{"product_id":"yokogawa-aai835-s00-s2-analog-i-o-module","title":"Yokogawa AAI835-S00 S2 Analog I\/O Module","description":"\u003cp\u003eThe Yokogawa AAI835-S00 S2 is an isolated analog input\/output module designed for industrial distributed control systems. It provides four 4–20 mA analog input channels and four 4–20 mA analog output channels. The module supports signal acquisition and output control between field instruments and the control system. Its channel isolation helps separate field signals from the system and individual channels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour isolated analog input channels\u003c\/li\u003e\n\u003cli\u003eFour isolated analog output channels\u003c\/li\u003e\n\u003cli\u003eSupports standard 4–20 mA DC signals\u003c\/li\u003e\n\u003cli\u003eIsolation between field and system circuits\u003c\/li\u003e\n\u003cli\u003eIsolation between individual input\/output channels\u003c\/li\u003e\n\u003cli\u003e10 ms data update period\u003c\/li\u003e\n\u003cli\u003eSupports dual-redundant system configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with designated Yokogawa FIO and CENTUM system architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI835-S00 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eAnalog Input \/ Analog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±16 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±48 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e290 Ω at 20 mA to 450 Ω at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e500 kΩ or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0–750 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit-Open Detection\u003c\/td\u003e\n\u003ctd\u003eLess than 0.65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e±16 μA\/10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute, subject to connection configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e360 mA at 5 V DC; 450 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, MIL connector cable, or dedicated KS1 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eDepends on the module suffix and system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.75 × 3.28 × 13.00 cm, 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Input and Output Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI835 combines analog signal acquisition and output control within one module. Its four input channels receive 4–20 mA signals from compatible field transmitters.\u003c\/p\u003e\n\u003cp\u003eThe four output channels deliver 4–20 mA control signals to compatible field devices. This arrangement supports applications requiring both measurement and analog control.\u003c\/p\u003e\n\u003cp\u003eThe module provides a 10 ms data update period. Its published accuracy specifications are ±16 μA for input and ±48 μA for output.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel Isolation and Electrical Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI835 provides isolation between the field and system circuits, as well as between individual channels. This arrangement helps reduce unwanted electrical interference between connected signals.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifies a withstand voltage of 500 V AC for one minute under the documented test conditions. Actual withstand-voltage performance depends on the selected external connection and cable specifications.\u003c\/p\u003e\n\u003cp\u003eFor intrinsically safe applications, an appropriate isolation barrier must be used. Yokogawa documentation does not permit direct connection of a Zener barrier to this module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI835 series is documented for Yokogawa CENTUM CS 3000 FIO architectures. Compatible installation arrangements include designated ESB bus nodes, ER bus nodes, and compact field control units.\u003c\/p\u003e\n\u003cp\u003eSystem integration must follow the applicable hardware configuration and installation documentation. Verify the node type, module suffix, terminal arrangement, cable selection, and system firmware before replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore installing the AAI835-S00 S2, confirm that the existing control system supports the exact module configuration.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eIsolate the relevant equipment and follow the site's electrical safety procedures.\u003c\/li\u003e\n\u003cli\u003eConfirm the module model and suffix against the system bill of materials.\u003c\/li\u003e\n\u003cli\u003eCheck the assigned module slot and compatible node configuration.\u003c\/li\u003e\n\u003cli\u003eVerify the input and output wiring against the approved connection diagram.\u003c\/li\u003e\n\u003cli\u003eConfirm signal polarity, grounding, shielding, and external cable compatibility.\u003c\/li\u003e\n\u003cli\u003eCheck channel configuration and system diagnostics after installation.\u003c\/li\u003e\n\u003cli\u003ePerform controlled input and output functional tests before returning the system to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor redundant applications, verify that both modules and their suffix configurations meet the system's redundancy requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI835 is suitable for industrial process control systems requiring both analog measurement and output functions.\u003c\/p\u003e\n\u003cp\u003eCommon application areas include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas processing facilities\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli\u003ePower generation and utilities\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli\u003eIndustrial manufacturing\u003c\/li\u003e\n\u003cli\u003eProcess instrumentation and control\u003c\/li\u003e\n\u003cli\u003eDistributed control system installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Genuine Yokogawa Replacement Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct Yokogawa module helps maintain consistency with the installed control system architecture. Accurate model and suffix identification also reduces the risk of wiring, configuration, and compatibility issues.\u003c\/p\u003e\n\u003cp\u003eBefore replacement, compare the complete part number and hardware configuration with the installed module. Similar-looking analog I\/O modules may have different channel functions, communication capabilities, or installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Yokogawa AAI835-S00 S2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is an isolated analog I\/O module with four 4–20 mA input channels and four 4–20 mA output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many channels does the AAI835 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides eight channels in total: four analog inputs and four analog outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What signal range does the AAI835 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth its analog input and output channels use 4–20 mA DC signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Are the AAI835 channels isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The documented design provides isolation between the field and system circuits and between individual channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Can the AAI835 be used in a redundant system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAI835 series supports dual-redundant configurations. Confirm the required suffix and system arrangement before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Does the AAI835 support HART communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa lists a separate HART suffix, -H, for this module family. Do not assume HART functionality on an -S configuration without confirming the exact hardware identification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Which cable or terminal connections are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's documentation lists pressure clamp terminals, MIL connector cables, and dedicated KS1 cables. The actual interface depends on the selected connection arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What should be checked before replacing an AAI835?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the full model and suffix, system compatibility, module slot, terminal or cable interface, signal wiring, and redundancy configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68376050991277,"sku":"AAI835-S00","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/aai835-s00-2.jpg?v=1795137823","url":"https:\/\/www.maxwellplc.com\/ar\/products\/yokogawa-aai835-s00-s2-analog-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}