{"product_id":"yokogawa-aai135-s00-8-channel-analog-input-module","title":"Yokogawa AAI135-S00 8-Channel Analog Input Module","description":"\u003cp\u003eThe Yokogawa AAI135-S00 is an isolated analog input module designed for Yokogawa Fieldbus I\/O (FIO) and CENTUM distributed control systems. It provides eight independent input channels for receiving standard 4–20 mA DC signals from industrial field transmitters. Channel-to-channel and field-to-system isolation support reliable process signal acquisition in demanding automation environments. The module is suitable for process monitoring and control applications requiring accurate analog measurement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight isolated analog input channels\u003c\/li\u003e\n\u003cli\u003eSupports standard 4–20 mA DC signals\u003c\/li\u003e\n\u003cli\u003eChannel-to-channel electrical isolation\u003c\/li\u003e\n\u003cli\u003eIsolation between field signals and system circuits\u003c\/li\u003e\n\u003cli\u003eMeasurement accuracy of ±16 μA\u003c\/li\u003e\n\u003cli\u003e10 ms data update period\u003c\/li\u003e\n\u003cli\u003eSupports dual-redundant system configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with designated Yokogawa FIO architectures\u003c\/li\u003e\n\u003cli\u003eSupports pressure clamp terminals, MIL connector cables, and dedicated KS1 cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI135-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eYokogawa FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e8-channel isolated input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±16 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e290 Ω at 20 mA to 450 Ω at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e500 kΩ or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute, input-to-system and input-channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003e15.0 V minimum at 20 mA; 29.3 V maximum at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e±16 μA per 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e360 mA at 5 V DC; 450 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, MIL connector cable, or dedicated KS1 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eConfirm according to module suffix and system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.75 × 3.28 × 13.00 cm, 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Input Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135-S00 receives standard 4–20 mA current signals from industrial field transmitters. Its eight input channels allow multiple process variables to be collected through one module.\u003c\/p\u003e\n\u003cp\u003eTypical connected instruments include pressure transmitters, flow transmitters, level transmitters, and other compatible current-output devices.\u003c\/p\u003e\n\u003cp\u003eThe module converts incoming analog signals into digital process data for use by the Yokogawa control system. Its 10 ms data update period supports continuous process monitoring and control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eChannel Isolation and Signal Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135-S00 provides electrical isolation between individual input channels and between the field side and system side. This design helps reduce ground-loop interference and unwanted electrical coupling between connected instruments.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifies a withstand voltage of 500 V AC for one minute between input and system circuits, and between input channels. Actual isolation performance also depends on the selected cable and connection arrangement.\u003c\/p\u003e\n\u003cp\u003eFor intrinsically safe installations, use an appropriate isolation barrier. A Zener barrier must not be connected directly to this module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135 belongs to Yokogawa's FIO analog input module family. The manufacturer's FIO documentation identifies compatible installation platforms including designated ESB bus node units and FIO field control units.\u003c\/p\u003e\n\u003cp\u003eSystem compatibility should be checked against the actual control system architecture. Confirm the node type, module slot, terminal interface, and system configuration before ordering a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore installing the AAI135-S00, verify that the existing Yokogawa system supports the exact module configuration.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the complete model number and suffix on the module nameplate.\u003c\/li\u003e\n\u003cli\u003eCheck the designated installation node and module position.\u003c\/li\u003e\n\u003cli\u003eVerify the terminal board and cable interface.\u003c\/li\u003e\n\u003cli\u003eConfirm the 4–20 mA signal wiring and transmitter requirements.\u003c\/li\u003e\n\u003cli\u003eCheck grounding, shielding, and isolation arrangements.\u003c\/li\u003e\n\u003cli\u003eVerify the configured channel assignments in the control system.\u003c\/li\u003e\n\u003cli\u003ePerform signal checks and diagnostic tests before returning equipment to operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor redundant applications, confirm that the standby module and associated system configuration meet the manufacturer's requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AAI135-S00 is used in process automation systems that require isolated analog signal acquisition from field instruments.\u003c\/p\u003e\n\u003cp\u003eCommon applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas processing facilities\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli\u003ePower generation facilities\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment plants\u003c\/li\u003e\n\u003cli\u003ePharmaceutical manufacturing\u003c\/li\u003e\n\u003cli\u003ePulp and paper production\u003c\/li\u003e\n\u003cli\u003eIndustrial process monitoring\u003c\/li\u003e\n\u003cli\u003eDistributed control system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Genuine Yokogawa Replacement Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUsing the correct Yokogawa replacement module helps maintain consistency with the installed FIO hardware architecture. Accurate model identification is particularly important where channel isolation, wiring interfaces, and redundancy configurations are involved.\u003c\/p\u003e\n\u003cp\u003eBefore replacing an existing module, compare the complete model number and suffix. Also verify the terminal board, cable arrangement, and system configuration to reduce installation and commissioning risks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Yokogawa AAI135-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAI135-S00 is an eight-channel isolated analog input module for receiving 4–20 mA signals in compatible Yokogawa control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many input channels does the AAI135-S00 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides eight independent analog input channels with channel-to-channel isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What input signal does this module support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module accepts standard 4–20 mA DC current signals from compatible industrial transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What is the measurement accuracy of the AAI135-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe published input accuracy is ±16 μA under the specified operating conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Does the AAI135-S00 support redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AAI135 module family supports dual-redundant configurations. Confirm the system architecture and installation requirements before implementation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Which Yokogawa terminal connections are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documented connection options include pressure clamp terminals, MIL connector cables, and dedicated KS1 cables. The required interface depends on the selected installation arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Can the AAI135-S00 connect directly to a Zener barrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Yokogawa specifies that a Zener barrier must not be connected to this module. Use an appropriate isolation barrier for intrinsically safe applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What should I check before purchasing a replacement AAI135-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify the full model number, suffix, input signal requirements, terminal interface, node compatibility, and redundancy configuration against the installed system.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68376156864685,"sku":"AAI135-S00","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/aai135-s00-2.jpg?v=1795138173","url":"https:\/\/www.maxwellplc.com\/ar\/products\/yokogawa-aai135-s00-8-channel-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}