{"product_id":"h5cx-a11-n-ac100-240-omron-digital-multifunction-timer-h5cx-series","title":"OMRON INDUSTRIAL AUTOMATION H5CX-A11-N AC100-240. مؤقت رقمي متعدد الوظائف","description":"\u003cp\u003eThe \u003cstrong\u003eOmron H5CX-A11-N AC100-240\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eH5CX-A11-N\u003c\/strong\u003e Digital Multifunction Timer, operates as a dedicated hardware component for programmable time delay execution and pulse interval switching within industrial sequence control panels.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eH5CX\u003c\/strong\u003e: Ultra-compact 48 x 48 mm digital timer product family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Standard functions with basic timing modes (ON-delay, repeat cycle, signal OFF-delay, interval).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11\u003c\/strong\u003e: 11-pin round socket connection configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Updated model revision featuring enhanced display color switching and dual-timer functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC100-240\u003c\/strong\u003e: Rated operational power supply voltage range (100 to 240 VAC, 50\/60 Hz).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eH5CX-A11-N AC100-240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.130 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.280 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e8.40 cm x 4.80 cm x 4.80 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.00 cm x 8.00 cm x 7.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.6 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eNegative transmissive LCD with red\/green backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact\u003c\/td\u003e\n\u003ctd\u003eSPDT (1c, 5 A at 250 VAC \/ 30 VDC resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Ranges\u003c\/td\u003e\n\u003ctd\u003e0.001 s to 9999 h (10 selectable ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Integration \u0026amp; Execution\u003c\/h3\u003e\n\u003cp\u003eThe unit integrates into standard automated panel networks to process precision timing cycles with high-frequency repeat accuracy. Deterministic logic execution ensures zero timing jitter across multi-stage machine operations, while non-volatile memory registers retain firmware flash compatibility and program parameters during power interruptions without requiring battery backup.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron H5CX-A11-N AC100-240 Digital Multifunction Timer\u003c\/li\u003e\n\u003cli\u003e1 x Waterproof packing gasket (for NEMA 4X \/ IP66 front panel sealing)\u003c\/li\u003e\n\u003cli\u003e1 x Panel mounting adapter frame\u003c\/li\u003e\n\u003cli\u003e1 x Instruction manual sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting \u0026amp; Electrical Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the timer chassis into a standard 45 x 45 mm DIN front panel cutout, securing it with the rear panel adapter.\u003c\/li\u003e\n\u003cli\u003eWire the 100-240 VAC supply lines to pins 2 and 10 of the standard 11-pin socket using insulated copper wire.\u003c\/li\u003e\n\u003cli\u003eConnect input control signals (Start, Reset, Gate) to pins 5, 6, and 7 using NPN or PNP solid-state connections or dry contacts.\u003c\/li\u003e\n\u003cli\u003eRoute output switching contacts (pins 1, 3, 4 for SPDT) through dedicated circuit breakers to protect relay contact points.\u003c\/li\u003e\n\u003cli\u003eSeparate high-voltage AC load wiring from low-voltage DC input signal wiring to eliminate electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan the H5CX-A11-N be mounted directly to a DIN rail without a panel cutout?\u003c\/p\u003e\n\u003cp\u003eYes, the unit connects to a 35 mm DIN rail by inserting it into a standard 11-pin socket like the P2CF-11 rear-connecting socket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the display backlight color configured on this timer model?\u003c\/p\u003e\n\u003cp\u003eDisplay color can be set in program mode to remain solid red, solid green, or switch dynamically from green to red when time expires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the accumulated time count if main power supply fails?\u003c\/p\u003e\n\u003cp\u003eAn internal EEPROM stores current count status and setup parameters continuously, resuming operation upon power restoration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the signal input terminals isolated from the main supply voltage?\u003c\/p\u003e\n\u003cp\u003eYes, internal galvanic isolation separates the high-voltage AC operating supply from low-voltage input control terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the minimum input signal pulse duration required for reliable triggering?\u003c\/p\u003e\n\u003cp\u003eThe minimum input signal duration for Start, Reset, and Gate terminals is user-selectable between 1 ms and 20 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the timer be configured for dual-timing or twin-timer operating modes?\u003c\/p\u003e\n\u003cp\u003eYes, the N-series architecture allows selection of twin-timer mode to independently program ON-time and OFF-time duration cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is key protection enabled to prevent unauthorized parameter changes?\u003c\/p\u003e\n\u003cp\u003eHold down the MODE key while adjusting DIP switches or setup parameters to engage four distinct key-protect security levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for replacing the timer unit during operation?\u003c\/p\u003e\n\u003cp\u003eNo, line voltage to the 11-pin base socket must be disconnected before pulling the timer unit out of its socket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306665623725,"sku":"H5CX-A11-N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/H5CX-A11-N-1.jpg?v=1790689187","url":"https:\/\/www.maxwellplc.com\/ar\/products\/h5cx-a11-n-ac100-240-omron-digital-multifunction-timer-h5cx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}