{"title":"Bently Nevada 3300 XL 8mm Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 XL 8mm Proximity Transducer System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the industry standard for non-contacting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplacement and vibration measurement\u003c\/strong\u003e. Engineered for extreme industrial environments, these probes offer superior performance in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emachinery diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoverspeed protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor critical rotating assets.\u003c\/p\u003e\n\u003cp\u003eWhether you are maintaining legacy systems or integrating new\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware, our inventory covers the complete range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeddy current sensors\u003c\/strong\u003e. These 8mm probes provide a linear range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80 mils (2.0 mm)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand are fully compliant with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAPI 670 standards\u003c\/strong\u003e. As a dedicated B2B supplier, we specialize in providing technical specifications and competitive lead times for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 8mm probes\u003c\/strong\u003e, including various thread sizes and unthreaded lengths to match your specific mounting requirements.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-330101-00-60-10-02-00-proximity-probes-3300-xl-series","title":"Bently Nevada 330101-00-60-10-02-00 Proximity Probes 3300 XL Series","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-60-10-02-00 is a foundational sensor within the 3300 XL 8 mm Proximity Transducer System, specifically engineered for the high-fidelity measurement of radial shaft vibration, axial position, and shaft speed in rotating machinery. This probe utilizes eddy-current technology to detect changes in the gap between the probe tip and a conductive target surface, such as a turbine rotor or a pump shaft. As a primary input for Turbomachinery Supervisory Instrumentation (TSI), it provides the essential raw data required for protecting critical assets against excessive vibration and mechanical wear.\u003c\/p\u003e\n\u003cp\u003eBuilt for the demanding environments of power generation and hydrocarbon processing, the 330101 probe features a robust stainless-steel housing and an integrated coaxial cable with a high-temperature-rated tip. Its design allows it to perform reliably in environments saturated with oil, moisture, and high-intensity electromagnetic fields. By ensuring a consistent and linear output, this sensor supports predictive maintenance programs, helping operators identify mechanical imbalances, bearing degradation, and shaft misalignment long before these conditions lead to unplanned downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-60-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 cm x 1.5 cm x 112.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensing Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy-Current (Non-contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.01% (Linearity)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 2 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrand New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe part number 330101-00-60-10-02-00 defines a specific mechanical and electrical configuration required for integration into 3300 XL systems. The \"00\" indicates the standard mounting thread, while the \"60\" specifies the precise physical probe length in centimeters, ensuring it reaches the shaft with the correct clearance. The \"10-02-00\" suffix represents the integrated cable length, connector type, and calibration options. This specific build is calibrated for standard 4140 steel targets, ensuring that the voltage output from the Proximitor sensor remains perfectly linear across the entire 80 mil (2 mm) linear range, which is the hallmark of the 3300 XL 8 mm family.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and Gas Turbines: Providing real-time shaft orbit and radial vibration data to detect early signs of rotor instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal Compressors: Monitoring shaft axial position to prevent thrust bearing failure in high-pressure gas compression loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial Pumps: Tracking rotor vibration in multi-stage boiler feed pumps to optimize maintenance intervals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor-Generator Sets: Essential for detecting air-gap issues and shaft misalignment in high-voltage power generation units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResearch and Development: Used in experimental test benches to characterize the dynamic behavior of new rotating components under stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is fully compatible with the Bently Nevada 3300 XL 8 mm Transducer System. It must be paired with an appropriate 3300 XL Proximitor sensor and an extension cable of matching series. The system is designed for \"interchangeability,\" meaning that individual components (probe, cable, proximitor) can be replaced without the need for a full system recalibration, provided they are of the same series. It interfaces seamlessly with Bently Nevada 3500 and 3300 series monitoring racks, supporting long-distance signal transmission to control systems via standard DCS or PLC input modules.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePre-Installation Preparation: Inspect the probe tip for scratches and ensure that the shaft target surface is free from deep gouges or paint, which can interfere with the eddy-current field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Mechanics: Install the probe into the mounting bracket or housing. Use the provided lock nuts to secure the probe, ensuring it is perpendicular to the shaft to minimize measurement error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Utilize a precision feeler gauge to establish the initial gap. The probe must be adjusted until the Proximitor output registers the nominal -10 VDC gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling and Shielding: Route the coaxial cable through shielded conduits. Use Bently Nevada-approved connectors and avoid sharp bends that could compromise the cable’s internal dielectric properties.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting: Once installed, perform a static check. Gently rotate the shaft or use an external oscillator to ensure the monitoring system records a change in voltage proportional to the physical displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh Sensitivity: The 8 mm tip design is the global standard for vibration monitoring, offering an ideal balance between sensitivity and ruggedness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Stability: With an operating range up to +85 deg C, it is suitable for the high-heat environments typical of turbine enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless Compatibility: As a member of the 3300 XL family, it is designed for rapid field replacement, reducing the time required for maintenance outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliability: The ruggedized construction minimizes the risk of signal loss due to physical impact, vibration, or exposure to harsh process chemicals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 330101-00-60-10-02-00 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes factory-calibrated probe head and integrated coaxial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShips in specialized static-safe protective packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull documentation suite for system calibration and troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require periodic recalibration?\u003c\/p\u003e\n\u003cp\u003eIn a standard 3300 XL system, the components are designed for system-wide interchangeability. Recalibration is generally only needed if the target material or cable length is altered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this probe in a hazardous area?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL system has various approvals (ATEX, CSA, etc.). Ensure your specific installation environment is matched to the probe’s certified safety rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the probe tip made of PPS plastic?\u003c\/p\u003e\n\u003cp\u003ePolyphenylene sulfide (PPS) is chemically inert and does not interfere with the electromagnetic eddy-current field required for precise vibration sensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat should I do if my system indicates a \"Not OK\" status?\u003c\/p\u003e\n\u003cp\u003e\"Not OK\" usually signals a discontinuity in the loop. Check the connectors for corrosion, ensure the probe is not grounded, and test the cable for continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I cut the cable to a shorter length?\u003c\/p\u003e\n\u003cp\u003eNever cut the integrated cable. The cable's length and capacitance are precisely tuned to the Proximitor sensor; altering it will cause significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the probe detect position and vibration simultaneously?\u003c\/p\u003e\n\u003cp\u003eThe eddy-current sensor produces a voltage output that reflects the instantaneous distance of the shaft. A DC component represents position, while an AC component represents vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this compatible with 3300 series monitors?\u003c\/p\u003e\n\u003cp\u003eYes, it is designed to be backwards compatible with 3300 series monitoring racks, provided the correct Proximitor is used for the XL series probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the typical service life?\u003c\/p\u003e\n\u003cp\u003eIn a clean environment, these probes are rated for many years of continuous operation; however, high-vibration and high-temperature stress will accelerate wear over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378090336429,"sku":"330101-00-60-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-60-10-02-00-proximity-probes-kmvzv04yvmd.jpg?v=1764225503"},{"product_id":"330101-00-15-10-02-00-bently-nevada-proximity-probe","title":"330101-00-15-10-02-00 Bently Nevada Proximity Probe","description":"\u003cp\u003eConfigured for non-contact displacement measurement in industrial rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-15-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical electrical execution for vibration and axial position monitoring within machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330101-00-15-10-02-00 catalog string defines the transducer's physical and electrical properties. This sequence specifies the probe tip diameter, case thread dimensions, body length, total system length (probe plus extension cable), and the specific connector termination required for integration with the 3300 XL Proximitor sensor module.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-15-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer; powered by Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProportional eddy-current voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer utilizes the eddy-current principle to monitor the air gap between the probe tip and a metallic target. Reliable rotor dynamics analysis necessitates precise gap voltage validation, with a standard target of -10 VDC center-gap. To maintain signal integrity and suppress cross-talk, probes must be installed with adequate physical separation. Any mechanical runout or surface irregularities on the target shaft will be reflected in the transducer output, which must be accounted for during calibration and vibration analysis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-15-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective dust cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product technical manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install probes in non-conductive mounting hardware or ensure electrical isolation from the machine case to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearance: Adhere strictly to radial and axial clearance requirements to prevent probe tip damage and signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Utilize only factory-matched extension cables. Do not modify cable lengths, as the system is calibrated as an integrated assembly (probe, cable, and Proximitor).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the probe body to the machine frame at the mounting bracket to minimize high-frequency noise injection into the Proximitor signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the total system length critical?\u003c\/p\u003e\n\u003cp\u003eA: The 330101 probe system is calibrated as a matched set consisting of the probe, extension cable, and Proximitor sensor. Changing any component length alters system linearity and scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the recommended gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: For standard vibration monitoring, the probe should be adjusted to achieve a gap voltage of approximately -10 VDC at the center of its linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with all Bently Nevada Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: This model is designed for use with the 3300 XL series Proximitor sensors. Ensure the Proximitor is configured for the specific probe type and system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten the probe cable?\u003c\/p\u003e\n\u003cp\u003eA: No. Shortening the cable will invalidate the factory calibration and cause significant errors in the vibration measurement output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I handle probe cross-talk?\u003c\/p\u003e\n\u003cp\u003eA: Maintain minimum separation distances between adjacent probes as specified in the installation documentation to prevent mutual interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the probe tip durable?\u003c\/p\u003e\n\u003cp\u003eA: The tip is constructed from high-performance materials designed to resist chemical exposure and thermal cycling in harsh machine environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What should I check if the gap voltage drifts?\u003c\/p\u003e\n\u003cp\u003eA: Verify that the probe is securely tightened, check the condition of the connectors, and inspect the target surface for any signs of wear or contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the installation complies with the specific hazardous area approval ratings (e.g., ATEX, CSA) assigned to this particular model number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760378541,"sku":"330101-00-15-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-15-10-02-00-proximity-probes-jgx14cpdw5g.jpg?v=1766977001"},{"product_id":"330101-00-16-10-02-00-bently-nevada-3300-xl-proximity-probe","title":"330101-00-16-10-02-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for non-contact displacement measurement in industrial rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-16-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical electrical execution for vibration and axial position monitoring within machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101 catalog string utilizes a precise matrix to define the transducer configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 8 mm Probe without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length (0.0 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16\u003c\/strong\u003e: Overall case length (160 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total system length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector type (Miniature coaxial connector with protective connector cover).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (Not required\/Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration provides a linear range of 2.0 mm with a standard scale factor of 7.87 V\/mm, calibrated for AISI 4140 steel targets.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-16-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer; powered by Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProportional eddy-current voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer utilizes the eddy-current principle to monitor the air gap between the probe tip and a metallic target. Reliable rotor dynamics analysis necessitates precise gap voltage validation, with a standard target of -10 VDC center-gap. To maintain signal integrity and suppress cross-talk, probes must be installed with adequate physical separation. Any mechanical runout or surface irregularities on the target shaft will be reflected in the transducer output, which must be accounted for during calibration and vibration analysis.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-16-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective dust cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install probes in non-conductive mounting hardware or ensure electrical isolation from the machine case to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearance: Adhere strictly to radial and axial clearance requirements to prevent probe tip damage and signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Utilize only factory-matched extension cables. Do not modify cable lengths, as the system is calibrated as an integrated assembly (probe, cable, and Proximitor).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the probe body to the machine frame at the mounting bracket to minimize high-frequency noise injection into the Proximitor signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the total system length critical?\u003c\/p\u003e\n\u003cp\u003eA: The 330101 probe system is calibrated as a matched set consisting of the probe, extension cable, and Proximitor sensor. Changing any component length alters system linearity and scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the recommended gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: For standard vibration monitoring, the probe should be adjusted to achieve a gap voltage of approximately -10 VDC at the center of its linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with all Bently Nevada Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: This model is designed for use with the 3300 XL series Proximitor sensors. Ensure the Proximitor is configured for the specific probe type and system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten the probe cable?\u003c\/p\u003e\n\u003cp\u003eA: No. Shortening the cable will invalidate the factory calibration and cause significant errors in the vibration measurement output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I handle probe cross-talk?\u003c\/p\u003e\n\u003cp\u003eA: Maintain minimum separation distances between adjacent probes as specified in the installation documentation to prevent mutual interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the probe tip durable?\u003c\/p\u003e\n\u003cp\u003eA: The tip is constructed from high-performance materials designed to resist chemical exposure and thermal cycling in harsh machine environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What should I check if the gap voltage drifts?\u003c\/p\u003e\n\u003cp\u003eA: Verify that the probe is securely tightened, check the condition of the connectors, and inspect the target surface for any signs of wear or contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the installation complies with the specific hazardous area approval ratings (e.g., ATEX, CSA) assigned to this particular model number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760411309,"sku":"330101-00-16-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-16-10-02-00-proximity-probes-adee5132x2t.jpg?v=1766977002"},{"product_id":"330101-00-19-10-02-00-bently-nevada-proximity-probe-3300-xl-8mm","title":"330101-00-19-10-02-00 Bently Nevada Proximity Probe 3300 XL 8mm","description":"\u003cp\u003eConfigured for non-contact displacement measurement in industrial rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-19-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical electrical execution for vibration and axial position monitoring within machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101 catalog string utilizes a precise matrix to define the transducer configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 8 mm Probe without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length (0.0 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e19\u003c\/strong\u003e: Overall case length (190 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total system length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector type (Miniature coaxial connector with protective connector cover).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (Not required\/Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration provides a linear range of 2.0 mm with a standard scale factor of 7.87 V\/mm, calibrated for AISI 4140 steel targets.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-19-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer; powered by Proximitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProportional eddy-current voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer utilizes the eddy-current principle to monitor the air gap between the probe tip and a metallic target. Reliable rotor dynamics analysis necessitates precise gap voltage validation, with a standard target of -10 VDC center-gap. To maintain signal integrity and suppress cross-talk, probes must be installed with adequate physical separation. Any mechanical runout or surface irregularities on the target shaft will be reflected in the transducer output, which must be accounted for during calibration and vibration analysis.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-19-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective dust cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install probes in non-conductive mounting hardware or ensure electrical isolation from the machine case to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearance: Adhere strictly to radial and axial clearance requirements to prevent probe tip damage and signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Utilize only factory-matched extension cables. Do not modify cable lengths, as the system is calibrated as an integrated assembly (probe, cable, and Proximitor).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the probe body to the machine frame at the mounting bracket to minimize high-frequency noise injection into the Proximitor signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the total system length critical?\u003c\/p\u003e\n\u003cp\u003eA: The 330101 probe system is calibrated as a matched set consisting of the probe, extension cable, and Proximitor sensor. Changing any component length alters system linearity and scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the recommended gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: For standard vibration monitoring, the probe should be adjusted to achieve a gap voltage of approximately -10 VDC at the center of its linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with all Bently Nevada Proximitors?\u003c\/p\u003e\n\u003cp\u003eA: This model is designed for use with the 3300 XL series Proximitor sensors. Ensure the Proximitor is configured for the specific probe type and system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten the probe cable?\u003c\/p\u003e\n\u003cp\u003eA: No. Shortening the cable will invalidate the factory calibration and cause significant errors in the vibration measurement output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I handle probe cross-talk?\u003c\/p\u003e\n\u003cp\u003eA: Maintain minimum separation distances between adjacent probes as specified in the installation documentation to prevent mutual interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the probe tip durable?\u003c\/p\u003e\n\u003cp\u003eA: The tip is constructed from high-performance materials designed to resist chemical exposure and thermal cycling in harsh machine environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What should I check if the gap voltage drifts?\u003c\/p\u003e\n\u003cp\u003eA: Verify that the probe is securely tightened, check the condition of the connectors, and inspect the target surface for any signs of wear or contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the installation complies with the specific hazardous area approval ratings (e.g., ATEX, CSA) assigned to this particular model number.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760444077,"sku":"330101-00-19-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-19-10-02-00-proximity-probes-ranbgrftk0b.jpg?v=1766977005"},{"product_id":"330101-00-20-10-02-05-bently-nevada-3300-xl-8-mm-eddy-current-proximity-probe","title":"330101-00-20-10-02-05 Bently Nevada 3300 XL 8 mm Eddy-Current Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-20-10-02-05 is an 8 mm eddy-current proximity probe used to measure shaft displacement without contact. Installed at bearings or thrust locations, it produces a displacement signal that is processed by a compatible Proximitor sensor and monitoring platform to support machinery protection and condition monitoring.\u003c\/p\u003e\n\u003cp\u003eThis probe is selected when stable vibration and position measurements are required in rotating equipment environments. When used as part of a complete 3300 XL transducer system (probe, extension cable, and Proximitor), it supports reliable trending of radial vibration and axial position to help identify developing faults before they lead to forced outages.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e330101-00-20-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.0 in (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e2.0 in (Option 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m \/ 3.3 ft (Option 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Style\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with protector (Option 02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals (Option Dependent)\u003c\/td\u003e\n\u003ctd\u003eMulti-agency package, commonly including ATEX \/ IECEx \/ CSA (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional technical notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe probe is not powered as a standalone device; excitation and signal conditioning are provided by the Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal system calibration depends on matching probe type, extension cable length (if used), and Proximitor model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe mention of a “3500 rack receiving the signal” is system-level; the probe itself is compatible with appropriate Bently Nevada proximity systems when matched correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cp\u003eTypical installation scenarios include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines for continuous bearing vibration and thrust position supervision (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors where shaft motion trending supports protection logic and reliability programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical process pumps and motor-driven trains where early vibration changes indicate bearing wear or hydraulic instability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and oil \u0026amp; gas rotating assets where temperature variation and lubricant exposure demand stable transducer performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSet and verify probe gap per site procedures to avoid saturation and maintain linear response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain cable routing practices that reduce EMI pickup, especially near VFDs and high-current conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm steady transducer “OK” status after installation to validate the probe\/cable\/sensor signal path\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760476845,"sku":"330101-00-20-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-20-10-02-05-proximity-probes-pr20ihsfx01.jpg?v=1769753243"},{"product_id":"330101-00-30-50-02-00-bently-nevada-3300-xl-series-proximity-probe","title":"330101-00-30-50-02-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eBently Nevada 330101-00-30-50-02-00\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ealso cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e330101\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a dedicated hardware component for non-contacting vibration and position measurement within rotating machinery monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e330101\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL 8 mm Proximity Probe,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3\/8-24 thread,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewithout armor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e00\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnthreaded Length Option (00 mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e30\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTotal Case Length Option (3.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 meters).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e50\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTotal Length Option (5.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 meters).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e02\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAgency Approval Option (Multiple approvals:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCSA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eATEX,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIECEx).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e00\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInternal Mounting Thread\/Connection Style (Standard mount).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-30-50-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 18 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNegligible (Passive sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to the target displacement.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProper installation requires gap voltage validation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhere the target operational gap typically centers on a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRotor dynamics analysis,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as shaft centerline and orbital vibration monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edepends on the phase-coherent signal transmission through the extension cable and Proximitor sensor.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCross-talk suppression is maintained through high-frequency shielding,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing interference when multiple probes are installed in close proximity on the same machine casing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eOrdering and Packaging\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eOne (1) 330101-00-30-50-02-00 Proximity Probe\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eOne (1) Threaded locknut with safety wire holes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eOne (1) Connector protector (pre-installed)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 class=\"\"\u003eInstallation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eProbe Mounting:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the probe is mounted in a bracket that prevents mechanical resonance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum distance from other probes to avoid cross-talk.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eGap Setting:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAdjust the probe-to-target gap to achieve a -10 VDC reading when the machine is at rest or at the center of the mechanical range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eCabling:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUse only Bently Nevada specified extension cables to maintain system impedance.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRoute cables away from high-voltage AC lines to minimize electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eTermination:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSecure the connector using the provided protector to ensure ingress protection and prevent accidental disconnection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eWhat is the nominal scale factor of this probe?\u003c\/span\u003e\u003cspan class=\"\"\u003eThe nominal scale factor is 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e87 V\/mm (200 mV\/mil) for the 3300 XL system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eCan this probe be used in hazardous areas?\u003c\/span\u003e\u003cspan class=\"\"\u003eYes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 02 suffix indicates it is designed for use in hazardous environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprovided it is connected to an appropriately certified intrinsic safety barrier.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the purpose of the connector protector?\u003c\/span\u003e\u003cspan\u003eIt prevents oil and dirt ingress into the coaxial connector,\u003c\/span\u003e\u003cspan\u003e ensuring the signal integrity of the high-frequency carrier wave.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDoes the probe require a specific Proximitor model?\u003c\/span\u003e\u003cspan\u003eThis 8 mm probe is designed specifically for use with the 3300 XL Proximitor sensor; mismatching components will invalidate the system linearity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHow should the probe be grounded?\u003c\/span\u003e\u003cspan\u003eThe system is typically grounded at the monitor rack; ensure the probe case is electrically isolated from the machine housing if ground loops are identified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the impact of cable length on output?\u003c\/span\u003e\u003cspan\u003eThe system is calibrated for a specific total length (3.\u003c\/span\u003e\u003cspan\u003e0 meters).\u003c\/span\u003e\u003cspan\u003e Altering this length will shift the calibration and introduce measurement errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCan this sensor measure non-ferrous targets?\u003c\/span\u003e\u003cspan\u003eThe sensitivity will change based on the target material's conductivity and permeability.\u003c\/span\u003e\u003cspan\u003e Calibration must be performed for specific alloys.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHow do I verify if the probe is functioning correctly?\u003c\/span\u003e\u003cspan\u003ePerform a static gap check with a digital multimeter to verify the -10 VDC output at the specified center gap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760509613,"sku":"330101-00-30-50-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-30-50-02-00-proximity-probes-4oin4embpob.jpg?v=1766977007"},{"product_id":"330101-00-36-10-01-00-bently-nevada-3300-xl-series-proximity-probe","title":"330101-00-36-10-01-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-36-10-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal generation based on shaft surface proximity to the transducer tip.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length Option (00 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e36\u003c\/strong\u003e: Total Case Length Option (3.6 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval Option (CSA, ATEX, IECEx for hazardous areas).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting Thread\/Connection Style (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-36-10-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 cm x 15 cm x 8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system requires precise eddy-current probe scaling to convert target distance into a proportional voltage signal. Operators must ensure gap voltage validation, targeting a -10 VDC setpoint within the 2 mm linear range to maintain accuracy. Rotor dynamics parameters, such as vibration amplitude and shaft position, are output through the Proximitor sensor. Cross-talk suppression is achieved by observing minimum spacing requirements between adjacent probes to prevent high-frequency carrier wave interference on the coaxial cable.\u003c\/p\u003e\n\u003ch3\u003eOrdering and Packaging\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-36-10-01-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Threaded locknut with safety wire holes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eInstallation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Thread the probe into the mounting bracket. Ensure at least 5 threads of engagement if using NPT interfaces, though standard 3\/8-24 threads require firm locking via the jam nut.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the coaxial cable is not routed alongside high-power AC cables to prevent inductive noise injection into the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain electrical isolation between the probe case and the machine housing if required by the monitoring system design to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration: Perform a static calibration check against the target material to ensure the scale factor remains within 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the frequency response of this probe?\u003c\/p\u003e\n\u003cp\u003eThe probe responds from 0 Hz to 10 kHz, ensuring accurate capture of both static gap position and dynamic vibration frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe cable be shortened in the field?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for a specific total length. Cutting or splicing the cable alters the system impedance and invalidates the signal linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip touches the rotor?\u003c\/p\u003e\n\u003cp\u003ePhysical contact may damage the plastic tip material and affect the eddy-current field, potentially leading to signal distortion or permanent transducer failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I check the probe for internal damage?\u003c\/p\u003e\n\u003cp\u003eUse an ohmmeter to measure the resistance between the center conductor and the shield; a short or open circuit indicates internal failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with all 3300 series monitors?\u003c\/p\u003e\n\u003cp\u003eIt is optimized for the 3300 XL Proximitor sensor; verify that the monitor interface card is configured for 8 mm probe input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material is required for the target?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for AISI 4140 steel. Using other materials requires re-calibration or the use of correction factors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the connector protector?\u003c\/p\u003e\n\u003cp\u003eIt prevents contamination by oil and moisture, which could otherwise cause signal impedance fluctuations in the coaxial connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require a specific installation torque?\u003c\/p\u003e\n\u003cp\u003eApply standard torque recommended for 3\/8-24 hardware, ensuring the probe remains stationary during machine operation under vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760542381,"sku":"330101-00-36-10-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-36-10-01-00-proximity-probes-bn0oupcut14.jpg?v=1766977008"},{"product_id":"330101-00-50-20-02-05-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330101-00-50-20-02-05 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-50-20-02-05 is an eddy-current proximity probe from the 3300 XL 8 mm transducer family. It is used for non-contact displacement measurement between the probe tip and a rotating shaft or other metallic target. When combined with a matched Proximitor sensor (and extension cable if required by the system design), the probe provides continuous signals for radial vibration and\/or axial position monitoring in machinery protection and condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThis probe configuration is commonly selected for installations that require stable measurement performance in industrial environments, supporting early identification of mechanical issues such as rotor unbalance, misalignment, rub conditions, and bearing wear.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel \/ Order Code: 330101-00-50-20-02-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Series: 3300 XL 8 mm Proximity Transducer System\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Eddy-current proximity probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement: Shaft displacement for vibration and\/or position (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Tip Diameter: 8 mm (family characteristic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Thread: 3\/8-24 UNF (typical for this probe family)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded Length: 0.0 in (Option 00)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCase Length: Option 50 (long case configuration, per ordering code)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Length: Option 20 (integral cable length per ordering code)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: Miniature coaxial ClickLoc with connector protector (Option 02)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprovals: Multi-agency option package (Option 05, application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -51°C to +177°C (typical 3300 XL specification range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eIntegration Notes\u003c\/th\u003e\n\u003cth\u003eGuidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Matching\u003c\/td\u003e\n\u003ctd\u003eProbe must be paired with the correct Proximitor sensor and total system length to maintain calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eSet probe gap per site procedures to remain within the linear operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Quality\u003c\/td\u003e\n\u003ctd\u003eRoute and shield transducer wiring properly to minimize EMI and false indications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eTypical operational deployments include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines for bearing vibration monitoring and rotor dynamic observation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors where continuous displacement data supports protection logic and reliability programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge pumps and motor-driven trains where shaft motion trends indicate bearing or hydraulic issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGear-driven equipment and high-speed rotating assets requiring stable non-contact measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit and spares where maintaining compatibility with 3300 XL 8 mm systems is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOperational considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify mechanical installation dimensions for the selected case length option before installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm cable routing and connector engagement to prevent intermittent readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform channel verification at the monitor\/controller to ensure consistent “OK” status and correct scaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760575149,"sku":"330101-00-50-20-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-50-20-02-cn-proximity-probes-4zzkwkqcfji.jpg?v=1769753409"},{"product_id":"330101-00-63-10-02-00-bently-nevada-3300-xl-series-proximity-probe","title":"330101-00-63-10-02-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-63-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal generation based on shaft surface proximity to the transducer tip.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length Option (00 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e63\u003c\/strong\u003e: Total Case Length Option (6.3 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting Thread\/Connection Style (Standard mount).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-63-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 20 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to target displacement. Proper installation requires gap voltage validation, where the target operational gap typically centers on a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Rotor dynamics analysis, such as shaft centerline and orbital vibration monitoring, depends on the phase-coherent signal transmission through the extension cable and Proximitor sensor. Cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple probes are installed in close proximity on the same machine casing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-63-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Threaded locknut with safety wire holes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Stability: Secure the probe using the provided locknut. Ensure the bracket is sufficiently rigid to prevent mechanical resonance at machine operating frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Adjustment: Measure the gap voltage during installation. Adjust the probe position until a reading of -10 VDC is achieved at the nominal shaft position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Keep coaxial cables away from high-current AC lines or variable frequency drive cables to minimize induced electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImpedance Matching: Ensure the total length of the probe and extension cable matches the calibrated length for the specific Proximitor sensor being utilized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal scale factor of this probe?\u003c\/p\u003e\n\u003cp\u003eThe nominal scale factor for the 3300 XL 8 mm system is 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eThe 02 suffix denotes compliance with standard hazardous area certifications, including ATEX and IECEx, provided appropriate safety barriers are used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the connector protector important?\u003c\/p\u003e\n\u003cp\u003eIt provides environmental sealing for the coaxial connector, preventing moisture and contaminants from impacting signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I perform a field check?\u003c\/p\u003e\n\u003cp\u003eUse a digital voltmeter to verify the gap voltage at the monitor or Proximitor output; ensure it remains within the linear range of -1 VDC to -18 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe require an armored cable?\u003c\/p\u003e\n\u003cp\u003eThis specific model (00 suffix) does not feature internal armor; it should be installed in protective conduit if subjected to physical impact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe detect non-conductive materials?\u003c\/p\u003e\n\u003cp\u003eNo, the eddy-current principle relies on the conductivity and magnetic permeability of the target, typically AISI 4140 steel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the gap voltage is outside the linear range?\u003c\/p\u003e\n\u003cp\u003eThe output signal becomes non-linear or saturates, leading to inaccurate vibration readings and potential alarm faults in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a faulty probe?\u003c\/p\u003e\n\u003cp\u003eDisconnect the probe and measure continuity; if the center conductor is open or shorted to the shield, the internal coil or cable is damaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760607917,"sku":"330101-00-63-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-63-10-02-00-proximity-probes-iackvt0oi04.jpg?v=1766977012"},{"product_id":"330101-24-35-10-02-00-bently-nevada-proximity-probe-3300-xl-series","title":"330101-24-35-10-02-00 Bently Nevada Proximity Probe 3300 XL Series","description":"\u003cp\u003eConfigured for non-contacting displacement measurement in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-24-35-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal generation based on shaft surface proximity to the transducer tip.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330101\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 3\/8-24 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e24\u003c\/strong\u003e: Unthreaded Length Option (24 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e35\u003c\/strong\u003e: Total Case Length Option (35 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting Thread\/Connection Style (Standard mount).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-24-35-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.40 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 18 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes precise eddy-current probe scaling to ensure linear voltage output corresponding to target displacement. Successful deployment requires gap voltage validation, where the operational gap is typically adjusted to reach a -10 VDC setpoint to maintain linearity within the 2 mm transducer range. Rotor dynamics monitoring depends on the phase-coherent signal transmission through the coaxial cable to the Proximitor sensor. Furthermore, cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple probes are installed in confined machine housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-24-35-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Threaded locknut with safety wire holes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Mounting: Thread the probe into the mounting bracket; ensure at least 5 threads of engagement if using NPT adapters or standard 3\/8-24 jam nut security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Adjust the probe to a gap resulting in -10 VDC output at the nominal shaft position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Path: Ensure the coaxial extension cable is routed away from high-voltage lines or power cables to prevent induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Integrity: Always install the provided connector protector to prevent oil or debris ingress, which can alter electrical impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal scale factor of this probe?\u003c\/p\u003e\n\u003cp\u003eThe nominal scale factor for the 3300 XL 8 mm system is 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous environments?\u003c\/p\u003e\n\u003cp\u003eYes, the 02 suffix indicates it is rated for use in hazardous areas, provided it is connected to a certified intrinsic safety barrier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the 24 mm unthreaded length signify?\u003c\/p\u003e\n\u003cp\u003eIt represents the length of the probe case that does not feature external threads, typically used for specific mounting depth requirements in machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe compatible with 3500 series monitors?\u003c\/p\u003e\n\u003cp\u003eThis probe is compatible with the 3300 XL Proximitor; the output from the Proximitor is then processed by the 3500 series vibration monitoring cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify signal integrity?\u003c\/p\u003e\n\u003cp\u003ePerform a static gap test by measuring the voltage between the center conductor and the shield at the Proximitor terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be trimmed to fit a specific distance?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for a 1.0 meter total length; cutting the cable will alter the system impedance and signal linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat material should the target be?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for AISI 4140 steel; other materials may require a recalibration factor to ensure measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify if the probe is functioning?\u003c\/p\u003e\n\u003cp\u003eA healthy probe will exhibit a specific capacitance and resistance; use a multimeter to ensure no short or open circuits exist between the center conductor and the case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760640685,"sku":"330101-24-35-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-24-35-10-02-00-proximity-transducer-c3bwfhkatai.jpg?v=1766977013"},{"product_id":"330101-37-57-10-02-05-bently-nevada-3300-xl-8-mm-eddy-current-proximity-probe","title":"330101-37-57-10-02-05 Bently Nevada 3300 XL 8 mm Eddy-Current Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-37-57-10-02-05 is an 8 mm eddy-current proximity probe from the 3300 XL transducer family, intended for non-contact measurement of shaft displacement on rotating machinery. The probe generates a displacement signal proportional to the distance between the probe tip and a conductive target. When used with a compatible Proximitor sensor (and extension cable when applicable), it supports continuous monitoring of radial vibration and position-related parameters for machinery protection and condition monitoring programs.\u003c\/p\u003e\n\u003cp\u003eThis probe configuration is typically selected when longer mechanical reach is needed to suit specific bearing housing or bracket geometries, while maintaining the measurement stability expected from 3300 XL proximity systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e330101-37-57-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e3.7 in (Option 37)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e5.7 in (Option 57)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m \/ 3.3 ft (Option 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with protector (Option 02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals (Option Dependent)\u003c\/td\u003e\n\u003ctd\u003eMulti-agency hazardous area package (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTechnical corrections and notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e“System Accuracy ±0.75% velocity” is not applicable to a proximity displacement probe. Proximity probes measure displacement; velocity accuracy statements apply to seismic velocity sensors or derived calculations in monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency response, linear range, and calibration depend on the complete transducer system (probe + cable + Proximitor) and the target material. Confirm compatibility with the selected monitor input requirements during engineering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eCommon deployment scenarios include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines for continuous bearing vibration monitoring and rotor behavior assessment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors where displacement trending supports protection logic and early fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge pumps and motor-driven trains where increasing vibration often indicates bearing wear, looseness, or hydraulic instability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed fans and gear-driven equipment requiring stable non-contact sensing in oil-contaminated or high-vibration areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous-area installations where certified transducer hardware is required by site compliance standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify probe mounting depth and clearances for the longer case configuration before installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSet probe gap per site procedures to ensure operation within the linear measurement region\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep transducer wiring separated from high-current conductors and VFD outputs to reduce EMI-related noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760673453,"sku":"330101-37-57-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-37-57-10-02-05-8mm-proximity-probes-wftz02p2snu.jpg?v=1766977014"},{"product_id":"330103-00-03-10-01-00-bently-nevada-extension-cable-3300-xl-series","title":"330103-00-03-10-01-00 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-03-10-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between 8 mm proximity probes and Proximitor sensors within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL Extension Cable, standard construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Cable Length Option (3.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting\/Connector Option (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-03-10-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 15 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (High-frequency signal transmission)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, 75 ohm characteristic impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system requires precise eddy-current probe scaling to ensure linear output relative to the target displacement. Proper installation requires gap voltage validation, where the system is calibrated to specific lengths to maintain the integrity of the -10 VDC setpoint. Rotor dynamics analysis, such as shaft centerline and orbital vibration monitoring, depends on the phase-coherent signal transmission through the extension cable to the Proximitor. Cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple cables are bundled in conduit or cable trays.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-03-10-01-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector (installed on probe-end connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install in dedicated electrical conduit where possible. Avoid bundling with high-power AC cables to minimize induction of electromagnetic noise into the high-frequency carrier signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBending Radius: Maintain a minimum bend radius of 25 mm to prevent stress on the coaxial dielectric and potential impedance fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnections: Tighten connectors to the recommended torque specifications using the appropriate tool. Ensure all connections are fully seated to prevent ingress of moisture or oil.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector; do not ground the shield at multiple points, as this can create ground loops that distort vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be cut to a shorter length?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for specific total lengths. Altering the cable length changes the impedance and phase characteristics, leading to measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the connector protector?\u003c\/p\u003e\n\u003cp\u003eIt seals the coaxial connection against oil, moisture, and debris, which prevents signal degradation and potential drift in the gap voltage measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with non-XL Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is designed for 3300 XL system components; using it with older systems will invalidate the linearity and accuracy specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify a good connection?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance multimeter to check for open or short circuits between the center conductor and the shield before finalizing the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable have an armor option?\u003c\/p\u003e\n\u003cp\u003eThe 00 suffix in this specific model indicates no internal armor; for mechanical protection, route the cable inside rigid or flexible electrical conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be used in vacuum environments?\u003c\/p\u003e\n\u003cp\u003eYes, the materials used are suitable for high-temperature and vacuum applications, provided the assembly is properly installed and sealed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impedance of the coaxial cable?\u003c\/p\u003e\n\u003cp\u003eThe cable is designed with a characteristic impedance of 75 ohm to match the 3300 XL system architecture and minimize signal reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I secure the cable?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties at regular intervals to prevent mechanical vibration of the cable itself, which can introduce motion-related signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760706221,"sku":"330103-00-03-10-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-03-10-01-00-3300-xl-8-mm-proximity-cable-ffeea23mnuj.jpg?v=1766977015"},{"product_id":"330103-00-03-10-02-05-bently-nevada-3300-xl-series-extension-cable","title":"330103-00-03-10-02-05 Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eConfigured for high-frequency signal transmission in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-03-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical electrical coupling between 8 mm proximity probes and Proximitor sensors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Cable Length Option (3.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total System Length Option (1.0 meter added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Internal Mounting\/Connector Option (Connector with protector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-03-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 cm x 18 cm x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Signal loss determined by cable length)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to target displacement. Proper installation requires gap voltage validation, where the target operational gap typically centers on a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Rotor dynamics analysis, such as shaft centerline and orbital vibration monitoring, depends on the phase-coherent signal transmission through the extension cable and Proximitor sensor. Cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple cables are installed in close proximity on the same machine casing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-03-10-02-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector (installed on probe-end connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install within dedicated electrical conduit to protect the coaxial cable from physical damage and electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBending Radius: Adhere to a minimum bend radius of 25 mm. Sharp bends can permanently deform the coaxial dielectric and alter signal impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnections: Tighten connectors firmly; ensure the connector protector is fully engaged to prevent moisture and oil ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Maintain continuous shielding from probe to monitor. Do not create multiple grounds, as this introduces ground loops that degrade vibration data quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be used with non-XL 3300 series components?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is specifically engineered for the 3300 XL system; impedance mismatches with older 3300 series components will cause signal distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of cable length mismatch?\u003c\/p\u003e\n\u003cp\u003eThe system is factory-calibrated for a specific total length. A mismatch alters the phase and frequency response, necessitating system re-calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable have internal armor?\u003c\/p\u003e\n\u003cp\u003eThe 00 suffix denotes standard construction without internal armor; for harsh environments, use external rigid or flexible conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I splice this cable?\u003c\/p\u003e\n\u003cp\u003eNo. Splicing introduces impedance discontinuities and significantly degrades high-frequency signal integrity. Replace the cable if damaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the 05 suffix indicate?\u003c\/p\u003e\n\u003cp\u003eThe 05 indicates the connector includes a factory-installed protector, essential for maintaining signal integrity in oily or humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable compatible with vacuum applications?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are rated for vacuum environments, provided the assembly is properly installed and the connectors are sealed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I test the cable for continuity?\u003c\/p\u003e\n\u003cp\u003eUse a multimeter to measure the resistance of the center conductor and ensure there is no short to the outer shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is 75 ohm impedance specified?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for 75 ohm coaxial cable to ensure optimal matching of the high-frequency carrier wave generated by the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760738989,"sku":"330103-00-03-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-03-10-02-05-3300-xl-cable-ubbreicfspl.jpg?v=1766977016"},{"product_id":"330103-00-04-10-02-00-bently-nevada-extension-cable-3300-xl-series","title":"330103-00-04-10-02-00 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-04-10-02-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between 8 mm proximity probes and Proximitor sensors within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Cable Length Option (4.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total Length Option (1.0 meter added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting\/Connector Option (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-04-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 18 cm x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, 75 ohm characteristic impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system requires precise eddy-current probe scaling to convert target displacement into a proportional voltage signal. Operators must ensure gap voltage validation, targeting a -10 VDC setpoint within the linear range of the transducer. Rotor dynamics analysis, specifically orbital vibration and shaft centerline monitoring, depends on the phase-coherent signal transmission through the extension cable to the Proximitor sensor. Cross-talk suppression is achieved by observing minimum spacing requirements between adjacent probes, preventing interference on the high-frequency carrier wave.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-04-10-02-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install in rigid or flexible electrical conduit. Avoid routing alongside high-power AC lines to prevent inductive noise injection into the coaxial signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25 mm. Exceeding this limit will deform the internal dielectric and degrade high-frequency transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Torque: Tighten connectors to the recommended torque using appropriate tools. Ensure connections are fully seated to maintain environmental seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector. Do not create multiple ground points, which can introduce ground loops and signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be shortened?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for specific total lengths. Cutting the cable shifts the impedance and phase characteristics, causing measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the connector protector?\u003c\/p\u003e\n\u003cp\u003eIt prevents ingress of oil, moisture, and contaminants into the coaxial connector, ensuring the signal remains stable in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with 3300 series components?\u003c\/p\u003e\n\u003cp\u003eIt is designed for the 3300 XL system; using it with older 3300 series Proximitor sensors may lead to non-linear output and accuracy loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a damaged cable?\u003c\/p\u003e\n\u003cp\u003eUse an ohmmeter to check for continuity. Short or open circuits between the center conductor and the shield indicate internal failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable require specific grounding?\u003c\/p\u003e\n\u003cp\u003eThe cable shield should be grounded at the monitor rack; avoid grounding the cable at the probe end to prevent potential ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I secure the cable in the field?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties to secure the cable at regular intervals to prevent mechanical vibration, which can cause spurious signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable withstand high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eYes, it is rated for continuous operation up to 177 deg C, assuming the cable assembly is installed in a properly ventilated or shielded location.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the cable impedance 75 ohm?\u003c\/p\u003e\n\u003cp\u003eThe 75 ohm impedance matches the 3300 XL system architecture to prevent signal reflections and maintain the fidelity of the high-frequency carrier signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760771757,"sku":"330103-00-04-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-04-10-02-00-proximity-probes-k12lliiwgo3.jpg?v=1766977019"},{"product_id":"330103-00-04-50-11-00-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330103-00-04-50-11-00 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330103-00-04-50-11-00 is an 8 mm eddy-current proximity probe designed for non-contact displacement measurement on rotating machinery. Used within the 3300 XL 8 mm proximity transducer system, it measures the gap between the probe tip and a conductive target (typically a shaft), enabling continuous monitoring of shaft vibration and axial position when paired with a compatible Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eThis configuration is commonly selected for metric machine hardware because it uses an M10 × 1 mounting thread. The integrated long cable option supports installations where the sensor routing distance is extended, while maintaining signal integrity required for machinery protection and condition monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e330103-00-04-50-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eM10 × 1 (metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e40 mm (Option 04)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.0 m \/ 16.4 ft (Option 50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with protective boot (Option 11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals (Option Dependent)\u003c\/td\u003e\n\u003ctd\u003eMulti-agency hazardous area option set (as specified by “-00” or site BOM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Scale Factor (System Dependent)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil), when used with the matched Proximitor system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTechnical corrections and notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIP67 \/ NEMA 4X ratings are not typically specified for proximity probes installed within machine housings and conduit systems; environmental protection depends on the installed assembly, connectors, and routing methods. Use cabinet and junction box practices appropriate to site standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinear range and calibration depend on the complete transducer system (probe + cable + Proximitor) and target material. Confirm compatibility with the monitor input requirements during engineering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eCommon operating environments include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines where continuous shaft displacement data supports vibration limits and protection logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors in oil, gas, and petrochemical services requiring stable proximity signals for reliability programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge pumps and motor-driven trains where displacement trending indicates bearing wear, looseness, or hydraulic instability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM packaged skids and international equipment builds favoring metric mounting threads and longer cable routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify mechanical fit for the 40 mm case and confirm adequate clearance for probe adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSet probe gap per commissioning procedure to remain within the intended linear operating region\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the 5 m cable away from VFD outputs and high-current conductors; follow shielding and grounding practices to minimize EMI pickup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760804525,"sku":"330103-00-04-50-11-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-04-50-11-00-advanced-probe-kl04s4ccrve.jpg?v=1766977020"},{"product_id":"330103-00-05-15-02-cn-bently-nevada-3300-xl-series-extension-cable","title":"330103-00-05-15-02-CN Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-05-15-02-CN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for high-frequency signal transmission between 8 mm proximity probes and Proximitor sensors within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Cable Length Option (5.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15\u003c\/strong\u003e: Total System Length Option (1.5 meters added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple approvals: CSA, ATEX, IECEx).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Country-specific identification (China).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-05-15-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\/China Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 cm x 18 cm x 8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm characteristic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to target displacement. Proper installation requires gap voltage validation, where the target operational gap typically centers on a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Rotor dynamics analysis, such as shaft centerline and orbital vibration monitoring, depends on the phase-coherent signal transmission through the extension cable and Proximitor sensor. Cross-talk suppression is maintained through high-frequency shielding, preventing interference when multiple cables are installed in close proximity within machinery conduit.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-05-15-02-CN Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install within dedicated electrical conduit. Maintain separation from high-voltage AC lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Adhere to a minimum bend radius of 25 mm. Excessive bending degrades the coaxial dielectric and impairs signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque Specifications: Tighten connectors to manufacturer-recommended torque values. Ensure all connections are fully seated to prevent ingress of contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain shield continuity from the probe to the monitor. Avoid multiple ground points to prevent ground loops and signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be shortened in the field?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for specific lengths. Cutting the cable changes the impedance and phase characteristics, resulting in measurement inaccuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the connector protector?\u003c\/p\u003e\n\u003cp\u003eIt provides an environmental seal against oil, moisture, and debris, preserving the high-frequency carrier wave signal from degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with non-XL 3300 Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is optimized for the 3300 XL architecture; impedance mismatches with older systems will invalidate accuracy specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify internal cable damage?\u003c\/p\u003e\n\u003cp\u003eUse a multimeter to measure the center conductor and shield; open or short circuits indicate a damaged coaxial assembly that must be replaced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable have internal armor?\u003c\/p\u003e\n\u003cp\u003eThe 00 suffix indicates standard construction without armor. For high-impact areas, route the cable through armored flexible or rigid conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan it be used in vacuum applications?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are suitable for vacuum environments, provided the assembly is properly installed and the connector seal is maintained.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I secure the cable?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic ties at regular intervals to prevent mechanical vibration, which can induce noise in the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat defines the 75 ohm impedance?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL system is specifically calibrated for 75 ohm coaxial cable to ensure optimal matching of the high-frequency signal generated by the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760837293,"sku":"330103-00-05-15-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-05-15-02-cn-proximity-transducer-uixdcf4kiem.jpg?v=1766977021"},{"product_id":"330103-00-06-05-02-cn-bently-nevada-extension-cable-3300-xl-series","title":"330103-00-06-05-02-CN Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eConfigured for high-frequency signal transmission in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-06-05-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical and electrical execution of probe-to-sensor connectivity.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard coaxial extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: Cable Length Option (6.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total System Length Option (0.5 meters added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple international approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Country-specific identification (China).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-06-05-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\/China Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.40 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 20 cm x 8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system requires precise eddy-current probe scaling to ensure linear output relative to the target displacement of the monitored machine shaft. Operators must perform gap voltage validation, targeting a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Proper rotor dynamics analysis, including orbital vibration and shaft centerline, relies on the phase-coherent signal transmission through the extension cable to the Proximitor sensor. Effective cross-talk suppression is achieved by observing strict conduit routing standards to prevent interference on the high-frequency carrier signal generated by the system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-06-05-02-CN Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install within dedicated electrical conduit to shield the coaxial path from electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25 mm. Sharp radii deform the internal dielectric and alter impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Tighten coaxial connectors securely. Ensure the connector protector is correctly seated to prevent oil or moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector. Avoid multiple ground points to prevent ground loops that introduce measurement noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be trimmed to match specific installation needs?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for defined lengths. Modifying the cable length alters impedance and phase, leading to invalid vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a damaged connector?\u003c\/p\u003e\n\u003cp\u003eDamage to the connector degrades the signal-to-noise ratio and can cause drift in the gap voltage measurement. Replace the assembly if the connector is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe cable is a passive component. While it can be disconnected from the Proximitor, ensure the channel is in a maintenance mode to avoid triggering false alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is 75 ohm impedance specified?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL architecture is impedance-matched to 75 ohm to ensure maximum fidelity and minimal signal reflection of the high-frequency carrier wave.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable suitable for use in vacuum environments?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are rated for vacuum conditions provided the connections are fully seated and sealed against environmental ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I test for cable continuity?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance multimeter to verify the center conductor and outer shield continuity; ensure no shorts exist between the conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be used with older 3300 series Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is specifically engineered for the 3300 XL system. Use with older series components leads to non-linear signal responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent signal interference when bundling cables?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties and maintain separation from AC power lines. Bundling high-frequency signals with power cables induces noise into the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760902829,"sku":"330103-00-06-05-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-06-05-02-cn-controller-module-rnhhs1o0h3i.jpg?v=1766977023"},{"product_id":"330103-00-06-15-02-00-bently-nevada-3300-xl-proximity-probe","title":"330103-00-06-15-02-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330103-00-06-15-02-00 is an extension cable used in the 3300 XL 8 mm proximity transducer system to connect the proximity probe to a compatible Proximitor sensor. In eddy-current measurement systems, the cable is part of the calibrated signal path, so correct selection helps maintain measurement stability for shaft vibration and shaft position monitoring.\u003c\/p\u003e\n\u003cp\u003eThis cable is intended for industrial installations where consistent impedance control and secure connector engagement are required to minimize signal loss and intermittent faults. When installed and routed correctly, it supports reliable machinery protection and condition monitoring performance across rotating equipment fleets.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e330103-00-06-15-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity system extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eProbe-to-Proximitor interconnection (eddy-current signal transmission)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eCoaxial, impedance-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Style\u003c\/td\u003e\n\u003ctd\u003eClickLoc quick-connect (option dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Code\u003c\/td\u003e\n\u003ctd\u003e15 (configured length per ordering code)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eAs specified by configuration; verify against site BOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAdditional engineering notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe 3300 XL proximity system calibration depends on the total electrical length of the probe + extension cable + Proximitor. Confirm system matching before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid tight bends and unsupported cable runs near the probe head to reduce mechanical stress and signal intermittency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eTypical uses include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines where proximity probes are used for radial vibration or thrust position measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors in oil and gas service where stable displacement signals support protection logic and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge pumps and motor-driven trains where trending vibration helps reduce seal and bearing failures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaged equipment skids where field cable management and connector security are critical for uptime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstallation considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute away from high-current conductors and VFD outputs where possible to minimize electrical noise coupling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify connector lock engagement and continuity during commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform loop checks and channel verification in the monitor system after cable replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518760968365,"sku":"330103-00-06-15-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-06-15-02-cn-3300-xl-standard-extension-cable-p0xqoalzc0v.jpg?v=1766977027"},{"product_id":"330103-00-12-10-01-00-bently-nevada-extension-cable-3300-xl-series-8mm","title":"330103-00-12-10-01-00 Bently Nevada Extension Cable 3300 XL Series 8mm","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-12-10-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for high-frequency signal transmission between 8 mm proximity probes and Proximitor sensors within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard coaxial extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Cable Length Option (12.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total System Length Option (1.0 meter added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval Option (Multiple international approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting\/Connector Option (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-12-10-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to the target displacement of the monitored machine shaft. Operators must perform gap voltage validation, targeting a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Proper rotor dynamics analysis, including orbital vibration and shaft centerline, relies on the phase-coherent signal transmission through the extension cable to the Proximitor sensor. Effective cross-talk suppression is achieved by observing strict conduit routing standards to prevent interference on the high-frequency carrier signal generated by the system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-12-10-01-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install within dedicated electrical conduit to shield the coaxial path from electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25 mm. Sharp radii deform the internal dielectric and alter impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Tighten coaxial connectors securely. Ensure the connector protector is correctly seated to prevent oil or moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector. Avoid multiple ground points to prevent ground loops that introduce measurement noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be trimmed to match specific installation needs?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for defined lengths. Modifying the cable length alters impedance and phase, leading to invalid vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a damaged connector?\u003c\/p\u003e\n\u003cp\u003eDamage to the connector degrades the signal-to-noise ratio and can cause drift in the gap voltage measurement. Replace the assembly if the connector is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe cable is a passive component. While it can be disconnected from the Proximitor, ensure the channel is in a maintenance mode to avoid triggering false alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is 75 ohm impedance specified?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL architecture is impedance-matched to 75 ohm to ensure maximum fidelity and minimal signal reflection of the high-frequency carrier wave.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable suitable for use in vacuum environments?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are rated for vacuum conditions provided the connections are fully seated and sealed against environmental ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I test for cable continuity?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance multimeter to verify the center conductor and outer shield continuity; ensure no shorts exist between the conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be used with older 3300 series Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is specifically engineered for the 3300 XL system. Use with older series components leads to non-linear signal responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent signal interference when bundling cables?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties and maintain separation from AC power lines. Bundling high-frequency signals with power cables induces noise into the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761066669,"sku":"330103-00-12-10-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-12-10-01-00-3300-xl-8mm-sensor-wdippdutf3o.jpg?v=1766977030"},{"product_id":"330103-00-12-10-02-00-bently-nevada-extension-cable-3300-xl-series","title":"330103-00-12-10-02-00 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-12-10-02-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for high-frequency signal transmission between 8 mm proximity probes and Proximitor sensors within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard coaxial extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Cable Length Option (12.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total System Length Option (1.0 meter added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple international approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting\/Connector Option (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-12-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to the target displacement of the monitored machine shaft. Operators must perform gap voltage validation, targeting a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Proper rotor dynamics analysis, including orbital vibration and shaft centerline, relies on the phase-coherent signal transmission through the extension cable to the Proximitor sensor. Effective cross-talk suppression is achieved by observing strict conduit routing standards to prevent interference on the high-frequency carrier signal generated by the system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-12-10-02-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install within dedicated electrical conduit to shield the coaxial path from electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25 mm. Sharp radii deform the internal dielectric and alter impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Tighten coaxial connectors securely. Ensure the connector protector is correctly seated to prevent oil or moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector. Avoid multiple ground points to prevent ground loops that introduce measurement noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be trimmed to match specific installation needs?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for defined lengths. Modifying the cable length alters impedance and phase, leading to invalid vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a damaged connector?\u003c\/p\u003e\n\u003cp\u003eDamage to the connector degrades the signal-to-noise ratio and can cause drift in the gap voltage measurement. Replace the assembly if the connector is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe cable is a passive component. While it can be disconnected from the Proximitor, ensure the channel is in a maintenance mode to avoid triggering false alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is 75 ohm impedance specified?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL architecture is impedance-matched to 75 ohm to ensure maximum fidelity and minimal signal reflection of the high-frequency carrier wave.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable suitable for use in vacuum environments?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are rated for vacuum conditions provided the connections are fully seated and sealed against environmental ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I test for cable continuity?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance multimeter to verify the center conductor and outer shield continuity; ensure no shorts exist between the conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be used with older 3300 series Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is specifically engineered for the 3300 XL system. Use with older series components leads to non-linear signal responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent signal interference when bundling cables?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties and maintain separation from AC power lines. Bundling high-frequency signals with power cables induces noise into the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761099437,"sku":"330103-00-12-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-12-10-02-00-proximity-probe-5xoj1023gvr.jpg?v=1766977032"},{"product_id":"bently-nevada-330103-00-12-10-02-cn-3300-xl-series-extension-cable","title":"Bently Nevada 330103-00-12-10-02-CN 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-12-10-02-CN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for high-frequency signal transmission between 8 mm proximity probes and Proximitor sensors within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard coaxial extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Cable Length Option (12.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total System Length Option (1.0 meter added to probe length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple international approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Country-specific identification (China).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-12-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system relies on precise eddy-current probe scaling to ensure linear output relative to the target displacement of the machine shaft. Operators must perform gap voltage validation, targeting a -10 VDC setpoint to maintain linearity within the transducer's 2 mm range. Rotor dynamics analysis, such as shaft centerline and orbital vibration monitoring, depends on the phase-coherent signal transmission through the extension cable and Proximitor sensor. Effective cross-talk suppression is achieved by observing strict conduit routing standards to prevent interference on the high-frequency carrier signal generated by the monitoring system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-12-10-02-CN Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install within dedicated electrical conduit to shield the coaxial path from electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25 mm. Sharp radii deform the internal dielectric and alter impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Tighten coaxial connectors securely. Ensure the connector protector is correctly seated to prevent oil or moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector. Avoid multiple ground points to prevent ground loops that introduce measurement noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be trimmed to match specific installation needs?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for defined lengths. Modifying the cable length alters impedance and phase, leading to invalid vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a damaged connector?\u003c\/p\u003e\n\u003cp\u003eDamage to the connector degrades the signal-to-noise ratio and can cause drift in the gap voltage measurement. Replace the assembly if the connector is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe cable is a passive component. While it can be disconnected from the Proximitor, ensure the channel is in a maintenance mode to avoid triggering false alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is 75 ohm impedance specified?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL architecture is impedance-matched to 75 ohm to ensure maximum fidelity and minimal signal reflection of the high-frequency carrier wave.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable suitable for use in vacuum environments?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are rated for vacuum conditions provided the connections are fully seated and sealed against environmental ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I test for cable continuity?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance multimeter to verify the center conductor and outer shield continuity; ensure no shorts exist between the conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be used with older 3300 series Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is specifically engineered for the 3300 XL system. Use with older series components leads to non-linear signal responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent signal interference when bundling cables?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties and maintain separation from AC power lines. Bundling high-frequency signals with power cables induces noise into the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761525421,"sku":"330103-00-12-10-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-12-10-02-cn-3300-xl-8-mm-proximity-transducer-124m1bz1wov.jpg?v=1766977034"},{"product_id":"330103-00-14-05-02-00-bently-nevada-3300-xl-series-extension-cable","title":"330103-00-14-05-02-00 Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eConfigured for high-frequency signal transmission in rotating machinery monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-14-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical\/electrical execution between 8 mm proximity probes and Proximitor sensors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL standard coaxial extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Connector\/Cable Option (Standard connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e14\u003c\/strong\u003e: Cable Length Option (14.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total System Length Option (5.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Agency Approval Option (Multiple international approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Internal Mounting\/Connector Option (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-14-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.90 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 cm x 25 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes precise eddy-current probe scaling to ensure linear output relative to the target displacement of the monitored machine shaft. Field technicians must perform gap voltage validation, targeting a -10 VDC setpoint to maintain optimal linearity within the transducer's 2 mm range. Accurate rotor dynamics analysis, including shaft centerline and orbital vibration monitoring, depends on phase-coherent signal transmission through the extension cable to the Proximitor sensor. Effective cross-talk suppression is achieved by observing strict conduit routing standards to prevent electrical interference on the high-frequency carrier signal.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-14-05-02-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Cable connector assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Routing: Install within dedicated electrical conduit to shield the coaxial path from electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Maintain a minimum bend radius of 25 mm. Sharp radii deform the internal dielectric, which degrades impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Tighten coaxial connectors securely using the factory-specified torque. Ensure the connector protector is seated correctly to prevent oil or moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous through the connector. Avoid multiple ground points to prevent ground loops that induce measurement noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be trimmed to match specific installation needs?\u003c\/p\u003e\n\u003cp\u003eNo. The system is factory-calibrated for defined lengths. Modifying the cable length alters impedance and phase, leading to invalid vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of a damaged connector?\u003c\/p\u003e\n\u003cp\u003eDamage to the connector degrades the signal-to-noise ratio and causes drift in the gap voltage measurement. Replace the assembly if the connector is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe cable is a passive component. While it can be disconnected from the Proximitor, ensure the channel is in a maintenance mode to avoid triggering false alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is 75 ohm impedance specified?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL architecture is impedance-matched to 75 ohm to ensure maximum fidelity and minimal signal reflection of the high-frequency carrier wave.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable suitable for use in vacuum environments?\u003c\/p\u003e\n\u003cp\u003eYes, the materials are rated for vacuum conditions provided the connections are fully seated and sealed against environmental ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I test for cable continuity?\u003c\/p\u003e\n\u003cp\u003eUse a high-impedance multimeter to verify the center conductor and outer shield continuity; ensure no shorts exist between the conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be used with older 3300 series Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is specifically engineered for the 3300 XL system. Use with older series components leads to non-linear signal responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I prevent signal interference when bundling cables?\u003c\/p\u003e\n\u003cp\u003eUse non-metallic cable ties and maintain separation from AC power lines. Bundling high-frequency signals with power cables induces noise into the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761558189,"sku":"330103-00-14-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-14-05-02-00-3300-xl-8-mm-proximity-cable-pnhjvvy2py4.jpg?v=1766977035"},{"product_id":"330103-00-16-10-12-05-bently-nevada-extension-cable-3300-xl-series","title":"330103-00-16-10-12-05 Bently Nevada Extension Cable 3300 XL Series","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for signal transmission between proximity probes and monitoring instrumentation in 3300 XL Series systems, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"122\"\u003eBently Nevada 330103-00-16-10-12-05\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"159\"\u003e330103\u003c\/b\u003e Extension Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Configuration Matrix\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe assembly follows the standard 3300 XL nomenclature:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e330103: Base Model (Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e00: Unarmored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e16: 1.6 meters length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e10: Connector protector kit included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e12: Miniature coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e05: Agency approval option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"9\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,1,0\"\u003e330103-00-16-10-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,1,0\"\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,1,0\"\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,1,0\"\u003e25 cm x 25 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,1,0\"\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,1,0\"\u003ePassive (Impedance matching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,0,0\"\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,1,0\"\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,0,0\"\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,1,0\"\u003e0 Hz to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eEddy-Current Transducer Performance\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe cable assembly maintains the 50 Ohm system impedance required for the 3300 XL transducer system to ensure accurate eddy-current probe scaling. This component facilitates precise gap voltage validation, targeting -10 VDC at the monitor input. Shielded construction provides cross-talk suppression, maintaining signal integrity required for rotor dynamics analysis. Insertion loss is controlled to prevent deviations in displacement measurement sensitivity during high-speed rotating machinery monitoring.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e1 x 330103-00-16-10-12-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e1 x Connector Protector Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e1 x Safety and Installation Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003eRouting\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,1,0,0\"\u003eInstall within rigid or flexible conduit to protect the coaxial jacket from mechanical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,1,1,0\"\u003eAdhere to a minimum bend radius of 25 mm to prevent dielectric deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eTermination\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,1,0,0\"\u003eClean all connector interfaces using a non-residue electronic cleaner prior to mating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,1,1,0\"\u003eTighten connectors by hand to ensure consistent electrical contact and maintain shielding continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003eGrounding\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,1,0,0\"\u003eEnsure the transducer mounting assembly provides a low-impedance ground path to the machine casing to prevent ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eCan this cable be used for legacy probe systems?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eThis cable is specifically designed for 3300 XL transducer systems to maintain a 50 Ohm characteristic impedance. Use with other systems may cause calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eIs it possible to splice this cable to increase length?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eNo. Modifying the cable length alters the impedance and capacitance, which will negatively impact the frequency response and accuracy of the transducer output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eWhat is the purpose of the connector protector?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eThe connector protector provides environmental sealing at the interface between the probe cable and extension cable, preventing fluid ingress and oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eHow should the cable be shielded?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eThe outer jacket and internal shield are factory-integrated. Do not strip or alter the shielding; ensure the entire path remains unbroken back to the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eDoes the cable require thermal insulation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eThe cable is rated for operation up to 177 deg C. It does not require additional insulation unless environmental temperatures exceed this specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003eWhat does the -10 VDC target refer to?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003eThis is the standard baseline gap voltage for Bently Nevada proximity systems when the probe is at the designed electrical zero position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eCan this cable be hot-swapped?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eThe extension cable is a passive component. While it can be replaced, signal disruption will occur at the monitoring system during the disconnection process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eHow do I confirm the cable is functioning correctly?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eVerify the signal path using a multimeter to ensure continuity and check for correct gap voltage readings during system commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761590957,"sku":"330103-00-16-10-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-16-10-12-05-proximity-cable-ft1r4l1yavw.jpg?v=1766977036"},{"product_id":"bently-nevada-330103-00-21-10-11-cn-3300-xl-series-extension-cable","title":"Bently Nevada 330103-00-21-10-11-CN 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-21-10-11-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute signal transmission between proximity probes and monitoring systems across 3300 XL Series platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330103: Base Model (Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unarmored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e21: 2.1 meters total length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Connector protector kit included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11: Miniature coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: Country-specific agency approval variant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-21-10-11-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 25 cm x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance matching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 330103-00-21-10-11-CN is engineered to maintain constant characteristic impedance, which is required for eddy-current probe scaling within the 3300 XL transducer system. The assembly ensures gap voltage validation, with target operating points calibrated to -10 VDC at the monitor input. Cross-talk suppression is maintained through high-performance shielding, allowing for accurate rotor dynamics monitoring without signal degradation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-00-21-10-11-CN Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector Protector Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Safety Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute cable through dedicated conduit to avoid mechanical strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum bend radius of 25 mm during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eTermination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean all coaxial connector interfaces with non-residue electronic cleaner prior to engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify mechanical security of the ClickLoc connector to ensure electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe cable shield must maintain a continuous low-impedance path to the machine casing ground to avoid interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with non-XL 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eThis extension cable is tuned for the 3300 XL system impedance. Usage with other series may lead to calibration inaccuracies and erroneous gap readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable length be modified in the field?\u003c\/p\u003e\n\u003cp\u003eNo. The coaxial assembly is factory-terminated to specific lengths to maintain 50 Ohm impedance. Any modification will compromise signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is there a connector protector kit?\u003c\/p\u003e\n\u003cp\u003eThe protector provides an environmental seal at the cable interface, preventing the ingress of oil and moisture which causes high-resistance contact points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the -10 VDC target voltage signify?\u003c\/p\u003e\n\u003cp\u003eThis is the required operating gap voltage for Bently Nevada proximity systems, indicating the probe is at its calibrated electrical zero position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the cable be shielded?\u003c\/p\u003e\n\u003cp\u003eThe cable is provided with an integral shield. Ensure this shield is not compromised during installation to prevent ground loop noise from entering the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable field-repairable?\u003c\/p\u003e\n\u003cp\u003eNo. Factory-molded coaxial connectors are used to ensure impedance consistency. Damage to connectors necessitates replacement of the entire cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of cable length on frequency?\u003c\/p\u003e\n\u003cp\u003eSignal attenuation increases with length, but for this 2.1 m assembly, frequency response remains flat up to 10 kHz within standard system loop constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable operate in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eThe cable is rated for 177 deg C. Ensure the installation area does not exceed this rating, and protect the cable from direct contact with extreme heat sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761623725,"sku":"330103-00-21-10-11-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-21-10-11-cn-extension-cable-3lybqq4sgdb.jpg?v=1766977037"},{"product_id":"330103-05-10-10-12-05-bently-nevada-3300-xl-series-proximity-probe","title":"330103-05-10-10-12-05 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for non-contact displacement measurement in 3300 XL Series machinery protection platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-05-10-10-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330103: Base Model (Proximity Probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: 8 mm probe tip diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 1.0 meter cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Connector type (standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Total length and agency approval configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Mounting thread specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-05-10-10-12-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 20 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance regulated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThis probe utilizes eddy-current probe scaling to convert target distance into an output voltage. System integration requires precise gap voltage validation, targeting -10 VDC at the monitor input when the probe is at the nominal gap. The transducer system relies on consistent rotor dynamics data, where cross-talk suppression is achieved through controlled coaxial cable impedance and proper shielding. The 8 mm tip provides a linear measurement range suitable for monitoring shaft vibration and axial position.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-05-10-10-12-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Mounting Nut and Lockwasher Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation and Safety Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe into the mounting bracket, ensuring at least 5 full NPT or metric thread engagements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse locking nuts to secure the probe position after achieving the target gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure coaxial connectors are free of contaminants before mating to prevent signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute probe cabling through dedicated rigid conduit to protect against mechanical fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe probe housing must maintain electrical continuity with the machine case to ensure proper system shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used as a standalone sensor?\u003c\/p\u003e\n\u003cp\u003eNo. This probe is a component of a 3300 XL transducer system and must be connected to a matching proximity extension cable and Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I calibrate the probe gap?\u003c\/p\u003e\n\u003cp\u003eAdjust the probe position while monitoring the DC gap voltage at the monitor\/BNC output until the required -10 VDC is achieved.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable length field-adjustable?\u003c\/p\u003e\n\u003cp\u003eNo. The cable length is fixed and calibrated to the system. Changing the length will alter the resonant frequency and system impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe tip be exposed to high pressure?\u003c\/p\u003e\n\u003cp\u003eThe probe tip is rated for high-pressure oil\/fluid exposure, but ensure the housing seal is installed correctly to prevent leakage at the mounting point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the frequency range of this probe?\u003c\/p\u003e\n\u003cp\u003eThe probe system is designed to provide a linear response from 0 Hz (static) to 10 kHz (dynamic vibration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eNo. Replacing the probe requires system isolation, as disconnecting the transducer will trigger a sensor fault signal in the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the cable shield impact performance?\u003c\/p\u003e\n\u003cp\u003eThe shield prevents external electrical interference. Ensure the shield integrity is maintained from the probe head to the monitor terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of probe misalignment?\u003c\/p\u003e\n\u003cp\u003eMisalignment relative to the target surface center can reduce measurement linearity and impact the accuracy of vibration amplitude readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761689261,"sku":"330103-05-10-10-12-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-05-10-10-12-05-3300-xl-8-mm-proximity-probes-d0mk04r5leh.jpg?v=1766977040"},{"product_id":"330103-08-15-10-02-00-bently-nevada-3300-xl-series-proximity-probe","title":"330103-08-15-10-02-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for non-contact displacement measurement in 3300 XL Series machinery monitoring environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-08-15-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330103: Base Model (Proximity Probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: 8 mm probe tip diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e15: 1.5 meter cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Connector type (standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Total length and agency approval configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No agency approval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-08-15-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 25 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance regulated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer utilizes eddy-current probe scaling to convert proximity to target into proportional voltage output. System stability requires gap voltage validation, with typical targets at -10 VDC at the monitor input when at the designated electrical zero. Cross-talk suppression is maintained through integrated coaxial shielding to ensure signal integrity for accurate rotor dynamics analysis, preventing measurement errors in high-speed rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-08-15-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Mounting Nut and Lockwasher Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure a minimum of 5 full thread engagements when mounting into the probe bracket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse locking nuts to secure the probe position relative to the target surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean coaxial connector interfaces using non-residue cleaner before mating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the ClickLoc connector is fully engaged to maintain 50 Ohm impedance continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a low-impedance ground path between the probe housing and the machine case to avoid ground loop noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with non-3300 XL monitor systems?\u003c\/p\u003e\n\u003cp\u003eThis probe is calibrated for the 3300 XL transducer system. Usage with legacy monitoring hardware requires verification of compatibility to prevent scaling errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe cable be field-spliced?\u003c\/p\u003e\n\u003cp\u003eNo. The cable is factory-calibrated to a specific length to maintain 50 Ohm impedance. Splicing will alter the electrical resonance and degrade measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the -10 VDC gap voltage target represent?\u003c\/p\u003e\n\u003cp\u003eThis is the standard operating voltage for the probe at its calibrated zero-gap position, which allows the system to monitor both positive and negative vibration excursions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe tip sensitive to high temperatures?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated for operation up to 177 deg C. Ensure the installation location does not exceed this rating, as excessive heat will result in non-linear signal output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the cable be protected during installation?\u003c\/p\u003e\n\u003cp\u003eRoute cables through rigid or flexible metal conduit to prevent mechanical damage, abrasion, or exposure to corrosive lubricants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be hot-swapped while the machine is running?\u003c\/p\u003e\n\u003cp\u003eNo. Replacing the probe will result in a sensor fault or open-circuit condition, which will likely trigger a machinery protection alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of probe misalignment?\u003c\/p\u003e\n\u003cp\u003eMisalignment relative to the target surface center can introduce non-linearities and potential signal errors, affecting the quality of the rotor displacement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the shield internally grounded?\u003c\/p\u003e\n\u003cp\u003eThe shield is part of the electrical loop. Do not ground the cable shield at any point other than the designated monitor or transducer ground connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761722029,"sku":"330103-08-15-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-08-15-10-02-00-3300-xl-8-mm-proximity-probe-4gzcvn2dbct.jpg?v=1766977041"},{"product_id":"330103-12-25-10-02-00-bently-nevada-3300-xl-series-extension-cable","title":"330103-12-25-10-02-00 Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-12-25-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute signal transmission between proximity probes and monitoring instrumentation across 3300 XL Series platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330103: Base Model (Extension Cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Cable configuration\/length designation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25: Specified length parameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Connector protector kit included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Miniature coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-12-25-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 25 cm x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance matching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe cable assembly is engineered to maintain constant characteristic impedance, which is required for eddy-current probe scaling within the 3300 XL transducer system. This component facilitates precise gap voltage validation, with target operating points centered at -10 VDC at the monitor input. Shielded coaxial construction provides cross-talk suppression, maintaining the signal-to-noise ratio required for accurate rotor dynamics monitoring and shaft displacement analysis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-12-25-10-02-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector Protector Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Safety Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall cabling within dedicated electrical conduit to prevent mechanical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum bend radius of 25 mm to preserve dielectric integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eTermination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean all coaxial connector interfaces with non-residue electronic cleaner prior to engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure secure seating of the ClickLoc connector to maintain consistent 50 Ohm electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe cable shield must maintain a continuous low-impedance path to the machine casing ground to prevent signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be used with non-XL 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eThis cable is specifically tuned for the 3300 XL transducer system. Using it with legacy probes may result in incorrect system impedance and erroneous gap voltage readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable length field-adjustable?\u003c\/p\u003e\n\u003cp\u003eNo. The coaxial assembly is factory-trimmed to maintain 50 Ohm impedance. Any field modifications will cause signal reflections and loss of calibration accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is there a connector protector included?\u003c\/p\u003e\n\u003cp\u003eThe connector protector provides environmental sealing at the interface between the probe cable and the extension cable, preventing oxidation and fluid ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable require specific grounding?\u003c\/p\u003e\n\u003cp\u003eThe cable shielding is integrated into the probe system ground path. Ensure the mounting bracket provides a clean metal-to-metal contact to the machine case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the cable jacket is compromised?\u003c\/p\u003e\n\u003cp\u003eCompromised insulation allows moisture or oil ingress, leading to signal noise, drift in gap voltage, and potentially false vibration alarms in the TSI system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this component field-repairable?\u003c\/p\u003e\n\u003cp\u003eNo. The coaxial cable assembly is factory-molded for impedance consistency. Damage to the cable or connectors necessitates a full replacement of the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does cable length affect frequency response?\u003c\/p\u003e\n\u003cp\u003eSignal attenuation increases with length, but for standard 3300 XL systems, the frequency response remains flat up to 10 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable operate in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eYes, the material composition supports operation up to 177 deg C, provided the cable is not subjected to mechanical vibration that exceeds its fatigue limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761787565,"sku":"330103-12-25-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-12-25-10-02-00-proximity-transducer-aigfqlu55sx.jpg?v=1766977042"},{"product_id":"bently-nevada-330104-00-06-10-02-cn-3300-xl-series-proximity-probe","title":"Bently Nevada 330104-00-06-10-02-CN 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-06-10-02-CN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contact displacement signal acquisition within 3300 XL Series machinery protection platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: Base Model (Proximity Probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unarmored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e06: 0.6 meter length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Connector type (standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Total length configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: Country-specific agency approval\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-06-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 20 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance regulated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Probe Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe transducer utilizes eddy-current probe scaling to convert target proximity into a linear voltage signal. System accuracy depends on gap voltage validation, requiring a target of -10 VDC at the monitor input when at the designated electrical zero. Integrated coaxial shielding ensures cross-talk suppression, maintaining signal fidelity for high-speed vibration analysis and axial position monitoring.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-06-10-02-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Mounting Nut and Lockwasher Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Safety and Installation Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure a minimum of 5 full thread engagements when mounting the probe into the bracket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse locking nuts to secure the probe position after achieving the target gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean all coaxial connector interfaces with non-residue electronic cleaner before mating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify ClickLoc mechanism engagement to ensure 50 Ohm impedance continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe probe housing must maintain electrical continuity with the machine casing to complete the system ground path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used as a standalone sensor?\u003c\/p\u003e\n\u003cp\u003eNo. This probe is part of a tuned 3300 XL transducer system and must be coupled with the appropriate extension cable and Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe gap verified?\u003c\/p\u003e\n\u003cp\u003eMonitor the DC gap voltage at the transducer monitor or BNC output, adjusting the probe depth until the -10 VDC target is achieved.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable length field-adjustable?\u003c\/p\u003e\n\u003cp\u003eNo. Cable lengths are factory-trimmed to maintain the 50 Ohm impedance characteristic. Modification will cause signal reflections and calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental conditions can the probe withstand?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated for operation up to 177 deg C and is resistant to typical industrial fluids, provided the mounting seals are properly installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be hot-swapped?\u003c\/p\u003e\n\u003cp\u003eNo. Disconnecting the probe while the system is operational will trigger a transducer fault in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes probe misalignment affect data?\u003c\/p\u003e\n\u003cp\u003eYes. Misalignment relative to the target surface center can introduce non-linearities and degrade vibration amplitude measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the frequency response?\u003c\/p\u003e\n\u003cp\u003eThe system provides a linear frequency response from 0 Hz (static) to 10 kHz (dynamic).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should cables be routed?\u003c\/p\u003e\n\u003cp\u003eCables must be routed through rigid or flexible metal conduit to prevent mechanical damage and exposure to electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761820333,"sku":"330104-00-06-10-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-06-10-02-cn-proximity-probes-r0uumpnjg4f.jpg?v=1766977042"},{"product_id":"330104-00-08-05-02-05-bently-nevada-proximity-probe-3300-xl","title":"330104-00-08-05-02-05 Bently Nevada Proximity Probe 3300 XL","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-08-05-02-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration monitoring within rotating machinery platforms.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix and Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-08-05-02-05 part number specifies:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e00: Metric M10 x 1 thread without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: 80 mm case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: 0.5 meter (1.6 feet) total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: CSA, ATEX, and IECEx hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-08-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 1.8 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc Miniature Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Transducer Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes eddy-current probe scaling to ensure linear displacement output. During system commissioning, gap voltage validation is performed to align the transducer tip with the -10 VDC target, providing the reference required for accurate radial vibration and axial position measurement. The probe design incorporates cross-talk suppression to maintain signal integrity in high-density installations, preventing mutual interference between multiple proximity channels on the same rotating assembly.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-08-05-02-05 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation hardware set (mounting nuts).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical manual set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe into the mounting bracket until the required gap is achieved.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the probe depth to reach a nominal -10 VDC reading at the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the transducer using the provided locknuts to prevent mechanical shift due to machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the ClickLoc connector is fully seated to prevent signal noise or intermittency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield continuity to the monitoring system ground to minimize common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the frequency response of this probe?\u003c\/p\u003e\n\u003cp\u003eThe probe supports a frequency range from 0 to 10 kHz (-3 dB), suitable for both static displacement and dynamic vibration analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eYes, the 05 suffix indicates compliance with CSA, ATEX, and IECEx standards for operation in classified hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe field-repairable?\u003c\/p\u003e\n\u003cp\u003eNo, the transducer is a factory-calibrated assembly. Any attempt to repair the cable or probe tip will compromise measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the ClickLoc connector used?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector provides a secure, vibration-resistant connection that prevents accidental disconnection during mechanical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I replace the 0.5 meter cable with a longer one?\u003c\/p\u003e\n\u003cp\u003eNo, the system is calibrated as a matched set; changing the cable length alters the electrical resonance and invalidates the output linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the gap voltage range?\u003c\/p\u003e\n\u003cp\u003eThe linear operating range is typically set around a -10 VDC reference; deviations indicate the probe is outside the linear transduction range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe compatible with 3300 XL extension cables?\u003c\/p\u003e\n\u003cp\u003eYes, this probe is compatible with standard 3300 XL extension cables and Proximitor sensors, provided the total system length is consistent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify the probe thread type?\u003c\/p\u003e\n\u003cp\u003eThe 00 suffix denotes an M10 x 1 metric thread configuration for installation into standardized machinery mounting brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761853101,"sku":"330104-00-08-05-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-08-05-02-05-3300xl-8-mm-proximity-probes-kmvwemhgl21.jpg?v=1766977044"},{"product_id":"330104-00-20-10-02-00-bently-nevada-3300-xl-proximity-probe","title":"330104-00-20-10-02-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for high-speed machinery monitoring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-20-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction for radial vibration, thrust position, and speed reference measurement within TSI platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-20-10-02-00 model is defined by the following specifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e00: M10 x 1 threaded probe (Note: base model specification implies standard thread configuration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e20: 2.0 inch case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 1.0 meter (3.3 feet) integral system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Standard regulatory approval configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-20-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e113 x 1.8 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReverse Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system utilizes eddy-current probe scaling to convert conductive target proximity into proportional voltage output. System accuracy is contingent upon rigorous gap voltage validation to ensure operation within the linear -10 VDC range. To ensure rotor dynamics data integrity, cross-talk suppression must be implemented in multi-probe arrays. Proper signal isolation prevents spectral interference, maintaining the validity of shaft centerline, eccentricity, and phase reference measurements in high-speed rotating equipment.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-20-10-02-00 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation hardware kit (locknuts).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the probe is mounted in a reverse-mount configuration to achieve stable target coverage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the probe gap until the monitoring interface displays the nominal -10 VDC gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCabling and Terminations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the ClickLoc miniature coaxial interface for a vibration-resistant connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute cables through dedicated conduit to shield from electromagnetic interference and mechanical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround shields only at the monitor rack to avoid ground loop currents in the sensing circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the linear range of this 8 mm probe?\u003c\/p\u003e\n\u003cp\u003eThe probe offers a linear measurement range of 2.0 mm (80 mils), sufficient for detecting radial vibration and thrust displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used for Keyphasor signals?\u003c\/p\u003e\n\u003cp\u003eYes, the high frequency response and sensitivity make this probe suitable for speed and phase reference (Keyphasor) applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the thread size standard?\u003c\/p\u003e\n\u003cp\u003eThis unit features a 3\/8-24 UNF thread size, typical for reverse-mount 3300 XL probe applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector is designed to provide a secure, locking mechanical interface that prevents signal loss due to vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe compatible with 3500 series racks?\u003c\/p\u003e\n\u003cp\u003eYes, the 330104 probe integrates with 3500 and 2300 machinery protection systems when paired with an appropriate Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the gap voltage is outside specification?\u003c\/p\u003e\n\u003cp\u003eOperating outside the linear -10 VDC target range may result in signal clipping, leading to distorted vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require external power?\u003c\/p\u003e\n\u003cp\u003eNo, the transducer is passive and powered through the Proximitor unit via the coaxial signal cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this probe in fluid-film bearings?\u003c\/p\u003e\n\u003cp\u003eYes, the probe is standard for monitoring radial vibration in fluid-film bearing configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761885869,"sku":"330104-00-20-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-20-10-02-00-proximity-probes-22xgfu3ghun.jpg?v=1766977046"},{"product_id":"330104-00-25-10-02-00-bently-nevada-3300-xl-proximity-probe","title":"330104-00-25-10-02-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for high-precision displacement sensing in industrial monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-25-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction of rotor position and vibration within mechanical clearances.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-25-10-02-00 part number signifies the following mechanical and electrical build:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e00: Metric 3\/8-24 UNF thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25: 2.5 inch (63.5 mm) overall case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 1.0 meter (3.3 feet) integral system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Standard regulatory approval configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-25-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 x 2.0 x 2.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes eddy-current probe scaling to convert target movement into precise voltage variations. Successful measurement depends on gap voltage validation; installers must verify that the probe tip is positioned within the linear -10 VDC target range at the Proximitor output. The design incorporates cross-talk suppression, enabling high-density sensor mounting while isolating vibration data from potential interference sources, which preserves the accuracy of shaft centerline and rotor dynamics analysis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-25-10-02-00 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation hardware kit (locknuts).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Regulatory documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the probe using the fully threaded case design into a rigid mounting bracket to prevent resonant vibration coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the probe gap until the output voltage reaches the nominal -10 VDC setpoint at the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUtilize the ClickLoc connector for a high-integrity, vibration-proof link to the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the coaxial cable shield is grounded exclusively at the monitoring system's terminal block to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the PPS probe tip?\u003c\/p\u003e\n\u003cp\u003eThe polyphenylene sulfide (PPS) tip ensures dimensional stability and chemical resistance in harsh industrial environments, preventing signal drift due to material degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the integral 1.0 meter cable?\u003c\/p\u003e\n\u003cp\u003eNo, the cable is a calibrated component of the transducer system; modifying its length alters electrical resonance and voids calibration accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the case fully threaded?\u003c\/p\u003e\n\u003cp\u003eThe 2.5-inch fully threaded case provides maximum mounting flexibility in machines with varying clearance requirements and simplifies depth adjustment during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I confirm the probe is operating linearly?\u003c\/p\u003e\n\u003cp\u003ePerform a static gap check using a target material identical to the shaft; the Proximitor output must track within the defined linear -10 VDC operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector waterproof?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector is designed for industrial use but requires proper installation and protection from direct liquid submersion to maintain contact integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require maintenance?\u003c\/p\u003e\n\u003cp\u003eThe probe is a solid-state, factory-sealed device. Maintenance is limited to periodic inspection of the probe tip for wear and verifying terminal connection tightness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used for speed measurement?\u003c\/p\u003e\n\u003cp\u003eYes, the 0 to 10 kHz frequency response is sufficient for detecting keyway pulses or shaft features for speed and phase reference generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does thermal shift affect the signal?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL design includes compensation to minimize temperature-induced signal variation, ensuring stable readings during machine warm-up and steady-state operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761918637,"sku":"330104-00-25-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-25-10-02-00-proximity-probes-ixuyzcxu02p.jpg?v=1766977047"},{"product_id":"330104-00-25-10-02-05-bently-nevada-proximity-probe-3300-xl","title":"330104-00-25-10-02-05 Bently Nevada Proximity Probe 3300 XL","description":"\u003cp\u003eConfigured for high-precision displacement sensing in industrial monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-25-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e) Proximity Probe provides direct physical signal transduction of rotor position and vibration within mechanical clearances.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-25-10-02-05 part number specifies the following build characteristics:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e00: Metric 3\/8-24 UNF thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25: 2.5 inch (63.5 mm) overall case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 1.0 meter (3.3 feet) integral system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: CSA, ATEX, and IECEx agency approval rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-25-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.0 x 2.0 x 2.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system requires precise eddy-current probe scaling to ensure linear displacement output. Accurate rotor dynamics analysis depends on gap voltage validation to target the -10 VDC baseline at the Proximitor output, which establishes the reference for all subsequent displacement measurements. The system provides integrated cross-talk suppression, ensuring signal integrity is maintained even when multiple sensors are mounted in high-density proximity arrays within machine housings.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-25-10-02-05 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation hardware kit (nuts).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the probe into the mounting bracket using the 3\/8-24 UNF threads; ensure the tip is positioned according to the required gap specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse the provided locknuts to prevent mechanical migration due to machine-induced vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the coaxial probe cable to the extension cable or Proximitor using the ClickLoc interface, ensuring the connection is fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield integrity to the monitoring system ground to minimize common-mode noise in the 4-20 mA or raw voltage loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary purpose of the PPS probe tip?\u003c\/p\u003e\n\u003cp\u003eThe polyphenylene sulfide (PPS) tip provides chemical and moisture resistance, ensuring the probe remains stable when exposed to process lubricants and varied atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous environments?\u003c\/p\u003e\n\u003cp\u003eYes, the 05 suffix indicates the probe meets CSA, ATEX, and IECEx requirements for installation in classified hazardous zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330104-00-25-10-02-05 interchangeable with older probes?\u003c\/p\u003e\n\u003cp\u003eIt is designed for the 3300 XL system and is fully compatible with 3300 XL extension cables and Proximitors when maintaining the designated system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of the 2.5 inch case length?\u003c\/p\u003e\n\u003cp\u003eThe 2.5 inch case length provides a fully threaded body, allowing for greater adjustment range in machines with thick casings or specific mounting depth requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe output scaled?\u003c\/p\u003e\n\u003cp\u003eThe system provides a standard scale factor of 7.87 V\/mm (200 mV\/mil) when properly paired with a 3300 XL Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the cable be field-terminated?\u003c\/p\u003e\n\u003cp\u003eNo, the integral cable is factory-calibrated. Field termination or shortening the cable will alter the system electrical resonance and degrade measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating temperature?\u003c\/p\u003e\n\u003cp\u003eThe transducer is rated for continuous operation within a temperature range of -51 deg C to +177 deg C, supported by internal thermal compensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe case grounded?\u003c\/p\u003e\n\u003cp\u003eThe stainless steel case provides an environmental and electrical shield; ensure the mounting bracket is properly grounded to the machine frame to prevent interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761951405,"sku":"330104-00-25-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-25-10-02-05-proximity-probes-ioaf2i2ft1i.jpg?v=1766977048"},{"product_id":"bently-nevada-330104-03-06-05-02-00-3300-xl-8mm-proximity-probes","title":"Bently Nevada 330104-03-06-05-02-00 3300 XL 8mm Proximity Probes","description":"\u003cp\u003eThe 330104-03-06-05-02-00, also cataloged as the 3300 XL 8mm Proximity Probes, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This sensor system utilizes eddy current technology to facilitate non-contact displacement monitoring. By maintaining a constant gap measurement between the probe tip and the target material, the system transmits precise vibration and axial position data to monitoring instrumentation. The unit is engineered for reverse mount applications, requiring installation from the internal side of the machine housing, ensuring integration into critical rotating equipment monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 3\/8-24 UNF threads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 0.6 inch case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 0.5 meter (1.6 feet) total length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Overview\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-03-06-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Processing and Vibration Analysis\u003c\/h3\u003e\n\u003cp\u003eThe 330104-03-06-05-02-00 is calibrated for eddy current probe scaling within the 3300 XL transducer system. The system requires a -24 VDC supply provided by the Proximitor sensor. Proper operation necessitates monitoring the gap voltage, typically set to -10 VDC mid-range to ensure linear response for rotor dynamics analysis. This sensor provides the fundamental input for detecting shaft orbital motion, axial displacement, and radial vibration. The integrity of the signal processing chain relies on the ClickLoc connector, which maintains low contact resistance and minimizes signal attenuation in environments characterized by high-frequency machinery oscillation.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-03-06-05-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation and Setup Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Certification and Conformity Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Site Integration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the probe is threaded into the machine housing using the provided 3\/8-24 UNF threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a torque of 5.6 Nm to secure the probe, ensuring the housing remains free from structural stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute coaxial cables through grounded metallic conduits to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain the integrity of the ClickLoc connector by ensuring no tension is applied to the cable junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eObserve a minimum radial clearance of 3 times the probe tip diameter from surrounding metallic obstructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the gap voltage using a digital voltmeter during the final alignment process to ensure the sensor is centered within its linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330104 probe require calibration with the extension cable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 330104-03-06-05-02-00 is calibrated as a system including the probe, extension cable, and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be used in high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip and stainless steel case are designed to withstand high-pressure fluid environments common in industrial compressors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector provides a vibration-resistant, repeatable electrical connection that maintains signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically insulated from the machine housing via the mounting bracket to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can I replace the probe without replacing the Proximitor?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new probe has the same physical and electrical specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length supported for this model?\u003c\/p\u003e\n\u003cp\u003eA: This model includes a 0.5 meter integral cable; system length is determined by the total length including the specific extension cable chosen.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe detect shaft vibration?\u003c\/p\u003e\n\u003cp\u003eA: It measures the change in eddy current density as the gap between the probe tip and the shaft surface fluctuates.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761984173,"sku":"330104-03-06-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-03-06-05-02-00-proximity-probes-fcvxhtiixh3.jpg?v=1766977049"},{"product_id":"bently-nevada-330104-15-23-10-02-00-3300-xl-8mm-proximity-probes","title":"Bently Nevada 330104-15-23-10-02-00 3300 XL 8mm Proximity Probes","description":"\u003cp\u003eThe 330104-15-23-10-02-00, also cataloged as the 3300 XL 8mm Proximity Probes, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This sensor system utilizes eddy current technology to facilitate non-contact displacement monitoring. By maintaining a constant gap measurement between the probe tip and the target material, the system transmits precise vibration and axial position data to monitoring instrumentation, including the Bently Nevada 3500 series. The unit is engineered for reverse mount applications, requiring installation from the internal side of the machine housing, and is optimized for deployment on steam and gas turbines, centrifugal compressors, and large-scale industrial motors.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15\u003c\/strong\u003e: 3\/8-24 UNF threads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e23\u003c\/strong\u003e: 1.5 inch case length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: 1.0 meter (3.3 feet) total length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval (Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-15-23-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Processing and Vibration Analysis\u003c\/h3\u003e\n\u003cp\u003eThe 330104-15-23-10-02-00 is calibrated for eddy current probe scaling within the 3300 XL transducer system. The system requires a -24 VDC supply provided by the Proximitor sensor. Proper operation necessitates monitoring the gap voltage, typically set to -10 VDC mid-range to ensure linear response for rotor dynamics analysis. This sensor provides the fundamental input for detecting shaft orbital motion, axial displacement, and radial vibration. The integrity of the signal processing chain relies on the ClickLoc connector, which maintains low contact resistance and minimizes signal attenuation in environments characterized by high-frequency machinery oscillation.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330104-15-23-10-02-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Installation and Setup Manual\u003c\/li\u003e\n\u003cli\u003e1 x Product Certification and Conformity Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Site Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the probe is threaded into the machine housing using the 3\/8-24 UNF threads.\u003c\/li\u003e\n\u003cli\u003eApply a torque of 5.6 Nm to secure the probe, ensuring the housing remains free from structural stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRoute coaxial cables through grounded metallic conduits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain the integrity of the ClickLoc connector by ensuring no tension is applied to the cable junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Clearance\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eObserve a minimum radial clearance of 3 times the probe tip diameter from surrounding metallic obstructions.\u003c\/li\u003e\n\u003cli\u003eVerify the gap voltage using a digital voltmeter during the final alignment process to ensure the sensor is centered within its linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330104 probe require calibration with the extension cable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 330104-15-23-10-02-00 is calibrated as a system including the probe, extension cable, and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be used in high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip and stainless steel case are designed to withstand high-pressure fluid environments common in industrial compressors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector provides a vibration-resistant, repeatable electrical connection that maintains signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically insulated from the machine housing via the mounting bracket to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can I replace the probe without replacing the Proximitor?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new probe has the same physical and electrical specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length supported for this model?\u003c\/p\u003e\n\u003cp\u003eA: This model includes a 1.0 meter integral cable; system length is determined by the total length including the specific extension cable chosen.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe detect shaft vibration?\u003c\/p\u003e\n\u003cp\u003eA: It measures the change in eddy current density as the gap between the probe tip and the shaft surface fluctuates.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762016941,"sku":"330104-15-23-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-15-23-10-02-00-vibration-probe-sdosmo14slv.jpg?v=1766977050"},{"product_id":"bently-nevada-330105-00-05-10-02-00-3300-xl-8mm-proximity-probes","title":"Bently Nevada 330105-00-05-10-02-00 3300 XL 8mm Proximity Probes","description":"\u003cp\u003eThe 330105-00-05-10-02-00, also cataloged as the 3300 XL 8mm Proximity Probes, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This sensor system utilizes eddy current technology to facilitate non-contact displacement monitoring. By maintaining a constant gap measurement between the probe tip and the target material, the system transmits precise vibration and axial position data to monitoring instrumentation, including the Bently Nevada 3500 series. The unit is engineered for reverse mount applications, requiring installation from the internal side of the machine housing, and is optimized for deployment on fluid-film bearings, high-speed compressors, and thermal expansion monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330105\u003c\/strong\u003e: 3300 XL 8mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: 3\/8-24 UNF threads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: 0.5 inch case length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: 1.0 meter (3.3 feet) total length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval (Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330105-00-05-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.0 x 30.0 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Processing and Vibration Analysis\u003c\/h3\u003e\n\u003cp\u003eThe 330105-00-05-10-02-00 is calibrated for eddy current probe scaling within the 3300 XL transducer system. The system requires a -24 VDC supply provided by the Proximitor sensor. Proper operation necessitates monitoring the gap voltage, typically set to -10 VDC mid-range to ensure linear response for rotor dynamics analysis. This sensor provides the fundamental input for detecting shaft orbital motion, axial displacement, and radial vibration. The integrity of the signal processing chain relies on the ClickLoc connector, which maintains low contact resistance and minimizes signal attenuation in environments characterized by high-frequency machinery oscillation.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330105-00-05-10-02-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Installation and Setup Manual\u003c\/li\u003e\n\u003cli\u003e1 x Product Certification and Conformity Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Site Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the probe is threaded into the machine housing using the 3\/8-24 UNF threads.\u003c\/li\u003e\n\u003cli\u003eApply a torque of 5.6 Nm to secure the probe, ensuring the housing remains free from structural stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRoute coaxial cables through grounded metallic conduits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain the integrity of the ClickLoc connector by ensuring no tension is applied to the cable junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Clearance\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eObserve a minimum radial clearance of 3 times the probe tip diameter from surrounding metallic obstructions.\u003c\/li\u003e\n\u003cli\u003eVerify the gap voltage using a digital voltmeter during the final alignment process to ensure the sensor is centered within its linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330105 probe require calibration with the extension cable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 330105-00-05-10-02-00 is calibrated as a system including the probe, extension cable, and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be used in high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip and stainless steel case are designed to withstand high-pressure fluid environments common in industrial compressors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector provides a vibration-resistant, repeatable electrical connection that maintains signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically insulated from the machine housing via the mounting bracket to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can I replace the probe without replacing the Proximitor?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new probe has the same physical and electrical specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length supported for this model?\u003c\/p\u003e\n\u003cp\u003eA: This model includes a 1.0 meter integral cable; system length is determined by the total length including the specific extension cable chosen.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe detect shaft vibration?\u003c\/p\u003e\n\u003cp\u003eA: It measures the change in eddy current density as the gap between the probe tip and the shaft surface fluctuates.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762377389,"sku":"330105-00-05-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-00-05-10-02-00-3300-xl-cable-4bgb1pk3oij.jpg?v=1766977053"},{"product_id":"330105-02-12-05-02-00-bently-nevada-3300-xl-extension-cable","title":"330105-02-12-05-02-00 Bently Nevada 3300 XL Extension Cable","description":"\u003cp\u003eConfigured for signal transmission between 8mm proximity probes and Proximitor sensors in 3300 XL machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical electrical continuity for high-frequency carrier signals.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105-02-12-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis categorized by its specific physical attributes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e02: Cable length (4.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Cable assembly type (Standard cable with connector protectors).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval option (Multiple approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Total length (Includes extension and probe cable summation requirements).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No special options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Hardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mm x 300 mm x 60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCross-Talk Suppression and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system requires precise impedance matching to maintain accuracy in rotor dynamics monitoring. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable assembly is constructed to ensure minimal signal attenuation over the specified length. Proper installation requires verification of the total system length (probe cable plus extension cable) to match the calibration requirements of the Proximitor sensor. In environments with high electromagnetic interference, the cable shield must be grounded at the monitor end to prevent noise injection and ensure effective cross-talk suppression between adjacent sensor channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330105-02-12-05-02-00 Extension Cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector kit (pre-installed).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Deployment Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Integrity\u003c\/strong\u003e: Ensure all ClickLoc connectors are fully seated and tightened by hand. Do not use pliers or wrenches, as over-tightening can damage the connector shell.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius\u003c\/strong\u003e: Maintain a minimum bend radius of 25 mm. Exceeding this limit will cause changes to cable impedance and degrade the measurement signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: The cable shield must be continuous. Avoid clamping the cable in areas with high vibration that could induce fretting corrosion on the shield or center conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparation\u003c\/strong\u003e: Route signal cables away from AC power lines and high-current motor leads to prevent induced noise on the vibration signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be trimmed to match a specific system length?\u003c\/p\u003e\n\u003cp\u003eA: No. Trimming or splicing 3300 XL extension cables alters the electrical impedance, which invalidates the system calibration and results in measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable compatible with 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is limited to 3300 XL components. Verify the connector type (ClickLoc) matches the existing probe and Proximitor sensor assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum total system length allowed?\u003c\/p\u003e\n\u003cp\u003eA: The standard 3300 XL system is calibrated for a total length of 5 meters or 9 meters. Ensure the extension cable selection aligns with the Proximitor sensor's calibrated length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the connector protector important?\u003c\/p\u003e\n\u003cp\u003eA: It provides environmental sealing and prevents the ClickLoc connection from loosening due to machine vibration, ensuring a stable electrical path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this cable carry a DC voltage?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it transmits the DC bias voltage and the high-frequency AC carrier signal required for eddy-current proximity sensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I test the cable for continuity?\u003c\/p\u003e\n\u003cp\u003eA: Use a high-impedance ohmmeter to check the center conductor and the shield for continuity. Ensure there is no short-circuit between the center conductor and the shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this cable in sub-zero environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cable materials are rated for operation down to -51 deg C. Avoid manipulating the cable at these temperatures to prevent jacket cracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What does the '02' length code represent?\u003c\/p\u003e\n\u003cp\u003eA: In this configuration, the '02' designates a 4-meter extension cable intended to work with a 1-meter probe cable to achieve a 5-meter total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762410157,"sku":"330105-02-12-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-02-12-05-02-00-extension-cable-wxrnfc5g3lm.jpg?v=1766977055"},{"product_id":"330105-02-12-10-02-05-bently-nevada-3300-xl-series-proximity-probe","title":"330105-02-12-10-02-05 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contact shaft vibration and position displacement measurements across 3300 XL Transducer System platforms. Operating via high-frequency eddy-current generation, the hardware tracks static and dynamic surface distance changes relative to an 8 mm unshielded tip. The sensor interfaces directly with a matching Proximitor module to deliver linear voltage modulation without physical contact with the rotating shaft.\u003c\/p\u003e\n\u003ch3\u003eOption Codes \u0026amp; Structural Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330105\u003c\/strong\u003e: Base model designation for 3300 XL 8 mm proximity probe configuration with standard 3\/8-24 UNF-2A casing threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Unthreaded length option mapping to a 0.2 inch smooth, unthreaded outer body section.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Overall case length option mapping to a 1.2 inch total threaded plus unthreaded shell length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total cable length option specifying a 1.0 meter (3.3 feet) integrated coaxial line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector configuration lacking an integrated connector protector sleeve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency approval option indicating international certifications including CSA, ATEX, and IECEx intrinsic safety and non-incendive approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.0 cm x 18.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor element; current draw managed through the external loop Proximitor (-17.5 VDC to -26 VDC, 12 mA maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Measurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) total displacement tracking window\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when measured against calibrated AISI 4140 steel target\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStructural Casing Threads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Insulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS) engineered polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCasing Shell Composition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 or 304 stainless steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Output Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Ohm nominal RF characteristic transmission impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe probe coil is engineered to establish strict eddy-current probe scaling baselines when paired with an active Proximitor circuit. Field calibration tracking relies on accurate gap voltage validation, requiring the physical positioning to hit a targeted -10 VDC center-point voltage, which marks the exact midpoint of the 80 mil measurement span.\u003c\/p\u003e\n\u003cp\u003eThe tip coil architecture incorporates specialized winding methods to ensure cross-talk suppression. This mitigates radio frequency field overlapping when multiple 3300 XL sensors are mounted together inside tight clearances for orthogonal X-Y radial vibration analysis or redundant thrust positioning, preserving signal fidelity across demanding rotor dynamics transitions.\u003c\/p\u003e\n\u003ch3\u003eOrdering \u0026amp; Shipment Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330105-02-12-10-02-05 proximity probe with integral 1.0 meter low-loss cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory-crimped miniature coaxial ClickLoc plug connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 External hex locknut matched to the 3\/8-24 UNF casing thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Framework\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Torquing Limits\u003c\/strong\u003e: Tighten the 3\/8-24 UNF case to a standard value of 4.5 N-m (40 in-lbf). Do not exceed a maximum limit of 13.6 N-m (120 in-lbf) to prevent structural casing distortion or internal wiring shear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Routing Regulations\u003c\/strong\u003e: Route all integral 1.0 meter lines inside dedicated, separate grounded metallic conduits to shield the high-frequency measurement loop from variable frequency drive or motor power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Bend Constraints\u003c\/strong\u003e: Maintain a strict minimum physical bend radius of 25.4 mm (1.0 inch) across all sections of the coaxial cable to avoid structural damage or signal impedance shifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific gap voltage validation target is required during sensor commissioning?\u003c\/p\u003e\n\u003cp\u003eThe probe position must be mechanically adjusted until the Proximitor loop monitors a stable baseline gap voltage of -10 VDC, centering the operational state in the linear region.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe be hot-swapped while the Proximitor sensor is energized?\u003c\/p\u003e\n\u003cp\u003eYes, the sensor is completely passive and allows hot-swap actions. Disconnecting the coaxial line drives the output to saturation but causes no damage to the electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat total system length extension cable must be paired with this 1.0 meter probe?\u003c\/p\u003e\n\u003cp\u003eA 1.0 meter probe requires matching with a 4.0 meter extension cable to reach the 5.0 meter total loop length required by standard 5 meter Proximitor sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do non-magnetic or alternate shaft metallurgies affect the eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eAlternative shaft materials alter the magnetic reluctance, shifting the scale factor away from the native 200 mV\/mil specification and requiring system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the mechanical function of the 02 unthreaded length parameter?\u003c\/p\u003e\n\u003cp\u003eThe 0.2 inch unthreaded section prevents the probe threads from binding against the internal sleeve entry wall, allowing clean positioning adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical issues occur if the maximum installation torque of 13.6 N-m is exceeded?\u003c\/p\u003e\n\u003cp\u003eExcessive torque deforms the stainless steel body casing, leading to fractured solder joints inside the core coil winding or coaxial junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 05 option suffix modify the physical design or electrical properties of the probe tip?\u003c\/p\u003e\n\u003cp\u003eNo, the 05 suffix indicates international regulatory approvals for hazardous zones. The underlying physical and electrical tracking characteristics remain identical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the measurement loop if the coaxial cable is bent past the 25.4 mm limit?\u003c\/p\u003e\n\u003cp\u003eBending past the limit creates mechanical stress that alters the characteristic coaxial impedance, inducing measurement noise or localized calibration drift errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762442925,"sku":"330105-02-12-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-02-12-10-02-05-vibration-probe-dbnkwsa2b5r.jpg?v=1766977055"},{"product_id":"330105-02-12-10-02-cn-bently-nevada-3300-xl-series-proximity-probe","title":"330105-02-12-10-02-CN Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contact shaft vibration and position displacement measurements across 3300 XL Transducer System platforms. The hardware measures high-frequency magnetic field alterations created by Eddy currents on a target shaft surface. It converts physical distance variations into an analog electrical signal without making physical contact with the machine rotor.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Vector \u0026amp; Suffix Codes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330105\u003c\/strong\u003e: Base model designation for a 3300 XL 8 mm proximity probe configuration with 3\/8-24 UNF threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Unthreaded length configuration option mapping to 0.2 inches of smooth barrel length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Overall case length option mapping to 1.2 inches of total housing structure length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total cable length option specifying a 1.0 meter (3.3 feet) integrated coaxial connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector configuration without an integrated connector protector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Suffix identifying regulatory compliance and approvals issued by NEPSI for localized hazardous zone deployment within China.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.0 cm x 18.5 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHandled entirely by connected Proximitor module (-17.5 VDC to -26 VDC loop power, 12 mA maximum current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActive Measurement Span\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) total linear range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Calibration Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) voltage output tracking shift\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Mechanical Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A outer casing thread size\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensing Tip Polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS) engineered formulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBody Structural Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 or 304 stainless steel sleeve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Validation \u0026amp; Rotor Dynamics Tracking\u003c\/h3\u003e\n\u003cp\u003eThe transducer mechanism functions via high-frequency magnetic field coupling to establish native eddy-current probe scaling baselines. Absolute positioning adjustments during device installation require gap voltage validation, aiming for a targeted stable offset voltage of -10 VDC to lock the static operational posture at the geometric midpoint of the 80 mil linear window.\u003c\/p\u003e\n\u003cp\u003eThe tip coil architecture provides physical cross-talk suppression. This layout prevents electromagnetic field leakage between adjacent 3300 XL sensors, allowing tight-proximity installation configurations when checking complex X-Y orthogonal shaft motion trends or high-velocity rotor dynamics behaviors.\u003c\/p\u003e\n\u003ch3\u003ePackaging Configuration Listing\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330105-02-12-10-02-CN proximity probe assembly with integrated 1.0 meter lead line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory-fitted miniature coaxial ClickLoc termination point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Hexagonal locknut matched to the 3\/8-24 UNF thread structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOn-Site Installation Mandates\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Torquing Limits\u003c\/strong\u003e: Tighten the 3\/8-24 UNF housing shell to a baseline value of 4.5 N-m (40 in-lbf). Do not exceed a maximum of 13.6 N-m (120 in-lbf) to protect internal coaxial solder connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Routing Requirements\u003c\/strong\u003e: Run all integral 1.0 meter lines inside dedicated, separate grounded steel conduits to avoid radio frequency or electrostatic interference from motor driving blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBending Radius Constraints\u003c\/strong\u003e: Maintain a strict minimum physical bend radius of 25.4 mm (1.0 inch) during final structural cable layout to avoid disrupting coaxial signal impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat target gap voltage must be maintained when locking down the physical installation position?\u003c\/p\u003e\n\u003cp\u003eThe probe must be mechanically adjusted until the Proximitor loop monitors a gap voltage validation value of -10 VDC, marking the precise linear midpoint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it possible to complete a sensor hot-swap when the Proximitor module is active?\u003c\/p\u003e\n\u003cp\u003eYes, the sensor is completely passive and allows hot-swap actions. Disconnecting the ClickLoc line triggers an open-circuit fault but inflicts no hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat total system length constraint matches this 1.0 meter probe variant?\u003c\/p\u003e\n\u003cp\u003eA 1.0 meter probe requires matching with a 4.0 meter extension cable to function cleanly with a standard 5.0 meter tuned Proximitor sensor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do non-standard shaft steel formulations change the system scaling response?\u003c\/p\u003e\n\u003cp\u003eAlternative shaft materials alter the eddy-current probe scaling, causing deviations from the native 200 mV\/mil output sensitivity profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat problem does the 0.2 inch unthreaded length option prevent?\u003c\/p\u003e\n\u003cp\u003eThe 0.2 inch unthreaded section prevents the probe threads from binding against the internal sleeve entry wall, allowing clean positioning adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CN designation change the physical layout or response curves of the probe tip?\u003c\/p\u003e\n\u003cp\u003eNo, the CN suffix solely documents official regional NEPSI hazardous area safety approvals. The underlying hardware design is unchanged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat damage occurs if the structural torque ceiling of 13.6 N-m is exceeded?\u003c\/p\u003e\n\u003cp\u003eExcessive torque deforms the stainless steel body casing, leading to fractured solder joints inside the core coil winding or coaxial junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the sensor tip handle high pressure differentials across the casing wall?\u003c\/p\u003e\n\u003cp\u003eThe sensor assembly is sealed with an internal Viton barrier, though it is intended for machine case oil mist containment rather than high-pressure process sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762508461,"sku":"330105-02-12-10-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-02-12-10-02-cn-proximity-model-seyncfcgsvi.jpg?v=1766977057"},{"product_id":"330105-02-12-15-02-cn-bently-nevada-3300-xl-series-proximity-probe","title":"330105-02-12-15-02-CN Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330105-02-12-15-02-CN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contact shaft vibration and position displacement measurements within 3300 XL Proximity Transducer System platforms. The sensor maps mechanical target proximity to a proportional radio-frequency electrical output signal via an unshielded 8 mm tip structure. It tracks dynamic oil-film clearance variations and static axial rotor alignment changes relative to the stationary machine casing structure.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Options \u0026amp; Part Numbering Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330105\u003c\/strong\u003e: Base model definition for a standard 3300 XL 8 mm proximity probe with 3\/8-24 UNF English threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Unthreaded length option specifying 0.2 inches of smooth, unthreaded barrel length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Overall case length option specifying 1.2 inches of total threaded plus unthreaded body length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15\u003c\/strong\u003e: Total length configuration establishing a 1.5 meter (4.9 feet) integrated low-loss cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector configuration without an integrated connector protector sleeve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Certification suffix indicating validation by NEPSI for installation in hazardous area environments within China.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330105-02-12-15-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.5 cm x 18.0 cm x 4.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor element powered via Proximitor drive loop (-17.5 VDC to -26 VDC, 12 mA max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal tracking span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) when calibrated against an AISI 4140 steel target\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A mechanical mounting thread configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Construction Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS) high-temperature engineered polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Construction Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 or 304 stainless steel housing shell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm hardware utilizes a high-frequency radio frequency field to establish eddy-current probe scaling profiles that match the target metallurgy. System loop calibration relies on gap voltage validation, where a baseline target of -10 VDC marks the geometric midpoint of the 80 mil operational linear range.\u003c\/p\u003e\n\u003cp\u003eThe proximity sensor winding architecture features integrated cross-talk suppression. This electrical insulation prevents magnetic field overlapping when multiple probes are mounted at close proximity for orthogonal X-Y shaft orbit diagnostics or redundant thrust fault monitoring, preserving absolute signal accuracy during extreme rotor dynamics transitions.\u003c\/p\u003e\n\u003ch3\u003ePackaging Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330105-02-12-15-02-CN proximity probe containing an integral 1.5 meter cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Miniature coaxial ClickLoc plug connector terminated at the cable end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Removable locknut matching the 3\/8-24 UNF mechanical thread profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Routing Instructions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Insertion Torquing Limits\u003c\/strong\u003e: Do not exceed the absolute structural torque threshold of 13.6 N-m (120 in-lbf) during installation into the probe bracket. The recommended installation torque is 4.5 N-m (40 in-lbf).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit Routing Requirements\u003c\/strong\u003e: Route the 1.5 meter integral cable assembly through dedicated, grounded metallic conduits to shield the high-frequency measurement loop from variable frequency drive or motor power cable noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Bend Constraints\u003c\/strong\u003e: Maintain a strict minimum physical bend radius of 25.4 mm (1.0 inch) for all permanent coaxial cable installations to prevent internal dielectric layer damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the specific target gap voltage value required during hardware installation calibration?\u003c\/p\u003e\n\u003cp\u003eThe initial alignment requires a gap voltage calibration target of -10 VDC, corresponding to the center of the sensor linear tracking boundary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe be hot-swapped while the driver circuit is powered?\u003c\/p\u003e\n\u003cp\u003eYes, the passive coaxial line supports hot-swapping. Disconnecting the connector drives the Proximitor output to saturation but causes no component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard total system length requirement for a 1.5 meter probe configuration?\u003c\/p\u003e\n\u003cp\u003eA 1.5 meter probe must be matched with a 3.5 meter extension cable to function correctly with a standard 5.0 meter Proximitor sensor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does an alternate target material impact the factory-set eddy-current scaling?\u003c\/p\u003e\n\u003cp\u003eCalibrated for AISI 4140 steel, alternate metals change the magnetic reluctance, shifting the scale factor away from the native 200 mV\/mil specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the mechanical function of the 02 unthreaded length parameter?\u003c\/p\u003e\n\u003cp\u003eThe 0.2 inch unthreaded section prevents internal thread binding against the mounting adapter wall, easing the depth-positioning process during bracket installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the CN designation alter the electrical parameters of the proximity sensor?\u003c\/p\u003e\n\u003cp\u003eThe CN suffix indicates NEPSI certification for hazardous environments in China. It introduces no modifications to the underlying electrical or mechanical circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the measurement loop if the coaxial cable is bent past the 25.4 mm limit?\u003c\/p\u003e\n\u003cp\u003eBending past the limit creates mechanical stress that alters the characteristic coaxial impedance, inducing measurement noise or localized calibration drift errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external voltage supply wired directly into the probe connector?\u003c\/p\u003e\n\u003cp\u003eNo, the probe is passive and receives its radio-frequency excitation signal directly from the connected Proximitor sensor module over the coaxial network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762672301,"sku":"330105-02-12-15-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330105-02-12-15-02-cn-proximitor-sensor-s5p2w0ob4nn.jpg?v=1766977058"},{"product_id":"330106-05-30-05-02-cn-bently-nevada-3300-xl-series-reverse-mount-proximity-probe","title":"330106-05-30-05-02-CN Bently Nevada 3300 XL Series Reverse Mount Proximity Probe","description":"\u003cp\u003eConfigured for non-contact shaft displacement sensing within machinery diagnostic platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330106-05-30-05-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330106\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReverse Mount Proximity Probe) provides direct physical\/electrical execution. While procurement listings sometimes index this part designation under extension cable classifications due to its integrated coaxial line, the 330106 catalog sequence designates a complete reverse-mount eddy-current probe containing an integrated transducer lead. The component generates a continuous electrical voltage output that scales directly with the mechanical distance between the probe tip face and a rotating conductive target.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration Matrix\u003c\/h3\u003e\n\u003ch3\u003eSuffix Nomenclature\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330106\u003c\/strong\u003e: Base configuration for the 3300 XL 8 mm reverse mount proximity probe built with M10 x 1 metric threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Unthreaded length option representing 0.5 inches of smooth case section.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e30\u003c\/strong\u003e: Overall case length option representing 3.0 inches of total housing structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total length option establishing a 0.5 meter (1.6 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector design without structural connector insulation sleeves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Chinese NEPSI hazardous area certification and regulatory compliance framework approval code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensional and Electrical Attributes\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330106-05-30-05-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 cm x 18.0 cm x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnder 12 mA supplied via continuous -24 VDC Proximitor loop infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal tracking boundary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) electrical tracking output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1 metric mechanical pitch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Insulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS) high-performance polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Transducer Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer hardware works through high-frequency eddy-current field generation to map minute position changes. System calibration relies on accurate gap voltage validation, requiring a target setting of -10 VDC to position the operational state precisely at the center of the 80 mil linear window.\u003c\/p\u003e\n\u003cp\u003eThe physical construction integrates optimized cross-talk suppression geometries. This optimization allows multi-probe arrays to track complex rotor dynamics across close-range X-Y orthogonal planes without mutual electromagnetic interference or signal degradation.\u003c\/p\u003e\n\u003ch3\u003eBill of Materials\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330106-05-30-05-02-CN reverse mount probe assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory-terminated miniature coaxial ClickLoc electrical interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Integral 0.5 meter low-loss RF transmission cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Framework\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Torquing Bounds\u003c\/strong\u003e: Tighten the metric reverse mount body within a range of 7.5 N-m (66 in-lbf) standard to a maximum limit of 22.6 N-m (200 in-lbf).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing Mandates\u003c\/strong\u003e: Isolate the 0.5 meter integrated line inside dedicated grounded conduits to block external induction paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius Limits\u003c\/strong\u003e: Observe a strict 25.4 mm (1.0 inch) minimum bend radius constraint across all cable positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific mechanical target is required to achieve the nominal 200 mV\/mil scale factor?\u003c\/p\u003e\n\u003cp\u003eThe sensor performance is factory-calibrated against a standard AISI 4140 steel target. Alternate shaft materials alter the scale factor and require system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the CN suffix alter within the hardware structure?\u003c\/p\u003e\n\u003cp\u003eThe CN suffix does not change the internal sensor circuitry. It indicates compliance testing and official certification for installation under Chinese NEPSI hazardous area conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this 0.5 meter integrated probe cable link directly to a 9 meter Proximitor sensor?\u003c\/p\u003e\n\u003cp\u003eNo, a 0.5 meter probe must be combined with an 4.5 meter extension cable to reach the 5.0 meter system length required by the standard 5 meter Proximitor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the miniature ClickLoc coaxial connection be insulated inside a machine housing?\u003c\/p\u003e\n\u003cp\u003eUse a dedicated connector silicone sleeve or specialized insulation tubing to prevent the exposed coaxial outer shell from grounding against metal machinery parts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat behavior occurs if the probe tip comes into direct contact with the spinning shaft?\u003c\/p\u003e\n\u003cp\u003ePhysical contact destroys the PPS plastic tip molding and internal coil assembly, causing the Proximitor loop output voltage to drop to its lower saturation limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the 0.5 inch unthreaded length option code?\u003c\/p\u003e\n\u003cp\u003eThe unthreaded length allows safe insertion through specific machine port clearances, preventing thread binding inside the entry wall during reverse mount installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe assembly support standard hot-swapping during active machinery operation?\u003c\/p\u003e\n\u003cp\u003eYes, the passive coaxial line can be disconnected or connected while the Proximitor is powered. The monitoring system will register a temporary open-circuit fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat indicates an out-of-tolerance gap installation during commissioning?\u003c\/p\u003e\n\u003cp\u003eIf the static DC voltage measured at the Proximitor output terminal deviates significantly from the -10 VDC center point, the probe position must be mechanically readjusted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762868909,"sku":"330106-05-30-05-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330106-05-30-05-02-cn-extension-cable-nt1kiqt3rug.jpg?v=1766977060"},{"product_id":"330106-05-30-20-02-05-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330106-05-30-20-02-05 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330106-05-30-20-02-05 is an armored extension cable for the 3300 XL 8 mm proximity transducer system. It is used to connect the proximity probe to the Proximitor sensor, preserving the eddy-current signal quality required for accurate non-contact measurement of shaft vibration and shaft position.\u003c\/p\u003e\n\u003cp\u003eIn rotating machinery monitoring, the extension cable is a functional part of the calibrated transducer system. Correct cable selection helps maintain stable scaling, minimizes noise pickup, and supports reliable trending of radial vibration and axial position. This enables earlier identification of developing mechanical issues such as rotor unbalance, misalignment, rub conditions, and bearing wear.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e330106-05-30-20-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity system extension cable (armored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eProbe-to-Proximitor interconnection for eddy-current systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eCoaxial, low-loss signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Style\u003c\/td\u003e\n\u003ctd\u003eClickLoc quick-connect, vibration-resistant coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eFluid-tight electronic armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Cable Length\u003c\/td\u003e\n\u003ctd\u003e2.0 m (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEngineering notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExtension cable length is part of the proximity system calibration. Confirm the full system length (probe + extension cable) matches the selected Proximitor sensor and monitor configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse proper routing and clamping to avoid sharp bends, pinch points, and high-energy electrical noise sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eTypical installations include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines for radial vibration and thrust position measurement (depending on probe mounting)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors in oil, gas, and chemical plants where stable displacement signals support protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoiler feed pumps and critical process pumps where early vibration change reduces seal and bearing damage risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed motors, generators, and fans where non-contact sensors are preferred for reliability in harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOperational considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain the specified minimum bend radius and protect connectors from impact during maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify connector engagement and continuity during commissioning to prevent intermittent signal faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep transducer wiring separated from variable frequency drive outputs and high-current conductors where possible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518762934445,"sku":"330106-05-30-20-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330106-05-30-20-02-cn-proximity-probe-zxa2uqwtaoj.jpg?v=1766977061"},{"product_id":"bently-nevada-330103-02-12-10-02-00-3300-xl-8mm-proximity-probes","title":"Bently Nevada 330103-02-12-10-02-00 3300 XL 8mm Proximity Probes","description":"\u003cp\u003eThe 330103-02-12-10-02-00, also cataloged as the 3300 XL 8mm Proximity Probes, serves as a primary non-contact sensor for monitoring vibration and axial position in industrial machinery. Utilizing eddy current technology, this probe measures the gap between its tip and a rotating shaft, providing precise data for the Bently Nevada 3500 monitoring system. Engineered for standard mount installation, it is designed for critical asset protection in high-speed compressors, fluid-film bearings, and turbine monitoring architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL 8mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: 3\/8-24 UNF threads (without armor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12\u003c\/strong\u003e: 1.2 inch case length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: 1.0 meter (3.3 feet) total length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval (Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Overview\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-02-12-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.0 x 30.0 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Processing and Vibration Analysis\u003c\/h3\u003e\n\u003cp\u003eThe 330103-02-12-10-02-00 is calibrated for eddy current probe scaling within the 3300 XL transducer system. The system requires a -24 VDC supply provided by the Proximitor sensor. Proper operation necessitates monitoring the gap voltage, typically set to -10 VDC mid-range to ensure linear response for rotor dynamics analysis. This sensor provides the fundamental input for detecting shaft orbital motion, axial displacement, and radial vibration. The integrity of the signal processing chain relies on the ClickLoc connector, which maintains low contact resistance and minimizes signal attenuation in environments characterized by high-frequency machinery oscillation.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330103-02-12-10-02-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Installation and Setup Manual\u003c\/li\u003e\n\u003cli\u003e1 x Product Certification and Conformity Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Site Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the probe is threaded into the machine housing using the 3\/8-24 UNF threads.\u003c\/li\u003e\n\u003cli\u003eApply a torque of 5.6 Nm to secure the probe, ensuring the housing remains free from structural stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRoute coaxial cables through grounded metallic conduits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain the integrity of the ClickLoc connector by ensuring no tension is applied to the cable junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Clearance\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eObserve a minimum radial clearance of 3 times the probe tip diameter from surrounding metallic obstructions.\u003c\/li\u003e\n\u003cli\u003eVerify the gap voltage using a digital voltmeter during the final alignment process to ensure the sensor is centered within its linear range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330103 probe require calibration with the extension cable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 330103-02-12-10-02-00 is calibrated as a system including the probe, extension cable, and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be used in high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip and stainless steel case are designed to withstand high-pressure fluid environments common in industrial compressors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector provides a vibration-resistant, repeatable electrical connection that maintains signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically insulated from the machine housing via the mounting bracket to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can I replace the probe without replacing the Proximitor?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new probe has the same physical and electrical specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length supported for this model?\u003c\/p\u003e\n\u003cp\u003eA: This model includes a 1.0 meter integral cable; system length is determined by the total length including the specific extension cable chosen.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe detect shaft vibration?\u003c\/p\u003e\n\u003cp\u003eA: It measures the change in eddy current density as the gap between the probe tip and the shaft surface fluctuates.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807367853,"sku":"330103-02-12-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-02-12-10-02-00-proximity-probe-10rpg3vzzo2.jpg?v=1766979350"},{"product_id":"330103-00-16-10-01-00-bently-nevada-3300-xl-series-proximity-probes","title":"330103-00-16-10-01-00 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eThe 330103-00-16-10-01-00 3300 XL 8mm Proximity Probe serves as a critical component in the Bently Nevada 3300 XL transducer system, designed for high-precision, non-contact measurement of rotor displacement, vibration, and axial position. As a standard-mount sensor utilizing eddy current technology, this probe is engineered for reliable operation within the demanding environments of power generation and hydrocarbon processing facilities. By generating an electromagnetic field that detects fluctuations in the gap between the probe tip and a conductive target, the unit provides high-linearity signal output, ensuring accurate diagnostics for critical turbomachinery protection and performance optimization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-16-10-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e1.6 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.0 x 30.0 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModel Configuration Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330103: 3300 XL 8mm Proximity Probe.\u003c\/li\u003e\n\u003cli\u003e00: Unarmored probe (Standard configuration for typical machine installations).\u003c\/li\u003e\n\u003cli\u003e16: 1.6-inch case length, allowing for specific mounting depth requirements in industrial housings.\u003c\/li\u003e\n\u003cli\u003e10: 1.0-meter integral cable length, providing sufficient reach for connection to the extension cable system.\u003c\/li\u003e\n\u003cli\u003e01: Miniature ClickLoc connector with terminal protector (Standard).\u003c\/li\u003e\n\u003cli\u003e00: Agency Approval (Standard, non-hazardous area rated).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThis sensor is widely implemented across the energy sector for the surveillance of rotating equipment. Key applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRadial Vibration Monitoring: Detecting mechanical instability in fluid-film bearings on large steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eAxial Thrust Position: Measuring rotor movement to prevent catastrophic contact between turbine blades and stationary housings.\u003c\/li\u003e\n\u003cli\u003eEccentricity Detection: Monitoring shaft bending during start-up or thermal transition phases in large compressors.\u003c\/li\u003e\n\u003cli\u003eKeyphasor Signal Acquisition: Providing precise speed and phase angle data for diagnostic vector analysis on pump and motor shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 330103-00-16-10-01-00 is fully compatible with the Bently Nevada 3300 XL Proximitor sensor and associated extension cables. The system must be calibrated as a complete loop to maintain the specified output of 7.87 V\/mm (200 mV\/mil). It is natively integrated into the Bently Nevada 3500 Monitoring System, allowing for seamless connectivity with existing digital racks, backplane communications, and automated machinery shutdown logic (SIS\/ESD).\u003c\/p\u003e\n\u003ch3\u003eInstallation and Site Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical Mounting:\n\u003cul\u003e\n\u003cli\u003eEnsure the probe mounting bracket is rigid to avoid resonance.\u003c\/li\u003e\n\u003cli\u003eUse a torque wrench on the 3\/8-24 threads; do not exceed 5.6 Nm to maintain case integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Shielding:\n\u003cul\u003e\n\u003cli\u003eRoute cables through dedicated rigid steel conduits.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum distance of 15 cm from high-voltage AC lines to prevent induced noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnector Integrity:\n\u003cul\u003e\n\u003cli\u003eInspect the gold-plated ClickLoc pins for contamination.\u003c\/li\u003e\n\u003cli\u003eEnsure a secure lock with a tactile click; verify connection with an ohmmeter if high signal noise is observed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnvironmental Protection:\n\u003cul\u003e\n\u003cli\u003eUtilize thread sealant compatible with specific process lubricants to prevent housing leakage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 330103 series is recognized for its stable frequency response and resistance to industrial interference. The PPS tip provides excellent chemical resistance against reactive lubricants, while the robust 304 stainless steel case offers durability in high-vibration scenarios. Its design specifically minimizes the risk of signal loss, which is essential for maintaining high Overall Equipment Effectiveness (OEE) and preventing unplanned turbine downtime.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Package: 1 x 330103-00-16-10-01-00 Probe, Technical Documentation.\u003c\/li\u003e\n\u003cli\u003eNote: Extension cables and Proximitor sensors are ordered separately to ensure the correct system length (e.g., 5-meter or 9-meter systems).\u003c\/li\u003e\n\u003cli\u003eAccessories: Threaded mounting adapters, internal mounting brackets, and connector protection sleeves are available upon request for specific installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used to replace a legacy 3300 series probe?\u003c\/p\u003e\n\u003cp\u003eA: Generally, yes. However, system re-calibration or Proximitor replacement may be required to maintain linear accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this probe require special shielding?\u003c\/p\u003e\n\u003cp\u003eA: Standard industrial practice is to route the probe cable through dedicated metallic conduit to minimize electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum distance between the probe and the Proximitor?\u003c\/p\u003e\n\u003cp\u003eA: The system is designed to operate with specific cable lengths. Ensure the combined length of the integral and extension cable matches the Proximitor's calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the ClickLoc connector waterproof?\u003c\/p\u003e\n\u003cp\u003eA: It is designed for industrial environments but should be protected with a sleeve or junction box to prevent direct fluid ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How often should the probe be replaced?\u003c\/p\u003e\n\u003cp\u003eA: Replacement intervals depend on operating conditions; periodic voltage checks (gap voltage) are recommended during outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with the 3500 system?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is fully compatible with all 3500 series vibration monitoring modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the cable be shortened?\u003c\/p\u003e\n\u003cp\u003eA: No. Altering the cable length will change the system's impedance and invalidate the calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the benefit of the PPS tip?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip provides chemical inertness and stable performance in high-pressure, high-temperature lubrication environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807400621,"sku":"330103-00-16-10-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-16-10-01-00-extension-cable-n1p1imbfejj.jpg?v=1766979351"},{"product_id":"330101-00-25-20-12-00-bently-nevada-3300-xl-series-proximity-probes","title":"330101-00-25-20-12-00 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330101-00-25-20-12-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330101\u003c\/strong\u003e 8 mm Proximity Probes, serves as the primary transducer utilized to execute non-contact displacement and vibration monitoring across 3300 XL system platforms. This hardware component processes shaft position and vibration data by sensing the eddy current fluctuation between the probe tip and the monitored metallic target. It functions as the input stage for signal conditioning within rotating machinery protection architectures, delivering a precise, linear voltage output relative to the target gap distance for downstream monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330101: 3300 XL 8 mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e00: Unarmored probe construction\u003c\/li\u003e\n\u003cli\u003e25: 2.5 inch case length\u003c\/li\u003e\n\u003cli\u003e20: 2.0 meter total system length\u003c\/li\u003e\n\u003cli\u003e12: Miniature coaxial ClickLoc connector with terminal protector\u003c\/li\u003e\n\u003cli\u003e00: Standard agency approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-25-20-12-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e35.0 x 30.0 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on Proximitor supply (-24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTransducer Signal Dynamics and Rotor Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 330101-00-25-20-12-00 requires precise eddy-current probe scaling to ensure linear response within the 3300 XL system. Proper gap voltage validation is necessary during installation; technicians must target a mid-range value of -10 VDC to optimize the linear operating range for rotor dynamics analysis. The system is designed to suppress cross-talk by maintaining specific high-frequency carrier signal synchronization between the probe and the Proximitor. Any deviation in the -10 VDC setpoint indicates improper probe positioning or surface irregularities, which may affect the accuracy of detecting shaft orbital motion or axial thrust displacement.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330101-00-25-20-12-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Product Technical Manual\u003c\/li\u003e\n\u003cli\u003e1 x Certificate of Conformity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical Mounting:\n\u003cul\u003e\n\u003cli\u003eEnsure the probe is installed using non-conductive mounting brackets to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eObserve a minimum clearance of 3 times the probe tip diameter from surrounding metallic obstructions.\u003c\/li\u003e\n\u003cli\u003eSecure the 3\/8-24 UNF threads with a maximum torque of 5.6 Nm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWiring and Shielding:\n\u003cul\u003e\n\u003cli\u003eRoute all coaxial cabling within dedicated metallic conduits to maintain electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003eMinimize cable bending; maintain a minimum bend radius of 50 mm to preserve the internal coaxial geometry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eConnector Integrity:\n\u003cul\u003e\n\u003cli\u003eVerify that the ClickLoc connector is fully seated until a tactile lock is achieved.\u003c\/li\u003e\n\u003cli\u003eUse protective caps on unused connector interfaces to prevent contamination of the gold-plated pins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the 330101 probe require specific Proximitor matching?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the system (probe, extension cable, and Proximitor) must be calibrated as a matched set to maintain 200 mV\/mil output accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used for high-speed shaft rotation?\u003c\/p\u003e\n\u003cp\u003eA: The transducer supports frequency responses up to 10 kHz, making it suitable for high-speed turbomachinery monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the effect of exceeding the 5.6 Nm mounting torque?\u003c\/p\u003e\n\u003cp\u003eA: Over-torquing can cause physical deformation of the stainless steel case, potentially leading to seal failure or sensitivity degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe tip protected from fluid ingress?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip is chemically inert and mechanically sealed to withstand contact with high-pressure industrial lubricants and process fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the cable length affect the gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: Cable length is integrated into the system impedance; altering the length will shift the linear range and require re-calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe detect vibration in non-ferrous materials?\u003c\/p\u003e\n\u003cp\u003eA: The transducer is calibrated for AISI 4140 steel; using it with non-conductive or different magnetic materials requires specific scaling factors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the ClickLoc connector field-replaceable?\u003c\/p\u003e\n\u003cp\u003eA: The connector is factory-molded for integrity; field repair of the connector or cable assembly is not supported.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the gap voltage target set to -10 VDC?\u003c\/p\u003e\n\u003cp\u003eA: -10 VDC provides the optimal linearity within the 2 mm range, ensuring that peak-to-peak vibration measurements remain within the dynamic limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807498925,"sku":"330101-00-25-20-12-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-25-20-12-00-3300-xl-8-mm-proximity-probes-zkcb14ttjhm.jpg?v=1766979356"},{"product_id":"330104-00-20-10-01-cn-bently-nevada-proximity-probes-3300-xl","title":"330104-00-20-10-01-CN Bently Nevada Proximity Probes 3300 XL","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-20-10-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting shaft displacement and vibration measurements across Bently Nevada 3500 Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Selection Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: 3300 XL 8 mm Proximity Probe, M10 x 1 metric thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-00: 0 mm unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-20: 200 mm overall case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-10: 1.0 meter (3.3 feet) total cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-01: Miniature coaxial ClickLoc connector with coaxial cable protection boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-CN: Approvals configuration certified for regional Chinese safety regulations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-20-10-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 x 15.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Element (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Connector Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc miniature coaxial coupling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis proximity sensor operates on the eddy-current principle to track dynamic shaft behavior and rotor dynamics. The mechanical assembly converts distance parameters into high-frequency RF fields generated by the Proximitor. Field calibration relies on accurate gap voltage validation, targeting a nominal -10 VDC center-scale checkpoint for optimal linearity. Precision tip architecture provides stable eddy-current probe scaling metrics (typically 7.87 V\/mm) while suppressing multi-channel cross-talk in dense radial setups.\u003c\/p\u003e\n\u003ch3\u003eLogistics Dispatch Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330104-00-20-10-01-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Hex Mounting Locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Silicone Protection Boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure bracket mounting achieves rigid thread engagement to eliminate case vibration harmonics that distort true target readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Position Adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjust the mechanical insertion depth until gap voltage validation registers approximately -10 VDC at the monitor rack test points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Isolation Proportions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain an open cylindrical radius of at least 15 mm around the probe tip to prevent target anomalies from surrounding metal walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Coupling Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHand-tighten the ClickLoc miniature coaxial connector; do not use pliers or mechanical tools to avoid crushing internal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe configuration support hot-swap terminal substitution?\u003c\/p\u003e\n\u003cp\u003eYes. The probe can be physically disconnected from the extension cable while the main Proximitor and monitor rack remain energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does structural surface finish affect eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eSurface defects or microstructural variations modify electrical conductivity, altering the calibrated 7.87 V\/mm linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom indicates a failure in gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eA validation reading sitting near 0 VDC or exceeding -18 VDC indicates an open circuit, short circuit, or incorrect mechanical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this model operate with any length of extension cable?\u003c\/p\u003e\n\u003cp\u003eNo. The probe must match the specific system configuration loop length to preserve factory calibration tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk suppression managed when installing two orthogonal probes?\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum axial separation of 40 mm between probe tips when monitoring identical shaft sections to prevent RF interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operating limit of the tip material?\u003c\/p\u003e\n\u003cp\u003eThe PPS fluoropolymer tip holds structural and electrical integrity during continuous thermal exposure up to 177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external isolation barrier required for hazardous area installations?\u003c\/p\u003e\n\u003cp\u003eYes. Intrinsic safety barriers must be wired between the Proximitor sensor loop and the monitoring system rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the coaxial connector boot is omitted in humid conditions?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress increases electrical leakage resistance, causing calibration drift and intermittent channel fault alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807564461,"sku":"330104-00-20-10-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-20-10-01-cn-3300-xl-8-mm-proximity-probes-cdca0eu13zr.jpg?v=1766979357"},{"product_id":"330104-01-08-50-01-cn-bently-nevada-3300-xl-proximity-probes","title":"330104-01-08-50-01-CN Bently Nevada 3300 XL Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-01-08-50-01-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes utilized to execute non-contacting shaft displacement and vibration measurements across Bently Nevada 3500 Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Option Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: 3300 XL 8 mm Proximity Probe, M10 x 1 metric thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-01: 10 mm unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-08: 80 mm overall case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-50: 5.0 meter (16.4 feet) total cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-01: Miniature coaxial ClickLoc connector, fluidic protection braid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-CN: China Ex hazardous area approval certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-01-08-50-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.0 x 18.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Element (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Structure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc coaxial cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis proximity sensor operates on the eddy-current principle to track dynamic shaft behavior and rotor dynamics. The mechanical assembly converts distance parameters into high-frequency RF fields generated by the Proximitor. Field calibration relies on accurate gap voltage validation, targeting a nominal -10 VDC center-scale checkpoint for optimal linearity. Precision tip architecture provides stable eddy-current probe scaling metrics (typically 7.87 V\/mm) while suppressing multi-channel cross-talk in dense radial setups.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330104-01-08-50-01-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Stainless Steel Mounting Locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Silicone Protection Boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Structural Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure bracket mounting achieves rigid thread engagement to eliminate case vibration harmonics that distort true target readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjust the mechanical insertion depth until gap voltage validation registers approximately -10 VDC at the monitor rack test points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Isolation Radius\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain an open cylindrical radius of at least 15 mm around the probe tip to prevent target anomalies from surrounding metal walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Connector Handling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHand-tighten the ClickLoc miniature coaxial connector; do not use pliers or mechanical tools to avoid crushing internal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe configuration support hot-swap terminal substitution?\u003c\/p\u003e\n\u003cp\u003eYes. The probe can be physically disconnected from the extension cable while the main Proximitor and monitor rack remain energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does structural surface finish affect eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eSurface defects or microstructural variations modify electrical conductivity, altering the calibrated 7.87 V\/mm linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom indicates a failure in gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eA validation reading sitting near 0 VDC or exceeding -18 VDC indicates an open circuit, short circuit, or incorrect mechanical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this model operate with any length of extension cable?\u003c\/p\u003e\n\u003cp\u003eNo. The probe must match the specific system configuration, such as a 5.0-meter total system loop length, to preserve calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk suppression managed when installing two orthogonal probes?\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum axial separation of 40 mm between probe tips when monitoring identical shaft sections to prevent RF interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operating limit of the tip material?\u003c\/p\u003e\n\u003cp\u003eThe PPS fluoropolymer tip holds structural and electrical integrity during continuous thermal exposure up to 177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external isolation barrier required for hazardous area installations?\u003c\/p\u003e\n\u003cp\u003eYes. Intrinsic safety barriers must be wired between the Proximitor sensor loop and the monitoring system rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the coaxial connector boot is omitted in humid conditions?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress increases electrical leakage resistance, causing calibration drift and intermittent channel fault alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807728301,"sku":"330104-01-08-50-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-01-08-50-01-cn-proximity-probes-eyyujkwliup.jpg?v=1766979364"},{"product_id":"330103-00-10-05-01-00-bently-nevada-3300-xl-8-mm-series-proximity-probe","title":"330103-00-10-05-01-00 Bently Nevada 3300 XL 8 mm Series Proximity Probe","description":"\u003cp\u003eConfigured for displacement and vibration measurements in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-10-05-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. This non-contacting sensor transduces the dynamic gap between the probe tip and a conductive target into an electrical signal managed by a 3300 XL Proximitor Sensor. The assembly serves as the primary inductive interface for monitoring shaft axial position and radial vibration in rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length option (0.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Overall case length option (1.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total length option (0.5 m \/ 1.6 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Connector and cable option (Miniature coaxial ClickLoc connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (No approvals required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-10-05-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 cm x 20.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm eddy-current probe scaling is factory-calibrated for AISI 4140 steel targets. Successful field deployment requires gap voltage validation (-10 VDC targets) at the Proximitor output terminal to center the probe within its linear sensing envelope. This precise physical alignment facilitates accurate rotor dynamics analysis, including detection of fluid-film bearing instabilities. Cross-talk suppression is maintained by ensuring adequate physical separation between adjacent probe tips, preventing electromagnetic interference between parallel measurement channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330103-00-10-05-01-00 Proximity Probe with 0.5 m integrated coaxial lead wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Connector Protector Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation Technical Document\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Threading and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the probe into the mounting bracket with a minimum of 5 full threads of engagement to ensure rigid mechanical positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the sensor gap until the target voltage is reached, then tighten the locknuts to a terminal torque of 5.1 N-m (45 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnforce a 25.4 mm (1.0 in) minimum bend radius for the coaxial cable to avoid damaging the internal core.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute probe leads within dedicated, grounded metal conduits to provide isolation from AC lines and mitigate EMI-induced signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat baseline gap voltage must be maintained for calibration?\u003c\/p\u003e\n\u003cp\u003eThe probe must be physically gapped until the Proximitor output registers -10 VDC, which corresponds to the linear center of the 80 mil measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be connected directly to a PLC or DCS I\/O card?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive sensor and requires a 3300 XL Proximitor module to convert impedance changes into a scaled -24 VDC output or current signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 0.5 m cable length modifiable in the field?\u003c\/p\u003e\n\u003cp\u003eNo, the cable length is an integral part of the system impedance. Cutting or splicing will corrupt the scale factor and invalidate system accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the factory-calibrated target material?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for AISI 4140 steel. Monitoring different shaft materials will require a non-linear calibration or system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the ClickLoc connection hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the coaxial interface can be disconnected or connected while the system is powered, though a temporary channel fault alarm will occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include outer protective armor?\u003c\/p\u003e\n\u003cp\u003eNo, the 330103-00-10-05-01-00 part number utilizes standard coaxial cabling without stainless steel armor protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does humidity impact the coaxial junction?\u003c\/p\u003e\n\u003cp\u003eMoisture creates parallel leakage paths that skew signal output. Use the provided connector protector or self-fusing silicone tape in humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip is installed too close to the target?\u003c\/p\u003e\n\u003cp\u003eThe probe will enter the non-linear region or physical contact may occur, resulting in measurement saturation or mechanical damage to the probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807892141,"sku":"330103-00-10-05-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-10-05-01-00-sensor-system-0h0sathq2oo.jpg?v=1766979371"},{"product_id":"330104-00-07-05-02-00-bently-nevada-proximity-probe-3300-xl-8-mm-series","title":"330104-00-07-05-02-00 Bently Nevada Proximity Probe 3300 XL 8 mm Series","description":"\u003cp\u003eConfigured for displacement and vibration measurements in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-07-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. This non-contacting sensor transduces the dynamic gap between the probe tip and a conductive target into an electrical signal managed by a 3300 XL Proximitor Sensor. The assembly functions as the primary inductive interface for monitoring shaft position and radial vibration in rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, 1\/4-28 UNF thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length option (0.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07\u003c\/strong\u003e: Overall case length option (0.7 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total length option (0.5 m \/ 1.6 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector and cable option (Miniature coaxial ClickLoc connector with protector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (No approvals required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-07-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 cm x 20.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm eddy-current probe scaling is factory-calibrated for AISI 4140 steel targets. Successful field deployment requires gap voltage validation (-10 VDC targets) at the Proximitor output terminal to center the probe within its linear sensing envelope. This precise physical alignment facilitates accurate rotor dynamics analysis, including detection of fluid-film bearing instabilities. Cross-talk suppression is maintained by ensuring adequate physical separation between adjacent probe tips, which prevents electromagnetic interference between parallel measurement channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330104-00-07-05-02-00 Proximity Probe with 0.5 m integrated coaxial lead wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 1\/4-28 UNF Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Connector Protector Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation Technical Document\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Threading and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the probe into the mounting bracket with a minimum of 5 full threads of engagement to ensure rigid mechanical positioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the sensor gap until the target voltage is reached, then tighten the locknuts to a terminal torque of 5.1 N-m (45 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnforce a 25.4 mm (1.0 in) minimum bend radius for the coaxial cable to avoid damaging the internal core.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute probe leads within dedicated, grounded metal conduits to provide isolation from AC lines and mitigate EMI-induced signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat baseline gap voltage must be maintained for calibration?\u003c\/p\u003e\n\u003cp\u003eThe probe must be physically gapped until the Proximitor output registers -10 VDC, which corresponds to the linear center of the 80 mil measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be connected directly to a PLC or DCS I\/O card?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive sensor and requires a 3300 XL Proximitor module to convert impedance changes into a scaled -24 VDC output or current signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 0.5 m cable length modifiable in the field?\u003c\/p\u003e\n\u003cp\u003eNo, the cable length is an integral part of the system impedance. Cutting or splicing will corrupt the scale factor and invalidate system accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the factory-calibrated target material?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for AISI 4140 steel. Monitoring different shaft materials will require a non-linear calibration or system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the ClickLoc connection hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the coaxial interface can be disconnected or connected while the system is powered, though a temporary channel fault alarm will occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include outer protective armor?\u003c\/p\u003e\n\u003cp\u003eNo, the 330104-00-07-05-02-00 part number utilizes standard coaxial cabling without stainless steel armor protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does humidity impact the coaxial junction?\u003c\/p\u003e\n\u003cp\u003eMoisture creates parallel leakage paths that skew signal output. Use the provided connector protector or self-fusing silicone tape in humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip is installed too close to the target?\u003c\/p\u003e\n\u003cp\u003eThe probe will enter the non-linear region or physical contact may occur, resulting in measurement saturation or mechanical damage to the probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807924909,"sku":"330104-00-07-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-07-05-02-00-3300-xl-8-mm-proximity-probes-hkzecaocape.jpg?v=1766979372"},{"product_id":"330103-00-11-10-02-00-bently-nevada-3300-xl-8-mm-series-proximity-probe","title":"330103-00-11-10-02-00 Bently Nevada 3300 XL 8 mm Series Proximity Probe","description":"\u003cp\u003eConfigured for displacement and vibration measurements in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-11-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. This non-contacting sensor transduces the dynamic gap between the probe tip and a conductive target into an electrical signal managed by a 3300 XL Proximitor Sensor. The assembly facilitates accurate monitoring of static shaft position and dynamic vibration parameters through high-frequency inductive coupling.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length option (0.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e11\u003c\/strong\u003e: Overall case length option (1.1 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total length option (1.0 m \/ 3.3 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector and cable option (Miniature coaxial ClickLoc connector with protector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (No approvals required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-11-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 cm x 20.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Probe Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm eddy-current probe scaling is physically calibrated for AISI 4140 steel targets. For operational readiness, gap voltage validation (-10 VDC targets) must be performed at the Proximitor sensor output to ensure the probe is positioned at the linear center of its measurement range. Effective rotor dynamics analysis requires this precise baseline. Furthermore, cross-talk suppression must be addressed during multi-probe installation by adhering to minimum radial and axial spacing requirements, ensuring independent signal processing of X and Y vibration planes.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330103-00-11-10-02-00 Proximity Probe with 1.0 m integrated coaxial lead wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Connector Protector Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation Technical Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Engagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the probe into the mounting bracket using a minimum of 5 full threads of engagement to ensure mechanical stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the probe position until the required gap voltage is achieved and torque the locknuts to a maximum of 5.1 N-m (45 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnforce a minimum bend radius of 25.4 mm (1.0 in) for the coaxial cable to avoid damaging the internal dielectric.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute probe cabling through dedicated grounded conduit, keeping it physically isolated from AC power or high-voltage lines to minimize noise induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat baseline output is required for probe calibration?\u003c\/p\u003e\n\u003cp\u003eThe probe must be physically gapped to result in a -10 VDC output from the associated Proximitor, corresponding to the midpoint of its linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe operate without the 3300 XL Proximitor?\u003c\/p\u003e\n\u003cp\u003eNo, this is a passive device. It must be paired with the matched 3300 XL Proximitor to convert impedance changes into a readable DC voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 1.0 m integral cable length changeable?\u003c\/p\u003e\n\u003cp\u003eNo, the cable length is an integral part of the tuned system. Any alteration will shift the system capacitance and invalidate the calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat target material is factory calibrated for this model?\u003c\/p\u003e\n\u003cp\u003eThe calibration is performed using AISI 4140 steel. Using other conductive materials will alter the scale factor and requires recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the ClickLoc connection hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the coaxial connection can be disconnected or reconnected while the system is energized, though it will trigger a channel fault signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does humidity affect the connector?\u003c\/p\u003e\n\u003cp\u003eMoisture creates leakage paths that skew gap readings. Use the provided connector protector or self-fusing silicone tape in high-humidity zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include outer armor?\u003c\/p\u003e\n\u003cp\u003eNo, this part number specifies the standard coaxial configuration without stainless steel armor protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip touches the rotating shaft?\u003c\/p\u003e\n\u003cp\u003eThe probe tip will likely suffer mechanical damage or deformation, leading to a permanent shift in the output signal or complete failure of the transducer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807990445,"sku":"330103-00-11-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-00-11-10-02-00-3300-xl-11-mm-proximity-transducer-k3twnh3d511.jpg?v=1766979374"},{"product_id":"330103-02-10-05-01-05-bently-nevada-3300-xl-8-mm-series-proximity-probe","title":"330103-02-10-05-01-05 Bently Nevada 3300 XL 8 mm Series Proximity Probe","description":"\u003cp\u003eConfigured for displacement and vibration measurements in machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-02-10-05-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. This non-contacting sensor transduces the dynamic distance between the probe tip and the observed conductive target into an electrical signal managed by a 3300 XL Proximitor Sensor. The hardware functions as the primary sensing interface for monitoring rotor dynamics, including radial vibration and axial position, within industrial monitoring frameworks.\u003c\/p\u003e\n\u003ch3\u003ePart Number Variable Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Unthreaded length option (0.2 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Overall case length option (1.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total length option (0.5 m \/ 1.6 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Connector and cable option (Miniature coaxial ClickLoc connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency approval option (Multiple thread-type approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-02-10-05-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 cm x 20.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 8 mm eddy-current probe system is calibrated for AISI 4140 steel targets to maintain linearity. Operational verification requires gap voltage validation (-10 VDC targets) at the Proximitor output to ensure the sensor is centered within its linear range. Precise rotor dynamics analysis depends on this calibration accuracy. Cross-talk suppression is achieved by observing minimum spacing between adjacent sensors, preventing interference of the high-frequency magnetic fields used to measure shaft displacement.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330103-02-10-05-01-05 Proximity Probe with 0.5 m integrated coaxial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Connector Protective Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Installation Technical Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Threading and Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the sensor into the mounting bracket using a minimum of 5 full threads of engagement to maintain structural stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten the hex jam nuts to a maximum of 5.1 N-m (45 in-lb) to prevent housing deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnforce a minimum bend radius of 25.4 mm (1.0 in) for the coaxial cable to prevent internal conductor damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute probe leads through grounded metal conduits, physically isolated from power or high-voltage lines to prevent EMI injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the target gap voltage for system calibration?\u003c\/p\u003e\n\u003cp\u003eThe probe must be physically positioned until the connected Proximitor sensor output reads -10 VDC, representing the center of the 80 mil linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be connected directly to a PLC analog input?\u003c\/p\u003e\n\u003cp\u003eNo, a 3300 XL Proximitor is required to perform RF modulation and demodulation to provide a usable voltage output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 0.5 m cable length adjustable?\u003c\/p\u003e\n\u003cp\u003eNo, the cable length is calibrated as part of the system impedance. Cutting or splicing will degrade the scale factor and system accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat target material is required for standard operation?\u003c\/p\u003e\n\u003cp\u003eThe factory calibration is specific to AISI 4140 steel. Other target materials will require a non-linear calibration or system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe connection hot-swappable?\u003c\/p\u003e\n\u003cp\u003eYes, the coaxial interface is hot-swappable while powered, though it will trigger a channel fault alarm on the monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the probe include armor protection?\u003c\/p\u003e\n\u003cp\u003eNo, this model uses the standard unarmored coaxial cable configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of moisture on the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress increases leakage resistance, which skews the gap voltage. Use the provided protective cap or silicone tape in humid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are orthogonal (X-Y) probes prevented from interfering?\u003c\/p\u003e\n\u003cp\u003eCross-talk suppression relies on maintaining the recommended separation distance between probe tips to ensure independent measurement of vibration planes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518808055981,"sku":"330103-02-10-05-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-02-10-05-01-05-3300-xl-8-mm-proximity-probes-r5plrnpvkcu.jpg?v=1766979377"}],"url":"https:\/\/www.maxwellplc.com\/collections\/bently-nevada-3300-xl-8mm-proximity-probes.oembed?page=44","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}