{"product_id":"basler-decs-250-ln1sn1n-digital-excitation-control-system","title":"Basler DECS-250-LN1SN1N Digital Excitation Control System","description":"\u003cp\u003eThe Basler Electric DECS-250-LN1SN1N is a microprocessor-based digital excitation control system for synchronous generators and motors. It provides automatic voltage regulation (AVR), field-current regulation (FCR), reactive-power (VAR) regulation, and power-factor (PF) regulation. This configuration uses 24\/48 VDC control power, spring-type terminals, internal autotracking, and standard copper Ethernet communication. Its PWM excitation power stage supplies up to 15 A DC continuously at nominal field voltages of 32, 63, or 125 VDC.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250 is designed to regulate generator or motor excitation and provide machine protection within a single control package. It monitors electrical operating conditions and adjusts DC excitation power supplied to the exciter field.\u003c\/p\u003e\n\u003cp\u003eThe controller uses a filtered, switching power module based on pulse-width modulation (PWM). Its regulation and protection functions support generator voltage stability, reactive-power management, and coordinated operation in parallel generating systems.\u003c\/p\u003e\n\u003cp\u003eThe complete style number identifies the unit's selected configuration. The LN1SN1N version has the following characteristics:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24\/48 VDC control power supply\u003c\/li\u003e\n\u003cli\u003eNo integrated Power System Stabilizer (PSS)\u003c\/li\u003e\n\u003cli\u003eInternal autotracking only\u003c\/li\u003e\n\u003cli\u003eSpring-type terminals\u003c\/li\u003e\n\u003cli\u003eNo automatic synchronizer\u003c\/li\u003e\n\u003cli\u003e100Base-T copper Ethernet communication\u003c\/li\u003e\n\u003cli\u003eNo additional PROFIBUS communication option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese configuration details are important when selecting a replacement for an existing installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDigital excitation control for synchronous generators and motors\u003c\/li\u003e\n\u003cli\u003eAutomatic Voltage Regulation (AVR)\u003c\/li\u003e\n\u003cli\u003eField Current Regulation (FCR)\u003c\/li\u003e\n\u003cli\u003eReactive Power (VAR) regulation\u003c\/li\u003e\n\u003cli\u003ePower Factor (PF) regulation\u003c\/li\u003e\n\u003cli\u003ePWM-based excitation power stage\u003c\/li\u003e\n\u003cli\u003e15 A continuous excitation output at nominal field voltage\u003c\/li\u003e\n\u003cli\u003e30 A excitation forcing capability for 10 seconds\u003c\/li\u003e\n\u003cli\u003eOverexcitation and underexcitation limiting\u003c\/li\u003e\n\u003cli\u003eVolts-per-hertz protection\u003c\/li\u003e\n\u003cli\u003eGenerator voltage, current, and frequency monitoring\u003c\/li\u003e\n\u003cli\u003e16 contact inputs, including 14 programmable inputs\u003c\/li\u003e\n\u003cli\u003e11 programmable contact outputs and one watchdog output\u003c\/li\u003e\n\u003cli\u003e100Base-T Ethernet with Modbus TCP communication\u003c\/li\u003e\n\u003cli\u003eConfiguration and monitoring through BESTCOMSPlus software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBasler Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eDECS-250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eDECS-250-LN1SN1N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Excitation Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Function\u003c\/td\u003e\n\u003ctd\u003eGenerator and Motor Excitation Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Technology\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-Based Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Configuration\u003c\/td\u003e\n\u003ctd\u003e24\/48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Input Range\u003c\/td\u003e\n\u003ctd\u003e16–60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePSS Configuration\u003c\/td\u003e\n\u003ctd\u003eNo Integrated PSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotracking\u003c\/td\u003e\n\u003ctd\u003eInternal Autotracking Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eSpring-Type Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronizer\u003c\/td\u003e\n\u003ctd\u003eNo Automatic Synchronizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Communication\u003c\/td\u003e\n\u003ctd\u003e100Base-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecond Communication Protocol\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Output Technology\u003c\/td\u003e\n\u003ctd\u003ePWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Excitation Current\u003c\/td\u003e\n\u003ctd\u003e15 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current at Reduced Temperature\u003c\/td\u003e\n\u003ctd\u003e20 A DC up to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Forcing Current\u003c\/td\u003e\n\u003ctd\u003e30 A DC for 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Excitation Voltage Options\u003c\/td\u003e\n\u003ctd\u003e32 \/ 63 \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Power Frequency\u003c\/td\u003e\n\u003ctd\u003e50–500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Power Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase or Three-Phase AC; DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Voltage Sensing\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase or Three-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Sensing Ranges\u003c\/td\u003e\n\u003ctd\u003e100\/120, 200\/240, 400\/480, or 600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Current Sensing\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Modes\u003c\/td\u003e\n\u003ctd\u003eAVR, FCR, VAR, PF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Total; 14 Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Outputs\u003c\/td\u003e\n\u003ctd\u003e11 Programmable Form A and 1 Watchdog Form C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP over Ethernet; additional interfaces depend on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eBESTCOMSPlus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C at 15 A continuous output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature at 20 A\u003c\/td\u003e\n\u003ctd\u003e-40°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e159 × 304.8 × 219 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e6.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eExcitation Control and Regulation Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250 provides several operating modes to support different generator and motor control requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Voltage Regulation (AVR)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAVR mode automatically adjusts excitation to maintain the generator voltage at its configured setpoint. It is commonly used for normal generator voltage control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Current Regulation (FCR)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFCR mode regulates excitation according to the field-current reference. It provides an alternative operating mode for excitation control and maintenance procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReactive Power Regulation (VAR)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVAR mode regulates the machine's reactive-power output. It is useful for coordinating reactive-power requirements in parallel generator installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Factor Regulation (PF)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePF mode regulates the generator's power factor according to the configured setpoint. It supports power-factor management in industrial power systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExcitation Power Stage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250 uses a filtered PWM switching power module to supply regulated DC excitation power to the exciter field.\u003c\/p\u003e\n\u003cp\u003eThe documented continuous output capability is 15 A DC at nominal field voltages of 32, 63, or 125 VDC. The system can also provide 30 A DC forcing current for 10 seconds when nominal operating power is applied.\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation Voltage\u003c\/th\u003e\n\u003cth\u003eNominal Operating Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e32 VDC\u003c\/td\u003e\n\u003ctd\u003e60 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e63 VDC\u003c\/td\u003e\n\u003ctd\u003e120 VAC or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003ctd\u003e240 VAC or 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe actual operating power connection must match the required excitation voltage and generator field characteristics. Confirm the exciter field resistance and power-source arrangement before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection and Limiting Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250 combines excitation regulation with protection functions for generator and motor applications.\u003c\/p\u003e\n\u003cp\u003eIts protection capabilities include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerator overvoltage and undervoltage protection\u003c\/li\u003e\n\u003cli\u003eLoss-of-sensing protection\u003c\/li\u003e\n\u003cli\u003eVolts-per-hertz protection\u003c\/li\u003e\n\u003cli\u003eOverexcitation limiting (OEL)\u003c\/li\u003e\n\u003cli\u003eUnderexcitation limiting (UEL)\u003c\/li\u003e\n\u003cli\u003eField-related protection\u003c\/li\u003e\n\u003cli\u003eFrequency and power-related protection\u003c\/li\u003e\n\u003cli\u003eConfigurable protection logic and alarm functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese functions help maintain appropriate operating conditions and protect connected equipment from abnormal electrical conditions. Actual protection settings depend on the generator characteristics and the commissioned application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250-LN1SN1N includes standard 100Base-T copper Ethernet communication. The Ethernet interface supports Modbus TCP communication.\u003c\/p\u003e\n\u003cp\u003eThe controller also provides local operation through its front-panel display and controls. Engineers can configure regulation parameters, protection settings, and programmable logic using Basler BESTCOMSPlus software.\u003c\/p\u003e\n\u003cp\u003eThe LN1SN1N style does not include the optional PROFIBUS communication interface. Additional communication capabilities should not be assumed without checking the complete unit configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Wiring Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250 is supplied in a projection-mounting configuration. Its installation requires suitable mechanical support, electrical clearances, and access to the connection terminals.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the following:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the complete style number on the product identification label.\u003c\/li\u003e\n\u003cli\u003eProvide a 24\/48 VDC control supply within the specified 16–60 VDC range.\u003c\/li\u003e\n\u003cli\u003eSelect the correct operating power source for the required excitation voltage.\u003c\/li\u003e\n\u003cli\u003eVerify generator voltage sensing and current transformer connections.\u003c\/li\u003e\n\u003cli\u003eConnect the excitation field wiring to the designated F+ and F− terminals.\u003c\/li\u003e\n\u003cli\u003eCheck grounding, terminal connections, and protective wiring.\u003c\/li\u003e\n\u003cli\u003eBack up the existing configuration before changing operating parameters.\u003c\/li\u003e\n\u003cli\u003eVerify control modes, protection settings, and generator response during commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eElectrical installation and commissioning should be performed by qualified personnel familiar with generator excitation systems. Follow the manufacturer's instructions and the applicable electrical safety procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Basler DECS-250-LN1SN1N is suitable for excitation control in industrial power-generation and synchronous machine installations.\u003c\/p\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial generator excitation systems\u003c\/li\u003e\n\u003cli\u003eDiesel generator power plants\u003c\/li\u003e\n\u003cli\u003eHydroelectric power stations\u003c\/li\u003e\n\u003cli\u003eSteam turbine generator systems\u003c\/li\u003e\n\u003cli\u003eGas turbine generator installations\u003c\/li\u003e\n\u003cli\u003eMarine power-generation systems\u003c\/li\u003e\n\u003cli\u003eIndustrial captive power plants\u003c\/li\u003e\n\u003cli\u003eSynchronous motor excitation control\u003c\/li\u003e\n\u003cli\u003eGenerator paralleling and reactive-power management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe DECS-250-LN1SN1N is designed for synchronous generator and motor excitation applications. Its suitability depends on the generator field requirements, sensing configuration, operating power source, and control-system architecture.\u003c\/p\u003e\n\u003cp\u003eBefore replacing an existing unit, compare the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete DECS-250 style number\u003c\/li\u003e\n\u003cli\u003eControl power supply requirements\u003c\/li\u003e\n\u003cli\u003eExcitation output voltage and current\u003c\/li\u003e\n\u003cli\u003eGenerator voltage sensing range\u003c\/li\u003e\n\u003cli\u003eCurrent transformer secondary rating\u003c\/li\u003e\n\u003cli\u003eTerminal type and wiring arrangement\u003c\/li\u003e\n\u003cli\u003eEthernet communication requirements\u003c\/li\u003e\n\u003cli\u003eRequired protection and synchronization functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The LN1SN1N configuration does not include an integrated PSS or automatic synchronizer. If the original installation uses either function, verify the replacement configuration carefully before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Correct Replacement Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA correctly matched DECS-250 replacement helps maintain the intended generator excitation architecture and control functions.\u003c\/p\u003e\n\u003cp\u003eMatching the complete style number is especially important because the DECS-250 family includes different power supplies, terminal arrangements, tracking options, synchronization features, and communication interfaces.\u003c\/p\u003e\n\u003cp\u003eFor replacement planning, compare the original unit's label and application settings rather than relying only on the DECS-250 model family name.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Basler DECS-250-LN1SN1N?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a digital excitation control system used to regulate and protect synchronous generators and motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What control power supply does this model require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LN configuration uses a 24\/48 VDC control power supply, with an accepted input range of 16–60 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What excitation output current does the DECS-250 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supplies 15 A DC continuously at nominal excitation voltages of 32, 63, or 125 VDC. It can provide 30 A DC for 10 seconds under specified operating conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Which regulation modes are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller supports AVR, FCR, VAR, and power-factor regulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Does the LN1SN1N configuration include a Power System Stabilizer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The second character of the style number is N, which identifies the configuration without an integrated PSS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. What communication interface does this model provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sixth style-number character is 1, identifying standard 100Base-T copper Ethernet. The Ethernet interface supports Modbus TCP communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Does this model include an automatic synchronizer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The fifth style-number character is N, indicating that the automatic synchronizer option is not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What software is used to configure the DECS-250?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasler BESTCOMSPlus software is used to configure operating parameters, protection functions, and programmable logic.\u003c\/p\u003e","brand":"Basler","offers":[{"title":"Default Title","offer_id":68382377803949,"sku":"DECS-250-LN1SN1N","price":3869.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/decs-250-ln1sn1n-4.jpg?v=1795161602","url":"https:\/\/www.maxwellplc.com\/ar\/products\/basler-decs-250-ln1sn1n-digital-excitation-control-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}