimal dynamic range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque Application: Utilize a torque-limiting wrench on the stainless steel locknuts. Excessive torque may induce stress on the housing, potentially affecting the integrity of the integrated electronic module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Management: Run the integral coaxial cable through rigid, grounded metallic conduit. Grounding the conduit at both ends is necessary to minimize common-mode electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Sealing: Ensure the connector interface is protected from oil, moisture, and chemical vapor ingress, which can compromise the signal path integrity over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Strategy: Establish a clean instrument ground separate from the high-power chassis ground to avoid 50\/60 Hz ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReduced Signal Path Length: The integrated design significantly lowers the likelihood of signal attenuation and external interference by removing the extension cable interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimplified Maintenance: With fewer components to manage, troubleshooting becomes significantly faster, as the entire transducer can be tested as a single entity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact Footprint: Ideal for modern, high-density machine designs where mounting a remote Proximitor is physically prohibited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory Calibration: Each PROXPAC XL unit is calibrated as a complete system, ensuring maximum measurement accuracy without the risk of impedance mismatches between components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881-28-15-122-03-02 Integrated Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation hardware kit (Locknuts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical manual and calibration report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Verify that your power supply distribution can handle the continuous current draw of an integrated transducer system across all installed channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this unit be hot-swapped while the machine is running?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, removing a transducer from a running machine will result in a loss of signal and likely trigger an alarm or trip in your protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the cable length significantly longer (12.2 m)?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The integrated design accounts for fixed-length transmission. Ensure that 12.2 meters is sufficient for your cable run before final mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does it compare to the two-piece 3300 XL system?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The PROXPAC XL eliminates the connector between the probe and extension cable, reducing potential points of failure and simplifying physical installation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this with an older 3300 monitor?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Compatibility depends on the input card's ability to provide the correct excitation voltage and process the specific output sensitivity of the PROXPAC XL.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the stainless steel housing corrosion-resistant?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the AISI 303 stainless steel is highly resistant to standard industrial lubricants and atmospheric corrosion common in power generation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates that the integrated electronics have failed?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: A complete loss of output or a fixed-voltage output regardless of the gap movement usually indicates an internal component failure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is calibration verified?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Verification is performed by measuring the output voltage at various gap distances using a calibration kit (shaker table or micrometer kit).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this require special mounting adapters?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, ensure you order the appropriate mounting bracket that matches the 150 mm case length and 8 mm probe diameter.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the unit be repaired?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Due to the integrated, potted electronics, these units are considered \"non-repairable\" and should be replaced if internal components fail.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 12.2-meter cable length custom?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The length is a standard option provided during the ordering process to accommodate various distances from machine to junction box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518826209453,"sku":"330881-28-15-122-03-02","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-15-122-03-02-proxpac-xl-proximity-transducer-mnesif4t0vv.jpg?v=1766979694"},{"product_id":"330500-01-00-bently-nevada-piezo-velocity-sensor-velomitor","title":"330500-01-00 Bently Nevada Piezo-velocity Sensor Velomitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330500-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePiezo-velocity Sensor, operates as a dedicated hardware component for absolute casing vibration velocity measurement within 3500 Machinery Protection Systems or trend monitoring networks. The hardware integrates embedded piezoelectric sensing elements and internal solid-state electronics to output a low-impedance voltage signal proportional to the casing velocity.\u003c\/p\u003e\n\u003ch3\u003eSuffix Array Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Mounting Adapter Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\/2-20 UNF threaded adapter component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo regional hazardous area certifications requested\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330500-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 x 8.0 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-54 to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal loop power (via monitor interface bias)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 mV\/mm\/s (100 mV\/in\/s) nominal plus\/minus 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Hz to 5.0 kHz nominal plus\/minus 3.0 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmplitude Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 mm\/s (5.0 in\/s) peak maximum limit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Topography\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pin Mil-C-5015 hermetic top connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCasing Vibration Integration and Rotor Dynamics Context\u003c\/h3\u003e\n\u003cp\u003eWhile eddy-current probe scaling tracks relative path changes for internal shaft tracking, this piezoelectric-based transducer tracks absolute casing acceleration and mathematically integrates it into velocity targets. It maps auxiliary vibration parameters that affect lower casing supports and casing-to-rotor dynamics transfers. The architecture maintains a nominal DC bias voltage loop to verify connection state health. Internal shielding architecture minimizes external interference to guarantee optimal noise rejection and cross-talk suppression when mounted near high-amperage machine lines or adjacent casing accelerometers.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Kit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContains one (1) 330500 Velomitor piezo-velocity sensor with a 1\/2-20 UNF threaded adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation Pack:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes factory calibration verification data sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparated Spares:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnecting Mil-C-5015 2-wire shielded cables and terminal monitors are excluded and must be procured as independent line items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Dispatch Standards\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFulfillment Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipments route from warehouse tracking matrices within 2-7 days when payment finish confirmation completes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFreight Handlers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePhysical distribution executes globally via DHL, FEDEX, or UPS priority lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Guard Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComponents travel sealed inside rugged anti-static industrial packaging to maintain hermetic housing seals and prevent structural element degradation during delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Surface Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrepared casing surfaces must be machined flat to a surface finish tolerance of 0.8 micrometers Ra. Apply a light film of silicone grease or thread lubricant before mechanical torque down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Mechanical Torquing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHand-tighten the 1\/2-20 UNF stud into the casing recess, then secure the sensor housing base using a torque wrench calibrated up to 4.5 N-m (40 in-lb). Avoid excessive torque to prevent structural degradation of the internal crystal array.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the 2-pin Mil-C-5015 cable connector ensuring the internal silicone gasket seats perfectly. Tighten the collar to preserve weather-proof casing isolation. Route the shielded twisted pair cable through rigid conduit, grounding the outer shield wire exclusively at the monitor backplane to maintain cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this component undergo field adjustments to manipulate its base scale factor sensitivity?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal piezoelectric integration circuitry is fixed hermetically inside the stainless-steel casing. The nominal sensitivity is set at the factory and cannot be field modified.\u003c\/p\u003e\n\u003cp\u003eQ: How is sensor loop integrity verified when the machinery monitor lacks a gap voltage validation target?\u003c\/p\u003e\n\u003cp\u003eA: The sensor utilizes an internal DC bias voltage verification step. Under non-fault, static conditions, the signal lines maintain a steady nominal bias voltage between 10 VDC and 14 VDC. Monitor loops tracking outside this threshold indicate open or shorted field wires.\u003c\/p\u003e\n\u003cp\u003eQ: Can this sensor be deployed on a machinery housing without any mounting grease?\u003c\/p\u003e\n\u003cp\u003eA: Yes, but omitting the coupling lubricant lowers the structural high-frequency resonance limit. This reduction causes signal clipping and measurement errors when high-frequency vibration components are present on the machinery housing.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518826602669,"sku":"330500-01-00","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330500-01-00-velomitor-piezo-velocity-sensor-mmsxwrd5ljh.jpg?v=1766979713"},{"product_id":"330525-02-bently-nevada-velomitor-xa-piezo-velocity-sensors","title":"330525-02 Bently Nevada Velomitor XA Piezo-velocity Sensors","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330525-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330525\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePiezo-velocity Sensor utilized to execute absolute casing vibration velocity measurements across 3500 Machinery Protection Systems platforms. The hardware integrates internal piezoelectric crystal arrays and solid-state instrumentation amplifiers housed in a rugged enclosure to output a continuous low-impedance AC voltage signal directly proportional to structural machinery casing velocity vectors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Array Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Mounting Thread Option):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM8 x 1.25 threaded mounting stud adapter component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330525-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.5 x 8.5 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-54 to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal loop voltage (Powered via external monitor bias current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.94 mV\/mm\/s (100 mV\/in\/s) plus\/minus 5% nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 Hz to 5.0 kHz plus\/minus 3.0 dB nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Amplitude Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 mm\/s (5.0 in\/s) peak velocity threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-pin Mil-C-5015 hermetic top connector connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCasing Vibration Integration and Rotor Dynamics Context\u003c\/h3\u003e\n\u003cp\u003eWhile eddy-current probe scaling tracks relative path variations for internal shaft monitoring, this piezoelectric hardware measures absolute structural acceleration and integrates it internally into velocity targets. It tracks parameters linked to casing structural health and casing-to-rotor dynamics loops. The internally isolated circuitry produces a steady DC bias voltage loop to verify system continuity and cross-talk suppression. This layout isolates external electrical path noise, preventing high-frequency ground loop currents or stray magnetic field interference from distorting adjacent transducer readings or overlapping control cards.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Content\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) integrated Bently Nevada 330525 Velomitor XA sensor base with an M8 x 1.25 threaded stud adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory sheet containing original calibration verification loop data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterconnecting Mil-C-5015 cabling kits and auxiliary terminal rack monitors are excluded from this standard bundle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFreight Packing and Dispatch Logistics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Processing Window:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConsignments are packed for warehouse dispatch within 2-7 days when payment finish confirmation is logged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpress Delivery Carriers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShipments route via premium international priority transit networks including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrostatic Defect Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComponents travel individual-sealed inside rugged anti-static industrial packaging to maintain absolute structural isolation and eliminate latent static breakdown risk during transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Pad Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachine the casing structural pad until it matches a flatness profile of 0.8 micrometers Ra. Apply a light, uniform coat of industrial silicone grease or acoustic coupling paste to the mounting threads before torquing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManually engage the M8 x 1.25 threaded stud into the prepared machinery recess, then use a calibrated torque wrench to lock the sensor body down to a maximum limit of 4.5 N-m (40 in-lb). Do not over-torque to avoid permanent degradation of the internal piezoelectric crystal stack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the 2-pin Mil-C-5015 mating cable collar firmly to achieve a hermetic environmental seal. Route the twisted-pair cable assembly inside grounded metal conduit paths, landing the outer drain shield wire exclusively at the monitor instrument rack ground terminal to ensure complete cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is loop health monitored when the machinery monitor lacks a gap voltage validation target?\u003c\/p\u003e\n\u003cp\u003eA: The transducer maintains a steady internal DC bias voltage verification cycle over the 2-wire interface. Under static, non-fault operating conditions, the loop exhibits a constant bias voltage between 10 VDC and 14 VDC. Values tracking outside this window alert the monitoring system to an open field wire or a crushed cable short circuit.\u003c\/p\u003e\n\u003cp\u003eQ: Can this sensor undergo field adjustment to alter its nominal scale factor sensitivity?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal piezoelectric integration matrix is permanently laser-welded and sealed hermetically at the factory. No adjustments can be executed in the field; sensors that shift outside the nominal 3.94 mV\/mm\/s tolerance range during loop testing must be replaced.\u003c\/p\u003e\n\u003cp\u003eQ: Does mounting the hardware on an ungrounded bearing housing disrupt signal stability?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal sensing elements and integrated amplifier circuitry are entirely isolated from the stainless-steel outer casing. This electrical separation blocks local ground loop noise and ensures continuous cross-talk suppression.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518826864813,"sku":"330525-02","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330525-02-velomitor-xa-piezo-velocity-sensor-lbjnnagqvrs.jpg?v=1766979724"},{"product_id":"330881-16-10-105-06-02-bently-nevada-proximity-probes-proxpac-xl","title":"330881-16-10-105-06-02 Bently Nevada Proximity Probes PROXPAC XL","description":"\u003cp\u003eConfigured for integrated radial vibration and axial position measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-16-10-105-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes) provides direct physical\/electrical execution of signal transduction. This unit consolidates the Proximitor sensor and probe assembly into a single housing, outputting a voltage signal proportional to the gap between the probe tip and the observed conductive target. It operates as a self-contained transducer system for monitoring shaft dynamics within machinery protection networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330881-16-10-105-06-02 assembly is defined by the following configuration parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16: Probe style and mounting configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Case length (100 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e105: Total length (10.5 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e06: Connector interface type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Agency approval and calibration classification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-16-10-105-06-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 x 30 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC to 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics \u0026amp; Signal Conditioning Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL system utilizes standard eddy-current probe scaling to ensure linear voltage output relative to shaft displacement. During site installation, gap voltage validation remains a primary requirement; technicians must calibrate the static gap to target -10 VDC at the monitor input. Rotor dynamics analysis relies on the high-frequency response of this integrated assembly to detect sub-synchronous vibration, rotor bow, or bearing wear. Cross-talk suppression is achieved through internal shielding within the integrated housing, preventing interference from adjacent probes in high-density instrumentation arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881 PROXPAC XL Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThreaded locknut set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation and technical data sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: System requires compatible power supply and monitor input configuration; no external Proximitor module is required for this integrated unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGap Verification: Position the probe tip using a feeler gauge to achieve the nominal -10 VDC output at the monitoring terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Secure the integrated housing using the provided locknuts, ensuring the assembly is rigid to prevent spurious signal noise from mechanical resonance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring Shielding: Route the transducer output through grounded metallic conduit to eliminate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Reference: Ensure the DC supply is filtered and grounded according to the machine control system specifications to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSurface Maintenance: Verify that the target shaft surface is free from non-conductive residues or machining burrs prior to operational startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this unit be hot-swapped while the machine is running?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. Removing or installing the probe while the machine is operational will cause signal loss and potential damage to the monitor channel inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the PROXPAC XL differ from a two-piece system?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The PROXPAC XL integrates the Proximitor circuitry into the probe housing, eliminating the need for a separate extension cable and Proximitor mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the system compatible with standard 3300 XL monitors?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, provided the monitor input card is configured to accept the voltage output characteristics of the integrated PROXPAC XL assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten the 10.5-meter cable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The cable is a fixed component of the factory-tuned system impedance. Modifications will result in calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum operating distance for the output signal?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The signal distance is determined by the output impedance and cable quality; refer to the 330881 manual for maximum recommended signal run lengths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe tip protected?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The tip is constructed from PPS (Polyphenylene Sulfide), providing electrical insulation and mechanical resilience against typical process fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the unit be used in explosive environments?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Installation in hazardous areas requires the specific model variant with appropriate agency certification. Verify the label approval codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a failure of the internal electronics?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Failure typically manifests as a loss of signal (near 0 VDC) or a saturated signal (near negative supply rail) detected by the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518826963117,"sku":"330881-16-10-105-06-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-16-10-105-06-02-proxpac-xl-proximity-transducer-2muxlqx55e3.jpg?v=1766979731"},{"product_id":"bently-nevada-330881-28-08-050-03-02-proxpac-xl-proximity-transducer-assembly","title":"Bently Nevada 330881-28-08-050-03-02 PROXPAC XL Proximity Transducer Assembly","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-08-050-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROXPAC XL Assembly, operates as a dedicated hardware component for integrated displacement measurement within 3300 XL monitoring platforms. This assembly combines the probe, extension cable, and Proximitor sensor into a unified housing, executing direct physical signal transduction to capture instantaneous relative motion between the sensor tip and a conductive target.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881: PROXPAC XL Proximity Transducer Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e28: Total Case Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: Probe Tip Style (8 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e050: Cable Length (5.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e03: Connector Type (Miniature coaxial ClickLoc)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Agency Approval (Multiple approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-08-050-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.95 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 cm x 25 cm x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mA typical at -24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; Eddy-Current Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL system utilizes standard eddy-current probe scaling to convert target displacement into a linear voltage signal. To ensure accurate rotor dynamics analysis, installers must perform gap voltage validation, targeting a -10 VDC setpoint at the monitor output. Cross-talk suppression is critical in multi-probe installations; maintain a minimum clearance of 40 mm between adjacent probe tips to prevent 1 MHz carrier frequency interference, which could otherwise introduce harmonic noise into the vibration data stream.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330881-28-08-050-03-02 PROXPAC XL Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Mounting accessory kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Secure the integrated housing to a rigid, vibration-isolated surface to prevent structural resonance within the transducer assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Cabling: Utilize grounded metallic conduit for the output signal cable to provide robust shielding against electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Verify all internal connections are factory-sealed; ensure the external output connector is fully seated and locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Establish a low-impedance connection to the machine instrument earth to prevent ground loop currents that affect signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Adjustment: Use a feeler gauge to set the initial probe gap, then verify the voltage reading at the Proximitor test point during cold-state commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the PROXPAC XL considered an \"integrated\" system?\u003c\/p\u003e\n\u003cp\u003eA: It houses the Proximitor sensor and probe interface within a single protective enclosure, reducing field wiring complexity and environmental exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the probe tip be replaced if damaged?\u003c\/p\u003e\n\u003cp\u003eA: No. The PROXPAC XL is a factory-calibrated assembly; any mechanical damage to the tip or cable requires replacement of the entire unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the system sensitive to target material?\u003c\/p\u003e\n\u003cp\u003eA: Yes, calibration is optimized for 4140 steel. Using materials with different magnetic permeability requires specific scale factor recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the 12 mA power consumption?\u003c\/p\u003e\n\u003cp\u003eA: This constant current draw is required by the internal Proximitor circuitry to drive the 1 MHz carrier frequency signal used in eddy-current detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the assembly be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the \"02\" agency approval suffix matches the requirements for the site hazardous area classification and is used with approved barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does cable length affect performance?\u003c\/p\u003e\n\u003cp\u003eA: The system is factory-calibrated for the specified cable length; modifying the cable introduces impedance mismatches and phase errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a system failure?\u003c\/p\u003e\n\u003cp\u003eA: A failure usually manifests as a hard-scale voltage (e.g., -24 VDC) at the output, signaling an internal component fault or cable break.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify the gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: Measure the DC voltage between the \"OUT\" and \"COM\" terminals on the output connector while the machine is at rest.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518827487405,"sku":"330881-28-08-050-03-02","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-08-050-03-02-proxpac-xl-proximity-transducer-assembly-a0ktxkt1lmb.jpg?v=1766979756"},{"product_id":"106765-13-bently-nevada-3300-series-velocity-sensor-armored-cable","title":"106765-13 Bently Nevada 3300 Series Velocity Sensor Armored Cable","description":"\u003cp\u003eConfigured for high-integrity vibration signal transmission in Machinery Protection Systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 106765-13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e106765-13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eArmored Cable) provides direct physical\/electrical execution. This specialized interconnect assembly links industrial velocity transducers to data acquisition racks, routing low-voltage dynamic voltage waveforms across harsh physical fields without signal attenuation or phase distortion.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e106765-13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Application\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTurbine Supervisory Instrumentation (TSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVelocity Sensor Interconnect Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless steel flexible armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwisted, shielded pairs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (0 mA internal consumption)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 100 M\\Omega\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 x 25.4 x 7.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +121 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-55 to +150 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% condensing, moisture-sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe architectural design of this armored assembly focuses directly on preserving raw wave characteristics critical to advanced rotor dynamics assessment. By incorporating high-density braided shielding alongside tight conductor twist ratios, the cable achieves maximum cross-talk suppression between adjacent dynamic transducer lines. This structural isolation ensures that low-amplitude casing velocity waves remain uncorrupted by ambient high-frequency electromagnetic noise, preserving precise phase tracking for multi-channel synchronous machinery diagnostics.\u003c\/p\u003e\n\u003ch3\u003eTransducer Interface Diagnostics\u003c\/h3\u003e\n\u003cp\u003eQ: How does the cable shielding layer affect overall system noise rejection performance?\u003c\/p\u003e\n\u003cp\u003eA: The continuous inner foil shield combined with a drain wire isolates the active signal pair from external capacitive and inductive fields. This construction layout guarantees that external electrostatic discharges or stray industrial noise do not skew the dynamic casing velocity calculations.\u003c\/p\u003e\n\u003cp\u003eQ: What structural changes occur if the physical bend radius is forced below the technical limits?\u003c\/p\u003e\n\u003cp\u003eA: Forcing sharp kinks or tight bends below the minimum specified radius compresses the inner dielectric layer and deforms the outer stainless steel armor braid. This structural alteration changes the baseline line capacitance parameters, causing signal reflections and degradation of high-frequency phase accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Does this passive component require specific calibration matching to an individual velocity sensor?\u003c\/p\u003e\n\u003cp\u003eA: No. The assembly delivers a uniform electrical impedance profile across standard dynamic frequency spectra. While electrical tracking parameters are transparent, overall loop scaling configuration must be entered and validated inside the linked monitor channel setup.\u003c\/p\u003e\n\u003ch3\u003eField Component Installation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmor Bonding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate the inner copper drain wire exclusively at the monitor rack shield bus bar point. Leave the transducer end of the shield completely isolated and insulated to eliminate ground loop currents across the machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting Separation Guidelines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDo not route this dynamic sensor cable inside trays containing heavy AC distribution wiring, motor lines, or high-power switching feeds. Use separate dedicated conduits to maintain maximum signal purity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Strain Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure sufficient physical slack is maintained at the sensor connector junction. Use robust cable clamps to anchor the armored casing firmly near the transducer body, preventing structural machine vibration from fatiguing the connection point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Configuration List\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 106765-13 Armored Cable Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical Connection Orientation Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Velocity sensors, dynamic line termination boxes, and flexible outer conduit seals are excluded from this base package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Packaging Matrix\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish protocols are completed within the logistics queue. Consignments originate from the Xiamen, China facility, using express global distribution tracks handled by DHL, FEDEX, or UPS. The hardware items travel protected within heat-sealed anti-static industrial packaging enclosures layered inside rigid shock-absorbent outer cartons to prevent any structural deformation during transport.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518827716781,"sku":"106765-13","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-106765-13-velocity-sensor-armored-cable-dxf2segapzd.jpg?v=1766979765"},{"product_id":"bently-nevada-330881-01-00-000-00-02-proximity-probes-proxpac-xl","title":"Bently Nevada 330881-01-00-000-00-02 Proximity Probes PROXPAC XL","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330881-01-00-000-00-02 is an integrated transducer assembly from the PROXPAC XL product family. Unlike traditional proximity transducer systems that require separate probe, extension cable, and Proximitor components, the PROXPAC XL design houses the Proximitor sensor inside a ruggedized, protected housing integrated directly with the probe assembly. This consolidated architecture is specifically engineered to reduce installation complexity, minimize the footprint required for instrumentation, and eliminate the need for separate field wiring between the probe and the sensing electronics. By utilizing the proven eddy-current sensing technology of the 3300 XL platform, the 330881 provides industry-leading accuracy for monitoring radial vibration and axial shaft position in critical rotating machinery. It is an ideal solution for retrofitting existing skids or deploying in space-constrained industrial environments where simplicity and reliability are paramount.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-01-00-000-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 x 30 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303\/304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC to 24 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple (Hazardous area options)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe 330881-01-00-000-00-02 part number denotes specific structural and electrical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e01: Probe style and housing configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Mounting thread orientation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Cable\/connector entry options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approvals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Standard calibration and output scaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe PROXPAC XL series is highly favored in environments where traditional multi-component transducer chains are difficult to implement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil and Gas Skids: Ideal for compressor and pump packages where cable routing and junction box space are limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote Monitoring Sites: Reducing the number of potential failure points in the electrical loop makes it suitable for unmanned or remote platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpace-Constrained Turbomachinery: Perfect for tight bearing housings or turbine sections where separate Proximitor mounting is physically impossible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy System Retrofits: Easily replacing older, less reliable monitoring technologies with the high-performance 3300 XL sensing engine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Generation Auxiliaries: Monitoring small-to-medium turbines, generators, and large centrifugal fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330881-01-00-000-00-02 is fully compatible with Bently Nevada 3500 Machinery Protection Systems and other standard monitoring platforms capable of accepting a 4-20 mA or raw buffered voltage input. Because the Proximitor is integrated into the probe assembly, the entire system must be viewed as a single, calibrated unit. Ensure that the monitor channel is configured to match the specific scale factor and output impedance of the PROXPAC XL. It is not intended to be \"mixed and matched\" with separate 3300 XL probes or extension cables; the integrated nature of the device provides a unique electrical loop that is factory-calibrated for optimal linear performance.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePre-Installation Inspection: Check the probe tip and housing for any shipping damage. Ensure the threads are clear of debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Verification: Use a standard gap-setting tool. Adjust the probe until the desired static voltage (typically -10 VDC center-point) is reached.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Security: Use the provided locknuts. Ensure the probe is mounted rigidly; any mechanical looseness will introduce artificial vibration noise into the signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Connection: The unit requires a clean DC power supply. Ensure the wiring is shielded and routed away from high-power AC lines to prevent induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Establish a common ground between the PROXPAC XL housing and the machine frame to ensure accurate signal reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReduced Installation Labor: The integrated design eliminates the need for separate Proximitor mounting, saving hours of field wiring and setup time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimized Failure Points: By removing the extension cable\/connector interface typically found in 3300 XL systems, the PROXPAC XL significantly increases the overall reliability of the sensing loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact Footprint: Essential for modern, high-density machinery skids where every inch of space is critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProven Performance: Built upon the core technology of the 3300 XL, ensuring that users get the same accuracy, linearity, and temperature stability as the standard two-piece system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881-01-00-000-00-02: PROXPAC XL Transducer Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation manual and technical datasheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting accessories (locknuts and spacers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Verify the required mounting thread and length configuration prior to ordering to ensure proper fitment for the specific machinery bore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does PROXPAC XL differ from a standard 3300 XL system?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: PROXPAC XL integrates the Proximitor sensor directly with the probe, removing the need for a separate Proximitor box and extension cable.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with the 3500 monitor?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, it provides standard output signals compatible with Bently Nevada 3500 and other industry-standard vibration monitoring hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I repair the PROXPAC XL if the cable breaks?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the PROXPAC XL is a sealed, integrated assembly. If the cable or housing is damaged, the entire unit must be replaced to maintain calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What happens if the internal Proximitor fails?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Since the sensing engine is integrated into the probe housing, the entire PROXPAC unit would be replaced. This is often faster than troubleshooting a two-piece system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the assembly waterproof?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The housing is ruggedized, but it is not intended for full submersion. Ensure all conduit and junction boxes are properly sealed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What are the primary benefits for procurement teams?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Fewer part numbers to manage, reduced inventory, and significant labor savings during machinery commissioning and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does it require special training to install?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, it installs similarly to standard probes, though users should be aware that the Proximitor is integrated, reducing the wiring complexity.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used in high-temperature gas turbines?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: It is rated for industrial environments; check the temperature specifications to ensure it fits the specific turbine casing thermal profile.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the output calibrated?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Each unit is factory-calibrated for standard linear output (200 mV\/mil). No field calibration of the internal Proximitor is required or possible.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why choose an integrated system over a traditional one?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Integration reduces cable connections, which are historically the weakest point in vibration monitoring loops. It increases MTBF (Mean Time Between Failure).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518827815085,"sku":"330881-01-00-000-00-02","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-01-00-000-00-02-proxpac-xl-proximity-transducer-rgc2aw50x4s.jpg?v=1766979770"},{"product_id":"330881-28-10-140-00-02-bently-nevada-proxpac-xl-proximity-transducer","title":"330881-28-10-140-00-02 Bently Nevada PROXPAC XL Proximity Transducer","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 330881-28-10-140-00-02 is an all-in-one proximity sensing solution from Bently Nevada's PROXPAC XL line.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis advanced transducer system integrates an 8mm probe (noted here in the 10mm body configuration) with a 3300 XL Proximitor sensor housed within a single,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eruggedized enclosure.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy combining the sensing element and signal conditioning electronics into one unit,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe PROXPAC XL eliminates the need for separate extension cables and external sensor housings.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific model features an extended 140mm thread length,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the necessary reach for deep-port mounting through machine casings.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to deliver deterministic displacement and vibration data directly to monitoring systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003estreamlining the architecture of Turbine Supervisory Instrumentation (TSI).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eDesign Architecture and Hardware Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Electronics:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in 3300 XL Proximitor sensor reduces signal loss and installation complexity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensional Profile:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3\/8-24 UNF thread with a specialized 140mm (approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 inches) total length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIP66 and Type 4X rated housing protects against high-pressure water and corrosive vapors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Tolerance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOperational range from -40°C to +120°C (-40°F to +248°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMaterial Calibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for AISI 4140 steel targets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Output:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandardized voltage output proportional to shaft distance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation Layout:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSimplifies high-density deployments by removing the need for intermediate cable connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDurability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRobust aluminum or stainless steel housing options for high-vibration environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Monitoring and System Deployment\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe PROXPAC XL 330881-28-10-140-00-02 is specifically engineered for critical rotating machinery where traditional multi-component proximity systems are difficult to install or maintain.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 140mm extended reach is vital for monitoring radial vibration and axial thrust position on large steam turbines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003egenerators,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand industrial gearboxes where thick insulation or heavy outer casings must be bypassed.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBecause it integrates the Proximitor directly at the measurement point,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit is highly effective in reducing the electromagnetic interference (EMI) often picked up by long extension cables.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis system is a cornerstone for predictive maintenance programs in power generation and heavy manufacturing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding stable and accurate data to Bently Nevada 3500 series racks for automated machinery protection and diagnostic trend analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518830141613,"sku":"330881-28-10-140-00-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-10-140-00-02-proxpac-xl-proximity-transducer-nxcnkqeay3n.jpg?v=1766979796"},{"product_id":"330881-28-10-100-03-02-bently-nevada-proximity-transducer-3300-series","title":"330881-28-10-100-03-02 Bently Nevada Proximity Transducer 3300 Series","description":"\u003cp\u003eConfigured for displacement and vibration monitoring in industrial rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-10-100-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical\/electrical execution of non-contact shaft position sensing. This transducer system utilizes eddy-current induction to generate a voltage signal proportional to the gap between the probe tip and the target surface. It operates by converting high-frequency excitation into a calibrated output, enabling precise tracking of shaft displacement and radial vibration. The component integrates into established machine monitoring loops, maintaining high signal linearity and frequency response across demanding industrial operating environments.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330881-28-10-100-03-02 is defined by a specific factory configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e28: Total probe length (standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100: Overall case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e03: Connector type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Agency approval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-10-100-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 x 25 x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerived from monitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProportional voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI \u0026amp; Mechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eEddy-current probe scaling is calibrated to ensure output linearity over the specified measurement range. During installation, gap voltage validation is mandatory; installers must target -10 VDC when the probe is positioned at the center of its linear range. Rotor dynamics analysis depends on this precise gap setting to accurately capture shaft centerline position and vibration vectors. To ensure signal integrity, cross-talk suppression techniques must be applied by maintaining sufficient spacing between adjacent probes to prevent frequency beat interference from overlapping excitation signals.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330881 Proximity Transducer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical installation manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective thread cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard mounting accessories not included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Use a feeler gauge to establish the initial gap and confirm the output voltage with a multimeter at the monitor input terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque Application: Apply specified torque to the probe locknut to prevent loosening caused by machine casing vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the coaxial cable is routed in dedicated conduit to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Verify electrical continuity between the transducer case and the machine ground to establish a stable signal reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTarget Verification: Confirm the target surface is free of non-conductive coatings or debris that could impede eddy-current propagation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this transducer system compatible with all 3300 series monitors?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, it must be used with monitor modules configured specifically for this transducer's frequency and scaling parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the -10 VDC gap target?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: It centers the probe within its linear range, ensuring that both positive and negative vibration excursions are captured without signal clipping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I extend the coaxial cable length in the field?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the system calibration is dependent on the integral cable length; modification will result in impedance changes and measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the probe tip handle high temperatures?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The PPS tip is designed for continuous operation up to 177 deg C, maintaining structural and electrical stability under thermal stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary cause of signal drift?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Drift is typically caused by temperature changes, mechanical loosening of the probe, or surface degradation of the observed target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I test the transducer for faults?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Perform a static gap check and observe the raw output voltage for noise or discontinuities while the machine is at rest.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this be used for axial position measurement?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, it is suitable for both radial vibration and axial position (thrust) measurements, provided the mounting is rigid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the transducer require separate power?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, it is powered through the coaxial cable by the associated monitoring system or Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518830207149,"sku":"330881-28-10-100-03-02","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-10-100-03-02-proxpac-xl-proximity-transducer-mkxvrede2pg.jpg?v=1766979800"},{"product_id":"330180-51-05-bently-nevada-3300-xl-5-8-mm-proximitor-sensor","title":"330180-51-05 Bently Nevada 3300 XL 5\/8 mm Proximitor Sensor","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 330180-51-05 is a high-precision signal conditioning module engineered for the 3300 XL Proximity Transducer System.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis Proximitor sensor acts as the electronic core for non-contacting displacement measurements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting raw eddy-current signals from a proximity probe into a stabilized linear voltage output.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe resulting signal is directly proportional to the physical gap between the probe tip and the target conductive surface,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as a machine shaft.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eAs a fundamental component of Turbine Supervisory Instrumentation (TSI),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 330180-51-05 is designed for high-fidelity monitoring of rotating equipment.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is factory-calibrated to support a 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0-meter total system length,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the essential data required for radial vibration analysis,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eaxial thrust position monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand Keyphasor speed sensing on critical assets like steam turbines and centrifugal compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCore Technical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFull API 670 Compliance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to meet stringent industrial standards for mechanical configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003elinear measurement range,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand exceptional thermal stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEddy-Current Signal Processing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTranslates physical shaft movement into a precise analog voltage (standard 200 mV\/mil),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for real-time monitoring of machinery health.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eComponent Interchangeability:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePart of the 3300 XL \"universal match\" architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing probes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eextension cables,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand sensors to be swapped without the need for manual bench calibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRugged Mechanical Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with systems utilizing CableLoc technology,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring a 330 N (75 lbf) pull strength to prevent accidental cable detachment in high-vibration environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSuperior Environmental Resilience:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to operate reliably in harsh industrial climates with an operating temperature range of -40°C to +85°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures advanced RFI\/EMI shielding to minimize electrical noise interference,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring stable data transmission to monitoring racks like the Bently Nevada 3500 series.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e330180-51-05\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Series:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 5\/8 mm \/ 3300 Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Calibration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Meters (16.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 ft)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-17.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 VDC to -26 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLinear Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFrequency Response:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 Hz (DC) to 10 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 x 3.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 x 7 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHS Code:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Application Areas\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTurbo-Machinery Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eContinuous monitoring of axial displacement and radial vibration in gas and steam turbines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOil \u0026amp; Gas Processing:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-reliability sensing for centrifugal compressors and turbo-expanders.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Generation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAccurate Keyphasor timing and speed detection for large-scale generator sets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePredictive Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding stabilized analog inputs for Bently Nevada System 1 condition monitoring platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518830403757,"sku":"330180-51-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330180-51-05-3300-xl-5-8-mm-proximitor-sensor-lrnhxglfxd4.jpg?v=1766979809"},{"product_id":"177230-02-02-05-seismic-transmitter-bently-nevada-vibration-sensor","title":"177230-02-02-05 Seismic Transmitter | Bently Nevada | Vibration Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 177230-02-02-05 is a compact seismic transmitter used to monitor machine casing or structural vibration on rotating equipment. Installed directly on a bearing housing, casing, or support structure, it converts mechanical vibration into a conditioned electrical signal suitable for continuous condition monitoring and basic protection functions.\u003c\/p\u003e\n\u003cp\u003eThis transmitter style is commonly selected when non-contact proximity probes are not practical, or when a simple, robust vibration measurement is required at the machine casing. The small footprint supports installation in tight locations while maintaining stable measurement performance for long-term trending.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003e177230-02-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eSeismic Transmitter (casing vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd\u003eSeismic vibration sensing with integrated electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eConditioned transmitter output for monitoring systems (typical industrial transmitter interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard surface mounting to rigid machine structure (bearing housing\/casing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade construction for high-vibration environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating intent\u003c\/td\u003e\n\u003ctd\u003eContinuous vibration trending and early fault indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. dimensions\u003c\/td\u003e\n\u003ctd\u003e7 × 2.8 × 2.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. weight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCasing vibration monitoring on pumps, motors, gearboxes, fans, and general rotating assets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupplemental measurement points on compressors and turbines where casing vibration is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliability programs using continuous trending to detect developing faults such as looseness, imbalance, misalignment, and resonance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofits where existing monitoring infrastructure requires an additional seismic vibration channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallations in restricted spaces where compact, integrated transmitters reduce wiring complexity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518830895277,"sku":"177230-02-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-177230-02-02-05-seismic-transmitter-wb34xcgkf1r.jpg?v=1766979828"},{"product_id":"330881-28-00-110-03-02-bently-nevada-proximity-transducer-proxpac-xl-series","title":"330881-28-00-110-03-02 Bently Nevada Proximity Transducer PROXPAC XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-00-110-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer, operates as a dedicated hardware component for non-contacting vibration and displacement measurements within PROXPAC XL Series machinery monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configurations\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330881\u003c\/strong\u003e: Base Model Number for PROXPAC XL Proximity Transducer System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-28\u003c\/strong\u003e: 8 mm probe thread with 3\/8-24 UNF thread profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded length option specified as 0.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-110\u003c\/strong\u003e: Case length option specified as 11.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03\u003c\/strong\u003e: Total system length option specified as 0.5 m (1.6 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Agency approval option indicating multi-certification for hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-00-110-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32.0 cm x 24.0 cm x 18.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDriven by external Proximitor Sensor loop (-24 VDC nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal when paired with 8 mm XL probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) starting at approximately -2.0 VDC gap voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Scaling and Rotor Dynamics Calibration\u003c\/h3\u003e\n\u003cp\u003eThis PROXPAC XL Series hardware assembly relies on precise eddy-current probe scaling to convert physical dynamic distance into analog voltage. During commissioning, gap voltage validation requires setting the target static voltage to -10 VDC, corresponding to the midpoint of the linear calibration curves for standard 8 mm rotor dynamics tracking. Cross-talk suppression is integrated via specific internal coil shielding, preventing electromagnetic interference from adjacent eddy-current fields when multiple transducers are positioned in close proximity on the same bearing housing plane.\u003c\/p\u003e\n\u003ch3\u003eProcurement Package Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) integrated PROXPAC XL transducer assembly with internal 8 mm probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcrete installation hardware kit including silastic sealant and anti-seize lubricant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSilicon rubber connector protection sleeve for field termination isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory calibration datasheet documenting baseline cross-talk suppression and scaling variables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Layout and Mechanical Alignment\u003c\/h3\u003e\n\u003cp\u003ePrior to permanent mechanical lockdown, the internal probe must be threaded into position using a calibrated voltmeter to verify the target -10 VDC gap voltage under static rotor conditions. Secure the outer housing to the machinery casing using a standard NPT thread profile, ensuring a minimum of 5 full thread engagement rounds to maintain pressure containment and structural integrity under high-vibration loads. Signal transmission lines require 100% isolated conduit runs with single-point shield grounding at the monitor rack instrumentation bulkhead to eliminate potential ground loop currents.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Dispatch Criteria\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish through DHL\/FEDEX\/UPS. All shipments are dispatched inside specialized anti-static industrial packaging complete with dense moisture-absorbent desiccants and custom-molded high-density polyethylene protective foam inserts to safeguard electrical and mechanical calibrations during transit.\u003c\/p\u003e\n\u003ch3\u003eStructural Performance FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: How does total system length affect the output calibration?\u003c\/p\u003e\n\u003cp\u003eA: The probe and internal matching cable are calibrated to specific length matrices. Altering or cutting the 0.5 m system cable ruins the eddy-current probe scaling, inducing non-linear voltage errors across the measurement scale.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of hot-swap intervention while the machinery is operating?\u003c\/p\u003e\n\u003cp\u003eA: The physical housing and probe cannot be extracted during machine operation due to pressure and mechanical alignment constraints. However, the electrical loop connection to the external Proximitor can be disconnected without interrupting other active monitoring channels on the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What indicates an out-of-tolerance gap alignment during installation?\u003c\/p\u003e\n\u003cp\u003eA: If the measured gap voltage reads less than -2.0 VDC or greater than -18.0 VDC, the transducer is positioned outside its calibrated linear range, meaning the system will flag an immediate NOT OK diagnostic status.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518831222957,"sku":"330881-28-00-110-03-02","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-00-110-03-02-proxpac-xl-proximity-transducer-dtknmzewujt.jpg?v=1766979838"},{"product_id":"330881-28-11-214-00-02-bently-nevada-proxpac-xl-proximity-transducer","title":"330881-28-11-214-00-02 Bently Nevada PROXPAC XL Proximity Transducer","description":"\u003cp\u003eConfigured for dynamic vibration and shaft position monitoring in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-11-214-00-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Transducer) provides direct physical\/electrical execution. It integrates a proximity sensor probe and driver circuitry into a unified housing to generate continuous electrical signals directly proportional to the physical gap between the probe tip and the observed conductive target material.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-11-214-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e152 mm x 152 mm x 102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNominal 24 VDC at 12 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLinear voltage proportional to distance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel targets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe hardware relies on eddy-current probe scaling optimized for AISI 4140 steel targets to maintain a linear scale factor over the standard operating range. During commissioning, gap voltage validation (-10 VDC targets) must be verified using a calibrated digital multimeter at the probe terminal layer to position the sensor precisely within the linear center of the RF magnetic field. Correct calibration minimizes cross-talk suppression failures when multiple transducers are positioned in close proximity around the rotor bearing housing. Accurate tracking of high-frequency shaft displacements provides reliable orbital plots for real-time analysis of complex rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) integrated PROXPAC XL assembly including internal proximity probe and transducer electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) silicon fluid-resistant sealing gasket for conduit connection ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) installation manual containing calibration graphs and factory verification certificates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOn-Site Deployment and Wiring Rules\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminal connections must isolate shield wires from the transducer housing body. The common shield must terminate at the monitoring rack instrumentation ground plate only to prevent ground loop noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure all conduit fittings match the housing NPT threads. Engage a minimum of 5 full thread turns to maintain environmental sealing integrity and prevent moisture ingress into the internal probe cavity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse a precise mechanical micrometer or monitor the gap voltage directly until the output reaches the designated electrical mid-point before locking the mounting bolts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Shipping Protocols\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 3-5 days when payment finish via DHL\/FEDEX\/UPS. All units are shipped inside specialized anti-static industrial packaging to neutralize static charge buildup during transit. Heavy-gauge outer corrugated shielding protects the delicate integrated electronics from physical shock and mechanical vibration during global dispatch.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: How is cross-talk suppression managed when multiple probes are near each other?\u003c\/p\u003e\n\u003cp\u003eA: Cross-talk suppression requires physical spacing of at least 40 mm between probe tips to prevent the overlapping of the high-frequency RF magnetic fields generated by adjacent transducers.\u003c\/p\u003e\n\u003cp\u003eQ: What is the significance of the gap voltage validation (-10 VDC targets)?\u003c\/p\u003e\n\u003cp\u003eA: A -10 VDC reading signifies that the physical gap between the probe tip and the target material is centered within the 80 mil (2 mm) linear range of the eddy-current probe scaling matrix.\u003c\/p\u003e\n\u003cp\u003eQ: Can the internal electronics withstand continuous physical vibration?\u003c\/p\u003e\n\u003cp\u003eA: The internal transducer components are fully encapsulated in a potting compound to isolate the circuit boards from high-frequency structural vibration and mechanical shock.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518831517869,"sku":"330881-28-11-214-00-02","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-11-214-00-02-proxpac-xl-proximity-transducer-pg2hvgeahjj.jpg?v=1766979854"},{"product_id":"330881-28-10-148-03-02-bently-nevada-proxpac-xl-proximity-transducer-3300-proximity-transducer-system","title":"330881-28-10-148-03-02 Bently Nevada PROXPAC XL Proximity Transducer 3300 Proximity Transducer System","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330881-28-10-148-03-02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330881\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePROXPAC XL Proximity Transducer, operates as a dedicated hardware component for contactless proximity displacement sensing within 3300 Proximity Transducer System platforms. The integrated hardware directly channels raw eddy-current voltage data via terminal paths to machinery monitoring instruments without an intervening coaxial extension cable line.\u003c\/p\u003e\n\u003ch3\u003eOperational Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330881-28-10-148-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32.02 x 12.0 x 9.14 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDriven by parent TSI rack interface (Typically 12 mA @ -24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Metric\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mm tip diameter with integrated 148 mm threaded sleeve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS) composite reinforced with glass and conductive fibers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType 4X, IP66\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Sensor Core\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL Proximitor module board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSI (Turbine Supervisory Instrumentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Mechanical Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe configuration of the 330881-28-10-148-03-02 dictates fixed eddy-current probe scaling baselines governed by the 10 mm target tracking face. Execution of gap voltage validation (-10 VDC targets) occurs through manual position modification of the 148 mm integrated thread track inside the machinery casing. This direct anchoring framework mitigates high-frequency signal attenuation over extended paths, enhancing cross-talk suppression inside fluid-bearing housings where precise assessment of multi-axis rotor dynamics is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries and Response Manifest\u003c\/h3\u003e\n\u003cp\u003eQ: How does the integrated 3300 XL Proximitor circuit board alter standard field wiring loops?\u003c\/p\u003e\n\u003cp\u003eA: The internal mounting of the sensor circuit inside the PPS housing cover eliminates the coaxial extension cable entirely. Field technicians terminate multi-conductor field wiring directly to the terminal strips housed inside the local unit cover.\u003c\/p\u003e\n\u003cp\u003eQ: What structural benefit does the Polyphenylene Sulfide (PPS) composite configuration provide over metal enclosures?\u003c\/p\u003e\n\u003cp\u003eA: The glass and conductive fiber-reinforced PPS compound establishes a passive electrostatic dissipation path, shielding internal proximity circuitry from transient industrial voltages while meeting Type 4X and IP66 sealing baselines.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping or field modification of the internal sensor component permitted under load?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnecting field terminal blocks or unseating the housing cap while the channel is energized can induce static variables that trigger false alarm sequences within the connected TSI monitor card.\u003c\/p\u003e\n\u003ch3\u003eField Alignment Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate all diagnostic power sources from the machinery monitoring loops before adjusting the housing installation bolts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeat the 148 mm probe barrel into the machined housing bore, taking care not to scrape or fracture the 10 mm PPS sensor tip against internal casing paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotate the threaded sleeve until the electrical output verification reads the targeted -10 VDC baseline voltage across the diagnostic ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFasten the structural hex jam nuts to the specific mechanical torque limit to prevent rotation drift under heavy vibrational loading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all field terminal lines via liquid-tight flexible conduits, grounding cable shields at the terminal block framework inside the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupply Kit Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330881-28-10-148-03-02 Integrated Transducer Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Sealed Nitrile Housing Gasket Profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical Hardware Verification Slip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistical Packaging Profiles\u003c\/h3\u003e\n\u003cp\u003eHardware elements are packed inside high-durability anti-static industrial packaging to fully insulate the local electronics from ESD vectors during transit. Final air express shipments maintain standard logistical fulfillment tracking windows between 2-7 days when payment finish through certified DHL\/FEDEX\/UPS courier hubs.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518831943853,"sku":"330881-28-10-148-03-02","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330881-28-10-148-03-02-proxpac-xl-proximity-transducer-vqwu5u5dc1y.jpg?v=1766979872"}],"url":"https:\/\/www.maxwellplc.com\/collections\/bently-nevada-sensor.oembed?page=17","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}