{"product_id":"yokogawa-aar145-s00-16-channel-rtd-pot-input-module","title":"Yokogawa AAR145-S00 16-Channel RTD\/POT Input Module","description":"\u003cp\u003eThe Yokogawa AAR145-S00 is a 16-channel isolated RTD and potentiometer input module for industrial process automation. It acquires resistance-based signals from compatible temperature sensors and potentiometers. Each channel can be configured for the required RTD or potentiometer input function. The module supports process temperature measurement and resistance-based position feedback in compatible Yokogawa control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 isolated input channels\u003c\/li\u003e\n\u003cli\u003eRTD and potentiometer input functions\u003c\/li\u003e\n\u003cli\u003eSupports three-wire Pt100 RTD measurement\u003c\/li\u003e\n\u003cli\u003ePotentiometer resistance range of 100 Ω to 10 kΩ\u003c\/li\u003e\n\u003cli\u003eIndividual RTD\/POT channel selection\u003c\/li\u003e\n\u003cli\u003eInput-to-system and channel-to-channel isolation\u003c\/li\u003e\n\u003cli\u003eRTD measurement current of 1 mA\u003c\/li\u003e\n\u003cli\u003e1-second data update period\u003c\/li\u003e\n\u003cli\u003eConfigurable sensor burnout detection\u003c\/li\u003e\n\u003cli\u003eDedicated cable connection options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAR145-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD\/POT Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eYokogawa AAR145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Input\u003c\/td\u003e\n\u003ctd\u003ePt100, 3-wire type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Standard\u003c\/td\u003e\n\u003ctd\u003eJIS C1604 \/ IEC 60751, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotentiometer Input\u003c\/td\u003e\n\u003ctd\u003e100 Ω to 10 kΩ total resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration Selection\u003c\/td\u003e\n\u003ctd\u003eRTD or POT selectable by channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e±5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Measurement Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Accuracy\u003c\/td\u003e\n\u003ctd\u003e±150 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOT Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Wiring Resistance\u003c\/td\u003e\n\u003ctd\u003e150 Ω or less per wire for RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e1 MΩ or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eBetween input channels and between field and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V AC between channels; field-to-system rating depends on connection configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurnout Detection\u003c\/td\u003e\n\u003ctd\u003eConfigurable; approximately 60-second detection time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Temperature Drift\u003c\/td\u003e\n\u003ctd\u003e±0.3 Ω per 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOT Temperature Drift\u003c\/td\u003e\n\u003ctd\u003e±0.4% per 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e350 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eDedicated KS8 cable or AKB335 cable, subject to module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.72 × 3.28 × 13.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe technical values above are based on published AAR145 product information and available Yokogawa documentation for related AAR145 configurations. Confirm the exact connection and hardware variant before applying them to a specific installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRTD Temperature Measurement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAR145-S00 supports resistance temperature detector inputs for industrial temperature monitoring. Its documented RTD configuration uses three-wire Pt100 sensors.\u003c\/p\u003e\n\u003cp\u003eThe module measures changes in sensor resistance and makes the corresponding process information available to the control system. Its 1 mA measurement current supports the RTD measurement circuit.\u003c\/p\u003e\n\u003cp\u003eThis function is suitable for temperature monitoring in process equipment, production systems, and industrial installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePotentiometer Input Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn addition to RTD measurement, the AAR145 supports potentiometer input. The documented potentiometer range is 100 Ω to 10 kΩ total resistance.\u003c\/p\u003e\n\u003cp\u003eRTD or potentiometer input functions can be selected individually for channels 1 through 16. This flexibility allows the module to accommodate different resistance-based measurement requirements.\u003c\/p\u003e\n\u003cp\u003eTypical applications include position feedback and resistance-based measurement devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel Isolation and Signal Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAR145 is designed with isolated input channels. Isolation is provided between individual input channels and between the field side and system side.\u003c\/p\u003e\n\u003cp\u003eThis architecture helps reduce electrical interference between connected measurement circuits. The documented withstand-voltage ratings depend on the specific module and connection configuration.\u003c\/p\u003e\n\u003cp\u003eFor critical installations, verify the manufacturer's isolation requirements and wiring instructions before connecting field instruments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAR145 family is associated with Yokogawa distributed control and remote I\/O applications. Yokogawa documentation also identifies AAR145 variants used for RIO system upgrades involving AMM32T, AMM32TJ, AMM32C, and AMM32CJ equipment.\u003c\/p\u003e\n\u003cp\u003eHowever, the -SM, -SK, and standard -S00 configurations should not be treated as interchangeable. Their connection interfaces and application details differ.\u003c\/p\u003e\n\u003cp\u003eConfirm the complete model designation, terminal arrangement, and existing system configuration before ordering a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore installing the AAR145-S00, verify the complete model designation and the required sensor configuration.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the module part number and suffix from the nameplate.\u003c\/li\u003e\n\u003cli\u003eCheck the compatible Yokogawa node and installation arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify the RTD or potentiometer input selection for each channel.\u003c\/li\u003e\n\u003cli\u003eConfirm Pt100 sensor wiring and lead resistance requirements.\u003c\/li\u003e\n\u003cli\u003eCheck the dedicated cable and terminal interface.\u003c\/li\u003e\n\u003cli\u003eVerify grounding and isolation arrangements.\u003c\/li\u003e\n\u003cli\u003eReview channel status and sensor diagnostics after installation.\u003c\/li\u003e\n\u003cli\u003ePerform measurement checks before returning the control system to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eUse the applicable Yokogawa installation documentation for the exact module version and connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAR145-S00 is suitable for applications requiring resistance-based process measurement.\u003c\/p\u003e\n\u003cp\u003eCommon application areas include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial temperature monitoring\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical processing\u003c\/li\u003e\n\u003cli\u003eOil and gas facilities\u003c\/li\u003e\n\u003cli\u003ePower generation systems\u003c\/li\u003e\n\u003cli\u003eManufacturing process equipment\u003c\/li\u003e\n\u003cli\u003eThermal process monitoring\u003c\/li\u003e\n\u003cli\u003eValve and actuator position feedback\u003c\/li\u003e\n\u003cli\u003eDistributed control system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Genuine Yokogawa Replacement Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct Yokogawa module helps maintain consistency with the installed control system architecture. Matching the input type, channel configuration, and cable interface is particularly important for RTD and potentiometer applications.\u003c\/p\u003e\n\u003cp\u003eBefore replacement, compare the complete model number and hardware identification. Also verify the sensor wiring and channel configuration to reduce commissioning problems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Yokogawa AAR145-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAR145-S00 is a 16-channel isolated RTD\/POT input module designed for resistance-based measurement applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many input channels does the AAR145-S00 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides 16 isolated input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Which RTD sensor does the AAR145 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documented RTD input includes three-wire Pt100 sensors. Confirm the applicable sensor standard and configuration before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Can the AAR145-S00 accept potentiometer signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The AAR145 supports potentiometer inputs with a documented total resistance range of 100 Ω to 10 kΩ.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Can each channel be configured independently?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAR145 documentation describes individual RTD\/POT selection for channels 1 through 16.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. What is the data update period?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable AAR145 specifications list a data update period of approximately one second.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Does the AAR145 provide channel isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module is specified as a 16-channel isolated input module, with isolation between channels and between field and system circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What should I verify before purchasing a replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete model suffix, input sensor type, channel configuration, cable interface, terminal arrangement, and compatibility with the installed Yokogawa system.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68376292655277,"sku":"AAR145-S00","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/aar145-s00-1.jpg?v=1795138399","url":"https:\/\/www.maxwellplc.com\/ar\/products\/yokogawa-aar145-s00-16-channel-rtd-pot-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}